Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Study of the Scintillating Properties of Materials Based on Self- Assembling Quantum Dots Embedded into a Semiconductor Bulk

The goal of the project is to investigate scintillating properties of materials based on self-assembled InAs QDs embedded into GaAs bulk. According to theoretical predictions, such materials can have scintillating properties and low self-absorption. Compared to scintillators based on inorganic scintillating crystals, QD-based scintillators could have significantly higher light yield and shorter emission times. We intend to check the theoretical predictions experimentally, measure scintillation parameters and their dependence on the QD-based materials and learn how the properties could be optimized for practical applications.

36 MATERIALS SCIENCE↗

Comparison of neutron spectra measured with three sizes of organic liquid scintillators using differentiation analysis

Proton recoil distributions were obtained by using organic liquid scintillators of different size. The measured distributions are converted to neutron spectra by differentiation analysis for comparison to the unfolded spectra of the largest scintillator. The approximations involved in the differentiation analysis are indicated to have small effects on the precision of neutron spectra measured with the smaller scintillators but introduce significant error for the largest scintillator. In the case of the smallest cylindrical scintillator, nominally 1.2 by 1.3 cm, the efficiency is shown to be insensitive to multiple scattering and to the angular distribution to the incident flux. These characteristics of the smaller scintillator make possible its use to measure scalar flux spectra within media high efficiency is not required.

Shook, D. F.↗

Ionosphere scintillations associated with features of equatorial ionosphere

Amplitude scintillations of radio beacons aboard the ATS-6 satellite on 40 MHz, 140 MHz and 360 MHz recorded during the ATS-6 phase II at an equatorial station Ootacamund (dip 4 deg N) and the ionograms at a nearby station Kodaikanal (dip 3.5 deg N) are examined for scintillation activity. Only sporadic E events, other than Es-q, Es-c or normal E are found to be associated with intense daytime scintillations. Scintillations are also observed during night Es conditions. The amplitude spread is associated with strong scintillations on all frequencies while frequency spread causes weaker scintillations and that mainly at 40 MHz.

Chandra, H.↗

Comparison of Doppler scintillation and in situ spacecraft plasma measurements of interplanetary disturbances

Results are presented of detailed comparisons between Doppler scintillation and in situ plasma measurements to improve the understanding of Doppler scintillation transients. During a combined observing period of nearly 3 mo in 1981-1982 near solar maximum, 22 transients were observed by the Pioneer Venus Orbiter spacecraft and 23 shocks were observed by Helios 1. It is found that at least 84 percent of the transients are shocks, while at least 90 percent of the shocks are transients. Although the temporal profiles of Doppler scintillation and mass flux density are similar, the magnitudes of the Doppler scintillation transients may not simply reflect those of mass flux density. Only one pronounced solar wind event that was observed in the mass flux density measurements showed no signature in the scintillation data; field and particle measurements by Helios 1 suggest that it is a noncompressive density enhancement and/or a magnetic cloud. It is shown that Doppler scintillation measurements can now be used by themselves to detect and locate interplanetary shocks near the sun with a relatively high degree of certainty.

Woo, Richard↗

New Scintillator Materials (K2CeBr5) and (Cs2CeBr5)

Cesium cerium bromide (Cs2CeBr5) and potassium cerium bromide (K2CeBr5) are new scintillator materials for X-ray and gamma ray detector applications. Recently halide scintillator materials, such as Ce doped lanthanum bromide has been proved to be very important material for the same purpose. These materials are highly hygroscopic; a search for high light yield non-hygroscopic materials was highly desirable to advance the scintillator technology. In this paper, we are reporting the crystal growth of novel scintillator materials, cesium cerium bromide (Cs2CeBr5) and potassium cerium bromide (K2CeBr5). Crystals were successfully grown from the melt using the vertical Bridgman-Stockbarger technique, in a comparison with the high performance LaBr3 or LaCl3 crystals, cerium based alkali halides crystals, (Cs2CeBr5) and (K2CeBr5) have similar scintillation properties, while being much less hygroscopic. Furthermore, cesium based compounds will not suffer from the self-activity present in potassium and lanthanum compounds. However the Cs2CeBr5 crystals did not grow properly probably due to non-congruent melting or to some phase transition during cooling. Keywords." Scintillator materials; Ce3+; Energy resolution; Light yield; K2CeBr5

Hawrami, R.↗

Smaller, Lower-Power Fast-Neutron Scintillation Detectors

Scintillation-based fast-neutron detectors that are smaller and less power-hungry than mainstream scintillation-based fast-neutron detectors are undergoing development. There are numerous applications for such detectors in monitoring fast-neutron fluxes from nuclear reactors, nuclear materials, and natural sources, both on Earth and in outer space. A particularly important terrestrial application for small, low-power, portable fast-neutron detectors lies in the requirement to scan for nuclear materials in cargo and baggage arriving at international transportation facilities. The present development of miniature, low-power scintillation-based fast-neutron detectors exploits recent advances in the fabrication of avalanche photodiodes (APDs). Basically, such a detector includes a plastic scintillator, typically between 300 and 400 m thick with very thin silver mirror coating on all its faces except the one bonded to an APD. All photons generated from scintillation are thus internally reflected and eventually directed to the APD. This design affords not only compactness but also tight optical coupling for utilization of a relatively large proportion of the scintillation light. The combination of this tight coupling and the avalanche-multiplication gain (typically between 750 and 1,000) of the APD is expected to have enough sensitivity to enable monitoring of a fast-neutron flux as small as 1,000 cm(exp -2)s(exp -1). Moreover, pulse-height analysis can be expected to provide information on the kinetic energies of incident neutrons. It has been estimated that a complete, fully developed fast-neutron detector of this type, would be characterized by linear dimensions of the order of 10 cm or less, a mass of no more than about 0.5 kg, and a power demand of no more than a few watts.

Patel, Jagdish↗

Impact of Ionospheric Scintillation on Spaceborne SAR Observations Studied Using GNSS

A survey of artifacts seen in JAXA's Phase Array type L-band synthetic aperture radar (PALSAR) data over South America during a low solar activity year is reported in this paper. A significant impact on the radar data is revealed: about 14% of the surveyed PALSAR images (totally 2779) are affected by the artifacts during a month and the artifacts occur on 74.2% of the surveyed days. The characteristics of the artifacts have led to a consideration that the artifacts are the effects of ionospheric scintillation. This raises not only a concern about scintillation effects on radar but also a question about active scintillation conditions during a low solar activity year. To assess and verify the scintillation conditions, GPS data collected from the constellation of FORMOSAT-3/COSMIC satellites and three ground-based GPS networks are processed and analyzed. The GPS data provides a global context and regional dense converge, respectively, of ionospheric irregularity and scintillation measurements. It is concluded tat even during a low solar activity year, L-band scintillation at low latitudes can occur frequently and affect L-band SAR significantly.

remote sensing↗

Subnanosecond Scintillation Detector

A scintillation detector, including a scintillator that emits scintillation; a semiconductor photodetector having a surface area for receiving the scintillation, wherein the surface area has a passivation layer configured to provide a peak quantum efficiency greater than 40% for a first component of the scintillation, and the semiconductor photodetector has built in gain through avalanche multiplication; a coating on the surface area, wherein the coating acts as a bandpass filter that transmits light within a range of wavelengths corresponding to the first component of the scintillation and suppresses transmission of light with wavelengths outside said range of wavelengths; and wherein the surface area, the passivation layer, and the coating are controlled to increase the temporal resolution of the semiconductor photodetector.

Hoenk, Michael↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synergistic effects of Al, Ga, and In doping on ZnO nanorod arrays grown via citrate-assisted hydrothermal technique for highly efficient and fast scintillator screens

To be used as efficient alpha particle scintillator in the fields of nuclear security, nuclear nonproliferation and high-energy physics, scintillator screens must have high light output and fast decay properties. While there has been a great deal of progress in scintillation efficiency, achieving fast decay time properties are still a challenge. In this work, the near band edge (NBE) UV luminescence and alpha particle induced scintillation properties of vertically aligned densely packed ZnO nanorods (NRs) doped with Al, Ga, and In have been thoroughly investigated. The high crystalline hexagonal wurtzite structure with a strong orientation through the c -axis plane (002) and aspect ratios in the range 13–22 have been observed for all ZnO NRs. Electron paramagnetic resonance (EPR) analysis exhibited paramagnetic signals at g ≈ 1.96 for all ZnO NRs. A cost effective green hydrothermal synthesis technique was employed to grow well-aligned NRs. Using citrate as an additive acting as a strong reducing agent in the solution during the crystal growth, defects on the surface are significantly suppressed, thereby enhancing the NBE UV emission. Significantly higher NBE UV emission was observed from the top surface of ZnO NRs in cathodoluminescence (CL) microscopy. Results show that citrate assisted donor doping of ZnO NRs not only reduces the defect emission and NBE self-absorption, but also induces fast decay time (~ 600–700 ps), which makes ZnO NRs a good candidate for fast alpha particle scintillator screens used in associated particle imaging for time and direction tagging of individual neutrons generated in D–T and D–D neutron generators.

36 MATERIALS SCIENCE↗

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A CUPID Li2100MoO4 scintillating bolometer tested in the CROSS underground facility

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

47 OTHER INSTRUMENTATION↗

Scintillator ageing of the T2K near detectors from 2010 to 2021

The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9–2.2% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator. The long component of the attenuation length of the wavelength shifting fibres was observed to degrade by 1.3–5.4% per year, while the short component of the attenuation length did not show any conclusive degradation.

47 OTHER INSTRUMENTATION↗

Impact of temperature on light yield and pulse shape discrimination of polysiloxane-based organic scintillators formulated with commercial resins

This work investigates how increased temperature affects neutron/ discrimination and light yield (LY) in several different polysiloxane-based scintillators doped with either 9,9-dimethyl-2-phenylflourene (PhF) or 2,5-diphenyloxazole (PPO) as a primary fluorophore and 9,9-dimethyl-2,7-di((E)-styryl) fluorene (SFS) as the secondary fluorophore. The polysiloxane matrices were prepared from the commercial resins Wacker Lumisil 579 or Shin-Etsu KER-6000. Control scintillators were prepared from poly(vinyltoluene) (PVT), the industry standard matrix, as a reference point for LY and pulse shape discrimination (PSD) measurements. Samples with PhF and PPO dopant concentrations of 1 wt% and 5 wt% in the polysiloxanes and 3 wt% and 5 wt% in the PVT samples were tested at 20 °C, 35 °C, and 50 °C. In the polysiloxane samples, the KER-6000 resin outperformed the Wacker 579 and PhF proved to be a better dopant than PPO in both LY and PSD capabilities. Polysiloxane scintillators showed slight decreases in LY and increases in neutron/discrimination at increased temperatures, while PVT scintillators showed a similar LY decrease with little to no improvement in neutron/discrimination at increased temperatures. Altogether, polysiloxane scintillators may not require recalibration in applications where temperatures increase up to 50 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DRiFT current mode, trigger settings and flexible detector specifications applied to scintillator arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An approach towards plastic scintillators from thermally activated delayed fluorescent dyes and cross-linkable bismuth compounds

Cross-linked polyvinyltoluene (PVT) based plastic scintillators loaded with dyes exhibiting thermally activated delayed fluorescence (TADF) and various amounts of (caproate)di-(methacrylate) bismuth (CMB) were developed. The co-polymerization of vinyl toluene monomer loaded with different weight ratios of CMB and 1 wt% of TADF dye yielded highly transparent cross-linked plastic scintillators with intense green photoluminescence. The thermal and mechanical properties of the scintillators were investigated using thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and micro indentation techniques. Here, their performance for radiation detection was assessed by performing gamma spectroscopy using a Cs-137 source and benchmarked to commercial plastic scintillators. The loading of CMB was guided by Monte Carlo N-Particle (MCNP) simulations. The results of this study show that the cross-linking approach and the use of TADF dyes yield scintillators with good mechanical properties with a uniaxial yield strength up to ~66 MPa for compositions loaded with 40 wt% of CMB and high optical quality. However, the light yield in gamma spectroscopy experiments is found to be reduced with the addition of CMB, suggesting a trade-off between mechanical yield strength and light yield in gamma spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Silicon Photomultipliers Coupled to Scintillators With the Emission Maximum at 550 nm

A majority of the silicon photomultipliers (SiPMs) are sensitive to blue and near-ultraviolet (NUV) photons that are not optimized for scintillators with the emission maximum at wavelengths longer than 500 nm. The red–green–blue (RGB) SiPM is developed for the maximum photon detection efficiency (PDE) at 550 nm, which is a good match for some high-light-yield scintillators, such as CsI:Tl (CsI) and Gd 1.5 Y 1.5 Ga 2 Al 3 O 12 :Ce (GYGAG). Comparisons are made for the performance of these scintillators coupled to the RGB SiPM and a blue-sensitive SiPM. Because it takes tens of nanoseconds for the microcells to recharge after registering a photon hit, the linearity of these scintillation detectors was studied for high-energy gammas where numerous scintillation photons are generated. In addition, the energy resolution of the 662-keV gamma emitted by 137 Cs was measured for temperatures between –20 °C and 50 °C. The nonlinearity was observed above 1 MeV for all measurements, and however, it can be corrected by energy calibration using a third-degree polynomial. For CsI, the energy resolution is better with the blue-sensitive SiPM because of the lower dark count rate (DCR). In contrast, GYGAG coupled to the RGB SiPM has a better energy resolution for temperatures below 30 °C because of the well-matched emission spectrum and PDE distribution. Nevertheless, the advantage disappears for temperatures above 30 °C due to the higher DCR. It would be useful to further develop the RGB SiPM with a lower DCR and higher operating temperatures.

42 ENGINEERING↗

Performance of Scintillation Detectors Based on Quantum Dots in a Semiconductor Matrix (Final Technical Report)

InAs Quantum Dots (QDs) embedded into GaAs semiconductor waveguide have unique scintillation properties, valuable for nuclear security, medical imaging, and high energy physics. In this work, we developed thick (~25um) epitaxial heterostructres with high luminescence efficiency composed of self-assembled nano-engineered InAs QDs grown by molecular beam epitaxy. In this type of detector, the GaAs matrix acts as a stopping material for charged particles or photons generating electrons captured by the QDs acting as luminescence centers. The QD medium is designed to provide fast capture of electrons into QDs (few ps), high QD luminescence efficiency at room temperature (>50%), and strong red-shift of photoluminescence (PL) from the GaAs absorption edge (>250nm). Typical devices consist of a 10-25um thick GaAs layer with embedded sheets of modulation p-type doped InAs QDs and an InGaAs photodetector tuned to the QD emission wavelength. The thick GaAs layer acts also as a waveguide when layer-transferred onto a low-index substrate. Waveguiding and self-absorption (~1cm -1 ) were studied using photoluminescence with scanning laser excitation and modeled with ray optics approximation and geometrical coupling of high-index waveguide to a collection fiber. Scintillating signals from α-particles were analyzed with both an external photodiode (PD) and an integrated PD which provided an improved optical coupling. In the former case, the external InGaAs PD was air-coupled to the scintillator and had the light collection efficiency of about 1% corresponding to limited light extraction through a planar interface with air due to total internal reflection. The mean charge collected by the integrated PD was in the range of (3÷5)×10 4 photoelectrons per 1 MeV of deposited energy, or ~13-20% of the theoretically achievable light yield. Timing of the integrated device was measured by wire-bonding it to the input of an 8 GHz IC. The scintillation response shows an extremely fast 0.3-0.6 ns decay constant and about 40-70 ps time resolution, limited by the system noise. The combined light yield and decay time makes the InAs/GaAs QD heterostructures the fastest high yield scintillation material reported making it valuable for high energy physics and medical imaging applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗