Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Optimal read/write memory system components

Two holographic data storage and display systems, voltage gradient ionization system, and linear strain manipulation system are discussed in terms of creating fast, high bit density, storage device. Components described include: novel mounting fixture for photoplastic arrays; corona discharge device; and block data composer.

Kozma, A.↗

Safety management of complex research operators

Complex research and technology operations present varied potential hazards which are addressed in a disciplined, independent safety review and approval process. Potential hazards vary from high energy fuels to hydrocarbon fuels, high pressure systems to high voltage systems, toxic chemicals to radioactive materials and high speed rotating machinery to high powered lasers. A Safety Permit System presently covers about 600 potentially hazardous operations. The Safety Management Program described is believed to be a major factor in maintaining an excellent safety record.

Brown, W. J.↗

Safety management of complex research operations

Complex research and technology operations present many varied potential hazards which must be addressed in a disciplined independent safety review and approval process. The research and technology effort at the Lewis Research Center is divided into programmatic areas of aeronautics, space and energy. Potential hazards vary from high energy fuels to hydrocarbon fuels, high pressure systems to high voltage systems, toxic chemicals to radioactive materials and high speed rotating machinery to high powered lasers. A Safety Permit System presently covers about 600 potentially hazardous operations. The Safety Management Program described in this paper is believed to be a major factor in maintaining an excellent safety record at the Lewis Research Center.

Brown, W. J.↗

Establishment of a PID Pass/Fail Test for Crystalline Silicon Modules by Examining Field Performance for Five Years: Preprint

In an experiment with five module designs and multiple replicas, it is found that crystalline silicon cell modules that can pass a criterion of less than 5 percent power degradation in stress test conditions of 60 degrees Celsius, 85 percent relative humidity (RH), 96 h, and nameplate-rated system voltage bias show no power degradation by potential induced degradation in the range of 4-6 years duration in the Florida, USA environment. This data suggests that this chamber stress level is useful as a pass/fail criterion for PID, and will help ensure against degradation by system voltage stress in Florida, or less stressful climates, for at least 5 years.

14 SOLAR ENERGY↗

Skylab high voltage electrical/electronic systems corona assessment.

Six significant design parameters which must be considered in the corona assessment include the operating voltage, radio frequency power, the 'pressure times spacing' relation, operating temperature, gases and contaminants in the environment, and configuration and field gradients. An equipment and experiments survey is presented, giving attention to corona-free equipment and equipment requiring detailed investigations.

Dunbar, W. G.↗

System for instrumenting and manipulating apparatuses in high voltage

A system for energizing, operating and manipulating apparatuses in high voltage systems. The system uses a dielectric gas such as SF.sub.6 as a driving power supply for a pneumatic motor which ultimately charges a battery or other energy storage device. The stored energy can then be used for instrumentation equipment, or to power any electrical equipment, in the high voltage deck. The accompanying method provides for the use of the SF6 system for operating an electrical device in a high-voltage environment.

25 ENERGY STORAGE↗

NASCAP modelling of high-voltage power system interactions with space charged-particle environments

A simple space power system operating in geosynchronous orbit was analyzed. This system consisted of two solar array wings and a central body. Each solar array wing was considered to be divided into three regions operating at 2000 volts. The center body was considered to be an electrical ground with the array voltages both positive and negative relative to ground. The system was analyzed for both a normal environment and a moderate geomagnetic substorm environment. Initial results indicate a high probability of arcing at the interconnects on the negative operating voltage wing. The dielectric strength of the substrate may be exceeded giving rise to breakdown in the bulk of the material. The geomagnetic substorm did not seem to increase the electrical gradients at the interconnects on the negative operating voltage wing but did increase the gradients on the positive operating voltage wing which could result in increased coupling current losses.

Stevens, N. J.↗

TPCPF: Three-Phase Continuation Power Flow Tool for Voltage Stability Assessment of Distribution Networks With Distributed Energy Resources

This article presents a three-phase unbalanced continuation power flow algorithm for voltage stability assessment of distribution systems with high penetration of distributed energy resources (DERs). Analyzing distribution system voltage stability with DER will allow high penetration of renewable energy necessary for the sustainability goals. The developed algorithm can analyze voltage stability for both the meshed and radial systems and the balanced and unbalanced three-phase distribution systems. The developed tool allows the voltage stability analysis to facilitate the planning, operation, control, and distribution system management. The impact of DER on the voltage stability of several test cases has been analyzed considering constant power (P Q) and regulated-voltage (P V ) modes of operation for DER units. Moreover, different voltage stability case studies are presented to demonstrate the impact of unbalance, load increment, and network topology on the maximum loading capacity. Finally, results using the IEEE 13-node feeder, the 18-bus balanced shipboard system, the 13-node CIGRE benchmark system, and the 136-bus redial distribution feeder demonstrate that the developed continuation power flow tool can efficiently perform voltage stability analysis for active distribution systems.

42 ENGINEERING↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Interfacial Characterization of Positive Bias Voltage Degradation in PV Modules

Degradation from high system voltage is a prevailing failure mode in fielded photovoltaic modules, and the degradation mechanism is inherently dependent on the bias polarity. Here we report the effects of positive bias. Modules under positive bias demonstrated a significant photocurrent loss caused by two routes. First, delamination and discoloration of the silicon nitride layer, leading to optical loss determined by reflectance measurements. Second, chemical discoloration of the cell gridlines and encapsulant (EVA), which is linked to an electrochemical reaction at the silver electrodes. Chemical compositional analysis using X-ray photoemission spectroscopy demonstrated that the discoloration is attributed to Ag 2 S and/or Ag 2 O. Evidence of Ag ion migration from the cell grid into the encapsulant is observed after shallow depth profiling on the EVA surface. However, Ag was not detected at the EVA/glass interface, inferring limited Ag ion transport through the EVA. The source of sulfur is believed to be ambient air, which diffused into the module through the breathable backsheet.

characterization↗

Adaptive Control Algorithm to Adjust Settings in Photovoltaic Inverters for Electric Grid Cybersecurity (DERAC) v0.1

Volt-VAR and Volt-Watt functionality in photovoltaic (PV) smart inverters provide mechanisms to ensure system voltage magnitudes and power factors remain within acceptable limits. However, these control functions can become unstable, introducing oscillations in system voltages when not appropriately configured or maliciously altered during a cyberattack. In the event that Volt-VAR and Volt-Watt control functions in a portion of PV smart inverters in a distribution grid are unstable, the proposed adaptation scheme utilizes the remaining and stably-behaving PV smart inverters and other Distributed Energy Resources to mitigate the effect of the instability in real-time. The adaptation mechanism is entirely decentralized, model-free, communication-free, and requires virtually no external configuration. This repository provides code to simulate the algorithm in experiments on the IEEE 37 node test feeder.

Arnold, Daniel↗

Understanding interfacial chemistry of positive bias high-voltage degradation in photovoltaic modules

Photovoltaic module degradation from a high system voltage is a prevalent degradation mode in the field, where the enabling degradation mechanisms are inherently dependent on the voltage bias polarity of the installed system. In this study, the effects of positive bias on module performance are confirmed and the underlying chemical degradation processes are more thoroughly investigated to reveal different degradation pathways from those previously reported in negative bias studies. When cells are under +1000 V stress, crystalline silicon mini-modules with poly(ethylene-co-vinyl acetate) (EVA) encapsulant demonstrated a significant photocurrent loss due to EVA discoloration and delamination from increased chemical reactivity at the front-side EVA/cell metallization interface. Brown discoloration of the EVA encapsulant near the cell gridlines is linked to an electrochemical reaction at the Ag gridlines under hot and humid conditions (85 °C, 85% relative humidity). Chemical compositional analysis using X-ray photoelectron spectroscopy (XPS) confirmed that the discoloration is attributed to the formation of silver sulfide (Ag 2 S) and/or silver oxide (Ag 2 O) species at the EVA/Ag gridline interface. The subsequent migration of Ag ions from the cell gridlines into the bulk of the EVA was evident from XPS depth profiling and optical microscopy. However, the Ag signal was not detected at the EVA/glass interface, inferring limited ionic transport through the nominally 0.45 mm thick encapsulant. For the samples studied herein, the sulfur is believed by the process of elimination to come from the ambient air, diffusing into the module through the permeable polymer backsheet.

14 SOLAR ENERGY↗

Investigation of high voltage spacecraft system interactions with plasma environments

An experimental investigation was undertaken for insulator and conductor test surfaces biased up to + or - 1kV in a simulated low earth orbit charged particle environment. It was found that these interactions are controlled by the insulator surfaces surrounding the biased conductors. For positive applied voltages the electron current collection can be enhanced by the insulators. For negative applied voltages the insulator surface confines the voltage to the conductor region. Understanding these interactions and the technology to control their impact on system operation is essential to the design of solar cell arrays for ion drive propulsion applications that use direct drive power processing.

Stevens, N. J.↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

grid-following inverter↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This presentation discusses the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

droop control↗

Considerations for a Standardized Test for Potential-Induced Degradation of Crystalline Silicon PV Modules (Presentation)

Over the past decade, there have been observations of module degradation and power loss because of the stress that system voltage bias exerts. This results in part from qualification tests and standards note adequately evaluating for the durability of modules to the long-term effects of high voltage bias that they experience in fielded arrays. This talk deals with factors for consideration,progress, and information still needed for a standardized test for degradation due to system voltage stress.

14 SOLAR ENERGY↗

Laboratory Testing of a Utility-Scale PV Inverter's Operational Response to Grid Disturbances

This paper provides experimental results of a utility-scale (500 kW) solar PV inverter during simulated grid disturbances. This device was tested using simulations of system voltage during three different disturbances; simulated distribution and transmission faults, and voltage records that were collected during the Blue Cut Fire Event. The methods used for testing the three different scenarios of grid disturbances are detailed and the test setup is described. Additionally, the test results for each of the grid events are provided and an analysis of the test results is given. The test results show that the tested PV inverter's response to grid disturbances depends in part on the fault-induced phase shift and harmonic content of the system voltage. These factors can impact the inverters ability to accurately calculate system frequency and can cause erroneous tripping on miscalculated frequency. The information provided in this paper can inform utilities, manufacturers, developers, and system planners of the potential performance of solar PV inverters during grid events.

14 SOLAR ENERGY↗

Results of IEC 62804 Draft Round Robin Testing (Presentation)

Three crystalline silicon module designs were distributed in five replicas each to five laboratories for testing according to the IEC 62804 (Committee Draft) system voltage durability qualification test for crystalline silicon photovoltaic (PV) modules. The stress tests were performed in environmental chambers at 60 degrees C, 85% relative humidity, 96 h, and with module nameplate system voltage applied.

14 SOLAR ENERGY↗