Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample delivery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Sputter sample preparation for ion beam delivery of radium-223 at ATLAS

A radium-223 ion beam was delivered to an experiment from the electron cyclotron resonance ion source, ECR2, at the Argonne Tandem Linac Accelerator System (ATLAS). Here, the radium-223 material was in a nitrate salt form within a vial, prior to being converted to a usable sputter sample. The sputter sample was produced using a new sample preparation method, where the radium nitrate was dissolved into a solution and pipetted onto pressed aluminum powder. This sample was then allowed to dry, distributing the radium-223 material throughout the sputter sample. Ion source operation using the radium sputter sample is described with the operating parameters listed. The intensity and energy requirements for this ion beam were 1 × 10 6 particles/s and 1.07 GeV, respectively. Because the intensity is relatively low compared to most experiments at ATLAS, previously developed accelerator mass spectrometry methods were used Scott et al. to avoid the need for tuning of the low-intensity beam of interest. Handling of the radium material, as well as loading and unloading of the sputter sample from ECR2, required collaboration with Health Physics. Procedures were used and dry runs were carried out before, during, and after the experiment to ensure the safety of the workers. The processes used and lessons learned are described within.

07 ISOTOPE AND RADIATION SOURCES↗

Collection requirements for trace-element analyses of extraterrestrial samples

Trace-element abundances have proven important in understanding the evolution of and interrelationships between different meteorites. Preliminary investigations of the trace-element contents of interplanetary dust particles indicate that trace-element abundances will prove equally important in distinguishing between micrometeorites of different types, comparing the interplanetary dust to the meteorites, and assessing the degree of thermal alteration experienced either on the parent body or during the collection process. Sample collection, delivery, and curation must be accomplished in a manner to avoid contamination with even trace amounts of the elements to be analyzed. The present SXRF sensitivity for micrometeorite analysis is of order 1 femtogram, but anticipated improvements in sensitivity will require sample contamination substantially below this level. Sample collection and handling equipment should be constructed from materials selected for ultrahigh purity, and serious consideration should be given in selecting the particular set of elements from which the collection apparatus is composed so as not to compromise useful information.

Flynn, George J.↗

Modeling and Testing of Phase Transition-Based Deployable Systems for Small Body Sample Capture

This paper summarizes the modeling, simulation, and testing work related to the development of technology to investigate the potential that shape memory actuation has to provide mechanically simple and affordable solutions for delivering assets to a surface and for sample capture and return. We investigate the structural dynamics and controllability aspects of an adaptive beam carrying an end-effector which, by changing equilibrium phases is able to actively decouple the end-effector dynamics from the spacecraft dynamics during the surface contact phase. Asset delivery and sample capture and return are at the heart of several emerging potential missions to small bodies, such as asteroids and comets, and to the surface of large bodies, such as Titan.

flexible appendage↗

Investigation of Phase Transition-Based Tethered Systems for Small Body Sample Capture

This paper summarizes the modeling, simulation, and testing work related to the development of technology to investigate the potential that shape memory actuation has to provide mechanically simple and affordable solutions for delivering assets to a surface and for sample capture and possible return to Earth. We investigate the structural dynamics and controllability aspects of an adaptive beam carrying an end-effector which, by changing equilibrium phases is able to actively decouple the end-effector dynamics from the spacecraft dynamics during the surface contact phase. Asset delivery and sample capture and return are at the heart of several emerging potential missions to small bodies, such as asteroids and comets, and to the surface of large bodies, such as Titan.

deployable systems↗

Fan-beam intensity modulated proton therapy

Purpose: This paper presents a concept for a proton therapy system capable of delivering intensity modulated proton therapy using a fan beam of protons. This system would allow present and future gantry-based facilities to deliver state-of-the-art proton therapy with the greater normal tissue sparing made possible by intensity modulation techniques.Methods: A method for producing a divergent fan beam of protons using a pair of electromagnetic quadrupoles is described and particle transport through the quadrupole doublet is simulated using a commercially available software package. To manipulate the fan beam of protons, a modulation device is developed. This modulator inserts or retracts acrylic leaves of varying thickness from subsections of the fan beam. Each subsection, or beam channel, creates what effectively becomes a beam spot within the fan area. Each channel is able to provide 0–255 mm of range shift for its associated beam spot, or stop the beam and act as an intensity modulator. Results of particle transport simulations through the quadrupole system are incorporated into the MCNPX Monte Carlo transport code along with a model of the range and intensity modulation device. Several design parameters were investigated and optimized, culminating in the ability to create topotherapy treatment plans using distal-edge tracking on both phantom and patient datasets.Results: Beam transport calculations show that a pair of electromagnetic quadrupoles can be used to create a divergent fan beam of 200 MeV protons over a distance of 2.1 m. The quadrupole lengths were 30 and 48 cm, respectively, with transverse field gradients less than 20 T/m, which is within the range of water-cooled magnets for the quadrupole radii used. MCNPX simulations of topotherapy treatment plans suggest that, when using the distal edge tracking delivery method, many delivery angles are more important than insisting on narrow beam channel widths in order to obtain conformal target coverage. Overall, the sharp distal falloff of a proton depth-dose distribution was found to provide sufficient control over the dose distribution to meet objectives, even with coarse lateral resolution and channel widths as large as 2 cm. Treatment plans on both phantom and patient data show that dose conformity suffers when treatments are delivered from less than approximately ten angles. Treatment time for a sample prostate delivery is estimated to be on the order of 10 min, and neutron production is estimated to be comparable to that found for existing collimated systems.Conclusions: Fan beam proton therapy is a method of delivering intensity modulated proton therapy which may be employed as an alternative to magnetic scanning systems. A fan beam of protons can be created by a set of quadrupole magnets and modified by a dual-purpose range and intensity modulator. This can be used to deliver inversely planned treatments, with spot intensities optimized to meet user defined dose objectives. Additionally, the ability of a fan beam delivery system to effectively treat multiple beam spots simultaneously may provide advantages as compared to spot scanning deliveries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Cold Survivable Distributed Motor Controller (CSDMC)

This paper presents the results of NASA’s COLDTECH development entitled “Cold Survivable Distributed Motor Controller (CSDMC)”. This work addresses the need to lower the mass, power and volume of the motor control electronics and its associated cabling. Landed payload mass of ocean world missions typically requires a spacecraft launch mass of 7-10x the landed mass due to the required propellant to get the payload to the surface. Reduction of landed mass leads to cheaper, more frequent missions and/or increased science return. This work addresses this need by developing a distributed electronics architecture, which places control and power electronics near or at actuators and instruments. The outcome of this effort will result in a 10X reduction in harness mass, enabling a significant increase in science payload which then enables more capable sample acquisition, delivery and analysis systems on these missions. Placing the control and power conversion electronics at or near the actuators or instruments is the cornerstone of our distributed architecture. To do this, we developed the technology necessary to distribute the electronics and place them on a shared interface and power bus. This enables a significant reduction in cable mass along with its associated complexity. This allows spacecraft designers to take advantage of volume at the extremities that would normally not be utilized. In this paper we discuss the technologies and system design to achieve these goals in support of ocean world missions. These technologies include the development of our motor control modules, a point of load regulator and isolated converter modules along with the packaging technology necessary to allow our electronics to survive the extreme temperatures.

Stell, Chris↗

Introduction to Tools and Techniques for Surface Sampling on Europa

The NASA Jet Propulsion Laboratory (JPL) is studying excavation and collection of a sample from an icy surface for a potential landed mission to Europa. Europa presents unique challenges in planetary sampling. Very little is known about the local topography and material composition of the surface. The environmental conditions of being cryogenically cold (80-130K), low gravity (~1/7th Earth), no atmosphere, low lighting conditions, and limited ground in the loop opportunities have forced JPL to look at sampling differently than past missions. Interacting with the surface of the Jovian moon requires a sampling system that is robust to local topography on the scale of the lander and/or the tool. In addition, the sampling system must be capable both of detecting faults and automatically adjusting to them to achieve the mission objectives without ground in the loop feedback. Presented here is an overview of a sampling system concept that involves a two-stage approach for collecting a sample. The first stage uses an excavation tool to prepare the surface site for sample collection by removing the top layer of irradiated material and clearing tailings from the hole. The second stage then generates and collects a sample for delivery to instruments on-board a lander. Also presented is an introduction for how autonomy and sensing technologies might be employed to enable mission success.

Tevere, Erica L.↗

Toxics (Pb, Cd) and trace elements (Zn, Cu, Mn) in women during pregnancy and at delivery, South Benin, 2014–2015

Highlights: • Lack of data on maternal exposure to toxic and trace elements in Africa. • Longitudinal blood measurements of Pb, Cd, Zn, Cu and Mn during pregnancy in Benin. • Evidence of maternal exposure to Pb and Cd. • Identification of potential sources for Pb exposure during pregnancy. During pregnancy, fetal development can be hindered by maternal exposure to toxic elements and abnormal concentrations of trace elements. Few data are available in African countries. Our goal was to assess the body burden of lead (Pb), cadmium (Cd), manganese (Mn), zinc (Zn) and copper (Cu) in pregnant women in Benin. The study was carried out in Sô-Ava district, from November 2015 to April 2016. Sixty women were recruited from the RECIPAL pre-conceptional cohort study. In all women, blood samples were collected during the first trimester of pregnancy. Thirty-two women had additional maternal and cord blood samples collected at delivery. Blood samples were analyzed by inductively coupled plasma mass spectrometry. At delivery, Cd median (IQR) concentration in maternal blood was 0.34 µg/L (0.24–0.46) in this non-smoking population. Pb median (IQR) concentration in maternal blood at delivery was 37.4 µg/L (30.5–52.0), with 31.3% of blood Pb levels above the 50 μg/L threshold. These pregnant women lived in semi-rural lakeside villages. Potential sources of Pb exposure identified during pregnancy were having water supply by drill pump and activities such as smoking fish by the woman and fishing by the household head. At delivery, Zn, Cu, and Mn median (IQR) concentrations in maternal blood were, respectively, 5415 μg/L (4894–5822), 1609 μg/L (1295–1771) and 16.0 μg/L (12.5–20.8). Pb, Cd, Mn and Cu blood concentrations were significantly higher at delivery than during the first trimester of pregnancy. Pb, Cd, Zn and Cu concentrations were significantly lower in cord blood than in maternal blood, contrary to Mn concentration, which was significantly higher in cord blood than in maternal blood at delivery. This exploratory study is the first one performed in Benin, and warns us about exposition of women from Sô-Ava district to Pb and Cd during pregnancy.

54 ENVIRONMENTAL SCIENCES↗

Method and apparatus for chemical and topographical microanalysis

A scanning probe microscope is combined with a laser induced breakdown spectrometer to provide spatially resolved chemical analysis of the surface correlated with the surface topography. Topographical analysis is achieved by scanning a sharp probe across the sample at constant distance from the surface. Chemical analysis is achieved by the means of laser induced breakdown spectroscopy by delivering pulsed laser radiation to the sample surface through the same sharp probe, and consequent collection and analysis of emission spectra from plasma generated on the sample by the laser radiation. The method comprises performing microtopographical analysis of the sample with a scanning probe, selecting a scanned topological site on the sample, generating a plasma plume at the selected scanned topological site, and measuring a spectrum of optical emission from the plasma at the selected scanned topological site. The apparatus comprises a scanning probe, a pulsed laser optically coupled to the probe, an optical spectrometer, and a controller coupled to the scanner, laser and spectrometer for controlling the operation of the scanner, laser and spectrometer. The probe and scanner are used for topographical profiling the sample. The probe is also used for laser radiation delivery to the sample for generating a plasma plume from the sample. Optical emission from the plasma plume is collected and delivered to the optical spectrometer so that analysis of emission spectrum by the optical spectrometer allows for identification of chemical composition of the sample at user selected sites.

Kossakovski, Dmitri A.↗

An Open Port Sampling Interface for Liquid Introduction Atmospheric Pressure Ionization Mass Spectrometry

RATIONALE: A simple method to introduce unprocessed samples into a solvent for rapid characterization by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The continuous flow, self-cleaning open port sampling interface introduced here fills this void. METHODS: The open port sampling interface used a vertically aligned, co-axial tube arrangement enabling solvent delivery to the sampling end of the device through the tubing annulus and solvent aspiration down the center tube and into the mass spectrometer ionization source via the commercial APCI emitter probe. The solvent delivery rate to the interface was set to exceed the aspiration rate creating a continuous sampling interface along with a constant, self-cleaning spillover of solvent from the top of the probe. RESULTS: Using the open port sampling interface with positive ion mode APCI and a hybrid quadrupole time of flight mass spectrometer, rapid, direct sampling and analysis possibilities are exemplified with plastics, ballpoint and felt tip ink pens, skin, and vegetable oils. These results demonstrated that the open port sampling interface could be used as a simple, versatile and self-cleaning system to rapidly introduce multiple types of unprocessed, sometimes highly concentrated and complex, samples into a solvent flow stream for subsequent ionization and analysis by mass spectrometry. The basic setup presented here could be incorporated with any self-aspirating liquid introduction ionization source (e.g., ESI, APCI, APPI, ICP, etc.) or any type of atmospheric pressure sampling ready mass spectrometer system. CONCLUSIONS: The open port sampling interface provides a means to introduce and quickly analyze unprocessed solid or liquid samples with liquid introduction atmospheric pressure ionization source without fear of sampling interface or ionization source contamination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotic Subsurface Analyzer and Sample Handler for Resource Reconnaissance and Preliminary Site Assessment for ISRU Activities at the Lunar Cold Traps

Since the 1960s, claims have been made that water ice deposits should exist in permanently shadowed craters near both lunar poles. Recent interpretations of data from the Lunar Prospector-Neutron Spectrometer (LP- NS) confirm that significant concentrations of hydrogen exist, probably in the form of water ice, in the permanently shadowed polar cold traps. Yet, due to the large spatial resolution (45-60 Ian) of the LP-NS measurements relative to these shadowed craters (approx.5-25 km), these data offer little certainty regarding the precise location, form or distribution of these deposits. Even less is known about how such deposits of water ice might effect lunar regolith physical properties relevant to mining, excavation, water extraction and construction. These uncertainties will need to be addressed in order to validate fundamental lunar In Situ Resource Utilization (ISRU) precepts by 2011. Given the importance of the in situ utilization of water and other resources to the future of space exploration a need arises for the advanced deployment of a robotic and reconfigurable system for physical properties and resource reconnaissance. Based on a collection of high-TRL. designs, the Subsurface Analyzer and Sample Handler (SASH) addresses these needs, particularly determining the location and form of water ice and the physical properties of regolith. SASH would be capable of: (1) subsurface access via drilling, on the order of 3-10 meters into both competent targets (ice, rock) and regolith, (2) down-hole analysis through drill string embedded instrumentation and sensors (Neutron Spectrometer and Microscopic Imager), enabling water ice identification and physical properties measurements; (3) core and unconsolidated sample acquisition from rock and regolith; (4) sample handling and processing, with minimized contamination, sample containerization and delivery to a modular instrument payload. This system would be designed with three mission enabling goals, including: (1) a self-contained, low power, low mass, "black box'' configuration for operations from a lander, various classes of rovers or a surface-based platform with human assistance or robotic anchoring mechanisms; (2) reconfigurable and scalable sample handling for delivery to various types of instrumentation, depending on mission requirements; and (3) the use of advanced automation control and diagnostic techniques that will afford local human deployed, remote teleoperation and fully autonomous intelligent operations. Though a great deal of technology has been advanced toward these objectives, the SASH system faces significant design challenges, including the low gravity environment, various levels of autonomy in operations, radiation exposure, dust contamination, and temperature extremes and deltas. Significant input from the scientific and engineering communities, as well as a significant environmental testing program, will be required to guide the design process.

Gorevan, S. P.↗

Sample Materials Considerations for Curating and Processing Pristine MSR Samples

The perseverance rover is collecting and caching samples of Mars as part of the Mars 2020 mission, which represents the first leg of a multi-mission Mars Sample Return Campaign. The MSR Campaign is an international partnership that will result in delivery of the first martian samples to Earth that were not delivered through meteoritic infall. All meteorites, regardless of how they were handled from recovery to curation, have experienced uncontrolled entry and exposure to the terrestrial environment. Whilst meteorite deliveries are serendipitous, they are also unplanned events that require reactionary responses for recovery and curation. However, with the direct return of pristine astromaterials from another body, we are afforded the ability to design a facility in advance of sample delivery to keep those samples in a pristine (i.e., as returned) state for an indefinite period of time. Given that the curation and processing infrastructure needs to be made out of something, it is important to choose materials for the pristine curation environment that will optimize between the need to effectively process samples and the need to minimize contamination of the samples. The Johnson Space Center (JSC) has an optimized list of materials that have been used in previous sample return missions that includes 304/316 Stainless Steel, Teflon, and T6061 Aluminum (1). This set of materials are compatible with inorganic, organic, and biological cleanliness requirements and protocols. Furthermore, only these materials are permitted to come in contact with pristine samples. We note that JSC uses Neoprene and Hypalon for the gloves on their gloveboxes, but the glove material never comes in direct contact with the samples, only the approved materials. The MSR sample tubes will be made of Ti, so Ti may be an acceptable material for making tools, but the minor and trace element abundances of 304 and 316 stainless steel are well known and do not inhibit scientific investigations of metals, including HSE (2). More work is needed to determine whether the same is true for Ti alloys. In addition to defining the materials in the pristine environment, one must also choose whether the pristine environment will be under vacuum or under a specific atmospheric composition and pressure. Although JAXA has successfully implemented pristine curation vacuum chambers for their Hayabusa and Hayabusa2 samples (3), a vacuum environment is not appropriate for martian samples because it may drive deliquescence of mineral phases in the samples that are sensitive to pressure and relative humidity (4). Consequently, the pristine environment for the martian samples should be under an inert gas. It will be crucial to minimize the number of gases that come into direct contact with samples and these gases will need to be high purity and consistent throughout the pristine isolators. Samples at JSC are stored under high purity gaseous nitrogen (1). Dry N2 gas has not been a problem for N isotope studies for high-T release phases, but an additional inert atmosphere like Ar may be needed for samples where there is a particular concern about low-T release of N from bulk sample analysis. References: (1) McCubbin FM, et al. (2019) Space Science Reviews, 215, 1-81. (2) Day JMD, et al. (2018) Meteorit. Planet. Sci. 53:1283-1291. (3) Yada, T., et al., (2014). Meteorit. Planet. Sci. 49, 135-153. (4) Tosca NJ, et al. (2021). Astrobiology, in press, doi:10.1089/ast.2021.0115.

F M McCubbin↗

The 'sample experiment' on the Mars Rover/Sample Return mission

Sample Experiment denotes the set of all operations that include collection, analysis, packaging, and environmental control of atmospheric and geologic samples of Mars. Various functions may be distributed among surface roving vehicles, stationary landers, and spacecraft but the Sample Experiment remains an integrated mission activity that extends from Mars landing through delivery of the sample payload to the recieving facility on Earth. Technological challenges not faced in previous planetary missions include development of robotic systems to manipulate and characterize samples and to reliably seal them in containers with minimal contamination or degradation.

Gooding, James L.↗

Nucleolin is expressed in patient-derived samples and glioblastoma cells, enabling improved intracellular drug delivery and cytotoxicity

Highlights: • Nucleolin is overexpressed in GSC sub-populations and non-stem glioblastoma cells; • Nucleolin enables intracellular targeted drug delivery in glioblastoma cells; • Nucleolin is overexpressed in glioblastoma patient-derived samples. One of the major challenges in Glioblastoma (GBM) therapy relates with the existence of glioma stem-like cells (GSCs), known to be chemo- and radio-resistant. GSCs and non-stem GBM cells have the ability to interchange, emphasizing the importance of identifying common molecular targets among those cell sub-populations. Nucleolin overexpression has been recently associated with breast cancer sub-populations with different stem-like phenotype. The goal of this work was to evaluate the potential of cell surface nucleolin as a target in GBM cells. Different levels of nucleolin expression resulted in a 3.4-fold higher association of liposomes targeting nucleolin (functionalized with the nucleolin-binding F3 peptide) in U87, relative to GBM11 glioblastoma cells. Moreover, nucleolin was suggested as a potential marker in OCT4-, NANOG-positive GSC, and in the corresponding non-stem GBM cells, as well as in SOX2-positive GSC. Doxorubicin delivered by liposomes targeting nucleolin enabled a level of cytotoxicity that was 2.5- or 4.6-fold higher compared to the non-targeted counterparts. Importantly, an overexpression of nucleolin was also observed in cells of patient-derived samples, as compared with normal brain. Overall, these results suggested nucleolin as a therapeutic target in GBM.

60 APPLIED LIFE SCIENCES↗

SU-F-T-503: Trajectory Modulated Arc Therapy of Intracranial Lesions: Development of a Standardized Path-Based Technique for Fully Dynamic Couch-Gantry Modulated Treatments

Purpose: The integration of couch motion during arc delivery is necessitated to enable irradiation trajectories such as coronal arcs, and to enhance the geometrical sampling for dynamic deliveries to the highest extent. To enable such capability, a platform of Trajectory Modulated Arc Therapy (TMAT) is developed in conjunction with standardized noncollisional dynamic path-set for irradiation of intracranial lesions. Methods: A generalized path-set was constructed through the combination of sagittal arcs (45 degrees from the CAX), axial arcs, and coronal arcs produced through modulation of the dynamic rotation of couch. The standardized path was implemented in a contiguous manner enabling the formation of fully automated sub-trajectories to provide maximal geometrical convergence with minimal number of arcs. Progressive sampling technique is used for direct aperture optimization of the MLCs and the selection of couch positions across the control points. Dosimetry of the resulting plans was assessed relative to clinically delivered plans. Using the TrueBeam Developer Mode, plan deliverability was tested. Results: Treatment planning of TMAT sub-trajectories for central, anterior and posterior tumor sites with volumes ranging from 4.75cc to 107cc demonstrated radically reduced doses to the critical OARs when compared to the clinically treated VMAT. Specifically, percentage reduction in mean dose for critical organs such as brainstem, cochlea, and optic nerve are found to be as low as 74±15%, 50±26% and 74±30% respectively as compared to VMAT. Conformity Index, defined as the ratio of tumor volume (VPTV) and 100% dose volume (V(D100%)), was reduced up to 12% while the Gradient Index, defined as V(D100%)/V(D50%), was concurrently improved by up to 14%. Conclusion: An automated standardized trajectory with dynamically modulated couch-gantry arcs has been developed for intracranial radiotherapy. Through the incorporation of coronal arcs, it is demonstrated that significantly reduced OAR doses can be achieved relative to clinically treated patient plans via VMAT. Research Grant Funding Support by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Advanced manufacturing provides tailor-made solutions for crystallography with x-ray free-electron lasers

Serial crystallography at large facilities, such as x-ray free-electron lasers and synchrotrons, evolved as a powerful method for the high-resolution structural investigation of proteins that are critical for human health, thus advancing drug discovery and novel therapies. However, a critical barrier to successful serial crystallography experiments lies in the efficient handling of the protein microcrystals and solutions at microscales. Microfluidics are the obvious approach for any high-throughput, nano-to-microliter sample handling, that also requires design flexibility and rapid prototyping to deal with the variable shapes, sizes, and density of crystals. Here, we discuss recent advances in polymer 3D printing for microfluidics-based serial crystallography research and present a demonstration of emerging, large-scale, nano-3D printing approaches leading into the future of 3D sample environment and delivery device fabrication from liquid jet gas-dynamic virtual nozzles devices to fixed-target sample environment technology.

36 MATERIALS SCIENCE↗

Demonstrating Reliable High Level Waste Slurry Sampling Techniques to Support Hanford Waste Processing

The Hanford Tank Operations Contractor (TOC) and the Hanford Waste Treatment and Immobilization Plant (WTP) contractor are both engaged in demonstrating mixing, sampling, and transfer system capability using simulated Hanford High-Level Waste (HL W) formulations. This work represents one of the remaining technical issues with the high-level waste treatment mission at Hanford. The TOC must demonstrate the ability to adequately mix and sample high-level waste feed to meet the WTP Waste Acceptance Criteria and Data Quality Objectives. The sampling method employed must support both TOC and WTP requirements. To facilitate information transfer between the two facilities the mixing and sampling demonstrations are led by the One System Integrated Project Team. The One System team, Waste Feed Delivery Mixing and Sampling Program, has developed a full scale sampling loop to demonstrate sampler capability. This paper discusses the full scale sampling loops ability to meet precision and accuracy requirements, including lessons learned during testing. Results of the testing showed that the Isolok(R) sampler chosen for implementation provides precise, repeatable results. The Isolok(R) sampler accuracy as tested did not meet test success criteria. Review of test data and the test platform following testing by a sampling expert identified several issues regarding the sampler used to provide reference material used to judge the Isolok's accuracy. Recommendations were made to obtain new data to evaluate the sampler's accuracy utilizing a reference sampler that follows good sampling protocol.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗