Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scattered collimator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

First Flight of the Gamma-Ray Imager Polarimeter for Solar Flares (GRIPS) Instrument

The Gamma-Ray Imager/Polarimeter for Solar ares (GRIPS) instrument is a balloon-borne telescope designed to study solar-flare particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in January 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV). Enhanced imaging, spectroscopy and polarimetry of flare emissions in this energy range are needed to study particle acceleration and transport questions. The GRIPS instrument is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the current solar state of the art at HXR/gamma-ray energies, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid modulation collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution less than 1cu mm. For photons that Compton scatter, usually greater or equal to 150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction through Compton imaging. Each of GRIPS's detectors has 298 electrode strips read out with ASIC/FPGA electronics. In GRIPS's energy range, indirect imaging methods provide higher resolution than focusing optics or Compton imaging techniques. The MPRM grid-imaging system has a single-grid design which provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm deep tungsten-copper slats, and quasi-continuous FWHM angular coverage from 12.5-162 arcsecs are achieved by varying the slit pitch between 1-13 mm. This angular resolution is capable of imaging the separate magnetic loop footpoint emissions in a variety of are sizes. In comparison, RHESSI's 35-arcsec resolution at similar energies makes the footpoints resolvable in only the largest ares.

Duncan, Nicole↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a tantalum pentoxide Luneberg lens

A process has been developed for the fabrication of a tantalum pentoxide waveguide Luneburg lens as the input collimator for an optical signal processing circuit on a silicon substrate, such as an integrated wavelength demultiplexer. The development of such a lens involved improvement of the deposition mask profile, reduction of surface scattering by underlaying the lens, reduction of edge scattering by using shims under the mask, and prediction and measurement of the TE-TM polarization aberration. It is shown that polarization aberration significantly affects the design of a demultiplexer system.

Bryan, D. A.↗

Method and apparatus for multiple-projection, dual-energy x-ray absorptiometry scanning

Methods and apparatuses for advanced, multiple-projection, dual-energy X-ray absorptiometry scanning systems include combinations of a conical collimator; a high-resolution two-dimensional detector; a portable, power-capped, variable-exposure-time power supply; an exposure-time control element; calibration monitoring; a three-dimensional anti-scatter-grid; and a gantry-gantry base assembly that permits up to seven projection angles for overlapping beams. Such systems are capable of high precision bone structure measurements that can support three dimensional bone modeling and derivations of bone strength, risk of injury, and efficacy of countermeasures among other properties.

Charles, Jr., Harry K.↗

SWIFT Discovery of Gamma-ray Bursts without Jet Break Feature in their X-ray Afterglows

We analyze Swift gamma-ray bursts (GRBs) and X-ray afterglows for three GRBs with spectroscopic redshift determinations - GRB 050401, XRF 050416a, and GRB 050525a. We find that the relation between spectral peak energy and isotropic energy of prompt emissions (the Amati relation) is consistent with that for the bursts observed in pre-Swift era. However, we find that the X-ray afterglow lightcurves, which extend up to 10 - 70 days, show no sign of the jet break that is expected in the standard framework of collimated outflows. We do so by showing that none of the X-ray afterglow lightcurves in our sample satisfies the relation between the spectral and temporal indices that is predicted for the phase after jet break. The jet break time can be predicted by inverting the tight empirical relation between the peak energy of the spectrum and the collimation-corrected energy of the prompt emission (the Ghirlanda relation). We find that there are no temporal breaks within the predicted time intervals in X-ray band. This requires either that the Ghirlanda relation has a larger scatter than previously thought, that the temporal break in X-rays is masked by some additional source of X-ray emission, or that it does not happen because of some unknown reason.

Sato, G.↗

Highly Collimated Jets and Wide-angle Outflows in HH 46/47: New Evidence from Spitzer Infrared Images

We present new details of the structure and morphology of the jets and outflows in HH 46/47 as seen in Spitzer infrared images from IRAC and MIPS, reprocessed using the 'HiRes' deconvolution technique. HiRes improves the visualization of spatial morphology by enhancing resolution (to subarcsecond levels in IRAC bands) and removing the contaminating side lobes from bright sources. In addition to sharper views of previously reported bow shocks, we have detected (1) the sharply delineated cavity walls of the wide-angle biconical outflow, seen in scattered light on both sides of the protostar, (2) several very narrow jet features at distances approximately 400 AU to approximately 0.1 pc from the star, and (3) compact emissions at MIPS 24 m with the jet heads, tracing the hottest atomic/ionic gas in the bow shocks. Together the IRAC and MIPS images provide a more complete picture of the bow shocks, tracing both the molecular and atomic/ionic gases, respectively. The narrow width and alignment of all jet-related features indicate a high degree of jet collimation and low divergence (width of approximately 400 AU increasing by only a factor of 2.3 over 0.2 pc). The morphology of this jet, bow shocks, wide-angle outflows, and the fact that the jet is nonprecessing and episodic, constrain the mechanisms for producing the jet's entrained molecular gas, and origins of the fast jet, and slower wide-angle outflow.

Herbig-Haro objects↗

Photo-response of the $N=Z$ nucleus $^{24}$Mg

The electric E1 and magnetic M1 dipole responses of the N = Z nucleus 24 Mg were investigated in an inelastic photon scattering experiment. The 13.0 MeV electrons, which were used to produce the unpolarised bremsstrahlung in the entrance channel of the 24 Mg(γ,γ') reaction, were delivered by the ELBE accelerator of the Helmholtz-Zentrum Dresden-Rossendorf. The collimated bremsstrahlung photons excited one J π = 1 – , four J π = 1 + , and six J π = 2 + states in 24 Mg. De-excitation γ rays were detected using the four high-purity germanium detectors of the γELBE setup, which is dedicated to nuclear resonance fluorescence experiments. In the energy region up to 13.0 MeV a total B(M1)↑ = 2.7(3) $μ$$^{2}_{N}$ is observed, but this N = Z nucleus exhibits only marginal E1 strength of less than ΣB(E1)↑≤ 0.61 × 10 –3 e 2 fm 2 . The B(Π1, $1$$^{π}_{i}$ → $2$$^{+}_{1}$)/B(Π1,$1$$^{π}_{i}$ → $0$$^{+}_{gs}$) branching ratios in combination with the expected results from the Alaga rules demonstrate that K is a good approximative quantum number for 24 Mg. The use of the known ρ 2 (E0, $0$$^{+}_{2}$ → $0$$^{+}_{gs}$) strength and the measured B(M1,1 + → $0$$^{+}_{2}$)/B(M1,1 + → $0$$^{+}_{gs}$) branching ratio of the 10.712 MeV 1 + level allows, in a two-state mixing model, an extraction of the difference Δ$β$$^{2}_{2}$ between the prolate ground-state structure and shape-coexisting superdeformed structure built upon the 6432-keV $0$$^{+}_{2}$ level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Combining Particle Tracking with Electromagnetic Radiation Showers: Merging GPT and Geant4 with Visualization

Field emitted electrons can seriously affect the operation of high-field, high-duty factor electron accelerators. Accelerated field emission can result in high average power beams which can radiation damage beamline components. In addition, localized losses generate thermal hot spots whose outgassing degrades the ultra-high vacuum required in photoinjectors and cryomodules. However, despite their importance, the effects of field emission are rarely included in the design and engineering of electron injectors. This work attempts to remedy this situation by combining two well-known and well-documented programs, GPT and Geant4, to track electrons and their losses in an injector beamline. This paper describes a system of programs which simulates electron paths and losses along the beamline. In addition, the tracking results can be zoomed and panned along and about the beampipe envelope using an open-source 3D CAD program. The scattering albedo calculations of the combined program, GPT-Geant4, are shown to be in good agreement with the literature albedos. The paper concludes with a dark current simulation for the LCLS-II injector from the cathode to the collimator at 1.5 m from the cathode.

Dowell, David H.↗

3D-printed B 4 C collimation for neutron pressure cells

A design for an incident-beam collimator for the Paris–Edinburgh pressure cell is described here. This design can be fabricated from reaction-bonded B 4 C but also through fast turnaround, inexpensive 3D-printing. 3D-printing thereby also offers the opportunity of composite collimators whereby the tip closest to the sample can exhibit even better neutronic characteristics. Here, we characterize four such collimators: one from reaction-bonded B 4 C, one 3D-printed and fully infiltrated with cyanoacrylate, a glue, one with a glue-free tip, and one with a tip made from enriched 10 B 4 C. The collimators are evaluated on the Spallation Neutrons and Pressure Diffractometer of the Spallation Neutron Source and the Wide-Angle Neutron Diffractometer at the High Flux Isotope Reactor, both at Oak Ridge National Laboratory. This work clearly shows that 3D-printed collimators perform well and also that composite collimators improve performance even further. Beyond use in the Paris–Edinburgh cell, these findings also open new avenues for collimator designs as clearly more complex shapes are possible through 3D printing. An example of such is shown here with a collimator made for single-crystal samples measured inside a diamond anvil cell. These developments are expected to be highly advantageous for future experimentation in high pressure and other extreme environments and even for the design and deployment of new neutron scattering instruments.

47 OTHER INSTRUMENTATION↗

Optical manifestations of mass outflows from young stars - At atlas of CCD images of Herbig-Haro objects

An attempt is made to provide deep CCD images suitable for tracing the shock-excited and scattered-light components characterizing extended Herbig-Haro complexes. Tabular data include astrometric positions for all stars, shock-excited emission knots, prominent scattered-light patches, as well as an identification for all H-alpha emission objects within the CCD images. It is concluded that: (1) optical outflows are not always accompanied by molecular flows, (2) optical outflows show a higher degree of collimation than their molecular counterparts, and (3) the Herbig-Haro phenomenon is not restricted to low-mass young stellar objects.

Strom, K. M.↗

Comptonization of diffuse ambient radiation by a relativistic jet: The source of gamma rays from blazars?

Recent Energy Gamma Ray Experiment Telescope (EGRET) observations of blazars have revealed strong, variable gamma-ray fluxes with no signatures of gamma-ray absorption by pair production. This radiation probably originates from the inner parts of relativistic jets which are aimed nearly toward us. On sub-parsec scales, the jet will be pervaded by radiation from the broad-line region, as well as by photons from the central continuum source (some of which will be scattered by thermal plasma). In a frame moving with the relativistic outflow, the energy of this ambient radiation would be enhanced. This radiation would be Comptonized by both cold and relativistic electrons in the jet, yielding (in the observer's frame) a collimated beam of X-rays and gamma rays. On the assumption that this process dominates self-Comptonization of synchrotron radiation, we develop a self-consistent model for variable gamma-ray emission, involving a single population of relativistic electrons accelerated by a disturbance in the jet. The spectral break between the X-ray and gamma-ray band, observed in 3C 279 and deduced for other blazars, results from inefficient radiative cooling of lower energy electrons. The existence of such a break strongly favors a model involving Comptonization of an external radiation field over a synchrotron self-Compton model. We derive constraints on such model parameters as the location and speed of the source, its dimensions and internal physical parameters, the maximum photon energies produced in the source, and the density and distribution of ambient radiation. Finally, we discuss how observations might discriminate between our model and alternative ones invoking Comptonization of ambient radiation.

Sikora, Marek↗

Search for X-ray emission from AO0235+164

Limits to the first-order Compton scattering, brightness temperature, and angular size of the compact radio source AO0235+164 were calculated on the basis of a flux density of less than about 1 microJy at 10 to the 18th Hz calculated from observations of the source with the rotating modulation collimator aboard the SAS 3 X-ray observatory. It was found that the maximum brightness temperature at this frequency is less than 2.4 times 10 to the 11th K, corresponding to a minimum angular size of 0.38 msec of arc, assuming the synchrotron self-absorption turnover coefficient is 0.5. On the basis of the distance implied by the largest redshift present, the energy contained in relativistic particles and the magnetic field are calculated, and the ratio of particle to magnetic energy is greater than 10, so the dynamics must be particle dominated. This indicates relativistic expansion if the mean energy per particle is comparable to or greater than the rest of those particles that neutralize the electron plasma.

Dennison, B.↗

Multiple scattering measurements in laboratory and foggy atmosphere

Multiple scattering affects propagation of light beams in turbid media. Backscattering or forward scattering based measurements of atmospheric parameters are influenced by this effect. Although largely studied theoretically, the effect needs measurements in control of situations due to the large variety of situations of practical importance. The results of laboratory measurements pertaining to the transmission of a collimated light beam (Helium-Neon souce, 10 mW) through suspensions of latex spheres in water are presented and a comparison was made with the predictions of calculation in a foggy atmosphere will also be presented.

Bruscaglioni, P.↗

Investigation of breadboard temperature profiling system for SSME fuel preburner diagnostics

The feasibility of measuring temperatures in the space shuttle main engine (SSME) fuel preburner using spontaneous Raman scattering from molecular hydrogen was studied. Laser radiation is transmitted to the preburner through a multimode optical fiber. Backscattered Raman-shifted light is collected and focused into a second fiber which connects to a remote-located spectrograph and a mutlichannel optical detector. Optics collimate and focus laser light from the transmitter fiber defining the probe volume. The high pressure, high temperature preburner environment was simulated by a heated pressure cell. Temperatures determined by the distribution of Q-branch co-vibrational transitions demonstrate precision and accuracy of 3%. It is indicated heat preburner temperatures can be determined with 5% accuracy with spatial resolution less than 1 cm and temporal resolution of 10 millisec at the nominal preburner operation conditions.

Shirley, J. A.↗

Lidar instruments proposed for Eos

Lidar, an acronym for light detection and ranging, represents a class of instruments that utilize lasers to send probe beams into the atmosphere or onto the surface of the Earth and detect the backscattered return in order to measure properties of the atmosphere or surface. The associated technology has matured to the point where two lidar facilities, Geodynamics Laser Ranging System (GLRS), and Laser Atmospheric Wind Sensor (LAWS) were accepted for Phase 2 studies for Eos. A third lidar facility Laser Atmospheric Sounder and Altimeter (LASA), with the lidar experiment EAGLE (Eos Atmospheric Global Lidar Experiment) was proposed for Eos. The generic lidar system has a number of components. They include controlling electronics, laser transmitters, collimating optics, a receiving telescope, spectral filters, detectors, signal chain electronics, and a data system. Lidar systems that measure atmospheric constituents or meteorological parameters record the signal versus time as the beam propagates through the atmosphere. The backscatter arises from molecular (Rayleigh) and aerosol (Mie) scattering, while attenuation arises from molecular and aerosol scattering and absorption. Lidar systems that measure distance to the Earth's surface or retroreflectors in a ranging mode record signals with high temporal resolution over a short time period. The overall characteristics and measurements objectives of the three lidar systems proposed for Eos are given.

Grant, William B.↗

ODERACS 2 White Spheres Optical Calibration Report

This report documents the status of the Orbital Debris Radar Calibration Spheres (ODERACS) 2 white spheres optical calibration study. The purpose of this study is to determine the spectral reflectivity and scattering characteristics in the visible wavelength region for the white spheres that were added to the project in the fall, 1994. Laboratory measurements were performed upon these objects and an analysis of the resulting data was conducted. These measurements are performed by illuminating the objects with a collimated beam of light and measuring the reflected light versus the phase angle. The phase angle is defined as the angle between the light source and the sensor, as viewed from the object. By measuring the reflected signal at the various phase angles, one is able to estimate the reflectance properties of the object. The methodology used in taking the measurements and reducing the data are presented. The results of this study will be used to support the calibration of ground-based optical instruments used in support of space debris research. Visible measurements will be made by the GEODDS, NASA and ILADOT telescopes.

Culp, Robert D.↗

The meV-resolved Inelastic X-ray Scattering Beamline at NSLS-II: Design and Performance

The ultrahigh resolution inelastic X-ray scattering (IXS) beamline at NSLS-II is designed and built to achieve sub-meV resolution at a moderate energy of 9.13 keV for IXS experiments with high momentum resolution and high spectral contrast. The key instrument is a novel spectrometer featuring a new type of analyzer optics, which combines post-sample collimation with angular dispersive crystal optics. As the first user instrument of its kind, the spectrometer has demonstrated unique research capabilities in exploring low momentum transfer (Q), THz dynamics in soft material systems characterized by mesoscopic heterogeneity and complexity, such as liquid crystals and bio-membranes. Ongoing efforts to improve performance since the start of user operations have resulted in a state-of-the-art energy resolution in routine operations of less than 1.4 meV, with sharp Gaussian-like tails, making it a premier IXS spectrometer for studying the dynamics of soft materials, while also delivering competitive performance for investigating phonon dynamics in hard condensed matter systems, including a broad range of quantum materials.

43 PARTICLE ACCELERATORS↗

HARLIE 3-D Aerosol Backscatter and Wind Profile Measurements During Recent Field Experiments: Background Noise Reduction with a Fabry-Perot Etalon Filter in the HARLIE System

Background noise reduction of War signals is one of the most important factors in achieving better signal to noise ratio and precise atmospheric data from Mar measurements. Fahey Perot etalons have been used in several lidar systems as narrow band pass filters in the reduction of scattered sunlight. An slalom with spectral bandwidth, (Delta)v=0.23/cm, free spectral range, FSR=6.7/cm, and diameter, d=24mm was installed in a fiber coupled box which included a 500 pm bandwidth interference Filter. The slalom box couples the telescope and detector with 200 pm core fibers and 21 mm focal length collimators. The angular magnification is M=48. The etalon box was inserted into the Holographic Airborne Rotating Lidar Instrument Experiment (HARLIE) system and tested during the HARGLO-2 intercomparison campaign conducted in November 2001 at Wallops Island, Virginia. This paper presents the preliminary test results of the slalom and a complete analysis will be presented at the conference.

Lee, Sangwoo↗