Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

sup3ruhi (Super Resolution for Renewable Resource Data and Urban Heat Islands) [SWR-25-05]

Urban heat is a growing concern, particularly in dense metropolitan areas where high temperatures increase the risk of heat-related illness and drive energy expenses for cooling. Estimating the effects of urban heat remains a challenge due to limitations in describing the built environment, computational constraints, and the need for high-resolution data. This software presents open-source, computationally efficient machine learning methods that enhance the accuracy of urban temperature estimates compared to historical reanalysis data. Models trained using this software have been applied to urban microclimates in Los Angeles and Seattle showing greater accuracy and less bias when compared to low-resolution reanalysis datasets like ERA5 and even when compared to high-resolution mesoscale numerical weather models like WRF with an urban canopy model. Initial findings highlight how machine learning can support urban heat resilience planning by enabling improved assessments of local heat islands, mitigation strategies, and their energy implications. This software is an extension of (sup3r). This software supports the following publication: Buster, Grant, et al. Tackling Extreme Urban Heat: A Machine Learning Approach to Assess the Impacts of Climate Change and the Efficacy of Climate Adaptation Strategies in Urban Microclimates. arXiv:2411.05952, arXiv, 8 Nov. 2024. arXiv.org, https://doi.org/10.48550/arXiv.2411.05952. And has related public data records available at: Buster, Grant, Cox, Jordan, Benton, Brandon, and King, Ryan. Super-Resolution for Renewable Resource Data and Urban Heat Islands (Sup3rUHI). United States: N.p., 16 Oct, 2024. Web. https://data.openei.org/submissions/6220.

Buster, Grant [National Renewable Energy Laborator↗

Stochastic frequency fluctuation super-resolution imaging

The inherent non-linearity of intensity correlation functions can be used to spatially distinguish identical emitters beyond the diffraction limit, as achieved, for example, in super-resolution optical fluctuation imaging (SOFI). Here, we propose a complementary concept based on spectral correlation functions, termed spectral fluctuation super-resolution (SFSR) imaging. Through theoretical and computational analysis, we show that spatially resolving time-frequency correlation functions in the image plane can improve the imaging resolution by a factor of $\sqrt2$ in most cases and up to twofold for strictly two emitters. This improvement is achieved by quantifying the degree of correlation in spectral fluctuations across the spatial domain. Experimentally, SFSR can be implemented using a combination of interferometry and photon-correlation measurements. The method works for non-blinking emitters and stochastic spectral fluctuations with arbitrary temporal statistics. This suggests its utility in super-resolution microscopy of quantum emitters at low temperatures, where spectral diffusion is often more pronounced than emitter blinking.

47 OTHER INSTRUMENTATION↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Resolution Computed Tomography Dataset of Mount Simon Sandstone

The Illinois Basin is a critical structure for subsurface energy related activities and their implementation in the United States. The Mount Simon Sandstone has been identified as a storage target for permanent and transient storage of fluids in the basin. Known for its exceptional thickness, depth, porosity, and sealing properties of overlying formations, this saline reservoir is crucial for long-term subsurface energy efforts. We present an extensive Computed Tomography (CT) dataset on a high porosity and permeability zone in the lower Mount Simon Sandstone available on the Energy Data eXchange® (EDX). This publicly accessible database comprises over 500 GB of high-resolution CT scans of six core samples, with resolutions ranging from 14.8 µm to 0.7 µm per pixel. The scans include both dry sandstone samples and those saturated with multiple fluids, allowing for comparative analyses across different conditions and resolutions. Coarser scans capture the bedding structure of the sandstone, while finer resolutions reveal detailed pore infill and throat characteristics. Metadata on location, depth, and saturation state enhance usability, enabling quick identification and cross-sample comparisons. By providing a robust resource for research and collaboration, the database contributes to domestic energy advancement by supporting continued progress in the use of the subsurface for energy solutions.

characterization↗

Evaluation of a high-resolution regional climate simulation for surface and hub-height wind climatology over North America

Assessing the availability of key wind resources requires augmenting observations to support the implementation of wind energy infrastructure. However, observations are limited, necessitating the development of high-resolution, long-term gridded datasets. This study presents a robust, dynamically downscaled climatological dataset, offering 20 years of hourly wind data at a 4 km spatial resolution across North America, and evaluates its performance against observations, including meteorological towers and automated surface-observing system (ASOS) stations, as well as coarse-resolution reanalysis data (the European Centre for Medium-Range Weather Forecasts (ECMWF) reanalysis version 5 (ERA5)). Results demonstrate that the downscaled high-resolution wind data outperform ERA5 in regions of complex terrain and coastal areas, with improved overlap coefficients for wind data distributions and reduced root mean square errors (RMSEs) for hub-height and near-surface diurnal wind patterns. The downscaled simulation also captures the synoptic drivers of seasonal wind direction patterns reasonably well, indicated by high wind rose similarity indices. This study also provides an analysis of interannual variability, utilizing the dataset's full 20-year period, and model uncertainty, generated by varying model initial conditions and physics parameterizations across 1-year ensemble members, which are key considerations for wind resource assessment in wind farm development.

17 WIND ENERGY↗

Resolution requirements for high-speed droplet impact along a rigid wall

The mechanical and thermal loads that are produced on high-speed projectiles from a droplet are key in the projectile development.To accurately predict the pressure produced along the wall surface during impact, it is important to correctly model the air/water interface of the droplet. Novel modeling approaches such as the Phase-Field enable control of the (numerical) interface thickness. However, the interplay between the grid resolution (including potential adaptive mesh refinement) and the interface thickness is unclear. In this work, the resolution requirements for numerical simulations of a two-dimensional cylindrical water droplet impacting a rigid wall at Mach four are computationally investigated. Numerical simulations are performed using a second-order accurate scheme with adaptive mesh refinement and a Phase-Field interface model. The choice of numerical interface thickness and resolution parameters affects the maximum pressure and location of the maximum pressure along the wall. The overall maximum pressure does not converge even at high resolutions. The number of levels and thickness (number of cells across the interface) play a role in obtaining a well behaved solution.

Burrell, E.↗

SHF: Symmetrical Hierarchical Forest with Pretrained Vision Transformer Encoder for High-Resolution Medical Segmentation

This paper presents a novel approach to addressing the long-sequence problem in high-resolution medical images for Vision Transformers (ViTs). Using smaller patches as tokens can enhance ViT performance, but quadratically increases computation and memory requirements. Therefore, the common practice for applying ViTs to high-resolution images is either to: (a) employ complex sub-quadratic attention schemes or (b) use large to medium-sized patches and rely on additional mechanisms within the model to capture the spatial hierarchy of details. We propose Symmetrical Hierarchical Forest (SHF), a lightweight approach that adaptively patches the input image to increase token information density and encode hierarchical spatial structures into the input embedding. We then apply a reverse depatching scheme to the output embeddings of the transformer encoder, eliminating the need for convolution-based decoders. Unlike previous methods that modify attention mechanisms or use a complex hierarchy of interacting models, SHF can be retrofitted to any ViT model to allow it to learn the hierarchical structure of details in high-resolution images without requiring architectural changes. Experimental results demonstrate significant gains in computational efficiency and performance: on the PAIP WSI dataset, we achieved a 3∼32×speedup or a 2.95%∼7.03% increase in accuracy (measured by Dice score) at a 64K2 resolution with the same computational budget, compared to state-of-the-art production models. On the 3D medical datasets BTCV and KiTS, training was 6×faster, with accuracy gains of 6.93% and 5.9%, respectively, compared to models without SHF.

Zhang, Enzhi [Hokkaido University, Japan]↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

High spatial resolution neutron imaging of lithium-ion batteries: Correlating microstructure and lithium transport

Thick electrodes for lithium-ion batteries can increase the overall energy density, but increasing the electrode thickness introduces charge transport limitations. These limitations may be mitigated through proper electrode structuring. Here, high spatial resolution neutron imaging was used to understand the correlation between microstructure and lithium transport in lithium-ion anodes. Batteries with distinct graphite anode microstructures were produced and studied with high spatial resolution in operando neutron radiography to observe the effects of structure on transport. High spatial resolution neutron computed tomography was performed following in operando neutron radiography. X-ray computed tomography and scanning electron microscopy were used to observe the finer scale anode structure to complement neutron imaging. Solvent-free anodes containing a tightly-packed layered structure confined lithium movement close to the separator. This structure limited capacity, but supported better rate capability. Conversely, a more open pore structure in the wet cast anodes yielded higher capacity with reduced rate capability. Together, these results show that lithium distributions can be controlled by the macroscopic structure of the electrodes, the microstructural pore network, and the microscale active areas that support electrochemical reactions. Furthermore, multimodal imaging applying the complementary strengths of neutron and X-ray methods is shown as a tool for advancing battery design.

25 ENERGY STORAGE↗

Development of a Platform for High-Resolution Ion Mobility Separations Coupled with Messenger Tagging Infrared Spectroscopy for High-Precision Structural Characterizations

The ability to uniquely identify a compound requires highly precise and orthogonal measurements. Here we describe a newly developed analytical platform that integrates high resolution ion mobility and cryogenic vibrational ion spectroscopy for high-precision structural characterizations. This platform allows for the temporal separation of isomeric/isobaric ions and provides a highly sensitive description of the ion’s adopted geometry in the gas phase. The combination of these orthogonal structural measurements yields precise descriptors that can be used to resolve between and confidently identify highly similar ions. The unique benefits of our instrument, which integrates a structures for lossless ion manipulations ion mobility (SLIM IM) device with messenger tagging infrared spectroscopy, include the ability to perform high-resolution ion mobility separations and to record the IR spectra of all ions simultaneously. The SLIM IM device, with its 13 m separation path length, allows for multipass experiments to be performed for increased resolution as needed. It is integrated with an Agilent qTOF MS where the collision cell was replaced with a cryogenically held (30 K) TW-SLIM module. The cryo-SLIM is operated in a novel manner that allows ions to be streamed through the device and collisionally cooled to a temperature where they can form noncovalently bound N 2 complexes that are maintained as they exit the device and are detected by the TOF mass analyzer. The instrument can be operated in two modes: IMS+IR where the IR spectra for mobility-selected ions can be recorded and IR-only mode where the IR spectra for all mass-resolved ions can be recorded. In IR-only mode, IR spectra (400 cm –1 spectral range) can be recorded in as short as 2 s for high throughput measurements. Further, this work details the construction of the instrument and modes of operation. It provides initial benchmarking of CCS and IR measurements to demonstrate the utility of this instrument for targeted and untargeted approaches.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Strategies for Overcoming Resolution Limits in Electron Beam Lithography of Chemically Amplified Resists

Electron beam lithography (EBL) of chemically amplified resists (CARs) faces fundamental challenges, including stochastic electron scattering and acid diffusion, that limit resolution and reproducibility. Using SU-8 as a model CAR, this study systematically investigated complementary strategies to address these challenges, combining multipass exposure, proximity effect correction (PEC) with midrange correction factors, base quencher incorporation, and post-exposure bake (PEB) suppression. Monte Carlo simulations and calibrated PEC modeling revealed that extending the point spread function to include a midrange scattering component significantly improved critical dimension (CD) control across varying pattern densities, correcting deviations that conventional two-term PEC failed to capture. Multipass exposure, particularly 4-pass writing with a 25% offset, redistributed the dose to average stochastic beam and scattering fluctuations, reducing line-width roughness by more than 50% and yielding more uniform nanoscale features. Photoacid confinement was investigated by adding urea as a base quencher, which successfully reduced acid diffusion but introduced substantial sensitivity penalties without improving ultimate resolution or Z-factor performance, underscoring the trade-offs of chemical versus physical confinement. Suppressing PEB most directly minimized acid diffusion, resulting in improved Z-factors and reproducible 30 nm half-pitch dense line/space patterns. Overall, these results demonstrated that PEC with midrange correction, multipass strategies, quencher additives, and PEB-free processing addresses different aspects of the EBL process window and that their integration provides a comprehensive framework for managing stochastic scattering, diffusion, and chemical amplification effects. This framework advances dense nanoscale patterning in CARs and establishes guiding principles for optimizing resist design and process strategies in high-resolution EBL and potentially other advanced lithographies, such as extreme ultraviolet (EUV) lithography.

36 MATERIALS SCIENCE↗

Enhanced Simulation of Atmospheric Blocking in a High‐Resolution Earth System Model: Projected Changes and Implications for Extreme Weather Events

Atmospheric blocking is closely linked to the occurrence of extreme weather events. However, low-resolution Earth system models often underestimate the frequency of blocking, undermining confidence in future projections. Here, in this study, we use the high-resolution Community Earth System Model (CESM-HR; 25 km atm and 10 km ocean) to show that CESM-HR reduces biases in atmospheric blocking for both winter and summer, particularly for events lasting longer than 10 days. This improvement is partly due to reduced sea surface temperature biases at higher resolution. Additionally, applying a bias correction to the 500 hPa geopotential height further enhances blocking frequency simulations, highlighting the crucial role of the mean state. Under the Representative Concentration Pathway 8.5 scenario, CESM-HR projects a decrease in wintertime blocking over regions such as the Euro-Atlantic and Chukchi-Alaska, consistent with previous studies. In contrast, summer blocking is expected to become more frequent and persistent, driven by weakened zonal winds. The blocking center shifts from historical locations over Scandinavia and eastern Russia to central Eurasia, significantly increasing blocking over the Ural region. Summer blocking frequency over the Scandinavia-Ural region may eventually surpass historical winter blocking over the Euro-Atlantic. This increase in summer blocking could exacerbate summer heatwaves in a warming climate, making severe heatwaves, like those observed recently, more common in the future.

Atmospheric blocking↗

Desmearing small-angle scattering data by central moment expansions of instrument resolution

This study introduces an enhanced numerical technique tailored specifically for refining 1D small-angle scattering (SAS) intensity profiles affected by smearing. Our primary objective is to address the resolution blurring commonly encountered in SAS data, particularly in systems with clearly defined correlation peaks whose spread aligns with the width of the resolution function at corresponding Q positions. Unlike previous approaches that expanded the SAS intensity using central moment expansion, the new method focuses on expanding the resolution function itself, thus eliminating artificial oscillations observed in smeared spectra due to limitations inherent in our earlier algorithm. This method is straightforward to implement, computationally efficient and consistently performs well in numerical benchmarking. To illustrate its effectiveness, we present a case study of a lamellar phase characterized by distinct peaks in its small-angle neutron scattering intensities.

central moment expansions↗

A High-Speed, High-Resolution Transition Edge Sensor Spectrometer for Soft X-Rays at the Advanced Photon Source

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X-ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molecular Layer Deposited Aluminum‐Based Hybrid Resist for High‐Resolution Nanolithography and Direct Ultra‐High Aspect Ratio Pattern Transfer

Inorganic-containing hybrid photoresists are critical for next-generation extreme ultraviolet (EUV) lithography and angstrom-era semiconductor miniaturization. However, associated conventional solution processing struggles to achieve ultrathin, uniform films with high conformality and compositional control, limiting overall patterning performance. Here, this study reports the systematic lithographic patterning characterization of an Al-based hybrid resist synthesized via vapor-phase molecular layer deposition (MLD), using the trimethylaluminum (TMA) metal precursor and the hydroquinone (HQ) aromatic organic linker. The resist supports both sub-20 nm high-resolution nanolithography and virtually infinite silicon plasma etch selectivity. Lithographic performance studied using electron beam lithography (EBL) as a proxy for EUV shows that, under an optimized process adopting post-exposure bake, the resist achieves the best resolution of 15.4 nm linewidth under stringent 1:1 line-space high-density patterning—limited only by the minimum beam size of the EBL system. The resist also shows wide dose latitude and balanced performance in resolution, roughness, and sensitivity. The infinite silicon etch selectivity, stemming from spontaneous aluminum oxyfluoride passivation layer formation, enables fabrication of micrometer-tall, 40 nm-wide silicon nanofin structures using only a ≈30 nm-thick resist layer, without no hard mask. These results highlight the potential of MLD-based hybrid resists for developing next-generation resist materials for micro/nanoelectronics manufacturing.

36 MATERIALS SCIENCE↗

Central Compact Finite‐Difference Scheme With High Spectral Resolution for KdV Equation

This work presents a combination of cell‐node and cell‐centered compact finite difference scheme for the approximation of third derivatives involved in Korteweg–de Vries (KdV) equations. This approach employs a half‐shifted derivative construction at cell centers, avoiding the need for compact interpolation, thereby removing transfer errors; hence, it improves spectral resolution and maintains high‐order accuracy. Fourier analysis is performed to show the spectral properties of the proposed formulation, which provides higher spectral resolutions as compared to node‐based compact schemes. A filtering strategy is incorporated to suppress high‐frequency oscillations without compromising the accuracy of the numerical scheme, and the total variation diminishing Runge Kutta (TVDRK3) method is applied for time integration. Numerical experiments on linear, nonlinear, and coupled KdV systems are conducted, and a comparative analysis with cell‐node compact schemes confirms that the proposed scheme consistently reduces errors by up to an order of magnitude and achieves high spectral resolution properties.

97 MATHEMATICS AND COMPUTING↗

High-resolution fully-polarimetric synthetic aperture radar dataset

Fully-polarimetric synthetic aperture radar (PolSAR) data contain a rich body of elementary scattering physics information that is critically valuable for a broad range of applications and scientific purposes. However, there is a lack of available high-resolution (< 0.3048-m) data available for PolSAR phenomenology research. This article introduces a high-resolution PolSAR data set collected and provided by Sandia National Laboratories (SNL). The data sets were collected to support studying high-resolution scattering physics from different types of clutter and applications such as polarimetric-based terrain classification.

West, Roger Derek↗