Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shaped beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. Here, we also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

angle metrology↗

Effect of pointing errors and range on performance of dual-pencil-beam scatterometers

Short-range FM scatterometers with single antennas are plagued by interference set up by feedthrough and internal reflections. Dual-antenna systems have much lower internal interference, but there are problems associated with pointing the antennas at the same spot. This note quantifies these problems for Gaussian-shaped beams. The use of antennas with beamwidth ratios of up to 5:1 is shown to improve performance significantly over that obtained with identical beamwidths. For an angle between antenna centers (as viewed from the beam intersection) that is three times the beamwidth of the narrower antenna, the usable spread of range for equal beamwidths is only about 1.85:1, while for an angular ratio of 5, the usable spread of range is greater than 20:1.

Moore, R. K.↗

Central Density and Low-Mode Perturbation Control of Inertial Confinement Fusion Dynamic-Shell Targets

The dynamic-shell target is a new class of design for inertial confinement fusion (ICF). These targets address some of the target fabrication challenges prevalent in current ICF targets and take advantage of advances in manufacturing technologies. This study first examines how the dynamic-shell design can be used to control the density of the central region and therefore convergence ratio, thus expanding the design space for ICF. Additionally, the concern of low-mode perturbation growth is considered. A new class of high-performing beam configurations, based on icosahedral polyhedra and charged-particle simulations is proposed. These configurations achieve low levels of irradiation nonuniformity through selection of beam shapes that suppress the dominant symmetrical mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lateral Beam Shifts and Depolarization Upon Oblique Reflection from Dielectric Mirrors

Abstract Dielectric mirrors comprising thin‐film multilayers are widely used in optical experiments because they can achieve substantially higher reflectance compared to metal mirrors. Here, potential problems are investigated that can arise when dielectric mirrors are used at oblique incidence, in particular for focused beams. It is found that light beams reflected from dielectric mirrors can experience lateral beam shifts, beam‐shape distortion, and depolarization, and these effects have a strong dependence on wavelength, incident angle, and incident polarization. Because vendors of dielectric mirrors typically do not share the particular layer structure of their products, several dielectric‐mirror stacks are designed and simulated, and then the lateral beam shift from two commercial dielectric mirrors and one coated metal mirror is also measured. This paper brings awareness of the tradeoffs between dielectric mirrors and front‐surface metal mirrors in certain optics experiments, and it is suggested that vendors of dielectric mirrors provide information about beam shifts, distortion, and depolarization when their products are used at oblique incidence.

Physics↗

Broadband hard X-ray attosecond pulses from extremely chirped electron beams

Attosecond pulses from free-electron lasers have opened the doors to atomic site-specific studies of bound electronic dynamics on their natural, sub-femtosecond timescales. Key to their success has been electron beam shaping techniques enabling the generation of sub-femtosecond current spikes with peak currents on the order of 10 kA. We demonstrate in an RF linac the generation of current spikes with extreme chirps on the order of 350 MeV/micron, directly competitive with the chirps expected from beam-driven plasma wakefield accelerators. Leveraging chirp-taper compensation, we use these highly chirped beams to generate hard X-ray attosecond pulses with bandwidths exceeding 30 eV, a factor of two beyond previous demonstrations. We simultaneously present the first explicit experimental evidence of chirp-taper compensation in an attosecond XFEL, finding that optimal tapering improves the bandwidth and pulse energy by factors of two and five, respectively, for our conditions. In addition to the immediate utility of such broadband hard X-ray pulses, electron beams with such extreme chirps can be utilized for unique new experimental modalities by performing further compression after the undulators. Such post-lasing compression can enable subsequent superradiant light emission at longer wavelengths, or direct excitation of quantum systems with the beam's intense space-charge field for unique attosecond pump-probe possibilities.

43 PARTICLE ACCELERATORS↗

An imaging system for PLIF/Mie measurements for a combusting flow

The equipment required to establish an imaging system can be divided into four parts: (1) the light source and beam shaping optics; (2) camera and recording; (3) image acquisition and processing; and (4) computer and output systems. A pulsed, Nd:YAG-pummped, frequency-doubled dye laser which can freeze motion in the flowfield is used for an illumination source. A set of lenses is used to form the laser beam into a sheet. The induced fluorescence is collected by an UV-enhanced lens and passes through an UV-enhanced microchannel plate intensifier which is optically coupled to a gated solid state CCD camera. The output of the camera is simultaneously displayed on a monitor and recorded on either a laser videodisc set of a Super VHS VCR. This videodisc set is controlled by a minicomputer via a connection to the RS-232C interface terminals. The imaging system is connected to the host computer by a bus repeater and can be multiplexed between four video input sources. Sample images from a planar shear layer experiment are presented to show the processing capability of the imaging system with the host computer.

Wey, C. C.↗

Benchmarking Monte Carlo codes for the modelling of low-energy neutron production target reactions

The increasing adoption of accelerator-based neutron sources (ABNS) for applications including neutron capture therapy (NCT) research has highlighted the need for accurate simulation tools. Precise modelling of the neutron production target is crucial to ensure that simulated predictions of neutron beam characteristics used for subsequent beam shaping assembly design are reliable. This work presents a comprehensive benchmarking of four widely-used Monte Carlo codes - Geant4, PHITS, FLUKA (CERN), and MCNP - for modelling low-energy neutron production target reactions. Using their recommended physics models and cross-section libraries, we evaluate each code’s performance in simulating four beam-target reactions: 7 Li(p,n) 7 Be, 9 Be(p,n) 9 B, 9 Be(d,n) 10 B, and C(d,n)N. Predictions of neutron yield, angular distributions, and energy spectra are compared against available thick target experimental data. Results show varying levels of agreement between the codes depending on the reaction type, energy range, and beam characteristics. Geant4, MCNP and PHITS are the overall best performing codes for the simulation of total neutron yield and yield in the forward direction across most reactions. Across energies where experimental benchmarks exist, inter-code discrepancies in total and forward-directed yield are typically 10 to 30%, with larger deviations at near-threshold incident ion energies. PHITS provides the best overall reproduction of experimental spectra, particularly for the 9 Be(p,n) 9 B reaction. Additionally, PHITS demonstrates superior computational performance for most reactions. These findings provide valuable guidance for ABNS design, highlighting the strengths and limitations of each code for the simulation of low-energy neutron production reactions.

43 PARTICLE ACCELERATORS↗

Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly

This system was one of the test methods considered for measuring the radius of curvature of one or more of the 18 segmented mirrors that form the 6.5 m diameter primary mirror (PM) of the James Webb Space Telescope (JWST). The assembled telescope will be tested at cryogenic temperatures in a 17-m diameter by 27-m high vacuum chamber at the Johnson Space Center. This system uses a Leica Absolute Distance Meter (ADM), at a wavelength of 780 nm, combined with beam-steering and beam-shaping optics to make a differential distance measurement between a ring mirror on the reflective null assembly and individual PM segments. The ADM is located inside the same Pressure-Tight Enclosure (PTE) that houses the test interferometer. The PTE maintains the ADM and interferometer at ambient temperature and pressure so that they are not directly exposed to the telescope s harsh cryogenic and vacuum environment. This system takes advantage of the existing achromatic objective and reflective null assembly used by the test interferometer to direct four ADM beamlets to four PM segments through an optical path that is coincident with the interferometer beam. A mask, positioned on a linear slide, contains an array of 1.25 mm diameter circular subapertures that map to each of the 18 PM segments as well as six positions around the ring mirror. A down-collimated 4 mm ADM beam simultaneously covers 4 adjacent PM segment beamlets and one ring mirror beamlet. The radius, or spacing, of all 18 segments can be measured with the addition of two orthogonally-oriented scanning pentaprisms used to steer the ADM beam to any one of six different sub-aperture configurations at the plane of the ring mirror. The interferometer beam, at a wavelength of 687 nm, and the ADM beamlets, at a wavelength of 780 nm, pass through the objective and null so that the rays are normally incident on the parabolic PM surface. After reflecting off the PM, both the ADM and interferometer beams return to their respective instruments on nearly the same path. A fifth beamlet, acting as a differential reference, reflects off a ring mirror attached to the objective and null and returns to the ADM. The spacings between the ring mirror, objective, and null are known through manufacturing tolerances as well as through an in situ null wavefront alignment of the interferometer test beam with a reflective hologram located near the caustic of the null. Since total path length between the ring mirror and PM segments is highly deterministic, any ADM-measured departures from the predicted path length can be attributed to either spacing error or radius error in the PM. It is estimated that the path length measurement between the ring mirror and a PM segment is accurate to better than 100 m. The unique features of this invention include the differential distance measuring capability and its integration into an existing cryogenic and vacuum compatible interferometric optical test.

Merle, Cormic↗

Optical Measurement of Mass Flow of a Two-Phase Fluid

An optoelectronic system utilizes wavelength-dependent scattering of light for measuring the density and mass flow of a two-phase fluid in a pipe. The apparatus was invented for original use in measuring the mass flow of a two-phase cryogenic fluid (e.g., liquid hydrogen containing bubbles of hydrogen gas), but underlying principles of operation can readily be adapted to non-cryogenic two-phase fluids. The system (see figure) includes a laser module, which contains two or more laser diodes, each operating at a different wavelength. The laser module also contains beam splitters that combine the beams at the various wavelengths so as to produce two output beams, each containing all of the wavelengths. One of the multiwavelength output beams is sent, via a multimode fiberoptic cable, to a transmitting optical coupler. The other multiwavelength output beam is sent, via another multimode fiber-optic cable, to a reference detector module, wherein fiber-optic splitters split the light into several multiwavelength beams, each going to a photodiode having a spectral response that is known and that differs from the spectral responses of the other photodiodes. The outputs of these photodiodes are digitized and fed to a processor, which executes an algorithm that utilizes the known spectral responses to convert the photodiode outputs to obtain reference laser-power levels for the various wavelengths. The transmitting optical coupler is mounted in (and sealed to) a hole in the pipe and is oriented at a slant with respect to the axis of the pipe. The transmitting optical coupler contains a collimating lens and a cylindrical lens that form the light emerging from the end of the fiber-optic cable into a fan-shaped beam in a meridional plane of the pipe. Receiving optical couplers similar to the transmitting optical couplers are mounted in the same meridional plane at various longitudinal positions on the opposite side of the pipe, approximately facing the transmitting optical coupler along the same slant. Light collected by each receiving optical coupler is sent, via a multimode fiber-optic cable, to a detector module similar to the reference detector module. The outputs of the photodiodes in each detector module are digitized and processed, similarly to those of the reference detector module, to obtain indications of the amounts of light of each wavelength scattered to the corresponding receiving position. The value for each wavelength at each position is also normalized to the reference laser-power level for that wavelength. From these normalized values, the density and the mass flow rate of the fluid are estimated.

Wiley, John↗

Phased Array Antenna for the Mitigation of UAS Interference

The growing demand for Unmanned Aerial Systems (UAS) operating beyond the line of sight (BLOS) has resulted in an increased interest in using existing commercial satellite communication capabilities for UAS command and control (C2) communications. The World Radiocommunication Conference in 2015 designated portions of Ku-Band and Ka-Band fixed satellite service (FSS) spectrum to support UAS C2 communications, provided that potential interference with existing co-allocated users in these bands is addressed. As the user base in this new spectrum allocation expands, there is an increased potential for interference with existing terrestrial communication systems operating under fixed service (FS) allocations. The portion of Ka-Band spectrum allocated for UAS C2 avoids significant interference issues, but the Ku-Band allocation contains a co-primary FS allocation, creating potential interference problems. Therefore, UAS must identify solutions to avoid interfering with these existing FS ground sites while maintaining good links with satellite constellations. UAS operating with conventional fixed feed parabolic antennas will have difficulty in meeting interference thresholds, especially at high latitudes where the antennas will operate with low elevation angles. As a means of addressing this limitation, NASA is investigating the use of a phased array antenna to enable mitigation of interference into ground-based FS receivers. In this paper, a novel lightweight conformal phased array antenna will be presented that can use null-steering and/or beam shaping to avoid ground interference while simultaneously providing strong satellite microwave links for communications. The reduced weight of this design and ability to integrate into the fuselage of smaller UAS platforms will also be discussed as a potential solution to provide BLOS operation via spectrum sharing for an expanding user base. This paper will review design aspects of the conformal phased array antenna, describe the intended benefits in reducing interference with FS ground stations, and describe phased array development and test plans.

Beam Forming↗

Phased Array Antenna for the Mitigation of UAS Interference

The growing demand for Unmanned Aerial Systems (UAS) operating beyond the line of sight (BLOS) has resulted in an increased interest in using existing commercial satellite communication capabilities for UAS command and control (C2) communications. The World Radiocommunication Conference in 2015 designated portions of Ku-Band and Ka-Band fixed satellite service (FSS) spectrum to support UAS C2 communications, provided that potential interference with existing co-allocated users in these bands is addressed. As the user base in this new spectrum allocation expands, there is an increased potential for interference with existing terrestrial communication systems operating under fixed service (FS) allocations. The portion of Ka-Band spectrum allocated for UAS C2 avoids significant interference issues, but the Ku-Band allocation contains a co-primary FS allocation, creating potential interference problems. Therefore, UAS must identify solutions to avoid interfering with these existing FS ground sites while maintaining good links with satellite constellations. UAS operating with conventional fixed feed parabolic antennas will have difficulty in meeting interference thresholds, especially at high latitudes where the antennas will operate with low elevation angles. As a means of addressing this limitation, NASA is investigating the use of a phased array antenna to enable mitigation of interference into ground-based FS receivers. In this paper, a novel lightweight conformal phased array antenna will be presented that can use null-steering and/or beam shaping to avoid ground interference while simultaneously providing strong satellite microwave links for communications. The reduced weight of this design and ability to integrate into the fuselage of smaller UAS platforms will also be discussed as a potential solution to provide BLOS operation via spectrum sharing for an expanding user base. This paper will review design aspects of the conformal phased array antenna, describe the intended benefits in reducing interference with FS ground stations, and describe phased array development and test plans.

Phased Array↗

Design of a compact, cryogen-free superconducting solenoid for the electron lens of the Fermilab Integrable Optics Test Accelerator (IOTA)

The proposed electron lens for Fermilab's Integrable Optics Test Accelerator (IOTA) will broaden its capabilities by enabling new research in nonlinear integrable optics, space-charge compensation, proton beam cooling, and more. The electron lens is based on a 5–10 keV, 1–2 A electron beam, shaped using a 0.7 m long, 0.8 T solenoidal magnetic field. A cryogen-free superconducting solenoid has been designed to provide this solenoidal field, taking into consideration the constraints on space, utilities, and infrastructure in the IOTA experimental hall. The solenoid is made of copper stabilized niobium-titanium conductor, conduction-cooled using 4 K closed-cycle cryocoolers. This paper describes the overall design of the solenoid encompassing its mechanical construction, current leads optimization, cryogenic thermal modeling that provides estimates of cooldown time and static/dynamic heat loads, and quench analysis.

43 PARTICLE ACCELERATORS↗

Enhanced Laser Damage Threshold in Optically Addressable Light Valves via Aluminum Nitride Photoconductors

Abstract Optically addressable light valves (OALVs) are specialized optical components utilized for spatial beam shaping in various laser‐based applications, including optics damage mitigation, and enhanced functionality in diode‐based additive manufacturing requiring high intensities. Current state‐of‐the‐art OALVs employ photoconductors such as Bismuth Silicon Oxide (BSO) or Bismuth Germanium Oxide (BGO), which suffer from limited laser‐induced damage thresholds (LiDT) and inadequate thermal conductivities, thus restricting their use in high peak and average power applications. Aluminum nitride (AlN), an emerging ultra‐wide band gap (UWBG) III–V semiconductor, offers promising optoelectronic properties and superior thermal conductivity (>300 Wm −1 K −1 at 298° K, compared to BSO's 3.29 Wm −1 K −1 ). In this study, the first AlN‐based OALVs are designed, fabricated, and experimentally demonstrated using commercially available single‐crystal AlN substrates. These AlN‐based OALVs have shown clear superiority over BSO and BGO‐based devices. Design considerations for OALVs incorporating UWBG photoconductors are discussed, and the photoresponsivity from defect‐mediated sub‐bandgap absorption in AlN crystals is verified as sufficient for OALVs operating under high light fluences. The optimum driving voltage for the AlN‐based OALV is determined to be ≈ 45 V pp at 100 Hz, achieving a transmittance of 91.3%, an extinction ratio (ER) of more than 100, and a 51:1 image contrast.

36 MATERIALS SCIENCE↗

Magnetized liner inertial fusion platform development to assess performance scaling with drive parameters

Magnetized liner inertial fusion (MagLIF) experiments have demonstrated fusion-relevant ion temperatures up to 3.1 keV and thermonuclear production of up to 1.1 × 1013 deuterium–deuterium neutrons. This performance was enabled through platform development that provided increases in applied magnetic field, coupled preheat energy, and drive current. Advanced coil designs with internal reinforcement enabled an increase from 10 to 20 T. An improved laser pulse shape, beam smoothing, and thinner laser entrance foils increased preheat energy coupling from less than 1 to 2.3 kJ. A redesign of the final transmission line and load region increased peak load current from 16 to 20 MA. The wider range of input parameters was leveraged to study target performance trends with preheat energy, applied magnetic field, and peak load current. Ion temperature and neutron yield generally followed trends in two-dimensional clean Lasnex calculations. Stagnation performance improved with peak load current when other input parameters were also increased such that convergence was maintained. This dataset suggests that reducing convergence to less than 30 would improve predictability of target performance. Lasnex was used to identify a simulation-optimized scaling path, which suggests 10+ kJ of fusion yield is possible on the Z facility with achievable input parameters. This path also indicates >10 MJ could be generated through volume burn on a future facility with a path to high yield (>200 MJ) using cryogenic dense fuel layers. The newly developed MagLIF platform enables exploration of both this simulation optimized scaling path and a recently developed similarity-scaling path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chiral Topological Surface States on a Finite Square Photonic Crystal Bounded by Air

Chiral, topologically protected, photonic surface states can be found at the boundary between gyrotropic photonic crystals where a changing magnetic field induces different topology across the interface. Typically, photonic crystals with either a suitable band structure on both sides of the interface to provide a band gap and evanescent decay of the surface states away from the interface, or an outer layer with engineered material properties is required. In this paper, we show the emergence of topological, unidirectional surface states at the termination of finite gyrotropic photonic crystals with a simple square lattice and C 4 rotational symmetry bounded by a vacuum, eliminating the need for an outside layer to enable chiral surface modes. Here, we start from an infinite, time-reversal-symmetry-breaking photonic crystal with a band gap associated with bands with nonzero Chern numbers, different from all-zero Chern numbers in air. We then modify the photonic crystal to move this band gap below the light line, while maintaining the Chern-number discontinuities. Band-structure calculations for a supercell approximating a photonic crystal finite in the direction normal to the surface demonstrate the existence, dispersion, and chirality of the surface mode. Extensive direct scattering calculations for a point source and spatial Fourier analysis further reveal a unidirectional free-space topological surface state, which propagates counterclockwise around the surface of a finite photonic crystal, providing a nearly foolproof way to cross-check the surface-mode band structure unaffected by backscattering from local defects. Additionally, scattering simulations allow an independent characterization of the state dispersion and unveil the robustness of the topological plasmonic mode propagation around the 90° bends of the structure, being due to only radiation leakage. In contrast to buried topological surface states, the observed surface modes at the photonic crystal–air interface have the advantage of being accessible to the outside world, allowing one to take advantage of the defect-tolerant backscattering-free surface modes to engineer emission from photonic crystal surfaces into arbitrary free-space beam shapes and directions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗