Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “space needle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Application of Computer Tomography for Life Detection

Perhaps one of the most fundamentally difficult challenges facing those who would search for life is that of scale determination. Spatial scales of life on Earth range over more than 15 orders of magnitude in mass and volume, and more than 8 orders of magnitude in 2 dimensional space. If the distribution of life is sparse in comparison to the background on which it is found, then the choice of the right scale is critical to finding that life. But how does one identify the proper scale? To put this in other words, how does one recognize the "haystacks" in which the needles (biosignatures and evidence of life) might be most profitably searched for? The problem is further exacerbated when conditions get extreme because much of the life moves from the clement surface environment into the pores and more clement environments inside of rocks, minerals and soils. Once encased in their lithic homes, these microbes become nearly impossible to study by standard techniques because of the opacity of the rocks. It is this problem that we propose to address in the work proposed here. Computer Tomography (CT) has been a very valuable tool in medicine, where the best resolution available has typically been of the order of about 0.5 mm. However, to adapt the approach for life detection of microbial endoliths, the resolution needs to be moved to the micrometer and even submicrometer levels. Thus for the studies proposed here, we begin with a commercially available instrument that can yield resolution of approximately 10 micrometers. The rational for this is twofold: first, this is the "state of the art" in laboratory instruments; and second, that while the usual size of a microbial cell is about 1 micron, microorganisms tend to live in communities that usually exceed the 10 micrometer size range. The resolution also depends on the sample size itself, so having a small lab instrument into which small samples can be placed will be beneficial to the resolution. We have now used several different CT systems, beginning with the medical scanners (Arcadia CT group) for the detection of layered communities in sandstone rocks from Antarctica. Even this crude instrument was able to point to the areas of the rock that were dominated by microbial populations - this provides the critical first information that says, "Go back and look at these sites with other methods." We showed that without sample preparation or destruction it was possible to gain knowledge as to the presence of density differences suggestive of life.

Tsapin, A.↗

Optimized blind gamma-ray pulsar searches at fixed computing budget

The sensitivity of blind gamma-ray pulsar searches in multiple years worth of photon data, as from the Fermi LAT, is primarily limited by the finite computational resources available. Addressing this 'needle in a haystack' problem, here we present methods for optimizing blind searches to achieve the highest sensitivity at fixed computing cost. For both coherent and semicoherent methods, we consider their statistical properties and study their search sensitivity under computational constraints. The results validate a multistage strategy, where the first stage scans the entire parameter space using an efficient semicoherent method and promising candidates are then refined through a fully coherent analysis. We also find that for the first stage of a blind search incoherent harmonic summing of powers is not worthwhile at fixed computing cost for typical gamma-ray pulsars. Further enhancing sensitivity, we present efficiency-improved interpolation techniques for the semicoherent search stage. Via realistic simulations we demonstrate that overall these optimizations can significantly lower the minimum detectable pulsed fraction by almost 50% at the same computational expense.

79 ASTRONOMY AND ASTROPHYSICS↗

Advances in understanding hydration of Portland cement

Progress in understanding hydration is summarized. Evidence supports the geochemistry dissolution theory as an explanation for the induction period, in preference to the inhibiting layer theory. The growth of C–S–H is the principal factor controlling the main heat evolution peak. Electron microscopy indicates that C–S–H “needles” grow from the surface of grains. At the peak, the surface is covered, but deceleration cannot be attributed to diffusion control. The shoulder peak comes from renewed reaction of C{sub 3}A after depletion of sulfate in solution, but release of sulfate absorbed on C–S–H means that ettringite continues to form. After several days space becomes the major factor controlling hydration. The use of new analytical technique is improving our knowledge of the action of superplasticizers and leading to the design of molecules for different applications. Atomistic modeling is becoming a topic of increasing interest. Recent publications in this area are reviewed.

36 MATERIALS SCIENCE↗

Tracking Electromagnetic Energy With SQUIDs

A superconducting quantum interference device (SQUID) is a gadget used to measure extremely weak signals, specifically magnetic flux. It can detect subtle changes in energy, up to 100 billion times weaker than the electromagnetic energy required to move a compass needle. SQUIDs are used for a variety of testing procedures where extreme sensitivity is required and where the test instrument need not come into direct contact with the test subject. NASA uses SQUIDs for remote, noncontact sensing in a variety of venues, including monitoring the Earth s magnetic field and tracking brain activity of pilots. Scientists at NASA s Goddard Space Flight Center have been making extensive use of this technology, from astrophysical research, to tracking the navigational paths of bees in flight to determine if they are using internal compasses. These very sensitive measurement devices have a wide variety of uses within NASA and even more uses within the commercial realm.

Source record↗

Exploring the Relationship Between Reflectance Red Edge and Chlorophyll Content in Slash Pine

Chlorophyll is a key indicator of the physiological status of a forest canopy. However, its distribution may vary greatly in time and space, so that the estimation of chlorophyll content of canopies or branches by extrapolation from leaf values obtained by destructive sampling is labor intensive and potentially inaccurate. Chlorophy11 content is related positively to the point of maximum slope in vegetation reflectance spectra which occurs at wavelengths between 690-740 nm and is known as the "red edge." The red edge of needles on individual slash pine (Piniis elliottii Engelm.) branches and in whole forest canopies was measured with a spectroradiometer. Branches were measured on the ground against a spectrally flat reflectance target and canopies were measured from observation towers against a spectrally variable understory and forest floor. There was a linear relationship between red edge and chlorophyll content of branches (R(exp 2) = 0.91). Measurements of the red edge and this relationship were used to estimate the chlorophyll content of other branches with an error that was lower than that associated with the colorimetric (laboratory) method. There was no relationship between the red edge and the chlorophyll content of whole canopies. This can be explained by the overriding influence of the understory and forest floor, an influence that was illustrated by spectral mixture modeling. The results suggest that the red edge could be used to estimate the chlorophyll content in branches but it is unlikely to be of value for the estimation of chlorophyll content in canopies unless the canopy cover is high.

Curran, Paul J.↗

Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Distortions and Metal–Semiconductor–Metal Transition in Quasi-One-Dimensional Nanowire Compounds AV 3 Q 3 O δ (A = K, Rb, Cs and Q = Se, Te)

Metal cluster compounds have garnered renewed interest in the search for novel superconductors and topological semimetals owing to structural instabilities of metal-cluster geometries and broken symmetries. Here we synthesized needle-like crystals of the V-cluster-based quasi-one-dimensional (Q1D) materials AV 3 Q 3 O δ (A = K, Rb, Cs, Q= Se, Te) which can also be viewed as being composed of parallel nanowires. We examine how changes in their average and local structure control their electronic properties. All compounds crystallize in the TIFe 3 Te 3 -type structure (P6 3 /m space group) with infinite (V 3 )Q 3 ) - double-walled columnar chains separated by A + cations. Our single-crystal and synchrotron powder diffraction studies indicate oxygen atoms partially occupy the center site of the V 6 octahedral metal cluster cages in KV 3 Te 3 O 0.33 , RbV 3 Te 3 O 0.32 , and CsV 3 Te 3 O 0.35 , whereas KV 3 Se 3 is structurally oxygen-free. Our synchrotron X-ray pair distribution function (PDF) analyses indicate that the oxygen-free V 6 cluster octahedra in KV 3 Se 3 are highly distorted perpendicular to the chain direction even at room temperature, reducing the symmetry of the average structure from hexagonal P6 3 /m to monoclinic P2 1 /m. Our theoretical calculation supports this P2 1 /m distortion and suggests the structure further distorts to P2 1 or P2 1 /c at lower temperatures. In contrast, the oxygen-centered V-cluster in KV 3 Te 3 O 0.33 exhibits a V-3-triangle-trimerization along the chain direction. This feature is discernible from the local PDF and is consistent with lattice dynamical calculations based on density functional theory. Resistivity measurements indicate that KV 3 Se 3 exhibits metallic behavior, whereas a dramatic metal-semiconductor-metal transition emerges in KV 3 Te 3 O 6.33 , RbV 3 Te 3 O 0.32 , and CsV 3 Te 3 O 0.35 because of oxygen disorder and changes in local structure captured from our electronic structure analyses of the Fermi surface. Our investigation of the AV 3 Q 3 O 6 family demonstrates the importance of understanding local changes in structure driven by electronic instabilities, which can guide the search for new quantum materials in other low-dimensional cluster-compound materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comet ejection and dynamics of nonspherical dust particles and meteoroids

This paper generalizes the formalism for calculating the ejection velocity of meteoroids and dust from comets and the forces to which such objects are subject in interplanetary space, including the dust tail of comets. It is found that spheres have the smallest cross section of any geometrical figures of the same valume averaged over random orientations, so for a fixed volume and mass, both the ejection velocity and beta reaches a minimum for bodies of spherical shapes. Flakes in random orientation are ejected near 70 percent of the highest ejection velocity for any orientation. Needles in random orientation escape a comet at nearly 90 percent of their maximum velocities. Randomly oriented cylinders of finite thickness escape at lower velocities that are slightly closer to their maximum velocities. The average beta acting on spin-aligned, perfectly absorbing needles is more than half that acting on a sphere of the same material and radius.

Gustafson, Bo A. S.↗

Hydrodissection of the Retrohepatic Space: A Technique to Physically Separate a Liver Tumour from the Inferior Vena Cava and the Ostia of the Hepatic Veins

Objective: To report a technique of percutaneous retrohepatic hydrodissection, highlighting its potential to physically separate liver tumours from the inferior vena cava (IVC) and the ostia of the hepatic veins (HV). Materials and Methods: Between December 2017 and April 2018, hydrodissection of the retrohepatic IVC was performed in 5 patients (5 females; mean age 64.5 years) undergoing percutaneous ablation of 5 liver metastases (mean size: 3.6 cm) located adjacent to the IVC. Number of hydrodissection needles, volume of hydrodissection, separation of tumour/liver parenchyma from IVC/HV post-hydrodissection; technical success of ablation; and complications were tabulated. Results: Two to three 22G spinal needles were required per case for adequate dissection. Mean volume to obtain sufficient hydrodissection was 410 ml on average. Physical separation of the IVC and tumour/hepatic parenchyma was successful in all cases, by 9 mm on average (range 5–12 mm). It also leaded to physical separation of the ostia of the right and middle HV in all cases. There was no early or delayed complication, notably no venous thrombosis in the post-operative period. All lesions but one were completely ablated after one session at 3-month follow-up. The patient with residual tumour was successfully retreated. Conclusion: Retrohepatic hydrodissection is a feasible technique to separate a tumour from the IVC and/or ostia of the HV. This could potentially limit the heat-sink effect/reduce the risk of thrombosis. Larger follow-up studies are required to assess efficacy on a long-term basis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ISAAC Integrated Structural Assembly of Advanced Composites

The NASA Langley Research Center obtained the Integrated Structural Assembly of Advanced Composites (ISAAC) robotic system in 2014 to add state-of-the-art automated manufacturing of composites to our traditional in-house design, analysis, and experimentation capabilities. ISAAC is used to explore fabrication of parts with novel designs and for research into new composite manufacturing techniques. Automated fiber placement (AFP) was the initial manufacturing capability on ISAAC and has been used to support a range of aeronautics and space projects including the Advanced Composites Project (ACP), Composites for Exploration Upper Stage (CEUS), and Advanced Air Transportation Technologies (AATT). In addition to AFP, ISAAC can now provide through-thickness reinforcement of composites by adding stitches through dry fabric prior to resin infusion. Stitching is of interest since it can improve damage tolerance, reduce final assembly time, and reduce inspection requirements. ISSAC can stitch traditional single-needle seams and perform stitching operations using two needles when access is only available to one side of the part. Stitching capability is being advanced in the High-Rate Composites Aircraft Manufacturing (HiCAM) project today. This lecture will describe the work with ISAAC today and new exciting plans for the future.

automated fiber placement↗

Black-silicon as a Wideband Infrared Absorber for the Space Instruments: Fabrication, Modeling, and Characterization

The uniform black silicon (BSI) cryogenically etched has been demonstrated as a superior absorber in par with other ultra-absorbers such as carbon nano tubes in the visible and near-infrared spectrum. In this work, we discuss the fabrication, modeling, and characterization of the BSI aiming at the 2.5-5 microns range. We investigated a series of cryogenic parameters such as temperature, pressure, oxygen flowrate, power, and etching duration and fabricated a series of uniformly etched wafers. Additionally, we established at hree-dimensional mathematical model of a unit cell and manipulated the silicon needle geometry and shape. Our preliminary fabrication results show silicon needles of 8 micron height have five orders of magnitude specular reflectance in the infrared region. The modeling efforts how longer pillar heights could be better absorbers as the wavelength increases.

Wideband absorber↗

Cone-beam Computed Tomography-guided Stereotactic Liver Punctures: A Phantom Study

Purpose: Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. Methods: Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPE{sub CBCT}) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPE{sub CBCT-CT} from fused datasets. Image coregistration was evaluated using fiducial registration error (FRE{sub CBCT-CT}) and target registration error (TRE{sub CBCT-CT}). Results: Positioning accuracies in lateral directions pertaining to CBCT (TPE{sub CBCT} = 2.1 {+-} 1.0 mm) were found to be better to those achieved from previous study using CT (TPE{sub CT} = 2.3 {+-} 1.3 mm). Image coregistration error was 0.3 {+-} 0.1 mm, resulting in an average TRE of 2.1 {+-} 0.7 mm (N = 5 targets) and average Euclidean TPE{sub CBCT-CT} of 3.1 {+-} 1.3 mm. Conclusions: Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatio-temporal characteristics of Trichel pulse at low pressure

Trichel pulses are investigated using a needle-to-plane electrode geometry at low pressure. The evolution of current and voltage, the spatio-temporal discharge images of Trichel pulse are measured. The rising time and duration time in a pulse are about 10 μs and several tens of microseconds, respectively. One period of pulse can be divided into three stages: the stage preceding cathode breakdown, cathode glow formation, and discharge decaying process. Besides a cathode glow and a dark space, an anode glow is also observed. The emission spectra mainly originate from the C{sup 3}Π{sub u} → B{sup 3}Π{sub g} transition for nitrogen. In addition, the capacitances in parallel connected with the discharge cell have important influence on the pulsing frequency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Breast Biopsy System

Charge Coupled Devices (CCDs) are high technology silicon chips that connect light directly into electronic or digital images, which can be manipulated or enhanced by computers. When Goddard Space Flight Center (GSFC) scientists realized that existing CCD technology could not meet scientific requirements for the Hubble Space Telescope Imagining Spectrograph, GSFC contracted with Scientific Imaging Technologies, Inc. (SITe) to develop an advanced CCD. SITe then applied many of the NASA-driven enhancements to the manufacture of CCDs for digital mammography. The resulting device images breast tissue more clearly and efficiently. The LORAD Stereo Guide Breast Biopsy system incorporates SITe's CCD as part of a digital camera system that is replacing surgical biopsy in many cases. Known as stereotactic needle biopsy, it is performed under local anesthesia with a needle and saves women time, pain, scarring, radiation exposure and money.

Source record↗

Martian Atmospheric Pressure Static Charge Elimination Tool

A Martian pressure static charge elimination tool is currently in development in the Electrostatics and Surface Physics Laboratory (ESPL) at NASA's Kennedy Space Center. In standard Earth atmosphere conditions, static charge can be neutralized from an insulating surface using air ionizers. These air ionizers generate ions through corona breakdown. The Martian atmosphere is 7 Torr of mostly carbon dioxide, which makes it inherently difficult to use similar methods as those used for standard atmosphere static elimination tools. An initial prototype has been developed to show feasibility of static charge elimination at low pressure, using corona discharge. A needle point and thin wire loop are used as the corona generating electrodes. A photo of the test apparatus is shown below. Positive and negative high voltage pulses are sent to the needle point. This creates positive and negative ions that can be used for static charge neutralization. In a preliminary test, a floating metal plate was charged to approximately 600 volts under Martian atmospheric conditions. The static elimination tool was enabled and the voltage on the metal plate dropped rapidly to -100 volts. This test data is displayed below. Optimization is necessary to improve the electrostatic balance of the static elimination tool.

Johansen, Michael R.↗

Emission properties of explosive field emission cathodes

The research results of the explosive field emission cathode plasma expansion velocity and the initial emission area in the planar diode configuration with cathodes made of graphite, stainless steel, polymer velvet, carbon coated, and carbon fiber (needle type) cathodes are presented. The experiments have been performed at the electron accelerator LIA-200 (200 kV, 100 ns, and 4 kA). The diode voltage has been varied from 28-225 kV, whereas the current density has been varied from 86-928 A/cm{sup 2} with 100 ns pulse duration. The experimentally obtained electron beam diode perveance has been compared with the 1 dimensional Child-Langmuir- law. It was found that initially only a part of the cathode take part in the emission process. The plasma expands at 1.7-5.2 cm/{mu}s for 4 mm anode-cathode gap for various cathode materials. It was found that the plasma expansion velocity increases with the decrease in the cathode diameter. At the beginning of the accelerating pulse, the entire cathode area participates in the electron emission process only for the multiple needle type carbon fiber cathode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of medical electronic devices in the APL space department

Several electronic devices for automatically correcting specific defects in a body's physiologic regulation and allowing approximately normal functioning are described. A self-injurious behavior inhibiting system (SIBIS) is fastened to the arm of a person with chronic self-injurious behavior patterns. An electric shock is delivered into the arm whenever the device senses above-threshold acceleration of the head such as occur with head-bangers. Sounding a buzzer tone with the shock eventually allows transference of the aversive stimulus to the buzzer so shocks are no longer necessary. A programmable implantable medication system features a solenoid pump placed beneath the skin and refueled by hypodermic needle. The pump functions are programmable and can deliver insulin, chemotherapy mixes and/or pain killers according to a preset schedule or on patient demand. Finally, an automatic implantible defibrillator has four electrodes attached directly to the heart for sensing electrical impulses or emitting them in response to cardiac fibrillation.

Newman, A. L.↗

Production of Gas Bubbles in Reduced Gravity Environments

In a wide variety of applications such as waste water treatment, biological reactors, gas-liquid reactors, blood oxygenation, purification of liquids, etc., it is necessary to produce small bubbles in liquids. Since gravity plays an essential role in currently available techniques, the adaptation of these applications to space requires the development of new tools. Under normal gravity, bubbles are typically generated by forcing gas through an orifice in a liquid. When a growing bubble becomes large enough, the buoyancy dominates the surface tension force causing it to detach from the orifice. In space, the process is quite different and the bubble may remain attached to the orifice indefinitely. The most practical approach to simulating gravity seems to be imposing an ambient flow to force bubbles out of the orifice. In this paper, we are interested in the effect of an imposed flow in 0 and 1 g. Specifically, we investigate the process of bubble formation subject to a parallel and a cross flow. In the case of parallel flow, we have a hypodermic needle in a tube from which bubbles can be produced. On the other hand, the cross flow condition is established by forcing bubbles through an orifice on a wall in a shear flow. The first series of experiments have been performed under normal gravity conditions and the working fluid was water. A high quality microgravity facility has been used for the second type and silicone oil is used as the host liquid.

Oguz, Hasan N.↗