Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “service migration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Technology Assessment of High Capacity Data Storage Systems: Can We Avoid a Data Survivability Crisis

The density of digital storage media in our information-intensive society increases by a factor of four every three years, while the rate at which this data can be migrated to viable long-term storage has been increasing by a factor of only four every nine years. Meanwhile, older data stored on increasingly obsolete media, are at considerable risk. When the systems for which the media were designed are no longer serviced by their manufacturers (many of whom are out of business), the data will no longer be accessible. In some cases, older media suffer from a physical breakdown of components - tapes simply lose their magnetic properties after a long time in storage. The scale of the crisis is compatible to that facing the Social Security System. Greater financial and intellectual resources to the development and refinement of new storage media and migration technologies in order to preserve as much data as possible.

Halem, M.↗

Annual report of monitoring at Barnes, Kansas, in 2010.

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at Barnes, Kansas, in 1949-1974. Carbon tetrachloride contamination was initially detected in 1986 in the town's public water supply wells. In 2006-2007, the CCC/USDA conducted a comprehensive targeted investigation at and near its former property in Barnes to characterize this contamination. Those results were reported previously (Argonne 2008a). The results of that investigation indicated that carbon tetrachloride contamination is present in groundwater at low to moderate levels in the vicinity of the former CCC/USDA grain storage facility. Information obtained during the 2006-2007 investigation also indicated that at least one other potential source might have contributed to the groundwater contaminant plume (Argonne 2008a). The former agriculture building owned by the local school district, located immediately east of well PWS3, is also a potential source of the contamination. In November 2007, the CCC/USDA began periodic groundwater monitoring at Barnes. The monitoring is being conducted on behalf of the CCC/USDA by Argonne National Laboratory, under the direction of the Kansas Department of Health and Environment (KDHE). The objective is to monitor the carbon tetrachloride contamination identified in the groundwater at Barnes. Through 2010, sampling was conducted in a network of 28 individual monitoring wells (at 19 distinct locations), 2 public water supply wells, and 1 private well (Figure 1.1). The results of the 2006-2007 targeted investigation and the subsequent monitoring events (Argonne 2008a-d, 2009a,b, 2010) demonstrated the presence of carbon tetrachloride contamination in groundwater at levels exceeding the KDHE Tier 2 risk-based screening level (RBSL) of 5.0 {micro}g/L for this compound. The contaminant plume appears to extend from the former CCC/USDA property northwestward, toward the Barnes public water supply wells. Long-term monitoring of the groundwater levels and the contaminant distribution has confirmed that pumping of the public water supply wells affects the direction of groundwater flow. When these wells are not pumping, the direction of groundwater flow is to the northeast. However, when they are pumping, groundwater flow is directed to the northwest, toward the public wells. A contingency interim measure (Argonne 2009c) has been approved by the KDHE (2009) and will be implemented if the two operating public water supply wells become contaminated at levels above the RBSL of 5.0 {micro}g/L for carbon tetrachloride. This current report presents the results of monitoring conducted in 2010. Sampling of the monitoring well network was conducted in March-April 2010 and September 2010. In addition, the two operating public water supply wells were sampled in June 2010 and December 2010. On the basis of an evaluation of the data collected in 2006-2009 (Argonne 2010), including a trend analysis of the site contamination and its migration, the KDHE (2010) concurred that future monitoring will occur on an annual basis, with twice-yearly sampling of the two public water supply wells in service (conducted in cooperation with the city). The KDHE (2010) also agreed to decrease the number wells to be sampled in the future, as discussed in Section 5.

54 ENVIRONMENTAL SCIENCES↗

Smolt Monitoring at the Head of Lower Granite Reservoir and Lower Granite Dam, 2004 Annual Report.

This project monitored the daily passage of Chinook salmon Oncorhynchus tshawytscha, steelhead trout O. mykiss, and sockeye salmon O. nerka smolts during the 2004 spring out-migration at migrant traps on the Snake River and Salmon River. In 2004 fish management agencies released significant numbers of hatchery Chinook salmon and steelhead trout above Lower Granite Dam that were not marked with a fin clip or coded-wire tag. Generally, these fish were distinguishable from wild fish by the occurrence of fin erosion. Total annual hatchery Chinook salmon catch at the Snake River trap was 1.1 times greater in 2004 than in 2003. The wild Chinook catch was 1.1 times greater than the previous year. Hatchery steelhead trout catch was 1.2 times greater than in 2003. Wild steelhead trout catch was 1.6 times greater than the previous year. The Snake River trap collected 978 age-0 Chinook salmon of unknown rearing. During 2004, the Snake River trap captured 23 hatchery and 18 wild/natural sockeye salmon and 60 coho salmon O. kisutch of unknown rearing. Differences in trap catch between years are due to fluctuations not only in smolt production, but also differences in trap efficiency and duration of trap operation associated with flow. Trap operations began on March 7 and were terminated on June 4. The trap was out of operation for a total of zero days due to mechanical failure or debris. Hatchery Chinook salmon catch at the Salmon River trap was 10.8% less and wild Chinook salmon catch was 19.0% less than in 2003. The hatchery steelhead trout collection in 2004 was 20.0% less and wild steelhead trout collection was 22.3% less than the previous year. Trap operations began on March 7 and were terminated on May 28 due to high flows. There were two days when the trap was taken out of service because wild Chinook catch was very low, hatchery Chinook catch was very high, and the weekly quota of PIT tagged hatchery Chinook had been met. Travel time (d) and migration rate (km/d) through Lower Granite Reservoir for PIT-tagged Chinook salmon and steelhead trout marked at the Snake River trap were affected by discharge. Statistical analysis of 2004 data detected a relation between migration rate and discharge for wild Chinook salmon but was unable to detect a relation for hatchery Chinook. The inability to detect a migration rate discharge relation for hatchery Chinook salmon was caused by age-0 fall Chinook being mixed in with the age 1 Chinook. Age-0 fall Chinook migrate much slower than age-1 Chinook, which would confuse the ability to detect the migration rate discharge relation. When several groups, which consisted of significant numbers of age-0 Chinook salmon, were removed from the analysis a relation was detected. For hatchery and wild Chinook salmon there was a 2.8-fold and a 2.4-fold increase in migration rate, respectively, between 50 and 100 kcfs. For steelhead trout tagged at the Snake River trap, statistical analysis detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge. For hatchery and wild steelhead trout, there was a 2.3-fold and a 2.0-fold increase in migration rate, respectively, between 50 and 100 kcfs. Travel time and migration rate to Lower Granite Dam for fish marked at the Salmon River trap were calculated. Statistical analysis of the 2004 data detected a significant relation between migration rate and Lower Granite Reservoir inflow discharge for hatchery Chinook salmon, wild Chinook salmon and hatchery steelhead trout. Not enough data were available to perform the analysis for wild steelhead trout. Migration rate increased 7.0-fold for hatchery Chinook salmon, 4.7-fold for wild Chinook salmon and 3.8-fold for hatchery steelhead as discharge increased between 50 kcfs and 100 kcfs. Fish tagged with passive integrated transponder (PIT) tags at the Snake River and Salmon River traps were interrogated at four dams with PIT tag detection systems (Lower Granite, Little Goose, Lower Monumental, and McNary dams). Because of the addition of the fourth interrogation site (Lower Monumental) in 1993 and the installation of the Removable Spillway Weir at Lower Granite Dam in 2001, caution must be used in comparing cumulative interrogation data. Cumulative interrogations at the four dams for fish marked at the Snake River trap were 82% for hatchery Chinook, 77% for wild Chinook, 90% for hatchery steelhead, and 90% for wild steelhead. Cumulative interrogations at the four dams for fish marked at the Salmon River trap were 68% for hatchery Chinook, 70% for wild Chinook salmon, 80% for hatchery steelhead trout, and 79% for wild steelhead trout.

13 HYDRO ENERGY↗

How relative defect migration energies drive contrasting temperature-dependent microstructural evolution in irradiated ceramics

Ceramic materials have become widely used in various fields of material science, and ceramic oxides such as cubic zirconia (c- ZrO 2 ) and magnesia (MgO) are candidate materials for nuclear energy applications. For the corresponding in-service conditions of these materials, there is a crucial need in studies at moderate or high temperatures of the physical phenomena underlying the damage buildup under irradiation. Here in the present work, we show, using x-ray diffraction, that these two materials exhibit a similar damage accumulation process under ion irradiation at fixed temperature. However, they display an unexpected opposite damaging rate to changes in the irradiation temperature. In fact, as the temperature is increased, the final damage state is reached earlier in c- ZrO 2 while it is delayed in MgO. Rate equation cluster dynamics simulations show that defect clustering is favored over defect recombination in c- ZrO 2 , but the situation is reversed for MgO, explaining the observed opposite response to temperature of the two materials. This contrasting behavior can be rationalized in terms of nonequivalent interstitial versus vacancy defect migration energies in MgO. We finally demonstrate that these results allow for a qualitative prediction of the evolution of the experimental irradiation-induced disorder with temperature, henceforth potentially reducing the cost in selecting and developing ad hoc materials.

36 MATERIALS SCIENCE↗

Lifting and Dropping VMs to Dynamically Transition Between Time- and Space-sharing for Large-Scale HPC Systems

As HPC environments increasingly integrate with edge based systems, system architectures will need to handle a broader class of workloads and scheduling requirements. One result of this shift will be the need to simultaneously support bulk-synchronous parallel (BSP) and on-demand service based applications on the same infrastructure. This in turn will require that future resource management approaches utilize both space-shared as well as time-shared resource scheduling strategies. In this work we introduce the concept of "VM-lifting'' (and its inverse "VM-Dropping'') which allows dynamically switching an HPC workload between space-shared and time-shared scheduling regimes. Our work targets co-kernel based HPC system software environments, in which multiple specialized OS kernels execute natively on dedicated physical resource partitions inside a single compute node. With VM-lifting, a native co-kernel can be migrated at runtime to and from locally hosted Virtual Machine Environments due to changing scheduling requirements of the node. This allows an HPC node to be dynamically (re-)configured as either a time-shared Infrastructure-as-a-Service (IaaS) resource or a dedicated space shared resource based on the current workload demands. We have implemented this approach in the context of the Hobbes Exascale System Software stack and have demonstrated that a node can be reconfigured with minimal impact on the running applications.

Gordon, Nick↗

Volume serving and media management in a networked, distributed client/server environment

The E-Systems Modular Automated Storage System (EMASS) is a family of hierarchical mass storage systems providing complete storage/'file space' management. The EMASS volume server provides the flexibility to work with different clients (file servers), different platforms, and different archives with a 'mix and match' capability. The EMASS design considers all file management programs as clients of the volume server system. System storage capacities are tailored to customer needs ranging from small data centers to large central libraries serving multiple users simultaneously. All EMASS hardware is commercial off the shelf (COTS), selected to provide the performance and reliability needed in current and future mass storage solutions. All interfaces use standard commercial protocols and networks suitable to service multiple hosts. EMASS is designed to efficiently store and retrieve in excess of 10,000 terabytes of data. Current clients include CRAY's YMP Model E based Data Migration Facility (DMF), IBM's RS/6000 based Unitree, and CONVEX based EMASS File Server software. The VolSer software provides the capability to accept client or graphical user interface (GUI) commands from the operator's console and translate them to the commands needed to control any configured archive. The VolSer system offers advanced features to enhance media handling and particularly media mounting such as: automated media migration, preferred media placement, drive load leveling, registered MediaClass groupings, and drive pooling.

Herring, Ralph H.↗

The application of total quality management principles to spacecraft mission operations

By now, the philosophies of Total Quality Management have had an impact on every aspect of American industrial life. The trail-blazing work of Deming, Juran, and Crosby, first implemented in Japan, has 're-migrated' across the Pacific and now plays a growing role in America's management culture. While initially considered suited only for a manufacturing environment, TQM has moved rapidly into the 'service' areas of offices, sales forces, and even fast-food restaurants. The next logical step has also been taken - TQM has found its way into virtually all departments of the Federal Government, including NASA. Because of this widespread success, it seems fair to ask whether this new discipline is directly applicable to the profession of spacecraft operations. The results of quality emphasis on OAO Corporation's contract at JPL provide strong support for Total Quality Management as a useful tool in spacecraft operations.

Sweetin, Maury↗

National population mapping from sparse survey data: A hierarchical Bayesian modeling framework to account for uncertainty

Population estimates are critical for government services, development projects, and public health campaigns. Such data are typically obtained through a national population and housing census. However, population estimates can quickly become inaccurate in localized areas, particularly where migration or displacement has occurred. Some conflict-affected and resource-poor countries have not conducted a census in over 10 y. We developed a hierarchical Bayesian model to estimate population numbers in small areas based on enumeration data from sample areas and nationwide information about administrative boundaries, building locations, settlement types, and other factors related to population density. We demonstrated this model by estimating population sizes in every 10- m grid cell in Nigeria with national coverage. These gridded population estimates and areal population totals derived from them are accompanied by estimates of uncertainty based on Bayesian posterior probabilities. The model had an overall error rate of 67 people per hectare (mean of absolute residuals) or 43% (using scaled residuals) for predictions in out-of-sample survey areas (approximately 3 ha each), with increased precision expected for aggregated population totals in larger areas. This statistical approach represents a significant step toward estimating populations at high resolution with national coverage in the absence of a complete and recent census, while also providing reliable estimates of uncertainty to support informed decision making.

99 GENERAL AND MISCELLANEOUS↗

Ecology of Juvenile Salmon in Shallow Tidal Freshwater Habitats in the Vicinity of the Sandy River Delta, Lower Columbia River, 2008 Annual Report.

The tidal freshwater monitoring (TFM) project reported herein is part of the research, monitoring, and evaluation effort developed by the Action Agencies (Bonneville Power Administration, the U.S. Army Corps of Engineers [USACE], and the U.S. Bureau of Reclamation) in response to obligations arising from the Endangered Species Act (ESA) as a result of operation of the Federal Columbia River Power System. The project is being performed under the auspices of the Northwest Power and Conservation Council's Columbia Basin Fish and Wildlife Program (Project No. 2005-001-00). The research is a collaborative effort among the Pacific Northwest National Laboratory, the Oregon Department of Fish and Wildlife, the National Marine Fisheries Service, and the University of Washington. The overarching goal of the TFM project is to bridge the gap in knowledge between tidal freshwater habitats and the early life history attributes of migrating salmon. The research questions include: In what types of habitats within the tidal freshwater area of the Columbia River are juvenile salmon found, when are they present, and under what environmental conditions? What is the ecological contribution of shallow (0-5 m) tidal freshwater habitats to the recovery of ESA-listed salmon in the Columbia River basin? Field data collection for the TFM project commenced in June 2007 and since then has continued monthly at six to nine sites in the vicinity of the Sandy River delta (river kilometer 192-208). While this report includes summary data spanning the 19-month period of study from June 2007 through December 2008, it highlights sampling conducted during calendar year 2008. Detailed data for calendar year 2007 were reported previously. The 2008 research objectives were as follows: (1) Characterize the vegetation composition and percent cover, conventional water quality, water surface elevation, substrate composition, bathymetry, and beach slope at the study sites within the vicinity of the Sandy River delta. (2) Characterize the fish community and juvenile salmon migration, including species composition, length-frequency distribution, density (number/m{sup 2}), and temporal and spatial distributions in the vicinity of the Sandy River delta in the lower Columbia River and estuary (LCRE). (3) Determine the stock of origin for juvenile Chinook salmon (Oncorhynchus tshawytscha) captured at sampling sites through genetic identification. (4) Characterize the diets of juvenile Chinook and coho (O. kisutch) salmon captured within the study area. (5) Estimate run timing, residence times, and migration pathways for acoustic-tagged fish in the study area. (6) Conduct a baseline evaluation of the potential restoration to reconnect the old Sandy River channel with the delta. (7) Apply fish density data to initiate a design for a juvenile salmon monitoring program for beach habitats within the tidal freshwater segment of the LCRE (river kilometer 56-234).

13 HYDRO ENERGY↗

Web Coverage Service Challenges for NASA's Earth Science Data

In an effort to ensure that data in NASA's Earth Observing System Data and Information System (EOSDIS) is available to a wide variety of users through the tools of their choice, NASA continues to focus on exposing data and services using standards based protocols. Specifically, this work has focused recently on the Web Coverage Service (WCS). Experience has been gained in data delivery via GetCoverage requests, starting out with WCS v1.1.1. The pros and cons of both the version itself and different implementation approaches will be shared during this session. Additionally, due to limitations with WCS v1.1.1 ability to work with NASA's Earth science data, this session will also discuss the benefit of migrating to WCS 2.0.1 with EO-x to enrich this capability to meet a wide range of anticipated user's needs This will enable subsetting and various types of data transformations to be performed on a variety of EOS data sets.

Web Coverage Services↗

Phase I Investigation at Bladen, Nebraska (Final Work Plan)

The village of Bladen is a town of population approximately 237 in the northwest part of Webster County, Nebraska, 30 mi southwest of Hastings and 140 mi southwest of Lincoln, Nebraska. In 2000, the fumigant-related compound carbon tetrachloride was detected in public water supply well PWS 68-1, at a trace level. Low-level contamination, below the maximum contamination level (MCL) of 5.0 μg/L, has been detected intermittently in well PWS 68-1 since 2000, including in the last sample taken in July 2013. In 2006, the village installed a new well, PWS 2006-1, that remains free of contamination. Because the carbon tetrachloride found in well PWS 68-1 might be linked to historical use of fumigants containing carbon tetrachloride at grain storage facilities, including its former facility in Bladen, the CCC/USDA is proposing an investigation to (1) delineate the source and extent of the carbon tetrachloride contamination potentially associated with its former facility, (2) characterize pathways and controlling factors for contaminant migration in the subsurface, and (3) establish a basis for estimating potential health and environmental risks. The work will be performed in accordance with the Intergovernmental Agreement established between the NDEQ and the Farm Service Agency of the USDA. The site investigation at Bladen will be implemented in phases, so that data collected and interpretations developed during each phase can be evaluated to determine if a subsequent phase of investigation is warranted and, if warranted, to provide effective guidance for the subsequent investigation activities. This Work Plan identifies the specific technical objectives and defines the scope of work proposed for the Phase I investigation by compiling and evaluating historical data. The proposed investigation activities will be performed on behalf of the CCC/USDA by the Environmental Science Division of Argonne National Laboratory. Argonne is a nonprofit, multidisciplinary research institute operated by UChicago Argonne, LLC, for the U.S. Department of Energy.

54 ENVIRONMENTAL SCIENCES↗

The 737 graphite composite flight spoiler flight service evaluation

The flight service experience of 111 graphite-epoxy spoilers on 737 transport aircraft and related ground based enviromental exposure of graphite-epoxy material specimens is reported. Spoilers were installed on 28 aircraft representing seven major airlines operating throughout the world. Over 1,188,367 spoiler flight hours and 1,786,837 spoiler landings were accumulated by this fleet. Tests of removed spoilers and ground-based exposure specimens after the fifth year of service indicate modest changes in composite strength properties. Two incidents of trailing edge delamination with subsequent core corrosion were observed. Based on visual, ultrasonic, and destructive testing, there has been no evidence of moisture migration into the honeycomb core and no core corrosion.

Hoffman, D. J.↗

SSC OCIO, IT SUMMIT 2011

The Stennis Space Center (SSC) Records Retention Facility is a centralized location for all SSC records, Records Management staff, and the SSC History Office. The building is a storm resistant facility and provides a secure environment for records housing. The Records Retention Facility was constructed in accordance with The National Archives and Records Administration (NARA) requirements for records storage, making it the first NARA compliant facility in the agency. Stennis Space Center's Records Retention Facility became operational in May 2010. The SSC Records Retention Facility ensures that the required federal records are preserved, managed and accessible to all interested personnel. The facility provides 20,000 cubic feet of records storage capacity for the purpose of managing the centers consolidated records within a central, protected environment. Records housed in the facility are in the form of paper, optical, film and magnetic media. Located within the SSC Records Retention Facility, the Records Management Office provides comprehensive records management services in the form of: a) Storage and life-cycle management of inactive records of all media types; b) Digitizing/scanning of records and documents; c) Non-textual/digital electronic records media storage, migration and transfer; d) Records Remediation.

Cottrell, Dinna L.↗

The Earth Observing System (EOS) Ground System: Leveraging an Existing Operational Ground System Infrastructure to Support New Missions

The Earth Observer System (EOS) was officially established in 1990 and went operational in December 1999 with the launch of its flagship spacecraft Terra. Aqua followed in 2002 and Aura in 2004. All three spacecraft are still operational and producing valuable scientific data. While all are beyond their original design lifetime, they are expected to remain viable well into the 2020s. The EOS Ground System is a multi-mission system based at NASA Goddard Space Flight Center that supports science and spacecraft operations for these three missions. Over its operational lifetime to date, the EOS Ground System has evolved as needed to accommodate mission requirements. With an eye towards the future, several updates are currently being deployed. Subsystem interconnects are being upgraded to reduce data latency and improve system performance. End-of-life hardware and operating systems are being replaced to mitigate security concerns and eliminate vendor support gaps. Subsystem hardware is being consolidated through the migration to Virtual Machine based platforms. While mission operations autonomy was not a design goal of the original system concept, there is an active effort to apply state-of-the-art products from the Goddard Mission Services Evolution Center (GMSEC) to facilitate automation where possible within the existing heritage architecture. This presentation will provide background information on the EOS ground system architecture and evolution, discuss latest improvements, and conclude with the results of a recent effort that investigated how the current system could accommodate a proposed new earth science mission.

Earth Science Mission Operations (ESMO)↗

Hypervelocity Impact Study for Migration from Kevlar® KM2® 705 to KM2® Plus 775: Material Property Measurement and Evaluation as a Ballistic Enhancement in Whipple Shields

Dupont™, the manufacturer of Kevlar®, has begun migrating from KM2® to KM2® Plus for ballistic textiles. Kevlar® KM2® has become an essential element of numerous meteoroid and orbital debris (MMOD) shield systems primarily as a multi-layer insulation (MLI) enhancement, and as such, the migration has implications for numerous system level risk assessments for future vehicles that will need to use the newer KM2® Plus fiber system. While the chemical makeup of the two fabrics are identical, differences in processing have yielded higher tenacities and toughness for the KM2® Plus system. To address this migration, the Hypervelocity Impact Technology (HVIT) group in NASA Exploration Sciences at Johnson Space Center (JSC) has worked with the NASA Engineering and Safety Center (NESC), the Multi-Purpose Crew Vehicle (MPCV) and the MPCV European Service Module (MPCV-ESM) group of the European Space Agency (ESA) with its contractors Airbus and Thales Alenia Space-Italy (TAS-I) to study how KM2® Plus in the woven form of 850 denier 775 compares with KM2® in the woven form of 850 denier 705. The two forms of Kevlar® fabrics have been compared by direct-impact with a known mass and as the rear wall in Whipple shields using the two-stage, light-gas-gun at the Remote Hypervelocity Test Laboratory (RHTL) of NASA JSC White Sands Test Facility (WSTF). From these examinations, it has been found that KM2® Plus does in fact improve the ballistic performance as a ballistic enhancement of MLI with an estimated improvement of 9.5±6.1% between the two fabrics, and on a mass basis, the estimated mass of KM2® Plus 775 is 3.6±0.7% lighter than KM2 705, which means the mass performance improvement is even higher.

Joshua E Miller↗

A Note on Interfacing Object Warehouses and Mass Storage Systems for Data Mining Applications

Data mining is the automatic discovery of patterns, associations, and anomalies in data sets. Data mining requires numerically and statistically intensive queries. Our assumption is that data mining requires a specialized data management infrastructure to support the aforementioned intensive queries, but because of the sizes of data involved, this infrastructure is layered over a hierarchical storage system. In this paper, we discuss the architecture of a system which is layered for modularity, but exploits specialized lightweight services to maintain efficiency. Rather than use a full functioned database for example, we use light weight object services specialized for data mining. We propose using information repositories between layers so that components on either side of the layer can access information in the repositories to assist in making decisions about data layout, the caching and migration of data, the scheduling of queries, and related matters.

Grossman, Robert L.↗

Post-Closure Environmental Sampling and Inspection at the Amchitka Island, Alaska, Site - 17251

In the 1960's and early 1970's, three underground nuclear tests were conducted on Amchitka Island, Alaska. In 1965, the US Department of Defense-in conjunction with the US Atomic Energy Commission (AEC)-conducted the first of these nuclear tests, Long Shot, to provide data that would improve US capabilities for detecting underground nuclear explosions. In 1969, AEC conducted the second test, Milrow, to explore the feasibility of detonating a much larger device. In 1971, AEC conducted the third test, Cannikin, which was the largest underground test ever conducted by the US. The Long-Term Surveillance Plan (LTSP) for the Amchitka, Alaska, Site details how the US Department of Energy Office of Legacy Management (LM) intends to fulfill its mission to protect human health and the environment at and around the Amchitka Island site. The LTSP calls for monitoring to be performed every 5 years, at least during the initial phase of the project. The purpose of the monitoring is to develop a baseline of activity concentrations for selected radionuclides in biota, water, and soil, both on Amchitka Island and at the reference location on Adak Island, approximately 322 kilometers (200 miles) northeast of Amchitka. In addition to the environmental monitoring activities, seven mud pit caps that contain diesel-contaminated soils are inspected. The plan for biological and water sampling (both seawater and freshwater) during the May 2016 sampling event was developed through close coordination with the primary stakeholders, including the Alaska Department of Environmental Conservation, the Aleutian Pribilof Islands Association, and the US Fish and Wildlife Service. The environmental sampling in 2016 is a continuation of LM's evaluation of Amchitka Island's environment. Previous results from similar monitoring programs in 2004 and 2011 indicate that the environment is not being impacted by radionuclide migration and uptake from the underground nuclear testing conducted beneath Amchitka Island; consequently, subsistence and commercial-catch seafood is safe for human consumption. The collection of biota samples (rockfish, Irish lords, greenling, and rockweed) for cesium-134 ({sup 134}Cs), cesium-137 ({sup 137}Cs), plutonium-239 ({sup 239}Pu), plutonium-240 ({sup 240}Pu), and freshwater and seawater samples for {sup 134}Cs, {sup 137}Cs, and tritium ({sup 3}H) was the primary objective of the 2016 sampling effort. Rockfish, Irish lords, and greenling are resident, nonmigratory fish species that spend their entire life cycle in the marine environment, and rockweed is an inter-tidal species that may concentrate cesium. The seawater samples were collected primarily to determine if leakage from the Long Shot detonation could be detected and, secondarily, to compare with the background seawater samples collected from Adak Island. Cesium isotopes are also being analyzed to better understand the potential impact that the Fukushima-Daiichi release might have on the Amchitka and Adak environments. The target detection limits used for the 2016 sampling are lower than those used in previous studies. The lower detection limits make it possible for LM to delineate background activity levels for the radionuclides of interest. Data from the 2016 sampling event go beyond assessing food safety and focus on detecting leakage from the underground nuclear explosions. Additionally, the baseline activity concentrations obtained for the reference area (Adak Island) will enable identification of quantitative statistical trends in the results of future sampling programs. Sampling programs conducted in 2021 and beyond will have an objective to assess the statistical trends of radioactivity levels in the Amchitka Island environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Use of Hygrothermal Models for Understanding Water Transport in Corrosion Under Insulation Applications

Thermal insulation is used in operating facilities to conserve heat and protect against freezing amongst others. A consequence of insulating the equipment is the necessity to manage the introduced threat of corrosion under insulation (CUI). For CUI to occur, water and oxygen must enter and migrate through the insulation to reach the external surface of the equipment. The water transport characteristics are dependent on several factors such as type of insulation, type of jacketing, equipment operating temperature, external weather, water entry/leakage rate and cyclic service. In hot piping, there are competing water transport characteristics, as in water vapor moves outwards away from the equipment as water enters insulation. Knowing the water transport and the parameters that influence the time of wetness at the metal surface helps in understanding conditions favoring CUI.The use of transient hygrothermal models for moisture control is well established in the building insulation design codes and standards. The building designs naturally shed the liquid water to minimize entry and facilitate vapor management so that moisture doesn’t accumulate within building. Several building industry hygrothermal models have been developed and are available for commercial use. One such commercial model has been used to understand water transport in a CUI application. The case study involves evaluation of piping and equipment installed with a closed cell polyurethane insulation. The hygrothermal model provided insights on the parameters influencing the time of wetness and the ease of water escaping the equipment-insulation-jacketing system.

Venkateswaran, Sai P.↗