Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “serial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Suppressing proximity effects during rapid serial two-photon lithography through tuning of reaction–diffusion kinetics

The ability of two-photon lithography (TPL) to print deterministic nanoporous 3D structures is highly valuable for many applications. However, it is challenging to print such structures rapidly due to the proximity effects that cause closely spaced features to enlarge and merge. A key challenge is the limited understanding of the origins and spatiotemporal dynamics of the long-range proximity effects that extend beyond the optical focal spot. Here, we empirically investigate these proximity effects in serial TPL using custom-made acrylate-based photoresists. We demonstrate that the complex spatiotemporal dynamics of the proximity effects can be explained through the kinetics of the reaction–diffusion photopolymerization mechanisms that underlie the curing process. Specifically, we show that the proximity effects arise due to comparable timescales of reaction and diffusion of oxygen. Furthermore, we demonstrate that long-range proximity effects can be suppressed by introducing phenolic inhibitors, which reduce oxygen consumption through non-inhibiting side reactions and promote faster termination of curing reactions. These insights enabled improving the linewidths from >400 to 260 nm during printing of nanoporous 3D woodpiles at scanning speeds of 50 mm s −1 . Thus, the knowledge generated here can be applied to deterministically tune the proximity effects and enable rapid printing of high-resolution nanoporous 3D structures.

36 MATERIALS SCIENCE↗

In situ counter-diffusion crystallization and long-term crystal preservation in microfluidic fixed targets for serial crystallography

Compared with batch and vapor diffusion methods, counter diffusion can generate larger and higher-quality protein crystals yielding improved diffraction data and higher-resolution structures. Typically, counter-diffusion experiments are conducted in elongated chambers, such as glass capillaries, and the crystals are either directly measured in the capillary or extracted and mounted at the X-ray beamline. Despite the advantages of counter-diffusion protein crystallization, there are few fixed-target devices that utilize counter diffusion for crystallization. In this article, different designs of user-friendly counter-diffusion chambers are presented which can be used to grow large protein crystals in a 2D polymer microfluidic fixed-target chip. Methods for rapid chip fabrication using commercially available thin-film materials such as Mylar, propylene and Kapton are also detailed. Rules of thumb are provided to tune the nucleation and crystal growth to meet users' needs while minimizing sample consumption. These designs provide a reliable approach to forming large crystals and maintaining their hydration for weeks and even months. This allows ample time to grow, select and preserve the best crystal batches before X-ray beam time. Importantly, the fixed-target microfluidic chip has a low background scatter and can be directly used at beamlines without any crystal handling, enabling crystal quality to be preserved. The approach is demonstrated with serial diffraction of photoactive yellow protein, yielding 1.32 Å resolution at room temperature. Fabrication of this standard microfluidic chip with commercially available thin films greatly simplifies fabrication and provides enhanced stability under vacuum. These advances will further broaden microfluidic fixed-target utilization by crystallographers.

Liu, Zhongrui↗

Robust error calibration for serial crystallography

Serial crystallography is an important technique with unique abilities to resolve enzymatic transition states, minimize radiation damage to sensitive metalloenzymes and perform de novo structure determination from micrometre-sized crystals. This technique requires the merging of data from thousands of crystals, making manual identification of errant crystals unfeasible. cctbx.xfel.merge uses filtering to remove problematic data. However, this process is imperfect, and data reduction must be robust to outliers. We add robustness to cctbx.xfel.merge at the step of uncertainty determination for reflection intensities. This step is a critical point for robustness because it is the first step where the data sets are considered as a whole, as opposed to individual lattices. Robustness is conferred by reformulating the error-calibration procedure to have fewer and less stringent statistical assumptions and incorporating the ability to down-weight low-quality lattices. We then apply this method to five macromolecular XFEL data sets and observe the improvements to each. The appropriateness of the intensity uncertainties is demonstrated through internal consistency. This is performed through theoretical CC 1/2 and I /σ relationships and by weighted second moments, which use Wilson's prior to connect intensity uncertainties with their expected distribution. This work presents new mathematical tools to analyze intensity statistics and demonstrates their effectiveness through the often underappreciated process of uncertainty analysis.

Mittan-Moreau, David W.↗

Robust Data-Driven Predictive Run-to-Run Control for Automated Serial Sectioning

This letter presents a one-step predictive run-to-run controller (R2R-MPC) for the automation of mechanical serial sectioning (MSS), a destructive material analysis process. To address the inherent uncertainty and disturbances in the MSS process, a robust closed-loop approach is presented. Here, the robust R2R-MPC models the uncertainty of the MSS process using a linear differential inclusion. As an analytical model of the MSS process is unavailable, the differential inclusion is identified from historical data. The R2R-MPC is posed as an optimization problem that computes incremental changes to the control input which minimize the worst-case material removal errors. This optimization-based controller is combined with a run-to-run controller to provide integral action that rejects constant disturbances and tracks constant reference removal rates. To demonstrate the efficacy of our robust R2R-MPC, we present simulation results which compare the presented controller with a conventional non-robust R2R.

42 ENGINEERING↗

Serial-femtosecond crystallography reveals how a phytochrome variant couples chromophore and protein structural changes

The photoreaction and commensurate structural changes of a chromophore within biological photoreceptors elicit conformational transitions of the protein promoting the switch between deactivated and activated states. We investigated how this coupling is achieved in a bacterial phytochrome variant, Agp2-PAiRFP2. Contrary to classical protein crystallography, which only allows probing (cryo-trapped) stable states, we have used time-resolved serial femtosecond x-ray crystallography (tr-SFX) and pump-probe techniques with various illumination and delay times with respect to photoexcitation of the parent Pfr state. Thus, structural data for seven time frames were sorted into groups of molecular events along the reaction coordinate. They range from chromophore isomerization to the formation of Meta-F, the intermediate that precedes the functional relevant secondary structure transition of the tongue. Structural data for the early events were used to calculate the photoisomerization pathway to complement the experimental data. Late events allow identifying the molecular switch that is linked to the intramolecular proton transfer as a prerequisite for the following structural transitions.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of Serial Testing After Exposure to COVID-19 in Early Care and Education Facilities, Illinois, March–May 2022

Objective: To understand SARS-CoV-2 transmission in early care and education (ECE) settings, we implemented a Test to Stay (TTS) strategy, which allowed children and staff who were close contacts to COVID-19 to remain in person if they agreed to test twice after exposure. We describe SARS-CoV-2 transmission, testing preferences, and the number of in-person days saved among participating ECE facilities. Methods: From March 21 through May 27, 2022, 32 ECE facilities in Illinois implemented TTS. Unvaccinated children and staff who were not up to date with COVID-19 vaccination could participate if exposed to COVID-19. Participants received 2 tests within 7 days after exposure and were given the option to test at home or at the ECE facility. Results: During the study period, 331 TTS participants were exposed to index cases (defined as people attending the ECE facility with a positive SARS-CoV-2 test result during the infectious period); 14 participants tested positive, resulting in a secondary attack rate of 4.2%. No tertiary cases (defined as a person with a positive SARS-CoV-2 test result within 10 days after exposure to a secondary case) occurred in the ECE facilities. Most participants (366 of 383; 95.6%) chose to test at home. Remaining in-person after an exposure to COVID-19 saved approximately 1915 in-person days among children and staff and approximately 1870 parent workdays. Conclusion: SARS-CoV-2 transmission rates were low in ECE facilities during the study period. Serial testing after COVID-19 exposure among children and staff at ECE facilities is a valuable strategy to allow children to remain in person and parents to avoid missing workdays.

Public, Environmental & Occupational Health↗

Fixed Target Serial Data Collection at Diamond Light Source

Serial data collection is a relatively new technique for synchrotron users. A user manual for fixed target data collection at I24, Diamond Light Source is presented with detailed step-by-step instructions, figures, and videos for smooth data collection.

Horrell, Sam↗

Parallel-to-serial biphase-data converter

Data converter produces a serial biphase output signal from parallel input data. Alternate bits are loaded into a shift register in complement form so that the bits appear at the end of the shift register in a true-complement form sequence.

Truelove, R. D.↗

Serial segment method for measuring remnant

For tracking tasks where a sum of sine waves forcing function is used it is often difficult and/or expensive to obtain the pilot's remnant in the vicinity of the sine waves. For the case where each sine wave has at least four times an integer number of cycle per run length, this paper illustrates the serial segments method for measuring remnant power spectral density in a frequency band centered on each sine wave. This method can be implemented on digital, hybrid, or analog Fourier coefficient analyzers, and is particularly advantageous on the latter since properties of Fourier coefficients are exploited to yield both a remnant measure and an improved estimate of the correlated component.

Magdaleno, R. E.↗

The restoration of obliterated stamped serial numbers by ultrasonically induced cavitation in water

Seventeen out of 21 obliterated stamped serial numbers on test specimens of copper, brass, steel, and aluminum were successfully restored. Cavitation induced in water by a piezoelectric transducer was the mechanism used. Primarily, smeared metal was removed from the number grooves by the force of the cavitation, however, numbers were also restored at depths at or below the level of the stamped grooves. The feasibility of this technique as a low cost tool for crime laboratories has been clearly demonstrated. The technique is applicable to a variety of materials, and no previous surface or chemical treatments are necessary.

Young, S. G.↗