Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “serial sectioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Axial flow positive displacement worm gas generator

An axial flow positive displacement engine has an inlet axially spaced apart and upstream from an outlet. Inner and outer bodies have offset inner and outer axes extend from the inlet to the outlet through first, second, and third sections of a core assembly in serial downstream flow relationship. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes respectively. The inner and outer helical blades extend radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. The first twist slopes are less than the second twist slopes and the third twist slopes are less than the second twist slopes. A combustor section extends axially downstream through at least a portion of the second section.

Murrow, Kurt David↗

Status of the Characterization of DEs from the Full Circumference Examination of the Inner Container Closure Weld Region (FY2020)

One of the main focus areas of the 3013 Surveillance Program is a thorough evaluation of the inner container closure weld region (ICCWR) opened for destructive examination (DE). As part of the protocol to investigate the corrosion in the ICCWR a laser confocal microscope (LCM) is used to perform close visual examination of the surface and measurements of corrosion features on the surface. DE containers from FY13 through FY16 were screened with three candidates selected for full circumference evaluation (FCE) according to the ICCWR examination protocol, During the FCE, FY16 DE05 and FY15 DE07 showed suspect major corrosion events, FY16 DE05 Section C2 shows two crack-like features, identified as Denebola and Draco. Both features are located at the boundary of Zone 2 and Zone 3. Consequently, Section C2 of FY16 DE05 was selected for examination by serial metallography at Savannah River National Laboratory (SRNL). For FY15 DE07 the suspect corrosion events were observed on Sections Cl and C2. Section Cl shows one crack-like feature, identified as Acrux. Section C2 shows three crack-like features, identified as Bellatrix, Cursa Minor and Cursa Major. Unlike Acrux and Bellatrix, which are located at the boundary of Zone 2 and Zone 3, Cursa Minor and Cursa Major are located in Zone 2. Sections Cl and C2 of FY15 DE07 were sent to Los Alamos National Laboratory (LANE) for characterization by X-Ray Tomography (XRT).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recursive mass matrix factorization and inversion: An operator approach to open- and closed-chain multibody dynamics

This report advances a linear operator approach for analyzing the dynamics of systems of joint-connected rigid bodies.It is established that the mass matrix M for such a system can be factored as M=(I+H phi L)D(I+H phi L) sup T. This yields an immediate inversion M sup -1=(I-H psi L) sup T D sup -1 (I-H psi L), where H and phi are given by known link geometric parameters, and L, psi and D are obtained recursively by a spatial discrete-step Kalman filter and by the corresponding Riccati equation associated with this filter. The factors (I+H phi L) and (I-H psi L) are lower triangular matrices which are inverses of each other, and D is a diagonal matrix. This factorization and inversion of the mass matrix leads to recursive algortihms for forward dynamics based on spatially recursive filtering and smoothing. The primary motivation for advancing the operator approach is to provide a better means to formulate, analyze and understand spatial recursions in multibody dynamics. This is achieved because the linear operator notation allows manipulation of the equations of motion using a very high-level analytical framework (a spatial operator algebra) that is easy to understand and use. Detailed lower-level recursive algorithms can readily be obtained for inspection from the expressions involving spatial operators. The report consists of two main sections. In Part 1, the problem of serial chain manipulators is analyzed and solved. Extensions to a closed-chain system formed by multiple manipulators moving a common task object are contained in Part 2. To retain ease of exposition in the report, only these two types of multibody systems are considered. However, the same methods can be easily applied to arbitrary multibody systems formed by a collection of joint-connected regid bodies.

Rodriguez, G.↗

Cryogenic electron tomography by the numbers: Charting underexplored lineages in structural cell biology

Imaging cells and their interactions across the whole biosphere with molecular-scale resolution is key for understanding structure–function relations. Cryogenic electron tomography (cryo-ET) is a powerful method for obtaining this critical information. However, cryo-ET studies are challenging and often limited to a small number of cell types per study. Here, we collate cryo-ET data from hundreds of cells and tissues across the biosphere to i) identify emerging methodological trends, ii) pinpoint strategies to reduce imaging time and costs, iii) quantitatively compare methods for cell freezing and sectioning, and iv) census cryo-ET species coverage across all domains of life. Comparing the fraction of cellular material within a single lamella across all domains of life reveals an order of magnitude difference between eukaryotes (1%) compared to bacteria (9%) and archaea (14%). We calculate the fraction of cellular material which can be imaged using distinct sectioning methods on multicellular communities and tissues—identifying serial lift-out as a powerful approach for obtaining more complete cellular depictions. Finally, we show that the biodiversity of current cryo-ET studies is 2 to 3 orders of magnitude lower than in sequence libraries and 4 to 5 lower than the total predicted on Earth. Our analyses reveal major evolutionary lineages which remain critically understudied and highlight where future cryo-ET research would be most impactful.

HPF↗

Establishing reference ranges for circulating biomarkers of drug‐induced liver injury in healthy human volunteers 1

Aims The potential of mechanistic biomarkers to improve prediction of drug‐induced liver injury (DILI) and hepatic regeneration is widely acknowledged. We sought to determine reference intervals for new biomarkers of DILI and regeneration, as well as to characterize their natural variability and impact of diurnal variation. Methods Serum samples from 227 healthy volunteers were recruited as part of a cross‐sectional study; of these, 25 subjects had weekly serial sampling over 3 weeks, while 23 had intensive blood sampling over a 24h period. Alanine aminotransferase (ALT), MicroRNA‐122 (miR‐122), High Mobility Group Box‐1 (HMGB1), total Keratin‐18 (K18), caspase‐cleaved Keratin‐18 (ccK18), Glutamate Dehydrogenase (GLDH) and Macrophage Colony‐Stimulating Factor‐1 (CSF‐1) were assayed. Results Reference intervals were established for each biomarker based on the 97.5% quantile (90% CI) following the assessment of fixed effects in univariate and multivariable models. Intra‐individual variability was found to be non‐significant, and there was no significant impact of diurnal variation. Conclusion Reference intervals for novel DILI biomarkers have been described. An upper limit of a reference range might represent the most appropriate mechanism to utilize these data. These data can now be used to interpret data from exploratory clinical DILI studies and to assist their further qualification as required by regulatory authorities.

Jorgensen, Andrea L. [Department of Health Data Sc↗

An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P <.0001). In contrast to the mitral inflow velocities, mitral annulus early diastolic velocity decreased steadily (12.3-7.3 cm/s) resulting in a dramatic decrease in mitral annulus early/late (1.22-0.57) diastolic velocity with no tendency toward pseudonormalization. The color M-mode Doppler flow propagation velocity also showed significant steady decrease (57-24 cm/s) throughout the pacing period. Multiple regression analysis chose mitral annulus systolic velocity (r = 0.895, P <.0001) and propagation velocity (r = 0.782, P <.0001) for the most important factor predicting LV systolic and diastolic function, respectively. CONCLUSIONS: Doppler tissue echocardiography and color M-mode Doppler flow could evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

Evaluation Studies↗

Soft Real-Time PID Control on a VME Computer

microPID (uPID) is a computer program for real-time proportional + integral + derivative (PID) control of a translation stage in a Fourier-transform ultraviolet spectrometer. microPID implements a PID control loop over a position profile at sampling rate of 8 kHz (sampling period 125microseconds). The software runs in a strippeddown Linux operating system on a VersaModule Eurocard (VME) computer operating in real-time priority queue using an embedded controller, a 16-bit digital-to-analog converter (D/A) board, and a laser-positioning board (LPB). microPID consists of three main parts: (1) VME device-driver routines, (2) software that administers a custom protocol for serial communication with a control computer, and (3) a loop section that obtains the current position from an LPB-driver routine, calculates the ideal position from the profile, and calculates a new voltage command by use of an embedded PID routine all within each sampling period. The voltage command is sent to the D/A board to control the stage. microPID uses special kernel headers to obtain microsecond timing resolution. Inasmuch as microPID implements a single-threaded process and all other processes are disabled, the Linux operating system acts as a soft real-time system.

Karayan, Vahag↗

Three-dimensional surface reconstruction for industrial computed tomography

Modern high resolution medical computed tomography (CT) scanners can produce geometrically accurate sectional images of many types of industrial objects. Computer software has been developed to convert serial CT scans into a three-dimensional surface form, suitable for display on the scanner itself. This software, originally developed for imaging the skull, has been adapted for application to industrial CT scanning, where serial CT scans thrrough an object of interest may be reconstructed to demonstrate spatial relationships in three dimensions that cannot be easily understood using the original slices. The methods of three-dimensional reconstruction and solid modeling are reviewed, and reconstruction in three dimensions from CT scans through familiar objects is demonstrated.

Vannier, M. W.↗

Quantitative order-parameter measurement in lattice-mismatched AlInP using precession electron diffraction

Precession electron diffraction (PED) was used to measure the long-range order parameter in lattice-mismatched AlInP epitaxial films under investigation for solid-state-lighting applications. Both double- and single-variant films grown at 620, 650, and 680°C were analyzed in TEM cross-section. PED patterns were acquired in selected-area-diffraction mode through external microscope control using serial acquisition, which allows inline image processing. The integrated peak intensities from experimental patterns were fit using dynamical simulations of diffraction from the ordered domain structures. Included in the structure-factor calculations were mean atomic displacements of the anions (P) due to ordering, which were found by valence-force-field calculations to have a nearly linear dependence on order parameter. A maximum order parameter of S = 0.36 was measured for a double-variant specimen grown at 650°C.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Intelligent Wireless Sensor Networks for System Health Monitoring

Wireless sensor networks (WSN) based on the IEEE 802.15.4 Personal Area Network (PAN) standard are finding increasing use in the home automation and emerging smart energy markets. The network and application layers, based on the ZigBee 2007 Standard, provide a convenient framework for component-based software that supports customer solutions from multiple vendors. WSNs provide the inherent fault tolerance required for aerospace applications. The Discovery and Systems Health Group at NASA Ames Research Center has been developing WSN technology for use aboard aircraft and spacecraft for System Health Monitoring of structures and life support systems using funding from the NASA Engineering and Safety Center and Exploration Technology Development and Demonstration Program. This technology provides key advantages for low-power, low-cost ancillary sensing systems particularly across pressure interfaces and in areas where it is difficult to run wires. Intelligence for sensor networks could be defined as the capability of forming dynamic sensor networks, allowing high-level application software to identify and address any sensor that joined the network without the use of any centralized database defining the sensors characteristics. The IEEE 1451 Standard defines methods for the management of intelligent sensor systems and the IEEE 1451.4 section defines Transducer Electronic Datasheets (TEDS), which contain key information regarding the sensor characteristics such as name, description, serial number, calibration information and user information such as location within a vehicle. By locating the TEDS information on the wireless sensor itself and enabling access to this information base from the application software, the application can identify the sensor unambiguously and interpret and present the sensor data stream without reference to any other information. The application software is able to read the status of each sensor module, responding in real-time to changes of PAN configuration, providing the appropriate response for maintaining overall sensor system function, even when sensor modules fail or the WSN is reconfigured. The session will present the architecture and technical feasibility of creating fault-tolerant WSNs for aerospace applications based on our application of the technology to a Structural Health Monitoring testbed. The interim results of WSN development and testing including our software architecture for intelligent sensor management will be discussed in the context of the specific tradeoffs required for effective use. Initial certification measurement techniques and test results gauging WSN susceptibility to Radio Frequency interference are introduced as key challenges for technology adoption. A candidate Developmental and Flight Instrumentation implementation using intelligent sensor networks for wind tunnel and flight tests is developed as a guide to understanding key aspects of the aerospace vehicle design, test and operations life cycle.

networks↗

A six degrees of freedom femtosecond laser system for fabrication of small-scale mechanical property specimens

Here, we present the details of a novel ultra-short pulsed laser machining workstation that has been employed for high-throughput laser machining of small-scale mechanical property specimens. This system employs a six degrees of freedom hexapod positioning stage capable of macroscopic movements at high positional accuracy. We developed a methodology that uses quantitative image analysis to measure key parameters required to minimize the hexapod positioning and rotational error. Application of this system to laser machining of small-scale 316L stainless steel tensile specimens and ultra-high molecular weight polyethylene compressive specimens using eucentric tilt and rotation about the specimen axis will be shown, where serial laser milling at a specimen tilt angle of 10° was used to effectively eliminate any taper in the sample cross section that is typically found in laser machining.

47 OTHER INSTRUMENTATION↗

Method for implementation of recursive hierarchical segmentation on parallel computers

A method, computer readable storage, and apparatus for implementing a recursive hierarchical segmentation algorithm on a parallel computing platform. The method includes setting a bottom level of recursion that defines where a recursive division of an image into sections stops dividing, and setting an intermediate level of recursion where the recursive division changes from a parallel implementation into a serial implementation. The segmentation algorithm is implemented according to the set levels. The method can also include setting a convergence check level of recursion with which the first level of recursion communicates with when performing a convergence check.

Tilton, James C.↗

Hexagonal Geometries in MPACT

The MPACT code is a high-fidelity light-water reactor analysis code using whole-core pin-resolved neutron transport calculations on modern parallel-computing hardware. MPACT uses the 2D/1D method to solve 3D neutron transport problems by decomposing the problem into a stack of 2D slices, each of which is solved independently using the method of characteristics (MOC). The slices are then coupled axially using the P3 nodal expansion method (NEM-P3) for the 1D axial calculations. MPACT also employs the coarse mesh finite difference (CMFD) method to accelerate calculations. This manuscript details work supporting advanced reactor designs using hexagonal pins and hexagonal assemblies such as the VVER-1000. If performed correctly, MOC is geometry agnostic. However, MPACT previously had optimizations in place for Cartesian geometries, specifically in the modularization and current calculations. Sections 2 and 3 detail the changes made to MPACT to support MOC and CMFD calculations on hexagonal geometries. Section 4 reports results demonstrating solution consistency for problems run with and without CMFD acceleration, results demonstrating solution consistency when run in serial and parallel, and pincell results using the Monte Carlo code, McCard’s benchmark results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Echocardiographic measurements of left ventricular mass by a non-geometric method

The accuracy of a new nongeometric method for calculating left ventricular myocardial volumes from two-dimensional echocardiographic images was assessed in vitro using 20 formalin-fixed normal human hearts. Serial oblique short-axis images were acquired from one point at 5-deg intervals, for a total of 10-12 cross sections. Echocardiographic myocardial volumes were calculated as the difference between the volumes defined by the epi- and endocardial surfaces. Actual myocardial volumes were determined by water displacement. Volumes ranged from 80 to 174 ml (mean 130.8 ml). Linear regression analysis demonstrated excellent agreement between the echocardiographic and direct measurements.

Parra, Beatriz↗

Cryogenic surface distortion and hysteresis of a 50 cm diameter fused silica mirror cooled to 77 K

A 50 cm diameter, lightweight, Amersil TO8E, fused-natural-quartz mirror with a single arch cross section was tested at the NASA/Ames Research Center Cryogenic Optics Test Facility to measure cryogenic distortion and hysteresis. The mirror was cooled to 77 K in four serial tests and the mirror figure was measured with a phase-measuring interferometer. On the basis of the repeatability of room temperature and cryogenic optical measurements, it was determined that the Single Arch Mirror had no measurable hysteresis and displayed repeatable cryogenic distortion. The Cryogenic Optics Test Facility, optical and thermal test methods, test results, and measurement accuracy are described.

Young, Jeffrey A.↗

Low-frequency sine wave hard-limiting technique

Circuit includes serial-in/parallel-out shift register and weighting network that are used to eliminate effects of noise and other nonrepetitive circuit transients. Register and weighting network average decisions from section of signal where decisions are more dependable or where differences between two consecutive samples are larger.

Anderson, T. O.↗

Development of Multi-Scale X-ray Fluorescence Tomography for Examination of Nanocomposite-Treated Biological Samples

Research in cancer nanotechnology is entering its third decade, and the need to study interactions between nanomaterials and cells remains urgent. Heterogeneity of nanoparticle uptake by different cells and subcellular compartments represent the greatest obstacles to a full understanding of the entire spectrum of nanomaterials’ effects. In this work, we used flow cytometry to evaluate changes in cell cycle associated with non-targeted nanocomposite uptake by individual cells and cell populations. Analogous single cell and cell population changes in nanocomposite uptake were explored by X-ray fluorescence microscopy (XFM). Very few nanoparticles are visible by optical imaging without labeling, but labeling increases nanoparticle complexity and the risk of modified cellular uptake. XFM can be used to evaluate heterogeneity of nanocomposite uptake by directly imaging the metal atoms present in the metal-oxide nanocomposites under investigation. While XFM mapping has been performed iteratively in 2D with the same sample at different resolutions, this study is the first example of serial tomographic imaging at two different resolutions. A cluster of cells exposed to non-targeted nanocomposites was imaged with a micron-sized beam in 3D. Next, the sample was sectioned for immunohistochemistry as well as a high resolution “zoomed in” X-ray fluorescence (XRF) tomography with 80 nm beam spot size. Multiscale XRF tomography will revolutionize our ability to explore cell-to-cell differences in nanomaterial uptake.

60 APPLIED LIFE SCIENCES↗

Retrograde, charnockite- gneiss relations in Southern India

The high-pressure charnockites (P = 8 to 9 Kb., T = 700 to 800 C CO2-rich fluid regime) of the Nilgiri hills show evidence of retrogression related to shear deformation within the Moyar and Bhavani shear belts. Two types of retrogression have been noticed: (1) retrogression along shear planes, and (2) retrogression along pegmatitic veins. Initial stages of retrogression results in the formation of irregular, 2 to 3 cm to one meter wide bleached zones with the removal of greasy grey color of charnockites. Minor structures which were earlier obscured in charnockites are clearly seen in bleached areas. In intensely shear areas, formation of highly fissile grey gneiss results often with the development of flaser and mylonitic structures. Fluid inclusion studies and geochemical investigations carried out for serial samples collected from charnockite to gneiss indicate following features: (1) there is a gradual decrease in density of CO2-rich fluids from 1.073 to 0.821 g/cu cm; (2) interestingly, in many sections of the gneisses studied, there is almost complete absence of fluid inclusions suggesting that they would have decrepitated (this may be due to large pressure difference (2 to 3 Kb.) created between the interior and exterior of the fluid inclusions); and (3) presence of mixed CO2-H2O inclusions were noticed.

Srikantappa, C.↗