Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “single mode fibers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

96 records · Page 6

Resonant metasurface‐enabled quantum light sources for single‐photon emission and entangled photon‐pair generation

Light encodes information in multiple degrees of freedom (e.g., frequency, amplitude, and phase), enabling high‐speed, high‐bandwidth communication through fiber optics. Unlike classical light, quantum light (single or entangled photons) can transmit quantum states over long distances without loss of coherence, thereby coherently interconnecting quantum nodes for distributed quantum entanglement. Quantum light sources are critical for developing scalable quantum networks aimed at distributed quantum computing, quantum teleportation, and secure quantum communications. However, existing quantum light sources suffer from limited integrability, insufficient spectral and spatial tunability, and inefficiencies in achieving mass‐produced, deterministic, on‐demand quantum light generation. These limitations significantly hinder progress toward direct, on‐chip integration with quantum processing units and detectors – an essential step toward scalable quantum networks. Resonant metasurfaces that leverage photonic modes – such as Mie resonances, guided‐mode resonances, or symmetry‐protected bound states in the continuum – offer strong spatial and temporal confinement of electromagnetic fields, characterized by high quality factors and small mode volumes. These metasurfaces greatly enhance linear and nonlinear light‐matter interactions, making them ideal for efficient on‐chip quantum light generation and manipulation. Here, we describe recent advances in nanoscale quantum light sources and quantum photonic state manipulation enabled by resonant metasurfaces. We also provide an outlook on next‐generation miniaturized quantum light sources achievable through materials innovations in quantum emitters, the co‐design of resonant metasurfaces, and ultimately, the heterogeneous integration of emerging layered van der Waals materials with resonant metasurfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Super-resolution demodulation for fiber sensor arrays based on the MUSIC algorithm

This paper studies the use of MUltiple SIgnal Classification (MUSIC) as a super-resolution algorithm to improve demodulation results for intrinsic Fabry–Perot interferometer (IFPI) sensor arrays. Through distinction between noise and signal subspaces in an observation matrix, this paper shows that a 38-fold improvement in the full width at half maximum (FWHM) estimation of IFPI optical path differences (OPD) can be achieved using this algorithm. Based on this improved method, this paper demonstrates that a tunable laser with a 1.3-nm tuning range can achieve the same sensor demodulation performance as a tunable laser with a 50-nm tuning range if a conventional Fourier transform-based algorithm is used. This paper presents a new approach to analyzing optical signals produced by multiple multiplexed interferometers with similar OPDs with potential applications for both single-mode and multiple-mode devices.

Li, Yuqi (ORCID:0000000291643663)↗

Delamination imaging in composites using cross-correlation method by non-contact air-coupled Lamb waves

Abstract This paper presents a cross-correlation damage detection technique using damage scattered waves of all directions cross-correlate with the incident waves for delamination imaging in carbon fiber reinforced polymer (CFRP) composite plate. The presented imaging can not only detect the delamination but also precisely quantify the damage with locations and sizes. First, a CFRP composite sample with interlaminar delamination by inserting the Teflon layer is designed and manufactured in house using the hot-press machine. And a three-dimensional model of composite sample is simulated using the finite element method. Next, the cross-correlation imaging algorithm is introduced in detail, and the cross-correlation imaging proof-of-concept study is conducted with the simulated Lamb waves in the composite sample. Finally, a fully non-contact air-coupled transducer and scanning laser Doppler vibrometer system with a single-mode Lamb wave method is established to actuate and sense the interrogating Lamb waves in the structure. The imaging method is experimentally implemented for the one delamination and two delaminations imaging and quantification.

Instruments & Instrumentation↗

Integrated photonic molecule Brillouin laser with a high-power sub-100-mHz fundamental linewidth

Photonic integrated lasers with an ultra-low fundamental linewidth and a high output power are important for precision atomic and quantum applications, high-capacity communications, and fiber sensing, yet wafer-scale solutions have remained elusive. Here we report an integrated stimulated Brillouin laser (SBL), based on a photonic molecule coupled resonator design, that achieves a sub-100-mHz fundamental linewidth with greater than 10-mW output power in the C band, fabricated on a 200-mm silicon nitride (Si 3 N 4 ) CMOS-foundry compatible wafer-scale platform. The photonic molecule design is used to suppress the second-order Stokes (S2) emission, allowing the primary lasing mode to increase with the pump power without phase noise feedback from higher Stokes orders. The nested waveguide resonators have a 184 million intrinsic and 92 million loaded Q, over an order of magnitude improvement over prior photonic molecules, enabling precision resonance splitting of 198 MHz at the S2 frequency. We demonstrate S2-suppressed single-mode SBL with a minimum fundamental linewidth of 71±18 mHz, corresponding to a 23±6-mHz 2 /Hz white-frequency-noise floor, over an order of magnitude lower than prior integrated SBLs, with an ∼11-mW output power and 2.3-mW threshold power. The frequency noise reaches the resonator-intrinsic thermo-refractive noise from 2-kHz to 1-MHz offset. The laser phase noise reaches −155 dBc/Hz at 10-MHz offset. The performance of this chip-scale SBL shows promise not only to improve the reliability and reduce size and cost but also to enable new precision experiments that require the high-speed manipulation, control, and interrogation of atoms and qubits. Realization in the silicon nitride ultra-low loss platform is adaptable to a wide range of wavelengths from the visible to infrared and enables integration with other components for systems-on-chip solutions for a wide range of precision scientific and engineering applications including quantum sensing, gravitometers, atom interferometers, precision metrology, optical atomic clocks, and ultra-low noise microwave generation.

Liu, Kaikai (ORCID:0000000213609646)↗

Acousto-optic modulators for fibre-optic lines

The specific features of efficient matching of acousto-optic devices with single-mode fibres for the cases of isotropic and anisotropic diffraction are considered. The acousto-optic interaction geometry, optimal for modulating an arbitrarily polarised light beam with a possibility of tuning its frequency shift in the range up to ∼10 MHz, is chosen. Acousto-optic modulators/frequency shifters based on paratellurite (TeO{sub 2}), pigtailed with polarisation-maintaining and non-polarisation-maintaining fibres, have been developed for wavelengths of 1064 and 1550 nm, and their main technical parameters are investigated. (paper)

36 MATERIALS SCIENCE↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗