At least 109 records · Page 6

Projecting the Thermal Response in a HTGR-Type System during Conduction Cooldown Using Graph-Laplacian Based Machine Learning

Accurate prediction of an off-normal event in a nuclear reactor is dependent upon the availability of sensory data, reactor core physical condition, and understanding of the underlying phenomenon. This work presents a method to project the data from some discrete sensory locations to the overall reactor domain during conduction cooldown scenarios similar to High Temperature Gas-cooled Reactors (HTGRs). The existing models for conductive cooldown in a heterogeneous multi-body system, such as an assembly of prismatic blocks or pebble beds relies on knowledge of the thermal contact conductance, requiring significant knowledge of local thermal contacts and heat transport possibilities across those contacts. With a priori knowledge of bulk geometry features and some discrete sensors, a machine learning approach was devised. The presented work uses an experimental facility to mimic conduction cooldown with an assembly of 68 cylindrical rods initially heated to 1200 K. High-fidelity temperature data were collected using an infrared (IR) camera to provide training data to the model and validate the predicted temperature data. The machine learning approach used here first converts the macroscopic bulk geometry information into Graph-Laplacian, and then uses the eigenvectors of the Graph-Laplacian to develop Kernel functions. Support vector regression (SVR) was implemented on the obtained Kernels and used to predict the thermal response in a packed rod assembly during a conduction cooldown experiment. The usage of SVR modeling differs from most models today because of its representation of thermal coupling between rods in the core. When trained with thermographic data, the average normalized error is less than 2% over 400 s, during which temperatures of the assembly have dropped by more than 500 K. The rod temperature prediction performance was significantly better for rods in the interior of the assembly compared to those near the exterior, likely due to the model simplification of the surroundings.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

THE EFFECT OF INCREASING TEMPERATURE ON K-EFF FOR FISSILE MATERIAL OUTSIDE REACTORS

Nuclear Criticality Safety Evaluations typically employ room temperature cross sections, material densities, and dimensions. Processes that have been and are in development for conversion of legacy wastes in tanks, e.g., Waste Treatment Project (WTP) at the Hanford Remediation Site and Defense Waste Processing Facility (DWPF) at the Savannah River Site, utilize melters that operate at elevated temperatures, 1500 to 1900 C. The applicability of room temperature data to processes such as these has been questioned. Also questioned was the applicability of room temperature data for the analyses across the Savannah River Site (SRS) where the temperature may be elevated, such as in a postulated fire. This analysis was performed to examine the effect of temperature over the relatively small range encountered in normal and abnormal operations at SRS that does not include DWPF melters. This analysis documented herein is limited to fast systems of fissile metal and oxide cylinders on concrete at temperatures no greater than 640 C, the melting point of plutonium. Because thermal expansion data for various types of structural materials was not readily available, structural materials were not included in the analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Surface Temperature Mapping Models for STAR and CTF

This milestone presents a demonstration of a surface mapping model to map the surface temperature for single-phase STAR-CCM+ to Cobra-TF using average temperature data. This model can be used to generate high-resolution surface temperature data. This can be accomplished with linear equations or with an alternative non-linear model. Improvements and a path forward for the surface mapping model to be applied to two-phase temperature mappings is also laid out in this milestone report.

42 ENGINEERING↗

Quantifying impacts of heat waves on power grid operation

Climate change is projected to cause an increase in the severity and frequency of extreme weather events such as heat waves and droughts. Such changes present planning and operating challenges and risks to many economic sectors. In the electricity sector, statistics of extreme events in the past have been used to help plan for future peak loads, determine associated infrastructure requirements, and evaluate operational risks, but industry-standard planning tools have yet to be coupled with or informed by temperature models to explore the impacts of the "new normal" on planning studies. For example, high ambient temperatures during heat waves reduce the output capacity and efficiency of gas fired combustion turbines just when they are needed most to meet peak demands. This paper describes the development and application of a production cost and unit commitment model coupled to high resolution, hourly temperature data and a temperature dependent load model. The coupled system has the ability to represent the impacts of hourly temperatures on load conditions and available capacity and efficiency of combustion turbines, and therefore capture the potential impacts on system reliability and production cost. Ongoing work expands this capability to address the impacts of water availability and temperature on power grid operation.

Climate change↗

Ion beam irradiation of ABO4 compounds with the fergusonite, monazite, scheelite, and zircon structures

The effects of irradiation on CaWO4, SrWO4, BaWO4, YVO4, LaVO4, YNbO4, and LaNbO4 were investigated on thin crystals using 1.0 MeV Kr ions at 50-1000 K. All of the ABO4 compounds can be amorphized with calculated damage cross sections (σa = 1/Fc0) in the range of ~0.30-1.09 × 10-14 cm2 ion-1 at zero Kelvin. The analysis of fluence-temperature data returned critical temperatures for amorphization (Tc) of 311 ± 1, 358 ± 90, 325 ± 19, 415 ± 17, 541 ± 6, 636 ± 26, and 1012 ± 1 K, respectively, for the compounds listed above. Compared with previous in situ irradiation of ABO4 orthophosphate samples using 0.8 MeV Kr ions, the Tc values of LaVO4 and YVO4 are higher than those of LaPO4 and YPO4 by 82 K and 124 K, respectively. The Tc values of the three scheelite structures, CaWO4, SrWO4, and BaWO4, indicate that they are the most radiation tolerant compounds under these conditions. The A-B cation anti-site energies, EfAB, determined by DFT range from 2.48 to 10.58 eV and are highly correlated with the A-B cation ionic radius ratio, rA/rB, but are not correlated with Tc across the different structure types, suggesting that the formation and migration energies of Frenkel defects play a more important role in damage recovery in these compounds. We also discuss the role of cation and anion charge/iconicity as determined by DFT. ABO4 compounds with the zircon structure and B = P or V have a distinct advantage over those with B = Si as the damaged regions do not appear to be significantly affected by polymerization of (PO4) 3- or (VO4) 3- groups which might stabilize the amorphous fraction and ultimately lead to phase separation as observed in zircon (ZrSiO4).

amorphization↗

Method and apparatus for providing wear leveling

Exemplary embodiments provide wear spreading among die regions (i.e., one or more circuits) in an integrated circuit or among dies by using operating condition data in addition to or instead of environmental data such as temperature data, from each of a plurality of die regions. Control logic produces a cumulative amount of time each of the plurality of die regions has spent at an operating condition based on operating condition data wherein the operating condition data is based on at least one of the following operating characteristics: frequency of operation of the plurality of die regions, an operating voltage of the plurality of die regions, an activity level of the plurality of die regions, a timing margin of the plurality of die regions, and a number of detected faults of the plurality of die regions. The method and apparatus spreads wear among the plurality of same type of die regions by controlling task execution among the plurality of die regions using the die wear-out data.

Raasch, Steven↗

Report priority gaps in high temperature thermodynamic data (Interim Progress Report)

This interim progress report (Level 4 Milestone Number M4SF-26LL010203023) summarizes research conducted at Lawrence Livermore National Laboratory (LLNL) within the Argillite Host Rock Properties & Processes SF-26LL01020302. Our focus is to assess gaps in data availability and understanding for radionuclide thermodynamics within the context of a “hot repository” concept and expand SUPCRT-NE database development to address higher temperatures needed for a DPC DGR disposal concept. The database is intended to inform the argillite GDSA baseline model. The leading European thermochemical database (Thermochimie) is only applicable to temperatures below 80°C. Thus, a US effort to integrate and expand upon other international thermodynamics database efforts is needed, particular if a “hot repository” concept moves forward.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geologic Map and Cross Sections of the McGinness Hills Geothermal Area - GIS Data

Geologic map data in shapefile format that includes faults, unit contacts, unit polygons, attitudes of strata and faults, and surficial geothermal features. 5 cross-sections in Adobe Illustrator format. Comprehensive catalogue of drill-hole data in spreadsheet, shapefile, and Geosoft database formats. Includes XYZ locations of well heads, year drilled, type of well, operator, total depths, well path data (deviations), lithology logs, and temperature data. 3D model constructed with EarthVision using geologic map data, cross-sections, drill-hole data, and geophysics.

15 GEOTHERMAL ENERGY↗

The Sensitivity of PBX 9502 to Drilling Operations

Polymer-bonded explosive (PBX) 9502 (95% TATB, 5% Kel-F 800 by weight) is dry-drilled on a CNC milling machine and its thermomechanical response to varying feed rates, drilling speeds, and peck depths with 4 mm and 5 mm diameter drill bits is investigated. The tested samples are affixed to a force sensor that enables recording temporally resolved cutting forces and torques, and a drill-embedded thermocouple yields local temperature data. From the data, an empirical relationship between temperature changes and feed per revolution is developed, which reveals reduced temperatures in higher feed per revolution regimes for PBX 9502. The observed relationship allows extrapolating to temperatures for other hole diameters, indicating increased temperature for smaller diameter drilling across the board. Additional testing was performed with PBX 9501 (95% HMX, 2.5% Estane®, 2.5% BDNPA/BDNPF by weight), albeit over a reduced parameter space, which revealed the opposite behavior for the feed per revolution temperature dependence. It is concluded that both PBX 9502 and PBX 9501 can be dry-drilled efficiently beyond the limits of presently applicable US-DOE standards, where cutting interface temperatures remain far below material critical temperatures. Finally, data reveals that coolant usage in the drilling process for these materials provides a wide safety margin.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A global urban heat island intensity dataset: Generation, comparison, and analysis

The urban heat island (UHI) effect, a phenomenon of local warming over urban areas, is the most well-known impact of urbanization on climate. Globally consistent estimates of the UHI intensity (UHII) are crucial for examining this phenomenon across time and space. However, publicly available UHII datasets are limited and have several constraints: (1) they are for clear-sky surface UHII, not all-sky surface UHII and canopy (air temperature) UHII; (2) the estimation methods often neglect anthropogenic disturbance, introducing uncertainties in the estimated UHII. To address these issues, this study proposes a new dynamic equal-area (DEA) method that can minimize the influence of various confounding factors on UHII estimates through a dynamic cyclic process. Utilizing the DEA method and leveraging various gridded temperature data, we develop a global-scale (>10,000 cities), long-term (over 20 years by month), and multi-faceted (clear-sky surface, all-sky surface, and canopy) UHII dataset. Further, based on these estimates, we provide a comprehensive analysis of the UHII and its trends in global cities. The UHII is found to be greater than zero in >80% of cities, with global annual average magnitudes around 1.0 °C (day) and 0.8 °C (night) for surface UHII, and close to 0.5 °C for canopy UHII. Furthermore, an interannual upward trend in UHII is observed in >60% of cities, with global annual average trends exceeding 0.1 °C/decade (day) and over 0.06 °C/decade (night) for surface UHII, and slightly surpassing 0.03 °C/decade for canopy UHII. Notably, there exists a positive correlation between the magnitude and trend of UHII, suggesting that cities with stronger UHII tend to experience faster growth in UHII. Additionally, discrepancies in UHII are found between different temperature data, stemming not only from distinctions in data types (surface or air temperature) but also from differences in data acquisition times (Terra or Aqua), weather conditions (clear-sky or all-sky), and processing methodologies (with or without gap filling). Overall, our proposed method, dataset, and analysis results have the potential to provide valuable insights for future urban climate studies. The UHII dataset is publicly available at https://doi.org/10.6084/m9.figshare.24821538.

54 ENVIRONMENTAL SCIENCES↗

Impact of refrigerant undercharge faults on building indoor conditions and HVAC system operation in residential Buildings: A simulation study

This study investigates the impact of refrigerant undercharge on indoor temperature and HVAC system performance in residential buildings. Simulation models for typical residential buildings in Orlando, FL and Indianapolis, IN were developed using the ResStock database. A refrigerant undercharge fault model was then applied to the simulations with varying levels of fault intensity. The paper offers an extensive analysis, revealing that variations in supply air temperature, equipment runtime, and cooling energy consumption due to the level of refrigerant undercharge faults are notably significant on a summer representative day. Similarly, on a winter representative day, changes in supply air temperature and runtime are significant as well as changes in supplemental heat energy consumption. We find that occupants may remain oblivious to these faults during the cooling season, particularly when the HVAC system is oversized; in that case, supply air temperature data could help detect a fault. Another challenge is that during the heating season, when the supplemental heater operates, it is difficult to identify a refrigerant undercharge fault using only indoor and supply air temperature data. Finally, this study finds that supply air temperature, equipment runtime, and supplemental heater energy consumption data can help in detecting refrigerant undercharge faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct Measurement of EGR Cooler Deposit Thermal Properties for Improved Understanding of Cooler Fouling

Exhaust gas recirculation (EGR) cooler fouling has become a significant issue for compliance with NOx emissions standards. This paper reports results of a study of fundamental aspects of EGR cooler fouling. An apparatus and procedure were developed to allow surrogate EGR cooler tubes to be exposed to diesel engine exhaust under controlled conditions. The resulting fouled tubes were removed and analyzed. Volatile and non-volatile deposit mass was measured for each tube. Thermal diffusivity of the deposited soot cake was measured by milling a window into the tube and using the Xenon flash lamp method. The heat capacity of the deposit was measured at temperatures up to 430°C and was slightly higher than graphite, presumably due to the presence of hydrocarbons. These measurements were combined to allow calculation of the deposit thermal conductivity, which was determined to be 0.041 W/mK, only ~1.5 times that of air and much lower than the 304 stainless steel tube (14.7 W/mK). The main determinant of the deposit thermal conductivity is density, which was measured to be just 2% that of the density of the primary soot particles (or 98% porous). The deposit layer thermal resistance was calculated and compared with estimates of the thermal resistance calculated from gas temperature data during the experiment. The deposit properties were also used to further analyze the temperature data collected during the experiment.

33 ADVANCED PROPULSION SYSTEMS↗

Colorado Heat Flow Data from IHFC

This layer contains the heat flow sites and data of the State of Colorado compiled from the International Heat Flow Commission (IHFC) of the International Association of Seismology and Physics of the Earth's Interior (IASPEI) global heat flow database. The data include different items: Item number, descriptive code, name of site, latitude and longitude, elevation, depth interval, number of temperature data, temperature gradient, number of conductivity measurement, average conductivity, number of heat generation measurements, average heat production, heat flow, number of individual sites, references, and date of publication.

15 GEOTHERMAL ENERGY↗

APASS Landolt-Sloan BVgri photometry of Rave stars. I. Data, effective temperatures, and reddenings

We provide AAVSO Photometric All-Sky Survey (APASS) photometry in the Landolt BV and Sloan g'r'i' bands for all 425,743 stars included in the fourth RAVE Data Release. The internal accuracy of the APASS photometry of RAVE stars, expressed as the error of the mean of data obtained and separately calibrated over a median of four distinct observing epochs and distributed between 2009 and 2013, is 0.013, 0.012, 0.012, 0.014, and 0.021 mag for the B, V, g', r', and i' bands, respectively. The equally high external accuracy of APASS photometry has been verified on secondary Landolt and Sloan photometric standard stars not involved in the APASS calibration process and on a large body of literature data on field and cluster stars, confirming the absence of offsets and trends. Compared with the Carlsberg Meridian Catalog (CMC-15), APASS astrometry of RAVE stars is accurate to a median value of 0.098 arcsec. Brightness distribution functions for the RAVE stars have been derived in all bands. APASS photometry of RAVE stars, augmented by 2MASS JHK infrared data, has been χ{sup 2} fitted to a densely populated synthetic photometric library designed to widely explore temperature, surface gravity, metallicity, and reddening. Resulting T {sub eff} and E {sub B–V}, computed over a range of options, are provided and discussed, and will be kept updated in response to future APASS and RAVE data releases. In the process, we find that the reddening caused by a homogeneous slab of dust, extending for 140 pc on either side of the Galactic plane and responsible for E{sub B−V}{sup poles} = 0.036 ± 0.002 at the Galactic poles, is a suitable approximation of the actual reddening encountered at Galactic latitudes |b| ≥ 25°.

79 ASTRONOMY AND ASTROPHYSICS↗

Fracture Characterization Via AI‐Assisted Analysis of Temperature Logs

Abstract Fractures control fluid flow, mass transport, and heat transfer in a geothermal reservoir. This makes accurate characterization of fracture networks a prerequisite for optimal design and control of a reservoir's exploitation. We develop a deep‐learning procedure to identify fracture locations via interpretation of temporally and spatially continuous downhole temperature measurements. A long short‐term memory fully convolutional network (LSTM‐FCN) is used both to capture long‐term dependencies in sequential temperature data and to distill local features around fractures. A wellbore and fractured‐reservoir thermal model is established to generate temperature data for network training. The trained LSTM‐FCN exhibits a unique ability to detect multiple fractures intersecting a borehole. We use the LSTM‐FCN algorithm to evaluate the effectiveness of different‐stage wellbore temperature measurements on fracture detection in a complex fractured system. Our experiments reveal that the use of various‐stage temperature information as an input feature set improves the robustness of fracture detection to noise interference. This study indicates the practical feasibility of obtaining accurate fracture‐network reconstructions from temperature signals, at reasonable computational cost.

Yang, Xiaoyu↗

Removing Rotational Variations from Shoulder Thermocouples in Friction Stir Welding

Thick plate and lower temperature friction stir welding results in good post-weld properties by welding at very low tool rotational speeds. Low speeds cause large variations in the measured shoulder temperature, making temperature control difficult. This paper describes a computationally light method to correct for oscillating measured temperatures. Data is collected over the previous two revolutions and used to build a compensation table and calculate a derivative. In simulation, measured temperature variations are reduced by a factor of five to ten. Temperature data is preserved and not cornered, nor is any time delay induced by this method, unlike with filtering methods.

Friction Stir Welding, Temperature↗

Melting/freezing points of high concentrations of AlCl 3 in a saturated chloroaluminate ionic liquid

Melting/freezing points of AlCl 3 in saturated chloroaluminate ionic liquids [molar ratio 2:1 AlCl 3 :1-ethyl-3-methyl imidazolium chloride (EMIC)] are measured by differential scanning calorimetry (DSC). A critical range of temperature data (50-130 °C) for AlCl 3 dissolution and precipitation from saturated chloroaluminate ionic liquids is obtained. This range of temperature data is of significance to control phase transition of AlCl 3 in saturated chloroaluminate ionic liquids. By applying the chloroaluminate ionic liquids to electrolytes for energy storage usage, solid AlCl 3 can be partially dissolved and precipitated out during the charging/discharging cycle of energy storage equipment. Furthermore, the energy density of the electrolytes is expected to be greatly improved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Imaging Fluid Flow in Geothermal Wells Using Distributed Thermal Perturbation Sensing

The objective of Task 2 is to develop a numerical method for the efficient and accurate analysis of distributed thermal perturbation sensing (DTPS) data for (1) imaging flow profiles and (2) in situ determination of thermal conductivities and heat fluxes. Numerical forward and inverse modeling is employed to: (1) Examine heat and fluid flow processes near a geothermal well under heating and cooling conditions; (2) Demonstrate ability to interpret DTPS thermal profiles with acceptable estimation uncertainty using inverse modeling of synthetic temperature data; and (3) Develop template model and analysis procedure for the inversion of temperature data collected during a thermal perturbation test using fiber-optic distributed temperature sensors. This status report summarizes initial model developments and analyses.

54 ENVIRONMENTAL SCIENCES↗