Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Thermal Analysis of Large Area Additive Manufacturing Resistance Heating Composites for Out of Oven/Autoclave Applications

Additive Manufacturing (AM) of carbon fiber (CF) reinforced composite has received growing attention because of the design flexibility, superior mechanical properties, improved thermal properties, and weight reduction. Autoclave tooling was proven to be a successful application for large scale AM technology. The capital cost, and cost associated with heating, and cycle time in a conventional autoclave process is relatively high. Thus, an innovative design of AM mold with an efficient heating scheme is essential. This study represents an innovative method of the resistive heating of composite molds which does not require a room size oven for heating during the curing processing. Therefore, it has the potential to reduce the operating cost drastically. For the design validation and feasibility study, we performed a numerical analysis of the wire embedded and AM mold parts. The goal of this study is to determine and optimize the thermal behavior of the printed mold with embedded wire technology. It is anticipated that the larger distance between the embedded wires along the printing direction (z-direction) increase the cold spot, on the other hand, a close distance of the wire can create the unwanted localize heating, thus melting. Constant thermal properties of the 20 wt.% short CF reinforced acrylonitrile butadiene styrene (ABS) was used for the simulation purpose. Thermal characterization was set to 100°C to avoid the thermal deformation or bulging on the part surface.

billah, Kazi↗

Thermal Analysis of Large Area Additive Manufacturing Resistance Heating Composites for Out of Oven/Autoclave Applications

Additive Manufacturing (AM) of carbon fiber (CF) reinforced composite has received growing attention because of the design flexibility, superior mechanical properties, improved thermal properties, and weight reduction. Autoclave tooling was proven to be a successful application for large scale AM technology. The capital cost, and cost associated with heating, and cycle time in a conventional autoclave process is relatively high. Thus, an innovative design of AM mold with an efficient heating scheme is essential. This study represents an innovative method of the resistive heating of composite molds which does not require a room size oven for heating during the curing processing. Therefore, it has the potential to reduce the operating cost drastically. For the design validation and feasibility study, we performed a numerical analysis of the wire embedded and AM mold parts. The goal of this study is to determine and optimize the thermal behavior of the printed mold with embedded wire technology. It is anticipated that the larger distance between the embedded wires along the printing direction (z-direction) increase the cold spot, on the other hand, a close distance of the wire can create the unwanted localize heating, thus melting. Constant thermal properties of the 20 wt.% short CF reinforced acrylonitrile butadiene styrene (ABS) was used for the simulation purpose. Thermal characterization was set to 100°C to avoid the thermal deformation or bulging on the part surface.

billah, Kazi↗

Thermal Analysis of Large Area Additive Manufacturing Resistance Heating Composites for Out of Oven/Autoclave Applications

Additive Manufacturing (AM) of carbon fiber (CF) reinforced composite has received growing attention because of the design flexibility, superior mechanical properties, improved thermal properties, and weight reduction. Autoclave tooling was proven to be a successful application for large scale AM technology. The capital cost, and cost associated with heating, and cycle time in a conventional autoclave process is relatively high. Thus, an innovative design of AM mold with an efficient heating scheme is essential. This study represents an innovative method of the resistive heating of composite molds which does not require a room size oven for heating during the curing processing. Therefore, it has the potential to reduce the operating cost drastically. For the design validation and feasibility study, we performed a numerical analysis of the wire embedded and AM mold parts. The goal of this study is to determine and optimize the thermal behavior of the printed mold with embedded wire technology. It is anticipated that the larger distance between the embedded wires along the printing direction (z-direction) increase the cold spot, on the other hand, a close distance of the wire can create the unwanted localize heating, thus melting. Constant thermal properties of the 20 wt.% short CF reinforced acrylonitrile butadiene styrene (ABS) was used for the simulation purpose. Thermal characterization was set to 100°C to avoid the thermal deformation or bulging on the part surface.

billah, Kazi↗

Design and experimental testing of a 150 kWh thermal battery using thermosiphons embedded in a concrete matrix for power plant flexible operation

One of the options for achieving the global temperature limitation of 1.5 °C target, for the mitigation of global warming, is based on the better penetration of renewables into the electrical grid. This has imposed a burden to fossil fuel fired power plants since they are required to operate away from their baseload mode to compensate for the inherent intermittence of the renewable power. Integrating energy storage with fossil plants is an option to achieve their needed flexibility. A cost competitive energy storage option for the solution is based on storing sensible heat in concrete. Here, this paper reports research results and development of a thermal battery cell (TBC) capable of operating at temperatures up to 425 °C. A novel concept consisting of a concrete matrix for sensible heat storage, engineered to provide enhanced thermal and mechanical properties, and twenty-two thermosiphon elements, engineered for dual action were designed and fabricated into a single thermal energy storage (TES) module. Research for the development of the components for the TBC was performed in the laboratory. Efficient heat transfer, to/from the storage media, was demonstrated under several charging and discharging conditions with a thermal storage capacity of 150 kWh th and a rapid discharge, making the TBC suitable for fast ramping when integrated with a fossil fuel fired power plant. Efficient radial heat transfer to the concrete was observed due to the well designed spacing and location of thermosiphons in the radial direction. A minimal temperature difference of 2 °C, between the thermosiphons bottom and top was obtained, demonstrating the isothermicity of those elements. An overall end-to-end TBC energy-to-energy round trip efficiency of 70% was achieved.

25 ENERGY STORAGE↗

Techno-Economic and Deployment Analysis of Fossil Fuel-Based Power Generation with Integrated Energy Storage

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenues. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation such as wind and solar is shifting traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. The recent studies have shown that flexibility of a coal-fired power plant can be improved by the energy storage. The objective of this project was to analyze a set of energy storage options (technologies) and determine their impact on flexibility and economics of a representative coal-fired power plant. The effect of five Energy Storage Systems (ESSs) integrated with a coal power plant on plant flexibility and economics was investigated in this study. The results obtained in this project and presented in this report showed that ESS integrated with a thermal power plant improves plant flexibility and participation in the Energy and Ancillary Services markets and also improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

An Assessment of Impacts on Electric End-Use Load Profile of a Typical Residential Building from a Ground Source Heat Pump Systems Integrated with Underground Thermal Energy Storage

Buildings are the primary users of electricity, and a considerable amount of electric energy consumed in residential and commercial buildings is for meeting thermal demands (e.g., space heating/cooling, water heating, etc.). Therefore, integrating thermal energy storage with a building’s energy system has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable power supply and the thermal demands of buildings. A novel ground-source heat pump system (GSHP) integrated with underground thermal energy storage (UTES) has been developed to enable flexible electric demand at buildings while meeting their thermal demands with an energy-efficient GSHP system. This paper assessed the potential impacts of the proposed system on the peak electrical demand and annual electricity consumption in a typical residential building at various climate zones in the United States. The results show that by replacing the conventional HVAC system (air conditioner and natural gas furnace) with the UTES integrated GSHP system, summer peak electric demand can be reduced by 27% to 50% depending on the weather. Although the winter peak electrical demand could be increased by up to 70% if the proposed system replaces natural gas furnace, the existing electricity supply system for single-family homes in most regions of the United States have adequate capacity for the replacement. While eliminating the natural gas consumption for space heating, the proposed system consumes more electricity on an annual basis in heating-dominated regions. However, it consumes less electricity in cooling dominated regions. The resulting variance in annual electricity consumption in various climate zones is within 15% compared with the baseline system.

Shi, Liang↗

Renewable Thermal Hybridization Framework for Industrial Process Heat Applications

Renewable thermal energy systems (RTES) could be hybridized with different renewable options (e.g., flat plate collectors (FPCs) with parabolic collectors), or combined with existing heat supplies (e.g., fossil fuels), to give options for targeted solar IPH applications, industrial decarbonization and the reduction of fuel consumption. Buildings and industrial thermal energy applications require different temperature ranges, quantities, and rates of thermal energy, and as such require flexible, cost competitive solutions, able to provide heat over various temperature ranges. Hybrid solutions and thermal energy storage (TES) will be important for the dispatch of heat at optimal times needed by the demand side of the buildings and industrial applications. A variety of tools and platforms, such as the System Advisor Model (SAM), can provide hourly thermal yield simulations from single renewable energy (RE) technology options, including FPCs or CSP for solar IPH. We have investigated a variety of approaches to hybrid system modeling for RTES at different temperatures or combinations of technologies and developed an initial framework. The hybridization framework starts by creating a heat stream and raising the temperature of that heat stream by various combinations of RE technologies and other sources such as fossil fuels, new fuels or electric heating in multiple stages, with options for TES and/or waste heat recovery (WHR).

43 PARTICLE ACCELERATORS↗

Flexible Nuclear Energy for Clean Energy Systems

As part of the Nuclear Innovation: Clean Energy Future initiative, this report describes flexibility in nuclear systems, the value it can bring, and international experiences surrounding flexible nuclear energy. Flexible nuclear energy for this report is defined as “The ability of nuclear energy generation to economically provide energy services at the time and location they are needed by end-users. These energy services can include both electric and non-electric applications utilizing both traditional nuclear power plants and advanced integrated systems.” Flexibility in nuclear systems is enabled by three main mechanisms: core ramping, integrated energy systems with multiple byproducts, and thermal storage. The value of this flexibility on a $\$$/MW and a $\$$/MWh basis can be estimated through a combination of physics and economics modeling. International agencies describe their experiences in operating flexible nuclear systems and describe their plans for increasing nuclear flexibility in a clean energy system, likely with a high penetration of variable renewable energy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Enhancing actuation control in monolithic liquid crystal elastomer films with dual heat and light responsiveness

This study presents a dual heat and light-responsive monolithic liquid crystal elastomers (LCEs) film designed to enhance actuation control. The LCE films were capable of various motion types, including curvature reversal, oscillation, and sustainable flipping. By incorporating an azobenzene compound, the films exhibited additional functionalities such as enhanced curvature reversal, accelerated oscillation, and the ability to lock continuous flipping motion upon light stimulation. Furthermore, by adjusting the aspect ratio (AR) of a single film, different thermal motion states were realized, demonstrating the flexibility of this approach. Observations using an NIR camera confirmed temperature fluctuations corresponding to thermal exchange, and the influence of UV light on motion regulation was quantitatively analyzed. In conclusion, the ability to regulate motion through dual stimuli paves the way for improved dynamic motion control and thermal management in advanced robotic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermally Insulating Transparent Barrier (THINNER) coatings on single pane windows

Conventional silica aerogel monoliths can provide remarkable thermal insulation but the presence of large pores (> 30 nm) tends to scatter visible light and render the material opaque or translucent instead of transparent. In addition, they are prone to cracking during synthesis and handling which makes them difficult to integrate in products and in particular in window solutions. This project developed two new solgel synthesis methods using silica precursors or preformed silica nanoparticles and ambient drying to produce mesoporous organo-silica monoliths. The monoliths were (i) thermally insulating, (ii) optically transparent, (iii) flexible, and (iv) hydrophobic. They feature porosity ranging from 50% to 90% with narrow pore size distribution with pore less than 20 nm resulting in excellent optical clarity (haze < 2%) and very low thermal conductivity (< 30 mW/mK). Interestingly, not only porosity but also pore size and mass fractal dimension were found to affect the thermal conductivity of the mesoporous silica. The superior transparency of the monoliths was shown to be attributed to dependent scattering among silica nanoparticles. Flexibility was achieved through trimethylchlorosilane surface modification. Furthermore, process scale-up and integration of the ambigel monoliths into window solutions using optically clear adhesives were also demonstrated in 6”x6” double-pane windows. The aerogel and the window solution were shown to be durable to accelerated aging under UV, moisture, and/or temperature gradient and thermal cycling. Overall, the window solution achieved the technical performance and the cost target of $10/sqft set for the SHIELD program. However, scaling to industry relevant scale (> 10’x10’) remains a challenge due to requirements on the drying process and fume hood size and to the propensity of large aerogel slab to crack during drying.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identifying Regions Favorable for Geothermal Heating and Cooling Storage

Space heating and cooling represents the single largest category of in building energy use for U.S. residential and commercial buildings, with heating representing 61% of residential and 46% commercial energy consumption. Building heating technologies are dominated by natural gas technologies, and are an important opportunity for building electrification to enable a transition to a low CO 2 energy system. FLXenabler study is a joint analysis effort among multiple analysis teams at NREL and focused on examining the role of geothermal heating and cooling (GHC) system with thermal energy storage (TES) providing flexibility. Utilizing information from ResStock the amount of energy consumption associated with heating and cooling by state was calculated. We applied adjusted load shapes to estimate the a maximum grid savings potential of using TES to address building space conditioning. Normalizing grid, fuel, and emissions impacts locations with higher favorability for further study in FLXenabler were identified.

15 GEOTHERMAL ENERGY↗

Hierarchical Model-Free Transactional Control of Building Loads to Support Grid Services

A transition from generation on demand to consumption on demand is one of the solutions to overcome the many limitations associated with the higher penetration of renewable energy sources. Such a transition, however, requires a considerable amount of load flexibility in the demand side. Demand response (DR) programs can reveal and utilize this demand flexibility by enabling the participation of a large number of grid-interactive efficient buildings (GEB). Existing approaches on DR require significant modelling or training efforts, are computationally expensive, and do not guarantee the satisfaction of end users. To address the aforementioned limitations, this software code considers a scalable hierarchical model-free transactional control approach that incorporates elements of virtual battery, game theory, and model-free control (MFC) mechanisms. The developed approach separates the control mechanism into upper and lower levels. The MFC modulates the flexible GEB in the lower level with guaranteed thermal comfort of end users in response to the optimal pricing and power signals determined in the upper layer using a Stackelberg game integrated with aggregate virtual battery constraints. Additionally, the usage of MFC necessitates less burdensome computational and communication requirements, thus, it is easily deployable even on small, embedded devices. This software code enables the use of residential and small-size commercial buildings to offer a potentially substantial source of ancillary grid services that are currently underutilized. A hierarchical, model-free transactive building control provides a smooth interface between the grid service requests of utilities and the reliable control required by participating buildings. Model-free control, which supports distributed control architecture, will be a more scalable solution that can be deployed in neighborhood-size systems as well as individual buildings. The proposed approach contributes to the body of knowledge on two main aspects. First, it couples the MFC with the game-theoretic control and proposes a scalable model-free transactive control approach. MFC does not require any modeling effort or model training for the various building loads. This is very beneficial since deriving an accurate model for every single unit participating in DR programs and obtaining all the parameters about the units (e.g., thermal coefficients, standby losses) are infeasible. Also, MFC is computationally efficient, easily deployable even on small, embedded devices, and can be implemented in real time. Second, it integrates the concept of virtual battery into DR via the Stackelberg game. The concept of virtual battery enables efficient coordination and aggregation of a large number of flexible GEB with guaranteed thermal comfort of end users.

Olama, Mohammed [Oak Ridge National Lab. (ORNL), O↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Flexibility of oxygen sublattice and hydrogen bond length predict proton mobility in ternary metal oxides

Discovery of fast proton conductors is important for advancing clean energy technologies. This requires a better understanding of proton migration mechanisms. While structural and chemical traits of ternary metal oxides have been related to proton migration barriers, lattice dynamical effects have not been resolved quantitatively. Here, in this work, we introduce a phonon-based dynamic descriptor, termed ‘‘thermal O…O fluctuation,’’ quantifying the flexibility of donor-acceptor oxide-ion pairs. This enables direct comparison of O-sublattice flexibility across diverse metal oxides. Using regression models, we ranked physical descriptors as predictors of proton mobility, finding that H-bond length and thermal O…O fluctuation were the strongest descriptors. Further analysis revealed a critical O…O spacing of 2.4 A˚ at the transition state, which is easier to reach by more flexible donor-acceptor pairs, enabling facile proton transfer. Our results demonstrate oxygen sublattice flexibility as a dynamic descriptor and provide guiding principles for enhancing proton mobility in ternary metal oxides.

diffusivity↗

Evaluation of Phase Change Plaster/Paste Composites for Building Envelopes

Thermal energy storage (TES) materials increase a building’s thermal mass and provide the flexibility to shave and time-shift energy use. These materials are needed to enable grid-interactive efficient buildings, allowing building occupants to lower costs by leveraging free ambient heating/cooling as well as shifting consumption to cheaper electricity periods. Phase change materials (PCMs) that store heat through a solid-liquid/solid-solid transformation are of particular interest for TES because of their ability to store large amounts of energy across a constant temperature or very small temperature range. Furthermore, previous studies on PCM building envelopes evaluated products that may only be incorporated as part of new construction and are not easily applicable to existing, energy-intensive buildings. In this work, we leverage laboratory PCM characterization and whole-building energy simulation to study the energy and cost savings of PCM plaster/paste coatings, which can be applied post construction to both new builds and retrofits of existing buildings (about 40% of residential buildings in the United States fall into the retrofit category). We evaluated the energy impact of PCM plaster/paste composites for a single-family residential building in the United States, including layer design (location and thickness), composite properties (phase change temperature, energy density, and shape of the enthalpy curve), and U.S. climate zone. The enthalpy curve shape of PCM shows that phase change temperature and energy density are not the only two parameters that must be considered for PCM selection. Maximizing the energy density amid the effective TES zone is key to boosting energy savings. We also studied PCM price targets with the aim of achieving reasonable payback periods based on both block and time-of-use electricity rates. Moreover, we developed an empirical equation to provide a rough estimate of the energy savings potential of incorporating PCM without the need to perform detailed simulations. These results will help guide the selection and design of PCM plaster/paste composite elements for residential building envelopes.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗