Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resonator temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Fast-Cycle Charge Noise Measurement for Better Qubits

Defects in materials are an ongoing challenge for quantum bits, so called qubits. Solid state qubits—both spins in semiconductors and superconducting qubits—suffer from losses and noise caused by two-level-system (TLS) defects thought to reside on surfaces and in amorphous materials. Understanding and reducing the number of such defects is an ongoing challenge to the field. Superconducting resonators couple to TLS defects and provide a handle that can be used to better understand TLS. We develop noise measurements of superconducting resonators at very low temperatures (20 mK) compared to the resonant frequency, and low powers, down to single photon occupation.

36 MATERIALS SCIENCE↗

One-dimensional temperature measurement of supersonic jet flow by resonantly ionized photoemission thermometry of molecular nitrogen

As the field of fluid dynamics progresses, the demand for sophisticated diagnostic methods to accurately assess flow conditions rises. In this work, resonantly ionized photoemission thermometry (RIPT) has been used to directly target and ionize diatomic nitrogen (N 2 ) to measure one-dimensional (1D) temperature profiles in a supersonic jet flow. This technique can be considered non-intrusive as the premise uses resonantly enhanced multiphoton ionization (REMPI) to target molecular nitrogen. This resonance excites N 2 into absorption bands of the P, Q, and R rotational branches of N 2 ( b 1 Π u ). The ideal (3 + 1) REMPI scheme excites from the ground state and ionizes N 2 ( b 1 Π u ← X 1 Σ g + ) where de-excitation results in photoemission from the first negative band of ionized N 2 + ( B 2 Σ u + → X 2 Σ g + ) as nitrogen returns to the ground state. The resulting emission can be observed using an intensified camera, thus permitting inference of the rotational temperature of ground-state molecular nitrogen. A linearly regressive Boltzmann distribution is applied based on previous calibration data for this technique to quantify the temperature along the ionized line. This work applies this technique to a pure N 2 supersonic jet in cross-flow and counter-flow orientations to demonstrate N 2 RIPT’s applications in a supersonic flow. Temperature variations are observed at different locations downstream of the exit in cross-flow, and axisymmetric in counter-flow, to generate profiles characterizing the flow dynamics. Due to the collisional effects resulting from the number density of N 2 at higher pressures, a (3 + 2) REMPI scheme is observed throughout this text.

Clark, Aleksander (ORCID:0009000855600042)↗

TlCaBaCuO high Tc superconducting microstrip ring resonators designed for 12 GHz

Microwave properties of sputtered Tl-Ca-Ba-Cu-O thin films were investigated by designing, fabricating, and testing microstrip ring resonators. Ring resonators designed for 12 GHz fundamental resonance frequency, were fabricated and tested. From the unloaded Q values for the resonators, the surface resistance was calculated by separating the conductor losses from the total losses. The penetration depth was obtained from the temperature dependence of resonance frequency, assuming that the shift in resonance frequency is mainly due to the temperature dependence of penetration depth. The effective surface resistance at 12 GHz and 77 K was determined to be between 1.5 and 2.75 mOmega, almost an order lower than Cu at the same temperature and frequency. The effective penetration depth at 0 K is approximately 7000 A.

Subramanyam, G.↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Aircraft-based radiometric imaging of tropospheric temperature and precipitation using the 118.75-GHz oxygen resonance

Passive microwave imaging of O2 emissions using the 118.75-GHz resonance has been investigated for tropospheric and stratospheric remote sensing of atmospheric temperature and precipitation. An imaging millimeter-wave spectrometer (MTS) using eight double-sideband channels centered around the 118.75-GHz resonance, and including a fixed-beam 53.65-GHz radiometer and video camera was constructed. The MTS collected data during 33 flights of the NASA-ER-2 high-altitude aircraft in 1986 during GALE and Cohmex, yielding the first high-spatial-resolution microwave images of atmospheric O2 brightness. The isolated 118-GHz line offers higher spatial resolution and precipitation sensitivity than O2 lines in the 5-mm band near 60 GHz. The brightness temperature perturbations of clouds in nonprecipitating regions are typically twice as large in the 118-GHz channels. However, observations over cirrus anvils show that the 118-GHz brightnesses are not adversely sensitive to some optically opaque cloud cover. Thus these channels are expected to be useful for temperature sounding in the presence of clouds, although retrieval ambiguities can result from variations in the water-vapor profile and surface emissivity.

Gasiewski, A. J.↗

High sensitivity real-time NVR monitor

A real time non-volatile residue (NVR) monitor, which utilizes surface acoustic wave (SAW) resonators to detect molecular contamination in a given environment. The SAW resonators operate at a resonant frequency of approximately 200 MHz-2,000 MHz which enables the NVR monitor to detect molecular contamination on the order of 10.sup.-11 g-cm.sup.-2 to 10.sup.-13 g-cm.sup.2. The NVR monitor utilizes active temperature control of (SAW) resonators to achieve a stable resonant frequency. The temperature control system of the NVR monitor is able to directly heat and cool the SAW resonators utilizing a thermoelectric element to maintain the resonators at a present temperature independent of the environmental conditions. In order to enable the direct heating and cooling of the SAW resonators, the SAW resonators are operatively mounted to a heat sink. In one embodiment, the heat sink is located in between the SAW resonators and an electronic circuit board which contains at least a portion of the SAW control electronics. The electrical leads of the SAW resonators are connected through the heat sink to the circuit board via an electronic path which prevents inaccurate frequency measurement.

Bowers, William D.↗

The influence of wall resonances on the levitation of objects in a single-axis acoustic processing chamber

Instabilities were observed in high temperature, single axis acoustic processing chambers. At certain temperatures, strong wall resonances were generated within the processing chamber itself and these transverse resonances were thought sufficient to disrupt the levitation well. These wall resonances are apparently not strong enough to cause instabilities in the levitation well.

Ross, B. B.↗

Ferromagnetic resonators synthesized by metal-organic decomposition epitaxy

Abstract Metal-organic decomposition epitaxy is an economical wet-chemical approach suitable to synthesize high-quality low-spin-damping films for resonator and oscillator applications. This work reports the temperature dependence of ferromagnetic resonances and associated structural and magnetic quantities of yttrium iron garnet nanofilms that coincide with single-crystal values. Despite imperfections originating from wet-chemical deposition and spin coating, the quality factor for out-of-plane and in-plane resonances approaches 600 and 1000, respectively, at room temperature and 40 GHz. These values increase with temperature and are 100 times larger than those offered by commercial devices based on complementary metal-oxide semiconductor voltage-controlled oscillators at comparable production costs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated reference cavity with dual-mode optical thermometry for frequency correction

Photonic integrated resonators have advantages over traditional benchtop cavities in terms of size, weight, and cost with the potential to enable applications that require spectrally pure light. However, integrated resonators suffer from temperature-dependent frequency variations and are sensitive to external environmental perturbations, which hinders their usage in precision frequency applications. One solution is to use interrogation of the cavity temperature through dual-mode optical thermometry (DMOT) by measuring the shift of the resonance frequency difference between two polarization or optical frequency modes. Yet this approach has only been demonstrated in bulk-optic whispering gallery mode and fiber resonators. In this paper, we implement dual-mode optical thermometry in an ultra-high Q integrated silicon nitride resonator. A dual-mode resonance frequency difference temperature sensitivity of 188 ± <#comment/> 15 M H z / K is measured. We demonstrate feedforward DMOT frequency correction that, under an applied external temperature ramp, is able to reduce the optical frequency change to 0.31 kHz/s as compared to an uncorrected 10.03 kHz/s, a factor of 30 × <#comment/> reduction. These results show promise for on-chip frequency correction solutions for quantum, metrology, atomic, and coherent optical communications applications.

Zhao, Qiancheng (ORCID:0000000206968667)↗

A Lack of Spin-Orbit Signal in the Morphology of Mercury's Large Craters

The spatial structure of Mercury's thermal lithosphere depends on the balance between internal heat and surface temperature as controlled by solar insolation. For bodies not in a spin-orbital resonance, observed spatial temperature variations are due to internal heating variations. However, for Mercury's present 3:2 spin-orbit coupling a notable difference of ~150 K exists for the sub-skin depth temperature of the crust as a function of longitude (Fig 1B.; [1,2]). Mercury's longitudinal "hot poles" and "cold poles", in addition to the standard poles (i.e. North and South), have large temperature contrasts that could lead to systematic differences in crater size, morphology, or morphometry, especially for large impacts.

Mercury↗

Electron Paramagentic Resonance Investigation of Mechanism of Light- and Elevated-Temperature-Induced Degradation in Ga-doped Cz Si

We report on the electron paramagnetic resonance (EPR) spectra recorded at 6 K for Ga-doped Czochralski (Cz) Si in the initial stages of light- and elevated-temperature-induced degradation (LeTID). We show that the narrow-range EPR spectrum depends on the duration of simultaneous heat and light exposure. After prolonged LeTID, the EPR intensity increases at ~334 mT. The EPR signature at ~334 mT is characteristic of Si dangling bonds, and the increase in the dangling bond density can be attributed to the bulk and not the surface. Additionally, we show that the inverse of the minority carrier lifetime in Ga-doped Cz Si samples, measured by quasi-steady-state photoconductance (QSSPC) decay, correlates with the increase in the intensity of the Si dangling bond signal measured by EPR. Based on these observations, we put forth a hypothesis connecting H to LeTID and the corresponding defect structure.

Cz Si↗

Surface structure studies in 2D and 3D Nb resonators using GI-XRD

Superconductor radio frequency (SRF) Nb-resonators are a key element in the development of new generations of particle accelerators as well as in the fabrication of 3D circuit QED architecture for quantum computing. Nevertheless, Niobium is extremally reactive to light elements such as C, N, O and H, and therefore to the impurities ordering under special conditions, e.g., cryogenic temperatures. Since these resonators are put through a series of metallurgical and chemical processes, the number of impurities in the solid increases in tens of ppm. Upon operational conditions ~1.6 K, Nb become vulnerable to H atoms ordering, which leads to the nucleation of secondary phases such as Nb-hydrides. Thereupon to the energy dissipation and eventually to the superconductivity breakdown known as Q-disease and potentially High-Field Q-slope. In this contribution, we present a detailed structural analysis by high-energy grazing-incidence X-ray diffraction of specimens extracted from 3D Nb resonators to shed light on the kinetic formation of the resulting secondary phases and their crystal phase identification upon cooling and heating cycles. To our knowledge, this is the first study carried out in resonators samples using a light source, shallow angles and temperatures near ~4 K. Consequently, this work opens new routes to understand the chemical and phase composition, crystal and electronic structure of the Nb surface at temperatures near the operating conditions as a strategy to improve the physical and functional properties of Nb superconducting resonators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Technique for Adjusting Eigenfrequencies of WGM Resonators

A simple technique has been devised for making small, permanent changes in the eigenfrequencies (resonance frequencies) of whispering-gallery-mode (WGM) dielectric optical resonators that have high values of the resonance quality factor (Q). The essence of the technique is to coat the resonator with a thin layer of a transparent polymer having an index of refraction close to that of the resonator material. Successive small frequency adjustments can be made by applying successive coats. The technique was demonstrated on a calcium fluoride resonator to which successive coats of a polymer were applied by use of a hand-made wooden brush. To prevent temperature- related frequency shifts that could interfere with the verification of the effectiveness of this technique, the temperature of the resonator was stabilized by means of a three-stage thermoelectric cooler. Measurements of the resonator spectrum showed the frequency shifts caused by the successive coating layers.

Strekalov, Dmitry↗