Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “risers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Deployment of a 3D Sonar System at Savannah River: Results, Implications and Next Steps - 19718

Waste solids mapping is required at SRS to support the closure of high level radioactive waste tanks. The current mapping methodologies utilize a combination of video inspections and still camera photos to record the solids location and height in the tank with interpretation by site Engineering personnel. Tank liquid level is recorded during capture of the images to determine the height of solids. If no liquid is present, the images are compared to known waste tank features (e.g., cooling coils, support columns) to determine the height of the solids. In December of 2017, NuVision Engineering and Fortis Engineering conducted a demonstration of Sonar technology in SRS F-Tank Farm (FTF) Tank 7 using three risers (Risers 1, 5, and Center) for the purposes of mapping waste solids in the tank. Tank 7 was not the ideal choice for a 'first-of-a-kind' deployment given its congested internals but was selected based on the priority of tank farm operations. Savannah River Remediation (SRR) evaluated the results of this demonstration against the current solids mapping methodologies to determine potential future application of Sonar technology to support upcoming sludge or salt waste removal, decisions to cease waste removal and perform sampling and analysis, final residuals volume determinations, and applicability for use in H-Tank Farm (HTF) Type IV tanks. The efficiency of the Sonar mapping technology against the current mapping techniques and the relative costs of each were also evaluated. The Sonar demonstration performed in the three risers of Tank 7 resulted in a tank floor coverage of approximately 26%. This limited coverage was primarily due to shadow effects and image distortions created by vertical cooling coils and support columns within the waste tank. A comparison of the images produced during the Sonar demonstration and the historical Tank 7 mapping, performed in 2011 upon completion of Bulk Waste Removal Efforts (BWRE), showed physical similarities between the mounds located near the Sonar deployment risers. The technology performed well in accurately mapping solids in those areas accessible to coverage. The Sonar mapping technology may achieve more benefits if configured to work around internal obstructions, or in a Type IV tank, where the lack of vertical cooling coils may allow for a larger coverage area. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Two-phase flow measurements and observations in a cooling panel of the reactor cavity cooling system

The analysis of the flow behavior within a cooling panel of a scaled water-cooled reactor cavity cooling system has been performed supported by high-resolution measurements of the void fraction at the risers’ outlet. The results have shown a stable, symmetric distribution of the flow through the risers during subcooled boiling conditions, characterized by small, slow bubbles with average void fraction lower than 0.3 for all risers. As the temperature increased to saturation, flow distribution appeared strongly asymmetrical and unstable, with peaks of void fraction as high as 0.9. Large, faster bubbles were observed during these peaks, immediately followed by flow of subcooled liquid water. Flow stagnation and inversion has also been observed. The high resolution void fraction results, complemented by the measurements of the coolant flow rate and temperatures, not only have further described the behavior of the system under hypothetical accident conditions, but represent a unique set of data to support the validation of system-level codes, and more advanced computational tools.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Phase shift method to estimate solids circulation rate in circulating fluidized beds

While solids circulation rate is a critical design and control parameter in circulating fluidized bed (CFB) reactor systems, there are no available techniques to measure it directly at conditions of industrial interest. Cold flow tests have been conducted at NETL in an industrial scale CFB unit where the solids flow has been the topic of research in order to develop an independent method which could be applied to CFBs operating under the erosive and corrosive high temperatures and pressures of a coal fired boiler or gasifier. The dynamic responses of the CFB loop to modest modulated aeration flows in the return leg or standpipe were imposed to establish a periodic response in the unit without causing upset in the process performance. The resulting periodic behavior could then be analyzed with a dynamic model and the average solids circulation rate could be established. This method was applied to the CFB unit operated under a wide range of operating conditions including fast fluidization, core annular flow, dilute and dense transport, and dense suspension upflow. In addition, the system was operated in both low and high total solids inventories to explore the influence of inventory limiting cases on the estimated results. The technique was able to estimate the solids circulation rate for all transport circulating fluidized beds when operating above upper transport velocity, U{sub tr2}. For CFB operating in the fast fluidized bed regime (i.e., U{sub g}< U{sub tr2}), the phase shift technique was not successful. The riser pressure drop becomes independent of the solids circulation rate and the mass flow rate out of the riser does not show modulated behavior even when the riser pressure drop does.

42 ENGINEERING↗

Tank Waste Characterization: History, Challenges, and Success Stories

The preparation and chemical and radiochemical analysis of Hanford tank waste samples can be performed with standard laboratory equipment and instruments as relatively routine processes that are not particularly challenging. Rather, the main challenges of tank waste characterization are associated with radiological dose and sampling limitations. Accurate, representative and effective sampling techniques are difficult with the waste tanks because they were not designed for routine sampling. There are a finite number of sampling locations for each tank based on riser positioning, depth and the operational functionality of the sampling riser. For example, in one recently emptied SST, there was one riser that was found to have had concrete dumped down it, thereby eliminating that sampling port. Additionally, the waste within the tank; especially true for the saltcake and sludge, is not homogenous. The ability to adequately mix a million-gallon double shell tank (DST) is a concern for data reproducibility. Another real challenge that must be addressed for sampling single shell tanks, is how to dissolve the salt cake waste in a compromised (leaking) SST. These physical constraints mean that uncertainty in the representativeness of samples must be considered when applying analytical results to the bulk contents of the tank. The tank waste is highly radioactive and thus can only be handled initially by facilities that can receive samples into concrete-shielded hot cells with remote operation with an example provided in Figure 1. The shielding protects the worker from the radiological dose while mineral oil windows and remotely operated manipulators enables the samples to be handled. At Hanford, analytical laboratories with these hot cell capabilities are limited to the Pacific Northwest National Laboratory and the main Hanford operations support laboratory, 222-S Laboratory. Because of their highly radioactive nature, samples must be sufficiently diluted to facilitate their analysis outside of a shielded cell. In some cases, this means some accuracy must be compromised to complete the analysis beyond that normally encountered for non-radioactive material.

Waste Characterization, BBI, PHOENIX: Tank Farms: ↗

Energy-Saving Melting and Revert Reduction Technology (E-SMARRT), Task 5.3: Casting Porosity-Free Grain Refined Magnesium Alloys

The objective of this project was to identify the root causes for micro-porosity in magnesium alloy castings and recommend remedies that can be implemented in production. Three casting magnesium alloys were used to determine the causes of porosity that is a common problem in the magnesium casting industry. These alloys were AM50A, AM60A, and AZ91D, and all were grain refined with C 2 Cl 6 . Gas porosity was found to have little effect if proper degassing methods and foundry practices were used. It was found that sound gating practice, directional solidification towards the riser and generous risering should always dominate in order to produce sound castings. In sand cast magnesium, thermal gradients were found to be an important indicator of heat transfer in the mold. A minimum thermal gradient was found for each alloy that would produce sound castings. There were 2.02°C/cm for AM50A, 1.99°C/cm for AM60A, and 1.97°C/cm for AZ91D. If these gradients are met or exceeded when an area of the casting reaches 50°C below the liquidus for the alloy, the casting will be free of shrinkage porosity in that area. The cooling rates measured during casting magnesium alloys in a pre-heated step permanent mold ranged from 12°F/min in the three inches thick step to 200o F/min in the one inch step. The effect of the cooling rate on the grain size and the mechanical properties was noticeable but not substantial. Grain refining with C 2 Cl 6 had a marked effect on the grain size of the permanent mold step casting. It reduced it by 10-15% in AM50A and by a factor of six in AZ91E from 300 µm to around 55 µm. The mechanical properties of both permanent mold cast AZ91E and AM50A were improved by grain refinement. The most prominent increase was in the elongation of AM50A that more than doubled from 8% to 17%. Computer simulation of porosity was conducted for a well gated commercial wheel casting. The simulation did not predict significant porosity in the wheel. The mechanical testing of tensile specimens excised from the wheel indeed confirmed good properties, in line with the specifications for this alloy. Evidence of minimal micro-porosity was detected in sections cut from the wheel and investigated under optical microscopy. This finding confirms the key role played by utilizing optimal gating and risering practices in minimizing porosity in magnesium castings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of High-Performance Cast Crankshafts. Final Technical Report

The objective of this project was to develop technologies that would enable the production of cast crankshafts that can replace high performance forged steel crankshafts. To achieve this, the Ultimate Tensile Strength (UTS) of the new material needs to be 850 MPa with a desired minimum Yield Strength (YS; 0.2% offset) of 615 MPa and at least 10% elongation. Perhaps more challenging, the cast material needs to be able to achieve sufficient local fatigue properties to satisfy the durability requirements in today’s high performance gasoline and diesel engine applications. The project team focused on the development of cast steel alloys for application in crankshafts to take advantage of the higher stiffness over other potential material choices. The material and process developed should be able to produce high-performance crankshafts at no more than 110% of the cost of current production cast units, perhaps the most difficult objective to achieve. To minimize costs, the primary alloy design strategy was to design compositions that can achieve the required properties with minimal alloying and post-casting heat treatments. An Integrated Computational Materials Engineering (ICME) based approach was utilized, rather than relying only on traditional trial-and-error methods, which has been proven to accelerate alloy development time. Prototype melt chemistries designed using ICME were cast as test specimens and characterized iteratively to develop an alloy design within a stage-gate process. Standard characterization and material testing was done to validate the alloy performance against design targets and provide feedback to material design and manufacturing process models. Finally, the project called for Caterpillar and General Motors (GM) to develop optimized crankshaft designs using the final material and manufacturing processing path developed. A multi-disciplinary effort was to integrate finite element analyses by engine designers and geometry-specific casting simulations with existing materials models to optimize crankshaft cost and performance. Prototype crankshafts of the final design were to be produced and validated using laboratory bench testing and on-engine durability testing. ICME process simulation tools were used to investigate a broad range of processing concepts. These concepts included casting orientation, various mold and core materials, and various filling and feeding strategies. Each crankshaft was first simulated without gating and risers, which is termed natural solidification. The natural solidification results were used as a baseline for strategy development of each concept. Casting process simulations and ICME tools were proven to be reasonable predictors of real world results. Potential alloys were developed that could meet the project material property goals with appropriate normalization and temper treatments. For the alloys considered, post-normalization temper treatments proved to be necessary to achieve the desired yield strengths and elongations and appropriate heat treatments were designed using ICME tools. The experimental data of all the alloys were analyzed in combination with ICME tools to establish chemistry-process-structure relations. Several GM small gas engine (SGE) crankshafts were successfully cast in sand molds using two different sprue, runner, gate, riser, chill designs. These crankshafts were cast in two different steel alloys developed during the project, but casting finishing (e.g. riser removal) remains a cost challenge. A long list of future work was left unfinished when this project was unexpectedly terminated.

36 MATERIALS SCIENCE↗

Progress Report on Computational Analyses of Water-Based NSTF

CFD analysis has been focused on important component-level phenomena using STARCCM+ to supplement the system analysis of integral system behavior. A notable area of interest was the cavity region. This area is of particular interest for CFD analysis due to the multi-dimensional flow and complex heat transfer (thermal radiation heat transfer and natural convection), which are not simulated directly by RELAP5. CFD simulations allow for the estimation of the boundary heat flux distribution along the riser tubes, which is needed in the RELAP5 simulations. The CFD results can also provide additional data to help establish what level of modeling detail is necessary in RELAP5. It was found that the flow profiles in the cavity region are simpler for the water-based concept than for the air-cooled concept. The local heat flux noticeably increases axially, and is higher in the fins than in the riser tubes. These results were utilized in RELAP5 simulations as boundary conditions, to provide better temperature predictions in the system level analyses. It was also determined that temperatures were higher in the fins than the riser tubes, but within design limits for thermal stresses. Higher temperature predictions were identified in the edge fins, in part due to additional thermal radiation from the side cavity walls.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Model validation using CFD-grade experimental database for NGNP Reactor Cavity Cooling Systems with water and air

This project has been focused on the experimental and numerical investigations of the water-cooled and air-cooled Reactor Cavity Cooling System (RCCS) designs. At this aim, we have leveraged an existing experimental facility at the University of Wisconsin-Madison (UW), and we have designed and built a separate effect test facility at the University of Michigan. The experimental facility at UW has underwent several upgrades, including the installation of advanced instrumentation (i.e. wire-mesh sensors) built at the University of Michigan. These provides highresolution time-resolved measurements of the void-fraction distribution in the risers of the water-cooled RCCS facility. A phenomenological model has been developed to assess the water cooled RCCS system stability and determine the root cause behind the oscillatory behavior that occurs under normal two-phase operation. Testing under various perturbations to the water-cooled RCCS facility have resulted in changes in the stability of the integral system. In particular, the effects on stability of inlet orifices, water tank volume have and system pressure been investigated. MELCOR was used as a predictive tool when performing inlet orificing tests and was able to capture the Density Wave Oscillations (DWOs) that occurred upon reaching saturation in the risers. The experimental and numerical results have then been used to provide RCCS design recommendations. The experimental facility built at the University of Michigan was aimed at the investigation of mixing in the upper plenum of the air-cooled RCCS design. The facility has been equipped with state-of-theart high-resolution instrumentation to achieve so-called CFD grade experiments, that can be used for the validation of Computational Fluid Dynanmics (CFD) models, both RANS (Reynold-Averaged) and LES (Large Eddy Simulations). The effect of risers penetration in the upper plenum has been investigated as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computational Fluid Dynamics Analysis of a 12 MW Circulating Fluidized Bed Rise

A three-dimensional (3D) two fluid model (TFM) model of the 12 MW circulating fluidized bed (CFB) riser at Chalmers University was developed using the open-source Multiphase Flow with Interphase eXchanges (MFiX) Software Suite. The hydrodynamic behavior of the riser was validated by comparing axial pressure profiles from experimental measurements with the results from the simulations. Under some of the operating conditions where there was no external circulation of solids, the pressure profiles from the simulation matched well with the experimental measurements. For the cases where there was external circulation of solids, the pressure profiles with the monodisperse solid phase modeling underpredicted the solids concentration in the freeboard region. With the inclusion of polydispersity in the model, the predicted pressure profiles agreed well with the experimental measurements. A two-dimensional (2D) model of the riser was used to perform simulations of coal combustion. The predicted flue gas outlet compositions of oxygen and carbon dioxide compared reasonably to experiments. The experiments also reported some concentration of carbon monoxide which was overpredicted in the simulations. Additional experimental data such as axial oxygen concentration profile and pressure profiles were also compared with the experiment. It was observed that the oxygen concentration in the bottom bed from the simulations was higher than in the experiments, which suggested that most of the oxidation reactions occurred in the bottom bed. The concentration of volatiles and char in the simulations was lower in the bottom bed than in the experiments, which suggest that there is not sufficient penetration of the solid phase species into the bed.

20 FOSSIL-FUELED POWER PLANTS↗

Evaluation of Crystal Accumulation in High Level Waste Glasses with Research-Scale Melter

The report summarizes the experimental results from a long term Research Scale Melter (RSM) test which was performed at Pacific Northwest National Laboratory (PNNL) in FY16 to answer questions on the effects of spinel crystal accumulation on melter performance and operational longevity. The RSM was used to vitrify a surrogate waste material of the Hanford AZ-101 tank waste composition. This waste contains a high concentration of Fe and Ni and is susceptible to precipitation of a large quantity of spinel crystals during vitrification. The RSM test was run over a period of 11 weeks and consisted of eleven feeding/pouring and idling periods. The feeding/pouring periods were 36 h long while the idling periods ranged from 4 to 7 days. Approximately 509 kg of feed was processed, producing ~159 kg of glass. The main goal of this test was to determine if the riser of the melter can be clogged by accumulated layer of spinel crystals which precipitated from glass during multiple idling’s. In addition, the glass samples were collected during each pouring to evaluate a possibility of a partial or complete removal of crystal deposits accumulated during idling. Furthermore, an electrical conductivity probe was tested for monitoring the crystal accumulation in the riser of the melter during idling’s. The test was concluded by dissecting the melter and preparing cross-sections to determine layer thickness, crystal size and morphology of spinel crystals in the bulk of the melter and in the glass riser.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RECOMMENDATIONS FOR SAMPLING OF TANK 18 IN F TANK FARM

Representative sampling is required for characterization of the residual floor material in Tank 18 prior to operational closure. Tank 18 is an 85-foot diameter, 34-foot high carbon steel tank with nominal operating volume of 1,300,000 gallons. It is a Type IV tank, and has been in service storing radioactive materials since 1959. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual material, Huff and Thaxton [2009] developed a plan to sample the material during the final clean-up process while it would still be resident in sufficient quantities to support analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual floor material separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 18 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 18. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North hemisphere is currently supported by a single Mantis rover sample obtained from a compact region near the center riser. A floor scrape sample was obtained from a compact region near the northeast riser and has been analyzed for a shortened list of key analytes. Since the unused portion of the floor scrape sample material is archived and available in sufficient quantity, additional analyses need to be performed to complete results for the full suite of constituents. The characterization of the full suite of analytes in the South hemisphere is currently supported by a single Mantis rover sample; there have been no floor scrape samples previously taken from the South hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 18 residual floor material, three additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Two of the three additional samples from the North hemisphere and three of the four additional samples from the South hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape samples (the sample previously obtained near NE riser plus the two additional samples that will be analyzed) results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially, the analyte concentrations in the residual material on the floor of Tank 18 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 18 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.

36 MATERIALS SCIENCE↗

Axial dispersion and mixing of coolant gas within a separate-effect prismatic modular reactor

Multiphase Reactors Engineering and Applications Laboratory performed gas phase dispersion experiments in a separate-effect cold-flow experimental setup for coolant flow within heated channels of the prismatic modular reactor under accident scenario using gaseous tracer technique. The separate-effect experimental setup was designed on light of local velocity measurements obtained by using hot wire anemometry. The measurements consist of pulse-response of gas tracer that is flowing through the mimicked riser channel using air as a carrier. The dispersion of the gas phase within the separate-effect riser channel was described using one-dimensional axial dispersion model. The axial dispersion coefficient and Peclet number of the coolant gas phase and their residence time distribution within were measured. Effect of heating intensities in terms of heat fluxes on the coolant gas dispersion along riser channels were mimicked in the current study by a certain range of volumetric air flow rate ranging from 0.0015 to 0.0034 m 3 /s which corresponding to heating intensity range from 200 to 1400 W/m 2 . Results confirm a reduction in the response curve spreads is achieved by increasing the volumetric air velocity (representing heating intensity). Also, the results reveal a reduction in values of axial dispersion coefficient with increasing the air volumetric flow rate.

Said, Ibrahim↗

Spinoff For Deepsea Drillships

For deepwater operations the self-propelled oil drillship is employed. This type of vessel resembles a cargo ship except for its large derrick, which supports the drilling equipment. Extending from the drillship to the well thousands of feet steel tube usually one to two feet in diameter. The drilling equipment, or drill string, is lowered to the well through this riser. The riser is not rigid nor strictly vertical; it is described by one expert as "a very long piece of spaghetti," held in tension at the well and at the ship end by strong cables. Obviously, the ship must remain often for months-in a position directly over the well. If it were to drift excessively forward, aft or to either side, its movement could snap the riser and disrupt operations at a cost of millions. That's where space technology is playing a part. The same technology employed to locate a spacecraft in orbit and maintain a precise position is applicable to drillship operation. In space, automatic navigation equipment sights on reference points-the Earth, the sun or other stars--to determine spacecraft location. If the space mission requires the spacecraft to hold a certain position, it is accomplished by the firing of computer- directed control thrusters. Two major aerospace companies- Honeywell Inc. and TRW Inc.-have applied their extensive experience in spacecraft positioning and control to the offshore drilling technique known as dynamic positioning, meaning holding the drillship in precise position over the work site.

Source record↗

Physical Modeling of Spinel Crystals Settling at Low Reynolds Numbers

The crystallization of large octahedral crystals of spinel during the high-level waste (HLW) vitrification process poses a potential danger to electrically heated ceramic melters. Large spinel crystals rapidly settle under gravitational attraction and accumulate in a thick sludge layer that may partially or completely block the glass discharge riser of the melter. The settling of single particles of different sizes and the motion of hindered settling front of different particle volume fraction suspensions were studied in stagnant, transparent-silicone oils at room temperature to help predict the settling behavior of spinel crystals in the riser. The dimensions and terminal settling velocities of single particles were measured using an optical particle-dynamics-analyzer. The data yielded an experimental shape factor for glass beads that differed only 0.73% compared to the theoretical shape factor for a perfect sphere. The experimental shape factor for the spinel crystals was smaller than that of the beads given the larger drag force caused by the larger surface area to volume ratio of the octahedral crystals, but matched the theoretically predicted value to within 10%. In the hindered settling experiments, both the glass bead and spinel suspensions were found to follow the predictions of the Richardson-Zaki equation with higher particle volume fractions settling at a slower rate. Particle concentration profiles obtained from color threshold analysis (CTA) indicated that for a given volume fraction the rate of clarification increases with an increase in settling vessel angle with respect to the vertical as predicted by the Ponder, Nakamura and Kuroda (PNK) model. The Stokes’, Richardson-Zaki and PNK equations can adequately predict the accumulation rate of spinel crystals in the vertical or inclined glass discharge riser of HLW melters

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the effect of subgrid drag closures

The effect of two subgrid drag closures on the flow of air and Geldart group A particles is presented in this study. A subgrid drag model based on fitting simulation data obtained from finely resolved simulations and a drag model based on the energy minimization approach are both used to solve a gas-solids flow in the riser section of a circulating fluidized bed. The numerical results using a coarse computational grid obtained with these subgrid models are compared with those using a standard drag model as well as experimental data obtained in a pilot-scale riser. Numerical predictions using both subgrid models showed higher solids holdup in the riser indicated by the radial solids density and axial pressure drop profiles in the 2D and 3D system geometries considered in this study. These subgrid models are demonstrated to be both needed and useful as large-scale numerical simulations commonly use coarse computational grids that are unable to resolve the smallest heterogeneous structures observed in the fluidization of small particles.

97 MATHEMATICS AND COMPUTING↗

Apparatus and methods for regeneration of precipitating solvent

A regenerator that can handle rich loaded chemical solvent containing precipitated absorption reaction products is disclosed. The invention is particularly suitable for separating CO.sub.2 from large gas streams that are typical of power plant processes. The internally circulating liquid stream in the regenerator (ICLS regenerator) rapidly heats-up the in-coming rich solvent stream in a downcomer standpipe as well as decreases the overall concentration of CO.sub.2 in the mixed stream. Both these actions lead to dissolution of precipitates. Any remaining precipitate further dissolves as heat is transferred to the mixed solution with an inverted bayonet tube heat exchanger in the riser portion of the regenerator. The evolving CO.sub.2 bubbles in the riser portion of the regenerator lead to substantial gas hold-up and the large density difference between the solutions in the downcomer standpipe and riser portions promotes internal circulation of the liquid stream in the regenerator. As minor amounts of solvent components present in the exit gas stream are condensed and returned back to the regenerator, pure CO.sub.2 gas stream exits the disclosed regenerator and condenser system.

54 ENVIRONMENTAL SCIENCES↗

Flow behaviors in a high-flux circulating fluidized bed - article no. A79

A high-flux circulating fluidized bed coal gasifier cold model which consists of a vertical riser (0.06m-I.D. x 5m-high), two downcomers (0.04m-I.D. x 3.5m-high and 0.1m-I.D. x 3m-high), an inertial separator, a cyclone and two solid feeding devices were established. Geldart group B particles with mean diameters of 140 {mu} m and densities of 2700 kg/m{sup 3} were used as bed materials. Flow behaviors were investigated with the solid mass flux ranges from 108 to 395 kg/m{sup 2} and the superficial gas velocity ranges from 7.6 to 10.2 m/s. The pressure drop, apparent solids holdups, average slip velocity and solids-to-air mass flow ratio under different operating conditions were obtained. The results showed that the riser total pressure drop increased sharply with bed height in the low elevation but slowly in the high elevation, since the solids holdup was higher in the low region than that in the high region. The solids holdup increased with the increasing of solids mass flux while it decreased with increasing superficial gas velocity. A dense suspension upflow flow (DSU) structure was found only existing in the low elevation while the rest upper region was still in the dilute phase, and the length of DSU flow structure increased with solids mass flux. The average slip velocity was found to be the strong function of apparent solids holdup; increasing apparent solids holdup leads to the increase of slip velocity. The riser total pressure drop and apparent solids holdup increase with the solids-to-air mass flow ratio.

01 COAL, LIGNITE, AND PEAT↗