SU-E-J-258: Inter- and Intra-Fraction Setup Stability and Couch Change Tolerance for Image Guided Radiation Therapy

Purpose: Immobilization devices combine rigid patient fixation as well as comfort and play a key role providing the stability required for accurate radiation delivery. In the setup step, couch re-positioning needed to align the patient is derived via registration of acquired versus reference image. For subsequent fractions, replicating the initial setup should yield identical alignment errors when compared to the reference. This is not always the case and further couch re-positioning can be needed. An important quality assurance measure is to set couch tolerances beyond which additional investigations are needed. The purpose of this work was to study the inter-fraction couch changes needed to re-align the patient and the intra-fraction stability of the alignment as a guide to establish the couch tolerances. Methods: Data from twelve patients treated on the Accuray CyberKnife (CK) system for fractionated intracranial radiotherapy and immobilized with Aquaplast RT, U-frame, F-Head-Support (Qfix, PA, USA) was used. Each fraction involved image acquisitions and registration with the reference to re-align the patient. The absolute couch position corresponding to the approved setup alignment was recorded per fraction. Intra-fraction set-up corrections were recorded throughout the treatment. Results: The average approved setup alignment was 0.03±0.28mm, 0.15±0.22mm, 0.06±0.31mm in the L/R, A/P, S/I directions respectively and 0.00±0.35degrees, 0.03±0.32degrees, 0.08±0.45degrees for roll, pitch and yaw respectively. The inter-fraction reproducibility of the couch position was 6.65mm, 10.55mm, and 4.77mm in the L/R, A/P and S/I directions respectively and 0.82degrees, 0.71degrees for roll and pitch respectively. Intra-fraction monitoring showed small average errors of 0.21±0.21mm, 0.00±0.08mm, 0.23±0.22mm in the L/R, A/P, S/I directions respectively and 0.03±0.12degrees, 0.04±0.25degrees, and 0.13±0.15degrees in the roll, pitch and yaw respectively. Conclusion: The inter-fraction reproducibility should serve as a guide to couch tolerances, specific to a site and immobilization. More patients need to be included to make general conclusions.

60 APPLIED LIFE SCIENCES↗

MO-G-BRE-03: Automated Continuous Monitoring of Patient Setup with Second-Check Independent Image Registration

Purpose: To create a non-supervised quality assurance program to monitor image-based patient setup. The system acts a secondary check by independently computing shifts and rotations and interfaces with Varian's database to verify therapist's work and warn against sub-optimal setups. Methods: Temporary digitally-reconstructed radiographs (DRRs) and OBI radiographic image files created by Varian's treatment console during patient setup are intercepted and used as input in an independent registration module customized for accuracy that determines the optimal rotations and shifts. To deal with the poor quality of OBI images, a histogram equalization of the live images to the DDR counterparts is performed as a pre-processing step. A search for the most sensitive metric was performed by plotting search spaces subject to various translations and convergence analysis was applied to ensure the optimizer finds the global minima. Final system configuration uses the NCC metric with 150 histogram bins and a one plus one optimizer running for 2000 iterations with customized scales for translations and rotations in a multi-stage optimization setup that first corrects and translations and subsequently rotations. Results: The system was installed clinically to monitor and provide almost real-time feedback on patient positioning. On a 2 month-basis uncorrected pitch values were of a mean 0.016° with standard deviation of 1.692°, and couch rotations of − 0.090°± 1.547°. The couch shifts were −0.157°±0.466° cm for the vertical, 0.045°±0.286 laterally and 0.084°± 0.501° longitudinally. Uncorrected pitch angles were the most common source of discrepancies. Large variations in the pitch angles were correlated with patient motion inside the mask. Conclusion: A system for automated quality assurance of therapist's registration was designed and tested in clinical practice. The approach complements the clinical software's automated registration in terms of algorithm configuration and performance and constitutes a practical approach to implement safe and cost-effective radiotherapy.

60 APPLIED LIFE SCIENCES↗

Benchmarking of a treatment planning system for spot scanning proton therapy: Comparison and analysis of robustness to setup errors of photon IMRT and proton SFUD treatment plans of base of skull meningioma

Purpose: Base of skull meningioma can be treated with both intensity modulated radiation therapy (IMRT) and spot scanned proton therapy (PT). One of the main benefits of PT is better sparing of organs at risk, but due to the physical and dosimetric characteristics of protons, spot scanned PT can be more sensitive to the uncertainties encountered in the treatment process compared with photon treatment. Therefore, robustness analysis should be part of a comprehensive comparison between these two treatment methods in order to quantify and understand the sensitivity of the treatment techniques to uncertainties. The aim of this work was to benchmark a spot scanning treatment planning system for planning of base of skull meningioma and to compare the created plans and analyze their robustness to setup errors against the IMRT technique. Methods: Plans were produced for three base of skull meningioma cases: IMRT planned with a commercial TPS [Monaco (Elekta AB, Sweden)]; single field uniform dose (SFUD) spot scanning PT produced with an in-house TPS (PSI-plan); and SFUD spot scanning PT plan created with a commercial TPS [XiO (Elekta AB, Sweden)]. A tool for evaluating robustness to random setup errors was created and, for each plan, both a dosimetric evaluation and a robustness analysis to setup errors were performed. Results: It was possible to create clinically acceptable treatment plans for spot scanning proton therapy of meningioma with a commercially available TPS. However, since each treatment planning system uses different methods, this comparison showed different dosimetric results as well as different sensitivities to setup uncertainties. The results confirmed the necessity of an analysis tool for assessing plan robustness to provide a fair comparison of photon and proton plans. Conclusions: Robustness analysis is a critical part of plan evaluation when comparing IMRT plans with spot scanned proton therapy plans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximizing the probability of satisfying the clinical goals in radiation therapy treatment planning under setup uncertainty

Purpose: This paper introduces a method that maximizes the probability of satisfying the clinical goals in intensity-modulated radiation therapy treatments subject to setup uncertainty. Methods: The authors perform robust optimization in which the clinical goals are constrained to be satisfied whenever the setup error falls within an uncertainty set. The shape of the uncertainty set is included as a variable in the optimization. The goal of the optimization is to modify the shape of the uncertainty set in order to maximize the probability that the setup error will fall within the modified set. Because the constraints enforce the clinical goals to be satisfied under all setup errors within the uncertainty set, this is equivalent to maximizing the probability of satisfying the clinical goals. This type of robust optimization is studied with respect to photon and proton therapy applied to a prostate case and compared to robust optimization using an a priori defined uncertainty set. Results: Slight reductions of the uncertainty sets resulted in plans that satisfied a larger number of clinical goals than optimization with respect to a priori defined uncertainty sets, both within the reduced uncertainty sets and within the a priori, nonreduced, uncertainty sets. For the prostate case, the plans taking reduced uncertainty sets into account satisfied 1.4 (photons) and 1.5 (protons) times as many clinical goals over the scenarios as the method taking a priori uncertainty sets into account. Conclusions: Reducing the uncertainty sets enabled the optimization to find better solutions with respect to the errors within the reduced as well as the nonreduced uncertainty sets and thereby achieve higher probability of satisfying the clinical goals. This shows that asking for a little less in the optimization sometimes leads to better overall plan quality.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-34: Setup Accuracy in Spine SBRT Using CBCT 6D Image Guidance in Comparison with 6D ExacTrac

Purpose Volumetric information of the spine captured on CBCT can potentially improve the accuracy in spine SBRT setup that has been commonly performed through 2D radiographs. This work evaluates the setup accuracy in spine SBRT using 6D CBCT image guidance that recently became available on Varian systems. Methods ExacTrac radiographs have been commonly used for Spine SBRT setup. The setup process involves first positioning patients with lasers followed by localization imaging, registration, and repositioning. Verification images are then taken providing the residual errors (ExacTracRE) before beam on. CBCT verification is also acquired in our institute. The availability of both ExacTrac and CBCT verifications allows a comparison study. 41 verification CBCT of 16 patients were retrospectively registered with the planning CT enabling 6D corrections, giving CBCT residual errors (CBCTRE) which were compared with ExacTracRE. Results The RMS discrepancies between CBCTRE and ExacTracRE are 1.70mm, 1.66mm, 1.56mm in vertical, longitudinal and lateral directions and 0.27°, 0.49°, 0.35° in yaw, roll and pitch respectively. The corresponding mean discrepancies (and standard deviation) are 0.62mm (1.60mm), 0.00mm (1.68mm), −0.80mm (1.36mm) and 0.05° (0.58°), 0.11° (0.48°), −0.16° (0.32°). Of the 41 CBCT, 17 had high-Z surgical implants. No significant difference in ExacTrac-to-CBCT discrepancy was observed between patients with and without the implants. Conclusion Multiple factors can contribute to the discrepancies between CBCT and ExacTrac: 1) the imaging iso-centers of the two systems, while calibrated to coincide, can be different; 2) the ROI used for registration can be different especially if ribs were included in ExacTrac images; 3) small patient motion can occur between the two verification image acquisitions; 4) the algorithms can be different between CBCT (volumetric) and ExacTrac (radiographic) registrations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-659: Quantitative Evaluation of Patient Setup Accuracy of Stereotactic Radiotherapy with the Frameless 6D-ExacTrac System Using Statistical Modeling

Purpose: To evaluate patient setup accuracy and quantify individual and cumulative positioning uncertainties associated with different hardware and software components of the stereotactic radiotherapy (SRS/SRT) with the frameless-6D-ExacTrac system. Methods: A statistical model was used to evaluate positioning uncertainties of the different components of SRS/SRT treatment with the BrainLAB 6D-ExacTrac system using the positioning shifts of 35 patients having cranial lesions (49 total lesions treated in 1, 3, 5 fractions). All these patients were immobilized with rigid head-and-neck masks, simulated with BrainLAB-localizer and planned with iPlan treatment planning system. Infrared imaging (IR) was used initially to setup patients. Then, stereoscopic x-ray images (XC) were acquired and registered to corresponding digitally-reconstructed-radiographs using bony-anatomy matching to calculate 6D-translational and rotational shifts. When the shifts were within tolerance (0.7mm and 1°), treatment was initiated. Otherwise corrections were applied and additional x-rays were acquired (XV) to verify that patient position was within tolerance. Results: The uncertainties from the mask, localizer, IR-frame, x-ray imaging, MV and kV isocentricity were quantified individually. Mask uncertainty (Translational: Lateral, Longitudinal, Vertical; Rotational: Pitch, Roll, Yaw) was the largest and varied with patients in the range (−1.05−1.50mm, −5.06–3.57mm, −5.51−3.49mm; −1.40−2.40°, −1.24−1.74°, and −2.43−1.90°) obtained from mean of XC shifts for each patient. Setup uncertainty in IR positioning (0.88,2.12,1.40mm, and 0.64,0.83,0.96°) was extracted from standard-deviation of XC. Systematic uncertainties of the localizer (−0.03,−0.01,0.03mm, and −0.03,0.00,−0.01°) and frame (0.18,0.25,−1.27mm,−0.32,0.18, and 0.47°) were extracted from means of all XV setups and mean of all XC distributions, respectively. Uncertainties in isocentricity of the MV radiotherapy machine were (0.27,0.24,0.34mm) and kV-imager (0.15,−0.4,0.21mm). Conclusion: A statistical model was developed to evaluate the individual and cumulative systematic and random uncertainties induced by the different hardware and software components of the 6D-ExacTrac-system. The immobilization mask was associated with the largest positioning uncertainty.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-192: A Quick and Effective Method to Validate Patient’s Daily Setup and Geometry Changes Prior to Proton Treatment Delivery Based On Water Equivalent Thickness Projection Imaging (WETPI) for Head Neck Cancer (HNC) Patient

Purpose: With the implementation of Cone-beam Computed-Tomography (CBCT) in proton treatment, we introduces a quick and effective tool to verify the patient’s daily setup and geometry changes based on the Water-Equivalent-Thickness Projection-Image(WETPI) from individual beam angle. Methods: A bilateral head neck cancer(HNC) patient previously treated via VMAT was used in this study. The patient received 35 daily CBCT during the whole treatment and there is no significant weight change. The CT numbers of daily CBCTs were corrected by mapping the CT numbers from simulation CT via Deformable Image Registration(DIR). IMPT plan was generated using 4-field IMPT robust optimization (3.5% range and 3mm setup uncertainties) with beam angle 60, 135, 300, 225 degree. WETPI within CTV through all beam directions were calculated. 3%/3mm gamma index(GI) were used to provide a quantitative comparison between initial sim-CT and mapped daily CBCT. To simulate an extreme case where human error is involved, a couch bar was manually inserted in front of beam angle 225 degree of one CBCT. WETPI was compared in this scenario. Results: The average of GI passing rate of this patient from different beam angles throughout the treatment course is 91.5 ± 8.6. In the cases with low passing rate, it was found that the difference between shoulder and neck angle as well as the head rest often causes major deviation. This indicates that the most challenge in treating HNC is the setup around neck area. In the extreme case where a couch bar is accidently inserted in the beam line, GI passing rate drops to 52 from 95. Conclusion: WETPI and quantitative gamma analysis give clinicians, therapists and physicists a quick feedback of the patient’s setup accuracy or geometry changes. The tool could effectively avoid some human errors. Furthermore, this tool could be used potentially as an initial signal to trigger plan adaptation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-92: Clinical Benefit for Breast and Chest Wall Setup in Using a Breast Board

Purpose: To validate benefit of using a breast board (BB) by analyzing the geometry and dosimetry changes of the regions of interest (ROIs) between CT scans with and without BB. Methods: Seven patients, two chest walls (CW) and five breasts, use BB at CT simulation and no BB at diagnostic CT were included. By using deformable image registration software (Velocity AI), diagnostic CT and planning CT were rigidly co-registered according to the thoracic cage at the target. The heart and the target were then deformedly matched and the contours of the planned ROIs were transferred to the diagnostic CT. Which were brought back to the planning CT data set though the initial rigid co-registration in order to keep the deformed ROIs redefined in the diagnostic CT. Anatomic shifts and volume changes of a ROI beyond the rigid translation were recorded and dosimetry changes to ROIs were compared with recalculated DVHs. Results: Patient setup without the BB had small but systematic heart shifts superiorly by ∼5 mm. Torso rotations in two cases moved the heart in opposite directions by ∼10 mm. The breast target volume, shape, and locations were significantly changed with arm extension over the head but not in cases with the arm extended laterally. Breast setup without BB could increase the mean dose to the heart and the maximal dose to the anterior ventricle wall by 1.1 and 6.7 Gy, respectively. Conclusion: A method for evaluation of breast setup technique is introduced and applied for patients. Results of systematic heart displacement without using the BB and the potential increase of heart doses encourage us to further investigate the current trend of not using a BB for easy setup and CT scans. Using a BB would likely increase patient sag during prolonged IMRT and real-time patient position monitoring is clinically desired.

60 APPLIED LIFE SCIENCES↗

Technical Note: Introduction of variance component analysis to setup error analysis in radiotherapy

Purpose: The purpose of this technical note is to introduce variance component analysis to the estimation of systematic and random components in setup error of radiotherapy. Methods: Balanced data according to the one-factor random effect model were assumed. Results: Analysis-of-variance (ANOVA)-based computation was applied to estimate the values and their confidence intervals (CIs) for systematic and random errors and the population mean of setup errors. The conventional method overestimates systematic error, especially in hypofractionated settings. The CI for systematic error becomes much wider than that for random error. The ANOVA-based estimation can be extended to a multifactor model considering multiple causes of setup errors (e.g., interpatient, interfraction, and intrafraction). Conclusions: Variance component analysis may lead to novel applications to setup error analysis in radiotherapy.

60 APPLIED LIFE SCIENCES↗

Proposal for secondary enclosure setup for experiments to expose plasma facing materials to tritiated plasma in VISIONI

VISIONI is an equipment at SCK-CEN that allows the exposure of candidate plasma facing materials to tritium - deuterium plasmas at ITER first wall conditions. VISIONI itself, being a vacuum setup, acts as primary confinement. To protect operators against exposure to a tritiated atmosphere VISIONI must be placed in a secondary confinement. The current Tritium lab at SCK-CEN has a walk-in process cell which can be used to enclose the plasma chamber and diagnostics of the VISIONI setup, which have a limited tritium inventory. This allows easy accessibility to the setup in a well-ventilated environment. Routine operations should be conducted from outside the process cell and maintenance operations can be conducted from within the process cell with proper protections. The tritium storage and supply can be enclosed in a glove box with a dedicated air detritiation system which is activated during an experiment or in case of an incident. The detritiation system will oxidize tritium and capture it on molecular sieves. By using this confinement approach it is possible to expose materials to a tritiated plasma while maintaining good accessibility of the VISIONI setup. This paper describes the proposed confinement system and compares it to the most common approach where the entire system is enclosed into one large glovebox.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ecloud measurement setup in the Main Injector

Ecloud has been observed in many high intensity accelerators which can limit the amount of current that can be stored in them. In particular, for ProjectX, the amount of beam current that will be stored in the MI (Main Injector) will be {approx}160 x 10{sup 12} protons while the present maximum intensity is {approx}45 x 10{sup 12} protons which is about 3.5x less beam. Although ecloud has been observed in the MI, it has not caused instabilities at the present running conditions. However, there is no guarantee that instabilities caused by ecloud will not be a problem at ProjectX intensities. Therefore, a program has been started to study the ecloud effects with both computer simulations and experiments. In this paper, we will be focusing our attention on how coatings can affect the production of secondary electrons. We have installed an ecloud measurement setup in a straight section of MI which consists of one coated and one uncoated beam pipe with the same physical dimensions and at the same location, together with four retarding field analyzers (RFAs) and three sets of beam position monitors (BPMs) which can be used for the microwave measurements. An ecloud measurement setup was installed in a straight section of the Main Injector in 2009. The goal of the setup was to compare the characteristics of different beam pipe coatings when subjected to proton beam. The setup consists of one coated and one uncoated beam pipe with the same physical dimensions installed at the same location. Four RFAs (retarding field analyzers) and three BPMs (beam position monitors) used for microwave measurements have been used to measure the ecloud densities. The RFAs have performed very well and have collected both the time evolution and energy distribution of the ecloud for bare and two types of beam pipe coatings.

43 PARTICLE ACCELERATORS↗

Comparison of Mesoscale Model Setups for Offshore Wind Resource Assessment: A New Jersey Case Study

As the offshore wind energy industry begins to emerge on the U.S. northeast coast, there is an urgent need for an accurate characterization of the offshore wind resource. The offshore regime features various resource characteristics not seen onshore, including frequent coastal low-level jets, non-steady surface conditions (e.g. waves), complex air-sea and land-sea interactions, and coastal mesoscale circulations (e.g. sea breeze). An accurate characterization of these phenomena in mesoscale models is critical to support accurate energy production estimates and forecasting for future offshore wind farms. However, a robust validation of mesoscale model performance in the offshore U.S. has been limited due to sparse data and difficulty obtaining offshore measurements. Consequently, it is unclear how mesoscale models perform offshore and which suite of parameterizations and input data are best suited for accurate resource characterization. To begin addressing this knowledge gap, the National Renewable Energy Laboratory, in collaboration with the Rutgers Center for Ocean Observing Leadership, conducted a mesoscale model validation campaign in the offshore environment. The Weather Research and Forecasting (WRF) model was assessed and the New Jersey offshore coastal area served as the validation domain. An ensemble of WRF simulations conducted over a one-year period sampled from a range of model setups, including different reanalysis and forecast data inputs, sea surface temperature data inputs, planetary boundary layer parameterizations, and WRF versions. The performance of each ensemble member was validated against a network of observations including offshore floating lidars, coastal met towers, offshore platform measurements, and offshore buoys. Model performance was assessed on annual, seasonal, and diurnal scales with particular emphasis on the vertical wind speed profile and temperature stratification. Preliminary results from this validation work will be presented here. The key WRF inputs and parameters driving changes in the modeled wind resource will be discussed and preliminary recommendations on WRF setups for offshore wind resource modeling will be proposed. The application of this validation exercise to other proposed offshore wind energy areas in the U.S. will also be discussed. mesoscale circulations (e.g. sea breeze). An accurate characterization of these phenomena in mesoscale models is critical to support accurate energy production estimates and forecasting for future offshore wind farms. However, a robust validation of mesoscale model performance in the offshore U.S. has been limited due to sparse data and difficulty obtaining offshore measurements. Consequently, it is unclear how mesoscale models perform offshore and which suite of parameterizations and input data are best suited for accurate resource characterization. To begin addressing this knowledge gap, the National Renewable Energy Laboratory, in collaboration with the Rutgers Center for Ocean Observing Leadership, conducted a mesoscale model validation campaign in the offshore environment. The Weather Research and Forecasting (WRF) model was assessed and the New Jersey offshore coastal area served as the validation domain. An ensemble of WRF simulations conducted over a one-year period sampled from a range of model setups, including different reanalysis and forecast data inputs, sea surface temperature data inputs, planetary boundary layer parameterizations, and WRF versions. The performance of each ensemble member was validated against a network of observations including offshore floating lidars, coastal met towers, offshore platform measurements, and offshore buoys. Model performance was assessed on annual, seasonal, and diurnal scales with particular emphasis on the vertical wind speed profile and temperature stratification. Preliminary results from this validation work will be presented here. The key WRF inputs and parameters driving changes in the modeled wind resource will be discussed and preliminary recommendations on WRF setups for offshore wind resource modeling will be proposed. The application of this validation exercise to other proposed offshore wind energy areas in the U.S. will also be discussed.

17 WIND ENERGY↗

GRAPhEME: a setup to measure (n, xn γ) reaction cross sections

Most of nuclear reactor developments are using evaluated data base for numerical simulations. However, the considered databases present still large uncertainties and disagreements. To improve their level of precision, new measurements are needed, in particular for (n, xn) reactions, which are of great importance as they modify the neutron spectrum, the neutron population, and produce radioactive species. The IPHC group started an experimental program to measure (n, xn gamma) reaction cross sections using prompt gamma spectroscopy and neutron energy determination by time of flight. Measurements of (n, xn gamma) cross section have been performed for {sup 235,238}U, {sup 232}Th, {sup nat,182,183,184,186}W, {sup nat}Zr. The experimental setup is installed at the neutron beam at GELINA (Geel, Belgium). The setup has recently been upgraded with the addition of a highly segmented 36 pixels planar HPGe detector. Significant efforts have been made to reduce radiation background and electromagnetic perturbations. The setup is equipped with a high rate digital acquisition system. The analysis of the segmented detector data requires a specific procedure to account for cross signals between pixels. An overall attention is paid to the precision of the measurement. The setup characteristic and the analysis procedure will be presented along with the acquisition and analysis challenges. Examples of results and their impact on models will be discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of Setup Uncertainty Using Planar and MVCT Imaging for Gynecologic Malignancies

Purpose: This prospective study investigates gynecologic malignancy online treatment setup error corrections using planar kilovoltage/megavoltage (KV/MV) imaging and helical MV computed tomography (MVCT) imaging. Methods and Materials: Twenty patients were divided into two groups. The first group (10 patients) was imaged and treated using a conventional linear accelerator (LINAC) with image-guidance capabilities, whereas the second group (10 patients) was treated using tomotherapy with MVCT capabilities. Patients treated on the LINAC underwent planar KV and portal MV imaging and a two-dimensional image registration algorithm was used to match these images to digitally reconstructed radiographs (DRRs). Patients that were treated using tomotherapy underwent MVCT imaging, and a three-dimensional image registration algorithm was used to match planning CT to MVCT images. Subsequent repositioning shifts were applied before each treatment and recorded for further analysis. To assess intrafraction motion, 5 of the 10 patients treated on the LINAC underwent posttreatment planar imaging and DRR matching. Based on these data, patient position uncertainties along with estimated margins based on well-known recipes were determined. Results: The errors associated with patient positioning ranged from 0.13 cm to 0.38 cm, for patients imaged on LINAC and 0.13 cm to 0.48 cm for patients imaged on tomotherapy. Our institutional clinical target volume-PTV margin value of 0.7 cm lies inside the confidence interval of the margins established using both planar and MVCT imaging. Conclusion: Use of high-quality daily planar imaging, volumetric MVCT imaging, and setup corrections yields excellent setup accuracy and can help reduce margins for the external beam treatment of gynecologic malignancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Changes Resulting From Patient Rotational Setup Errors in Proton Therapy Prostate Plans

Purpose: To evaluate the dose changes to the target and critical structures from rotational setup errors in prostate cancer patients treated with proton therapy. Methods and Materials: A total of 70 plans were analyzed for 10 patients treated with parallel-opposed proton beams to a dose of 7,600 {sup 60}Co-cGy-equivalent (CcGE) in 200 CcGE fractions to the clinical target volume (i.e., prostate and proximal seminal vesicles). Rotational setup errors of +3{sup o}, -3 deg., +5 deg., and -5 deg. (to simulate pelvic tilt) were generated by adjusting the gantry. Horizontal couch shifts of +3 deg. and -3 deg. (to simulate longitudinal setup variability) were also generated. Verification plans were recomputed, keeping the same treatment parameters as the control. Results: All changes shown are for 38 fractions. The mean clinical target volume dose was 7,780 CcGE. The mean change in the clinical target volume dose in the worse case scenario for all shifts was 2 CcGE (absolute range in worst case scenario, 7,729-7,848 CcGE). The mean changes in the critical organ dose in the worst case scenario was 6 CcGE (bladder), 18 CcGE (rectum), 36 CcGE (anterior rectal wall), and 141 CcGE (femoral heads) for all plans. In general, the percentage of change in the worse case scenario for all shifts to the critical structures was <5%. Deviations in the absolute percentage of volume of organ receiving 45 and 70 Gy for the bladder and rectum were <2% for all plans. Conclusion: Patient rotational movements of 3 deg. and 5 deg. and horizontal couch shifts of 3 deg. in prostate proton planning did not confer clinically significant dose changes to the target volumes or critical structures00.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfraction and Intrafraction Setup Variability for Prone Breast Radiation Therapy

Purpose: To report the interfraction and intrafraction setup variation for prone breast radiotherapy and to determine an appropriate clinical tumor volume (CTV) to planning target volume (PTV) margin to account for motion and positional uncertainties. Methods and Materials: Ten consecutive patients were prospectively enrolled in a protocol of accelerated, hypofractionated prone breast irradiation. Portal images were acquired using an electronic portal imaging device in cine mode. Interfraction setup error was determined by comparing the first image from each fraction with the digitally reconstructed radiograph. The intrafraction motion was determined by evaluating every image acquired during each fraction and measuring the maximum displacement of an external fiducial and the breast surface. Mean values and 95% confidence intervals (CI) were calculated. Based on these results, a CTV to PTV expansion was derived using the equation M = 2.5SIGMA{sub tot} + 0.7sigma{sub tot.} Results: The mean interfraction setup variability for the fiducial was 0.08 cm (CI: 0.02-0.14) in the anterior to posterior (AP) direction and -0.04 cm (CI: -0.07-0.00) in the superior to inferior (SI) direction. The mean interfraction variability of the breast surface was -0.14 cm (CI: -0.24 to -0.04) in the AP direction. The mean intrafraction displacements of the fiducial and the breast surface were 0.13 cm (CI: 0.12-0.15) and 0.15 cm (CI: 0.14-0.17), respectively. Using the systematic and random errors for the external fiducial, the calculated CTV to PTV expansion was 1.4 cm. Conclusions: Acceptable interfraction and intrafraction variability were demonstrated. The findings resulted in a CTV to PTV expansion of 1.4 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Analysis of an Image-Guided Versus a Non-Image-Guided Setup Approach in Terms of Delivered Dose to the Parotid Glands in Head-and-Neck Cancer IMRT

Purpose: To assess the impact of interfractional variations of shape and setup uncertainties on the dose to the parotid glands (PGs) in head-and-neck cancer intensity-modulated radiotherapy and image-guided radiotherapy (IGRT). Methods and Materials: Two scenarios were analyzed retrospectively for 10 head-and-neck cancer patients, treated with helical TomoTherapy (TomoTherapy Inc., Madison, WI): the IGRT scenario and the non-IGRT scenario. The initial dose-volume histograms derived from the planning computed tomography (PCT) scan and 120 recalculated dose-volume histograms of the PGs of each scenario and of corresponding fractions were compared. Setup errors, cumulative median doses (CMDs) for 6 fractions, overall volumes of the PGs, and volumes that received less than 1 Gy or more than 1.6 Gy per fraction were analyzed. Results: The mean decrease in the PG volume was 0.13 cm{sup 3}/d. There was a significantly higher CMD than initially predicted (mean increase for 6 fractions, 1.13 Gy for IGRT and 0.96 Gy for non-IGRT). The volume that received less than 1 Gy per fraction decreased (mean difference to PCT, 1.36 cm{sup 3} for IGRT [p = 0.003] and 1.35 cm{sup 3} for non-IGRT [p = 0.003]) and the volume that received more than 1.6 Gy per fraction increased with increasing fraction number (mean difference to PCT, 1.14 cm{sup 3} for IGRT [p = 0.01] and 1.16 cm{sup 3} for non-IGRT [p = 0.006]). There was no statistically significant difference between the two scenarios (CMD, p = 0.095; volume that received <1 Gy per fraction, p = 0.896; and volume that received >1.6 Gy per fraction, p = 0.855). Conclusions: In the analyzed group the actual delivered dose to the PGs does not differ significantly between an IGRT and a non-IGRT approach. However, IGRT in head-and-neck cancer intensity-modulated radiotherapy is strongly recommended to improve patient setup.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Setup Reproducibility of the Spinal Column When Using Intensity-Modulated Radiation Therapy for Craniospinal Irradiation With Patient in Supine Position

Purpose: To evaluate local positioning errors of the lumbar spine during fractionated intensity-modulated radiotherapy of patients treated with craniospinal irradiation and to assess the impact of rotational error correction on these uncertainties for one patient setup correction strategy. Methods and Materials: 8 patients (6 adults, 2 children) treated with helical tomotherapy for craniospinal irradiation were retrospectively chosen for this analysis. Patients were immobilized with a deep-drawn Aquaplast head mask. Additionally to daily megavoltage control computed tomography scans of the skull, once-a-week positioning of the lumbar spine was assessed. Therefore, patient setup was corrected by a target point correction, derived from a registration of the patient's skull. The residual positioning variations of the lumbar spine were evaluated applying a rigid-registration algorithm. The impact of different rotational error corrections was simulated. Results: After target point correction, residual local positioning errors of the lumbar spine varied considerably. Craniocaudal axis rotational error correction did not improve or deteriorate these translational errors, whereas simulation of a rotational error correction of the right-left and anterior-posterior axis increased these errors by a factor of 2 to 3. Conclusion: The patient fixation used allows for deformations between the patient's skull and spine. Therefore, for the setup correction strategy evaluated in this study, generous margins for the lumbar spinal target volume are needed to prevent a local geographic miss. With any applied correction strategy, it needs to be evaluated whether or not a rotational error correction is beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗