Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchronous generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The two-way time synchronization system via a satellite voice channel

A newly developed two-way time synchronization system is described in this paper. The system uses one voice channel at a SCPC satellite digital communication earth station, whose bandwidth is only 45 kHz, thus saving satellite resources greatly. The system is composed of one master station and one or several, up to sixty-two, secondary stations. The master and secondary stations are equipped with the same equipment, including a set of timing equipment, a synthetic data terminal for time synchronizing, and a interface unit between the data terminal and the satellite earth station. The synthetic data terminal for time synchronization also has an IRIG-B code generator and a translator. The data terminal of master station is the key part of whole system. The system synchronization process is full automatic, which is controlled by the master station. Employing an autoscanning technique and conversational mode, the system accomplishes the following tasks: linking up liaison with each secondary station in turn, establishing a coarse time synchronization, calibrating date (years, months, days) and time of day (hours, minutes, seconds), precisely measuring the time difference between local station and the opposite station, exchanging measurement data, statistically processing the data, rejecting error terms, printing the data, calculating the clock difference and correcting the phase, thus realizing real-time synchronization from one point to multiple points. We also designed an adaptive phase circuit to eliminate the phase ambiguity of the PSK demodulator. The experiments have shown that the time synchronization accuracy is better than 2 mu S. The system has been put into regular operation.

Heng-Qiu, Zheng↗

Advanced Propulsion Power Distribution System for Next Generation Electric/Hybrid Vehicle: Preliminary System Studies - Phase 1

The report essentially summarizes the work performed in order to satisfy the above project objective. In the beginning, different energy storage devices, such as battery, flywheel and ultra capacitor are reviewed and compared, establishing the superiority of the battery. Then, the possible power sources, such as IC engine, diesel engine, gas turbine and fuel cell are reviewed and compared, and the superiority of IC engine has been established. Different types of machines for drive motor/engine generator, such as induction machine, PM synchronous machine and switched reluctance machine are compared, and the induction machine is established as the superior candidate. Similar discussion was made for power converters and devices. The Insulated Gate Bipolar Transistor (IGBT) appears to be the most superior device although Mercury Cadmium Telluride (MCT) shows future promise. Different types of candidate distribution systems with the possible combinations of power and energy sources have been discussed and the most viable system consisting of battery, IC engine and induction machine has been identified. Then, HFAC system has been compared with the DC system establishing the superiority of the former. The detailed component sizing calculations of HFAC and DC systems reinforce the superiority of the former. A preliminary control strategy has been developed for the candidate HFAC system. Finally, modeling and simulation study have been made to validate the system performance. The study in the report demonstrates the superiority of HFAC distribution system for next generation electric/hybrid vehicle.

Bose, Bimal K.↗

AC/DC Power Systems with Applications for future Lunar/Mars base and Crew Exploration Vehicle

ABSTRACT The Power Systems branch at JSC faces a number of complex issues as it readies itself for the President's initiative on future space exploration beyond low earth orbit. Some of these preliminary issues - those dealing with electric power generation and distribution on board Mars-bound vehicle and that on Lunar and Martian surface may be summarized as follows: Type of prime mover - Because solar power may not be readily available on parts of the Lunar/Mars surface and also during the long duration flight to Mars, the primary source of power will most likely be nuclear power (Uranium fuel rods) with a secondary source of fuel cell (Hydrogen supply). The electric power generation source - With nuclear power being the main prime mover, the electric power generation source will most likely be an ac generator at a yet to be determined frequency. Thus, a critical issue is whether the generator should generate at constant or variable frequency. This will decide what type of generator to use - whether it is a synchronous machine, an asynchronous induction machine or a switched reluctance machine. The type of power distribution system - the distribution frequency, number of wires (3- wire, 4-wire or higher), and ac/dc hybridization. Building redundancy and fault tolerance in the generation and distribution sub-systems so that the system is safe; provides 100% availability to critical loads; continues to operate even with faulted sub-systems; and requires minimal maintenance. This report descril_es results of a summer faculty fellowship spent in the Power Systems Branch with the specific aim of investigating some of the lessons learned in electric power generation and usage from the terrestrial power systems industry, the aerospace industry as well as NASA's on-going missions so as to recommend novel surface and vehicle-based power systems architectures in support of future space exploration initiatives. A hybrid ac/dc architecture with source side and load side redundancies and including emergency generators on both ac and dc sides is proposed. The generation frequency is 400 Hz mostly because of the technology maturity at this frequency in the aerospace industry. Power will be distributed to several ac load distribution buses through solid state variable speed, constant frequency converters on the ac side. A segmented dc ring bus supplied from ac/dc converters and with the capability of connecting/disconnecting the segments will supply power to multiple de load distribution buses. The system will have the capability of reverse flow from dc to ac side in the case of an extreme emergency on the main ac generation side.

Chowdhury, Badrul H.↗

Wind sets from SMS images - An assessment of quality for GATE

The paper analyzes the accuracy, representativeness, and reproducibility of tracer winds in the 1974 GARP Atlantic Tropical Experiment whose data are used as ground truth. The tracer winds were generated by tracking clouds in SMS (Synchronous Meteorological Satellite) images. Data availability limits comparisons to satellite winds with ship winds at the surface and at 250 mb. Attention is focused on how accurately the cloud displacements can be measured and on the extent to which the cloud displacements represent the wind field. Operator errors in obtaining the cloud displacements are examined in a series of reproducibility tests and wind sets. Differences between proximate satellite and ship winds were all under 3 m/sec. Representativeness of cloud tracers for cumulus and cirrus level flow is found to be good within the accuracy of currently available ground truth data.

Suchman, D.↗

Redundant operation of counter modules

A technique for the redundant operation of counter modules is described. Redundant operation is maintained by detecting the zero state of each counter and clearing the other to that state, thus periodically resynchronizing the counters, and obtaining an output from both counters through AC coupled diode-OR gates. Redundant operation of counter flip flops is maintained in a similar manner, and synchronous operation of redundant squarewave clock generators of the feedback type is effected by connecting together the feedback inputs of the squarewave generators through a coupling resistor, and obtaining an output from both generators through AC coupled diode-OR gates.

Nagano, S.↗

Proposal for implementation of CCSDS standards for use with spacecraft engineering/housekeeping data

Many of today's low earth orbiting spacecraft are using the Consultative Committee for Space Data Systems (CCSDS) protocol for better optimization of down link RF bandwidth and onboard storage space. However, most of the associated housekeeping data has continued to be generated and down linked in a synchronous, Time Division Multiplexed (TDM) fashion. There are many economies that the CCSDS protocol will allow to better utilize the available bandwidth and storage space in order to optimize the housekeeping data for use in operational trending and analysis work. By only outputting what is currently important or of interest, finer resolution of critical items can be obtained. This can be accomplished by better utilizing the normally allocated housekeeping data down link and storage areas rather than taking space reserved for science.

Welch, Dave↗

Phase-Synchronized Modal Testing of Mirror Membrane

The research reports on the development of a whole-field, system-level interferometry technique having phase-synchronized data acquisition and adjustable phase triggering. The technique utilizes a Fizeau interferometer, arbitrary function generator, oscilloscope, trigger filter, and CCD camera to determine the out-of-plane modal frequencies of a thin, highly reflective membrane. The technique generates phase-adjustable CCD camera trigger signals that are synchronized to the audio frequency excitation signal. The surface figures from the resulting interferograms were evaluated with fringe-following software and compared against that of an ideal membrane vibrating at resonance.

Rogers, Ted↗

Comparison of Acoustic Models and Trajectory Generation Methods for an Acoustically-Aware Aircraft

Motivation - Noise management is one of the major barriers to Urban Air Mobility - Approaches to noise mitigation (non-exhaustive) - Vehicle configuration - Directivity control via propeller phase synchronization - Trajectory optimization Objective - Create framework for trajectory generation integrating location-based acoustic metrics and vehicle performance limitations - Multiple trajectory optimization methods and acoustic noise models - Mission-relevant constraints - Mission duration, airspace restrictions, ... - Vehicle dynamic constraints - Aircraft structural limitations, min/max airspeed, ... - Vehicle separation/obstacle avoidance - Acoustic constraints at a number of discrete observer locations

Kasey A. Ackerman↗

Comparison of Acoustic Models and Trajectory Generation Methods for an Acoustically-Aware Aircraft

Motivation - Noise management is one of the major barriers to Urban Air Mobility - Approaches to noise mitigation (non-exhaustive) - Vehicle configuration - Directivity control via propeller phase synchronization - Trajectory optimization Objective - Create framework for trajectory generation integrating location-based acoustic metrics and vehicle performance limitations - Multiple trajectory optimization methods and acoustic noise models - Mission-relevant constraints - Mission duration, airspace restrictions, ... - Vehicle dynamic constraints - Aircraft structural limitations, min/max airspeed, ... - Vehicle separation/obstacle avoidance - Acoustic constraints at a number of discrete observer locations

Kasey A Ackerman↗

Master clock and time distribution system for the NASA Deep Space Network

NASA's Deep Space Network (DSN) consists of more than 20 antennas located at three globally spaced ground communications facilities. Local generation and distribution of precise time and frequency reference signals comprise an essential and central component of each complex. Within each complex synchronized timing references are required by approximately 100 users located at distances up to 30 kilometers from the central control center and station Master Clock. In this paper a highly modular, hot-swappable, and expandable system design for generation, delivery, and synchronization of highly precise and stable timing signals over fiber optic cables is described.

Tjoelker, R. L.↗

The Bearingless Electrical Machine

Electromagnetic bearings allow the suspension of solids. For rotary applications, the most important physical effect is the force of a magnetic circuit to a high permeable armature, called the MAXWELL force. Contrary to the commonly used MAXWELL bearings, the bearingless electrical machine will take advantage of the reaction force of a conductor carrying a current in a magnetic field. This kind of force, called Lorentz force, generates the torque in direct current, asynchronous and synchronous machines. The magnetic field, which already exists in electrical machines and helps to build up the torque, can also be used for the suspension of the rotor. Besides the normal winding of the stator, a special winding was added, which generates forces for levitation. So a radial bearing, which is integrated directly in the active part of the machine, and the motor use the laminated core simultaneously. The winding was constructed for the levitating forces in a special way so that commercially available standard ac inverters for drives can be used. Besides wholly magnetic suspended machines, there is a wide range of applications for normal drives with ball bearings. Resonances of the rotor, especially critical speeds, can be damped actively.

Bichsel, J.↗

Acquisition of pseudonoise signals by sequential estimation

Rapid Acquisition by Sequential Estimation /RASE/ system is used in the receivers of tracking and communications systems to bring identical locally generated pseudonoise digital modulation signal into time synchronization with the incoming pseudonoise signal. This acquisition system is particularly suited for medium input signal-to-noise ratios.

Ward, R. B.↗

Two carrier communication system with single transmitter

A pulse code modulated communication system is disclosed for transmitting two subcarrier modulated carriers from a single transmitter comprising two channels for phase modulating the two carriers independently. The modulating subcarriers are independently modulated by data and/or pseudonoise (PN) codes as desired. The modulated carriers are switched alternately to the single transmitter in synchronism with operation of a PN code generator when PN code modulation is present, as for ranging.

Easterling, M. F.↗

Computer/computer interface

System synchronizes data transfer between two computers by generating data strobe pulses when computers are ready for data transfer. In addition, interface filters noise by sampling.

Anderson, T. O.↗

User data dissemination concepts for earth resources: Executive summary

The impact of the future capabilities of earth-resources data sensors (both satellite and airborne) and their requirements on the data dissemination network were investigated and optimum ways of configuring this network were determined. The scope of this study was limited to the continental U.S.A. (including Alaska) and to the 1985-1995 time period. Some of the conclusions and recommendations reached were: (1) Data from satellites in sun-synchronous polar orbits (700-920 km) will generate most of the earth-resources data in the specified time period. (2) Data from aircraft and shuttle sorties cannot be readily integrated in a data-dissemination network unless already preprocessed in a digitized form to a standard geometric coordinate system. (3) Data transmission between readout stations and central preprocessing facilities, and between processing facilities and user facilities are most economically performed by domestic communication satellites. (4) The effect of the following factors should be studied: cloud cover, expanded coverage, pricing strategies, multidiscipline missions.

Davies, R.↗

Synchronized Radar-Target Simulator

Apparatus for testing radar system generates signals that simulate amplitude and phase characteristics of target returns and their variation with antenna-pointing direction. Antenna movement causes equipment to alter test signal in imitation of behavior of real signal received during tracking.

Chin, B. C.↗

Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

Humphreys, William M., Jr.↗

Coverability graphs for a class of synchronously executed unbounded Petri net

After detailing a variant of the concurrent-execution rule for firing of maximal subsets, in which the simultaneous firing of conflicting transitions is prohibited, an algorithm is constructed for generating the coverability graph of a net executed under this synchronous firing rule. The omega insertion criteria in the algorithm are shown to be valid for any net on which the algorithm terminates. It is accordingly shown that the set of nets on which the algorithm terminates includes the 'conflict-free' class.

Stotts, P. David↗