Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shape modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Sequential spectral line analysis for accurate density and temperature diagnosis of laboratory opacity measurements

The accuracy of iron opacity calculated in stellar interiors has been questioned since the discovery of the “solar problem” and the discrepancies between the measured and modeled iron opacity reported in 2015. Experimental opacity benchmarks require accurate temperature and density measurements, which were inferred by analyzing tracer magnesium spectra in those experiments. Could the observed discrepancy be explained by insufficient accuracy in the inferred temperature, density, and their uncertainties? Previous analyses may have yielded biased results due to three limitations: (1) simultaneous multi-line fitting, (2) approximations in line-shape models, and (3) exclusion of certain spectral lines due to insufficient background characterization. Notably, the first issue is a common concern for many inversion methods, including Bayesian inferences. We present a refined analysis method that overcomes these limitations, applied to three categories of iron opacity experiments (Anchor 1, 2, and 3). In particular, the sequential fitting method yields unbiased results with more realistic uncertainties by accounting for line inconsistencies in the parameter uncertainties. The average electron temperature and density values are 162 ± 6 eV and (7.0 ± 1.9) × 10 21 cm −3 for six Anchor 1 experiments, 189 ± 7 eV and (3.4 ± 0.3) × 10 22 cm −3 for 21 Anchor 2 experiments, and 201 ± 6 eV and (4.8 ± 1.1) × 10 22 cm −3 for nine Anchor 3 experiments. These results show ∼4% temperature and ∼20% density reproducibility over a decade, which also aligns with the inferred parameter uncertainties. In conclusion, the resulting temperature and density uncertainties lead to a quasi-continuum iron opacity variation of ±4%–7% for wavelengths below 9.5 Å, which is insufficient to explain the significant model-data discrepancies reported in 2015.

Absorption spectroscopy↗

TH-A-9A-01: Active Optical Flow Model: Predicting Voxel-Level Dose Prediction in Spine SBRT

Purpose: To predict voxel-level dose distribution and enable effective evaluation of cord dose sparing in spine SBRT. Methods: We present an active optical flow model (AOFM) to statistically describe cord dose variations and train a predictive model to represent correlations between AOFM and PTV contours. Thirty clinically accepted spine SBRT plans are evenly divided into training and testing datasets. The development of predictive model consists of 1) collecting a sequence of dose maps including PTV and OAR (spinal cord) as well as a set of associated PTV contours adjacent to OAR from the training dataset, 2) classifying data into five groups based on PTV's locations relative to OAR, two “Top”s, “Left”, “Right”, and “Bottom”, 3) randomly selecting a dose map as the reference in each group and applying rigid registration and optical flow deformation to match all other maps to the reference, 4) building AOFM by importing optical flow vectors and dose values into the principal component analysis (PCA), 5) applying another PCA to features of PTV and OAR contours to generate an active shape model (ASM), and 6) computing a linear regression model of correlations between AOFM and ASM.When predicting dose distribution of a new case in the testing dataset, the PTV is first assigned to a group based on its contour characteristics. Contour features are then transformed into ASM's principal coordinates of the selected group. Finally, voxel-level dose distribution is determined by mapping from the ASM space to the AOFM space using the predictive model. Results: The DVHs predicted by the AOFM-based model and those in clinical plans are comparable in training and testing datasets. At 2% volume the dose difference between predicted and clinical plans is 4.2±4.4% and 3.3±3.5% in the training and testing datasets, respectively. Conclusion: The AOFM is effective in predicting voxel-level dose distribution for spine SBRT. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New insights of asteroid 4179 Toutatis using China Chang'e-2 close flyby optical measurements

The mysteries of near-Earth asteroid 4179 Toutatis have been more comprehensively unveiled by analyzing the optical images taken during the Chang'e-2 flyby in 2012. Compared with previous works, this paper concentrates on the photogrammetric relation between the Chang'e-2 spacecraft and Toutatis and the imaging shadow effect during the flyby. Accurate models of imaging and optical measurements are developed to study Toutatis's dimensions and rotational state at the time of imaging. As the illumination study shows, the shadowed region perpendicular to the long axis accounts for 27.78% of the Toutatis images, while the long axis of the body is fully captured. With a compensation on the shadow effect, the optical measurements reveal that Toutatis's long axis is 4354 ± 56 m, the maximum length is 4391 ± 56 m, and the spatial orientation described with the angles of direction cosine during the flyby is (126.°13 ± 0.°29, 122.°98 ± 0.°21, 126.°63 ± 0.°46). Furthermore, a new triaxial ellipsoid of 4354 × 1835 × 2216 m and a volume of 7.5158 km{sup 3} are proposed based on the previous Toutatis shape model. The effectiveness of the proposed method is validated, since typical features such as the neck and endpoints agree well with the results simultaneously observed by the ground radar. Moreover, it also potentially provides a feasible approach to precisely calculate the spin period of Toutatis.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling of deuterium and carbon radiation transport in MAST-U tokamak advanced divertors

Modest effects of deuterium and carbon radiation opacity in the Super-X and snowflake divertor plasmas are predicted for MAST Upgrade tokamak with core plasma input power 2.5–5 MW and plasma current 1 MA. The radiation transport modeling is based on the SOLPS-EIRENE and UEDGE code divertor plasma predictions. Two radiation transport models are used: one is based on a full radiation transport equation implemented in the radiation transport and collisional-radiative code CRETIN (without feedback on the background plasma), and another is an internal self-consistent UEDGE model with ionization, recombination, and heating rates corrected for Ly α line trapping based on the escape probability model implemented in CRETIN. In MAST-U, the Super-X and snowflake divertor plasmas are predicted to reach detached regimes at lower upstream densities than the standard divertor, and the conclusion still holds with radiation transport effects included. At neutral densities m -3 , modest Ly α deuterium line trapping with optical depths 10–15 is predicted in the Super-X divertor. Divertor plasmas are optically thin to other Lyman and Balmer lines, as well as to strong C III and C IV lines that are responsible for most of divertor radiated power. Insignificant changes (within a few percent) to divertor deuterium ionization and recombination rates are found. Radiation fluxes on outer divertor target are modified within a factor of 2–3 when the radiation transport is accounted for, and a similar variation is found due to the line shape models that define the absorption and emission line profiles in the radiation transport modeling. The predicted Lyman and Balmer spectral intensities are significantly modified due to radiation trapping. A measurement of divertor radiation transport effects is discussed using the Ly β /Ba α line ratio. In the snowflake divertor configuration, divertor plasmas are found to be optically thin to Lyman series lines within a large range of parameter variations that include upstream density, divertor transport coefficients, and magnetic configurations. Finally, modest radiation transport effects are only found in a few cases with strongest divertor transport and magnetic configurations closest to the ideal snowflake configuration, however, the plasma background models that were used are yet to be validated with an experiment.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structural features of Fab fragments of rheumatoid factor IgM-RF in solution

The structural features of the Fab fragments of monoclonal (Waldenstroem's disease) immunoglobulin M (IgM) and rheumatoid immunoglobulin M (IgM-RF) were studied by a complex of methods, including small-angle X-ray scattering (SAXS), electron spin resonance (ESR), and mass spectrometry (MS). The Fab-RF fragment was demonstrated to be much more flexible in the region of interdomain contacts, the molecular weights and the shapes of the Fab and Fab-RF macromolecules in solution being only slightly different. According to the ESR data, the rotational correlation time for a spin label introduced into the peptide sequence for Fab is twice as large as that for Fab-RF (21{+-}2 and 11{+-}1 ns, respectively), whereas the molecular weights of these fragments differ by only 0.5% (mass-spectrometric data), which correlates with the results of molecular-shape modeling by small-angle X-ray scattering. The conclusion about the higher flexibility of the Fab-RF fragment contributes to an understanding of the specificity of interactions between the rheumatoid factor and the antigens of the own organism.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An Integrated Approach to Weather Radar Calibration and Monitoring Using Ground Clutter and Satellite Comparisons

Abstract The stability and accuracy of weather radar reflectivity calibration are imperative for quantitative applications, such as rainfall estimation, severe weather monitoring and nowcasting, and assimilation in numerical weather prediction models. Various radar calibration and monitoring techniques have been developed, but only recently have integrated approaches been proposed, that is, using different calibration techniques in combination. In this paper the following three techniques are used: 1) ground clutter monitoring, 2) comparisons with spaceborne radars, and 3) the self-consistency of polarimetric variables. These techniques are applied to a C-band polarimetric radar (CPOL) located in the Australian tropics since 1998. The ground clutter monitoring technique is applied to each radar volumetric scan and provides a means to reliably detect changes in calibration, relative to a baseline. It is remarkably stable to within a standard deviation of 0.1 dB. To obtain an absolute calibration value, CPOL observations are compared to spaceborne radars on board TRMM and GPM using a volume-matching technique. Using an iterative procedure and stable calibration periods identified by the ground echoes technique, we improve the accuracy of this technique to about 1 dB. Finally, we review the self-consistency technique and constrain its assumptions using results from the hybrid TRMM–GPM and ground echo technique. Small changes in the self-consistency parameterization can lead to 5 dB of variation in the reflectivity calibration. We find that the drop-shape model of Brandes et al. with a standard deviation of the canting angle of 12° best matches our dataset.

54 ENVIRONMENTAL SCIENCES↗

Radiotherapy for stage I seminoma of the testis: Organ equivalent dose to partially in-field structures and second cancer risk estimates on the basis of a mechanistic, bell-shaped, and plateau model

Purpose: The aim of the current study was to (a) calculate the organ equivalent dose (OED) and (b) estimate the associated second cancer risk to partially in-field critical structures from adjuvant radiotherapy for stage I seminoma of the testis on the basis of three different nonlinear risk models. Methods: Three-dimensional plans were created for twelve patients who underwent a treatment planning computed tomography of the abdomen. The plans for irradiation of seminoma consisted of para-aortic anteroposterior and posteroanterior fields giving 20 Gy to the target site with 6 MV photons. The OED of stomach, colon, liver, pancreas, and kidneys, that were partially included in the treatment volume, was calculated using differential dose–volume histograms. The mechanistic, bell-shaped, and plateau models were employed for these calculations provided that organ-specific parameters were available for the subsequent assessment of the excess absolute risk (EAR) for second cancer development. The estimated organ-specific lifetime risks were compared with the respective nominal intrinsic probabilities for cancer induction. Results: The mean OED, which was calculated from the patients’ treatment plans, varied from 0.54 to 6.61 Gy by the partially in-field organ of interest and the model used for dosimetric calculations. The difference between the OED of liver derived from the mechanistic model with those from the bell-shaped and plateau models was less than 1.8%. An even smaller deviation of 1.0% was observed for colon. For the rest organs of interest, the differences between the OED values obtained by the examined models varied from 8.6% to 50.0%. The EAR for stomach, colon, liver, pancreas, and kidney cancer induction at an age of 70 yr because of treatment of a typical 39-yr-old individual was up to 4.24, 11.39, 0.91, 3.04, and 0.14 per 10 000 persons-yr, respectively. Patient’s irradiation was found to elevate the lifetime intrinsic risks by 8.3%–63.0% depending upon the organ of interest and the model employed for risk analysis. Conclusions: Radiotherapy for stage I seminoma of the testis may result in an excess risk for the appearance of secondary malignancies in partially in-field organs. The organ- and model-dependent second cancer risk assessments of this study may be of value for patient counseling and follow-up.

60 APPLIED LIFE SCIENCES↗

Parametric Reconstruction of Glass Fiber-reinforced Polymer Composites from X-ray Projection Data—A Simulation Study

We present a new approach to estimate geometry parameters of glass fibers in glass fiber-reinforced polymers from simulated X-ray micro-computed tomography scans. Traditionally, these parameters are estimated using a multi-step procedure including image reconstruction, pre-processing, segmentation and analysis of features of interest. Each step in this chain introduces errors that propagate through the pipeline and impair the accuracy of the estimated parameters. In the approach presented in this paper, we reconstruct volumes from a low number of projection angles using an iterative reconstruction technique and then estimate position, direction and length of the contained fibers incorporating a priori knowledge about their shape, modeled as a geometric representation, which is then optimized. Using simulation experiments, we show that our method can estimate those representations even in presence of noisy data and only very few projection angles available.

42 ENGINEERING↗

Frequency-comb referenced spectroscopy of v₄₋ and v₅₋excited hot bands in the 1.5 and μm spectrum of C₂H₂

Doppler-free transition frequencies for v₄₋ and v₅₋excited hot bands have been measured in the v₁ + v₃ band region of the spectrum of acetylene using saturation dip spectroscopy with an extended cavity diode laser referenced to a frequency comb. The frequency accuracy of the measured transitions, as judged from line shape model fits and comparison to known frequencies in the v₁ + v₃ band itself, is between 3 and 22 kHz. This is some three orders of magnitude improvement on the accuracy and precision of previous line position estimates that were derived from the analysis of high-resolution Fourier transform infrared absorption spectra. Comparison to transition frequencies computed from constants derived from published Fourier transform infrared spectra shows that some upper rotational energy levels suffer specific perturbations causing energy level shifts of up to several hundred MHz. These perturbations are due to energy levels of the same rotational quantum number derived from nearby vibrational levels that become degenerate at specific energies. Future identification of the perturbing levels will provide accurate relative energies of excited vibrational levels of acetylene in the 7100–7600 cm⁻¹ energy region.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multispectrum analysis of the oxygen A-band

Retrievals of atmospheric composition from near-infrared measurements require measurements of airmass to better than the desired precision of the composition. The oxygen bands are obvious choices to quantify airmass since the mixing ratio of oxygen is fixed over the full range of atmospheric conditions. The OCO-2 mission is currently retrieving carbon dioxide concentration using the oxygen A-band for airmass normalization. The 0.25% accuracy desired for the carbon dioxide concentration has pushed the required state-of-the-art for oxygen spectroscopy. To measure O2 A-band cross-sections with such accuracy through the full range of atmospheric pressure requires a sophisticated line-shape model (Rautian or Speed-Dependent Voigt) with line mixing (LM) and collision induced absorption (CIA). Models of each of these phenomena exist, however, this work presents an integrated self-consistent model developed to ensure the best accuracy. It is also important to consider multiple sources of spectroscopic data for such a study in order to improve the dynamic range of the model and to minimize effects of instrumentation and associated systematic errors. The techniques of Fourier Transform Spectroscopy (FTS) and Cavity Ring-Down Spectroscopy (CRDS) allow complimentary information for such an analysis. We utilize multispectrum fitting software to generate a comprehensive new database with improved accuracy based on these datasets. As a result, the extensive information will be made available as a multi-dimensional cross-section (ABSCO) table and the parameterization will be offered for inclusion in the HITRANonline database.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electric micro fields in simulated two component plasmas

The statistical properties of local electric fields in an classical plasma are investigated by molecular dynamics (MD) simulation. Two-component plasma simulations of neutral hydrogen, protons and electrons for intermediate plasma coupling conditions, typically N{sub e}{approx_equal}10{sup 18}cm{sup -3}, T{sub e}{approx_equal}1eV, have been carried out. These simulations appear as a possible and very useful way to generate relevant microfield sample-sets appropriate for ion emitter lineshape simulations for plasma spectroscopy and to provide guidance for line shape modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automated Classification of Disease Patterns from Echo-cardiography Images Based on Shape Features of the Left Ventricle

Computer assisted diagnosis using analysis of medical images is an area of active research in health informatics. This paper proposes a technique for indication of heart diseases by using information related to shapes of the left ventricle (LV). LV boundaries are tracked from echo-cardiography images taken from LV short axis view, corresponding to two disease conditions viz. dilated cardiomyopathy and hypertrophic cardiomyopathy, and discriminated from the normal condition. The LV shapes are modeled using shape histograms generated by plotting the frequency of normalized radii lengths drawn from the centroid to the periphery, against a specific number of bins. A 3-layer neural network activated by a log-sigmoid function is used to classify the shape histograms into one of the three classes. Experimentations on a dataset of 240 images show recognition accuracies of the order of 80%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linearized spectrum correlation analysis for line emission measurements

A new spectral analysis method, Linearized Spectrum Correlation Analysis (LSCA), for charge exchange and passive ion Doppler spectroscopy is introduced to provide a means of measuring fast spectral line shape changes associated with ion-scale micro-instabilities. This analysis method is designed to resolve the fluctuations in the emission line shape from a stationary ion-scale wave. The method linearizes the fluctuations around a time-averaged line shape (e.g., Gaussian) and subdivides the spectral output channels into two sets to reduce contributions from uncorrelated fluctuations without averaging over the fast time dynamics. In principle, small fluctuations in the parameters used for a line shape model can be measured by evaluating the cross spectrum between different channel groupings to isolate a particular fluctuating quantity. High-frequency ion velocity measurements (100–200 kHz) were made by using this method. We also conducted simulations to compare LSCA with a moment analysis technique under a low photon count condition. Both experimental and synthetic measurements demonstrate the effectiveness of LSCA.

47 OTHER INSTRUMENTATION↗

Radar imaging and characterization of the binary near-earth asteroid (185851) 2000 DP107

The potentially hazardous asteroid (185851) 2000 DP107 was the first binary near-Earth asteroid to be imaged. Radar observations in 2000 provided images at 75 m resolution that revealed the shape, orbit, and spin-up formation mechanism of the binary. The asteroid made a more favorable flyby of the Earth in 2008, yielding images at 30 m resolution. We used these data to obtain shape models for the two components and to improve the estimates of the mutual orbit, component masses, and spin periods. The primary has a sidereal spin period of 2.7745 ± 0.0007 hr and is roughly spheroidal with an equivalent diameter of 863 m ± 5%. It has a mass of 4.656±0.43×10{sup 11} kg and a density of 1381 ± 244 kg m{sup −3}. It exhibits an equatorial ridge similar to the (66391) 1999 KW4 primary; however, the equatorial ridge in this case is not as regular and has a ∼300 m diameter concavity on one side. The secondary has a sidereal spin period of 1.77 ± 0.02 days commensurate with the orbital period. The secondary is slightly elongated and has overall dimensions of 377×314×268 m (6% uncertainties). Its mass is 0.178±0.021×10{sup 11} kg and its density is 1047 ± 230 kg m{sup −3}. The mutual orbit has a semimajor axis of 2.659 ± 0.08 km, an eccentricity of 0.019 ± 0.01, and a period of 1.7556 ± 0.0015 days. The normalized total angular momentum of this system exceeds the amount required for the expected spin-up formation mechanism. An increase of angular momentum from non-gravitational forces after binary formation is a possible explanation. The two components have similar radar reflectivity, suggesting a similar composition consistent with formation by spin-up. The secondary appears to exhibit a larger circular polarization ratio than the primary, suggesting a rougher surface or subsurface at radar wavelength scales.

79 ASTRONOMY AND ASTROPHYSICS↗

CONSTRAINTS ON THE MASS AND RADIUS OF THE NEUTRON STAR XTE J1807-294

The accreting millisecond pulsar XTE J1807-294 is studied through a pulse-shape modeling analysis. The model includes blackbody and Comptonized emission from the one visible hot spot and makes use of the Oblate Schwarzschild approximation for ray-tracing. We include a scattered light contribution, which accounts for flux scattered off an equatorial accretion disk to the observer including time delays in the scattered light. We give limits to mass and radius for XTE J1807-294 and compare these to limits determined for SAX J1808-3658 and XTE J1814-334 previously determined using similar methods. The resulting allowed region for mass-radius curves is small but consistent with a mass-radius relation with nearly constant radius ({approx}12 km) for masses between 1 and 2.5 solar masses.

79 ASTRONOMY AND ASTROPHYSICS↗

ON DETECTING TRANSIENT PHENOMENA

Transient phenomena are interesting and potentially highly revealing of details about the processes under observation and study that could otherwise go unnoticed. It is therefore important to maximize the sensitivity of the method used to identify such events. In this article, we present a general procedure based on the use of the likelihood function for identifying transients which is particularly suited for real-time applications because it requires no grouping or pre-processing of the data. The method makes use of all the information that is available in the data throughout the statistical decision-making process, and is suitable for a wide range of applications. Here we consider those most common in astrophysics, which involve searching for transient sources, events or features in images, time series, energy spectra, and power spectra, and demonstrate the use of the method in the case of a weak X-ray flare in a time series and a short-lived quasi-periodic oscillation in a power spectrum. We derive a fit statistic that is ideal for fitting arbitrarily shaped models to a power density distribution, which is of general interest in all applications involving periodogram analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonglobal correlations in collider physics

Despite their importance for precision QCD calculations, correlations between in- and out-of-jet regions of phase space have never directly been observed. These so-called non-global effects are present generically whenever a collider physics measurement is not explicitly dependent on radiation throughout the entire phase space. In this paper, we introduce a novel procedure based on mutual information, which allows us to isolate these non-global correlations between measurements made in different regions of phase space. We study this procedure both analytically and in Monte Carlo simulations in the context of observables measured on hadronic final states produced in e+e- collisions, though it is more widely applicable.The procedure exploits the sensitivity of soft radiation at large angles to non-global correlations, and we calculate these correlations through next-to-leading logarithmic accuracy. The bulk of these non-global correlations are found to be described in Monte Carlo simulation. They increase by the inclusion of non-perturbative effects, which we show can be incorporated in our calculation through the use of a model shape function. As a result, this procedure illuminates the source of non-global correlations and has connections more broadly to fundamental quantities in quantum field theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗