Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rejection sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Muon Time-of-Flight studies for cosmic background rejection in the Short Baseline Near Detector

The Short-Baseline Neutrino (SBN) program at Fermilab is a cutting-edge project in experimental neutrino physics. One of its main goals is to systematically investigate the possible existence of eV-scale sterile neutrinos. This phenomenon has been hypothesized to explain some anomalies found in short-range experiments and, if confirmed, would imply a substantial extension of the Standard Model. SBN also offers an important opportunity to deepen the understanding of neutrino-nucleus interactions in the GeV energy range, through the use of Liquid Argon Time Projection Chambers (LArTPC) detectors, a fundamental technology also for the future DUNE experiment. The SBN experimental infrastructure consists of three detectors aligned along the Booster Neutrino Beamline at Fermilab. Among them, the detector located closest to the neutrino source, SBND (Short-Baseline Near Detector), positioned approximately 110 meters from the target, plays a key role in directly characterizing the initial neutrino flux. This allows for a direct comparison with the measurements from the far detector, ICARUS, located about 600 meters from the source, in order to search for potential signs of anomalous neutrino oscillations. My master's thesis focuses on the commissioning and characterization activities of the SBND detector, with particular reference to the Cosmic Ray Tagger (CRT). The CRT is a subsystem for identifying and rejecting events produced by cosmic rays, which constitute the main source of background for surface experiments like SBND. The activity began with the commissioning of the final components of the detector, as well as their validation to verify their correct functioning and signal acquisition. A central part of my work involved studying the veto efficiency of the CRT system, analyzing the rate of cosmic ray-induced events to quantify any loss of neutrino-induced events caused by cosmic background. This allowed for a more precise evaluation of the systematic impact of the CRT on the useful physics sample. A further phase of my analysis involved an in-depth study of the temporal correlation between the CRT signals and those acquired by the LArTPC's internal photodetector system, consisting of photomultiplier tubes and X-ARAPUCA devices. The objective is to explore the possibility of using combined temporal information as an additional criterion for discriminating between cosmic signals and signals genuinely due to neutrino interaction. Preliminary results indicate the presence of characteristic temporal signatures that could be exploited to improve event selection and increase the purity of the neutrino-induced sample. These methodologies will certainly contribute to the optimization of SBND analysis strategies and, more generally, to a better understanding of background mechanisms in next-generation LArTPC experiments.

Corallo, Annalea [Ferrara U.]↗

Distribution Development for Residual Inventory at the New York West Valley Site - 20400

The New York State Energy Research and Development Authority (NYSERDA) is the owner of the Western New York Nuclear Service Center (WNYNSC), a 1,351 ha site located approximately 48 km south of Buffalo, New York. In 1962, Nuclear Fuel Services, Inc. (NFS) entered into Agreements with the Atomic Energy Commission and New York State to construct the first commercial reprocessing plant of nuclear fuel in the United States. NFS, a private company, built and operated the spent fuel reprocessing plant and waste disposal facilities, processing 640 Mg of spent nuclear fuel from 1966 to 1972 under an Atomic Energy Commission license. Nuclear fuel reprocessing operations ended in 1972 and never reopened, leaving behind radioactive and chemical wastes. Operations led to contamination in a number of facilities and locations. Some of that contamination has migrated from waste disposal zones to other layers, formations, and features on and off the WNYNSC. Phase I decommissioning activities are ongoing and involve the removal of a number of areas and structures that have been associated with contamination. The purpose of this work is to outline the approach for characterizing contamination not associated with disposed wastes, contaminated structures, or specific releases. In this work, the term, residual radiological activity, is used to describe environmental contamination that exists subsequent to the completion of Phase I decommissioning activities, that is not associated with disposed wastes, contaminated structures, or specific releases. Contamination from the Site was quantified relative to data that characterize the concentrations of radionuclides that exist in background. Background concentrations are those present in the area but having no influence from Site related activities. The existence of residual radiological activity that is elevated relative to background has the potential to contribute to future risks to human health and the environment. As a consequence, the residual inventory information is used to inform the West Valley Probabilistic Performance Assessment (PPA) model to characterize potential future risks to human health and the environment. The centralized West Valley Data Management System (DMS) was the source of information for the data assembled in this analysis. The DMS is a fairly large compilation consisting of thousands of records from investigation studies, with sample dates ranging from 1990 to present. Samples from monitoring wells, boreholes, geoprobe studies, surface water, surface soils, storm water outfalls, ventilation stack filters, plant and animal tissues, and more are included in the DMS. Results are typically reported in units of activity per unit volume. For the purpose of the analyses presented here, all results were converted into consistent units of pCi per unit volume. Since 1990, data have been collected from various locations across the WNYNSC at different times with varying frequency over the course of several decades. As a consequence, a number of potential issues can arise with respect to the assembly of a dataset that is deemed adequate for the characterization of residual radiological activity. These issues were assessed and resolved to the extent possible through careful consideration of the properties of the distributions. The intent was to use data which characterize the current state of the Site. Radionuclides can be designated to one of several groups depending on their origin. In this work the groups considered were 1) Naturally Occurring Radioactive Material (NORM), 2) fallout, and 3) Other (including power plant, medical research, etc). This grouping is a useful construct with respect to the interpretation of fixed laboratory results. For example, NORM radionuclides that exist within a decay chain should have approximately equivalent distributions of concentrations if they are representative of background conditions. Insights such as these can be used as a check to identify sample results that need to be further investigated or omitted due to issues associated with reported results from fixed laboratory analyses. This type of analysis provided a foundation for the assessment of the adequacy of sample results for use in subsequent components of an assessment. The general process for the assessment of residual radiological contamination at the Site consists of a sequence of several steps. First, for each analyte, several statistical tests were performed to assess the weight of evidence against the null hypothesis that the mean of the distribution of concentrations was equal to zero. If the mean of the distribution of concentrations for a given radionuclide was not found to be greater than zero, then it was removed from consideration as a component of the residual radiological contamination. If there was significant evidence to reject the hypothesis of the mean being equal to zero, the second step was to compare the distribution of the data from the Site to that of the corresponding background. A suite of tests was used to compare the distributions of the site and background data. The results of these tests were collectively used to determine if site data are elevated relative to background. The third step was to develop distributions using a Bayesian framework to characterize the distribution of mean of the increment present above background for each of the radionuclides. The Bayesian model implemented allowed for the comparison of site-specific records to background concentrations to better approximate contamination attributed to the Site. A final screening step was employed for radionuclides that exceed background. This screening step compared 95% upper confidence limits (UCLs) from the increment distribution developed in the previous step to the risk screening levels. This approach yields a list of analytes that were determined to be elevated relative to background.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovative approach to counterfeit and noncompliant refrigerant detection: A cost-effective, portable solution

The increasing prevalence of counterfeit and incompatible refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVAC&R) systems, including compromised equipment performance, safety hazards, and non-compliance. This article details the development of a novel, cost-effective, and portable detection device designed to accurately verify refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing feedback within a 2-minute duration. Laboratory validation demonstrated the device’s high accuracy (>95 % based on correct identification of compliant vs. non-compliant blends) in detecting unauthorized refrigerant blends. The projected cost of the product stands at ∼ $150, based on the retail pricing of individual components. Laboratory validation demonstrated the device’s high accuracy (>95 % for composition identification, 100 % rejection of tested counterfeit/incorrect blends) in detecting unauthorized refrigerant blends with a response time <2 min. The device correctly identified authentic R-454A/B/C blends and reliably rejected R-407F and closely related counterfeit mixtures. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks, enhances safety in HVAC&R operations, and mitigates the risks associated with counterfeit refrigerants.

Counterfeit refrigerants↗

The Dark Energy Survey supernova program: a reanalysis of cosmology results and evidence for evolving dark energy with an updated Type Ia supernova calibration

We present improved cosmological constraints from a re-analysis of the Dark Energy Survey (DES) 5-year sample of Type Ia supernovae (DES-SN5YR). This re-analysis includes an improved photometric cross-calibration, recent white dwarf observations to cross-calibrate between DES and low-redshift surveys, retraining the salt3 light-curve model and fixing a numerical approximation in the host-galaxy colour law. Our fully recalibrated sample, which we call DES-Dovekie, comprises ~1600 likely Type Ia SNe from DES and ~200 low-redshift SNe from other surveys. With DES-Dovekie, we obtain Ω m = 0.330 ± 0.015 in flat Lambda-cold dark matter (⁠ΛCDM) which changes Ω m by –0.022 compared to DES-SN5YR. Combining DES-Dovekie with cosmic microwave background data from Planck, Atacama Cosmology Telescope, and South Pole Telescope and the DESI DR2 measurements in a flat CDM cosmology, we find ω 0 = –0.803 ± 0.054 and ω a = –0.72 ± 0.21⁠. Our results hold a significance of 3.2σ, reduced from 4.2σ for DES-SN5YR, to reject the null hypothesis that the data are compatible with the cosmological constant. This significance is equivalent to a Bayesian model preference odds of approximately 5:1 in favour of the flat ω 0 ω a CDM model. Using generally accepted thresholds for model preference, our updated data exhibits only a weak preference for evolving dark energy.

dark energy↗

Adversarial methods to reduce simulation bias in neutrino interaction event filtering at liquid argon time projection chambers

For current and future neutrino oscillation experiments using large liquid argon time projection chambers (LAr-TPCs), a key challenge is identifying neutrino interactions from the pervading cosmic-ray background. Rejection of such background is often possible using traditional cut-based selections, but this typically requires the prior use of computationally expensive reconstruction algorithms. This work demonstrates an alternative approach of using a 3D submanifold sparse convolutional network trained on low-level information from the scintillation light signal of interactions inside LAr-TPCs. This technique is applied to example simulations from ICARUS, the far detector of the short baseline neutrino program at Fermilab. The results of the network, show that cosmic background is reduced by up to 76.3% whilst neutrino interaction selection efficiency remains over 98.9%. We further present a way to mitigate potential biases from imperfect input simulations by applying domain adversarial neural networks (DANNs), for which modified simulated samples are introduced to imitate real data and a small portion of them are used for adversarial training. A series of mock-data studies are performed and demonstrate the effectiveness of using DANNs to mitigate biases, showing neutrino interaction selection efficiency performances significantly better than that achieved without the adversarial training.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of neutrino oscillations using neutrino and antineutrino beams in the NOvA experiment

NOvA is a long-baseline accelerator neutrino oscillation experiment using the NuMIneutrino beam from Fermilab. Its main physics goals are to probe the 3-flavour oscillationparameters: neutrino mass hierarchy, CP-violating phase dcp and octant of .23 mixingangle by observing electron neutrino appearance and muon neutrino disappearance. Twofunctionally identical detectors are placed off-axis from the centre of the NuMI beam.The near detector at Fermilab is 100 m underground, and the far detector is locatedon the surface at Ash River, 810 km away from the beam source. The initial neutrinobeam spectra are measured using the near detector data and the oscillation parametersare extracted by fitting the observed data to the predicted neutrino spectrum in the fardetector.This thesis is centered around how to improve the sensitivity of |.m232| and .23 measurementsin the muon neutrino disappearance analysis. NOvA will take data for about12 years. The operation of the NOvA experiment for each year costs tens of millions ofdollars, thus it is valuable to maximise the sensitivity of the analysis. Three samples ofmuon neutrino events are studied in this thesis to improve the analysis sensitivities. First,higher energy muon neutrinos are investigated by extending the energy range in NOvA’scurrent standard analysis. Second, for the sample of events used in NOvA’s existing analysis,a new energy estimator which has been developed to improve the neutrino energy resolution is considered. Furthermore, in addition to binning the events as function ofenergy and hadronic energy fraction, three particle identifiers are introduced to separateneutrino events by signal purity to reduce the effects from backgrounds. Third, an additionallower purity sample of muon neutrino charged current (CC) events that look similarto neutral current events and have not been included in NOvA’s existing analyses havebeen studied.This thesis reanalyses NOvA’s data used in the 2020 analysis, corresponding to anexposure of 13.60×1020 protons on target (POT) in the neutrino beam mode recordedfrom February 6, 2014 to March 20, 2020, and 12.50×1020 protons on target in theantineutrino beam mode recorded between June 29, 2016 to February 26, 2019. Thisthesis has implemented a fit to Asimov fake data, generated where sin2 .23 = 0.59 and.m232 = 2.5 × 10-3 eV2. These sensitivity studies show that the uncertainty range of|.m232| at 1 s in the new analysis is reduced by 5.5% and the significance of maximaldisappearance rejection improves by 7.7%, compared to the standard analysis. This isequivalent to adding 11-16% more data. The best fit values of the oscillation parametersfrom fitting to the far detector (FD) data with the new analysis are found to besin2 .23 = 0.568+0.025-0.043 (sin2 .23 = 0.454+0.046-0.026) and .m232 = 2.399+0.055-0.070 × 10-3 eV2 (.m232= -2.427+0.055-0.067 × 10-3 eV2) for the normal (inverted) hierarchy. The difference in thebest fit for sin2 .23 (.m232) between the new analysis and NOvA’s 2020 analysis is around2% (1.4%). The uncertainty range at 1 s for .m232 decrease by 8% (4%) for the normalhierarchy (inverted hierarchy) compared to the standard analysis. The uncertainty rangefor sin2 .23 is close to the standard analysis. This thesis also implements the fit from combiningelectron neutrino appearance and muon neutrino disappearance. The combinedanalysis shows that the best fit values are very close to the standard analysis. However,the uncertainty range of .m232 at 1 s is reduced by 3.7% using the new analysis. The maximaldisappearance significance is not improved in the new analysis, but the new analysisslightly improves the rejection of the disfavoured octant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the Impact of Copper Oxide Substitution on Structure, Morphology, Bioactivity, and Electrical Properties of 45S5 Bioglass®

In recent decades, the requirements for implantable medical devices have increased, but the risks of implant rejection still exist. These issues are primarily associated with poor osseointegration, leading to biofilm formation on the implant surface. This study focuses on addressing these issues by developing a biomaterial for implant coatings. 45S5 bioglass® has been widely used in tissue engineering due to its ability to form a hydroxyapatite layer, ensuring a strong bond between the hard tissue and the bioglass. In this context, 45S5 bioglasses®, modified by the incorporation of different amounts of copper oxide, from 0 to 8 mol%, were synthesized by the melt–quenching technique. The incorporation of Cu ions did not show a significant change in the glass structure. Since the bioglass exhibited the capacity for being polarized, thereby promoting the osseointegration effectiveness, the electrical properties of the prepared samples were studied using the impedance spectroscopy method, in the frequency range of 102–106 Hz and temperature range of 200–400 K. The effects of CuO on charge transport mobility were investigated. Additionally, the bioactivity of the modified bioglasses was evaluated through immersion tests in simulated body fluid. The results revealed the initiation of a Ca–P-rich layer formation on the surface within 24 h, indicating the potential of the bioglasses to enhance the bone regeneration process.

Hammami, Imen (ORCID:0000000290072221)↗

Performance of pumped counterflow virtual impactors to study aerosol interactions with laboratory generated warm clouds

Pumped Counterflow Virtual Impactors (PCVI) are designed to separate aerosols based on aerodynamic diameter, which is particularly useful for isolating cloud droplets and ice crystals from smaller particles. However, the PCVI transmission efficiency (TE) values reported in the literature show considerable variability, and little information is available on the TEs for cloud liquid droplets. Here, we determined the optimal flow conditions for PCVI sampling for different activation ratios from the MTU Pi-cloud chamber, highlighting the conditions that maximize droplet residual sampling while minimizing interstitial transmission. Even for a lower limit cloud activation ratio = 1:10, an add flow of 1.5 LPM achieves a residual fraction greater than 0.80, with a droplet TE of ∼15% for typical Pi-Chamber droplets with diameters between 3.5 to 10 µm. This framework can be adapted for field cloud measurements based on the cloud conditions of interest. TE for cloud droplets under flow conditions at which ∼99% of the unactivated submicron particles were removed was substantially lower between 8 and 16% than for supermicron dry particles (∼30 to 40% for 3 µm polystyrene latex spheres). In addition, we conducted a comparison of the performances of three similar PCVI units to assess repeatability for dry aerosols and cloud droplets. All three PCVIs performed similarly in rejecting submicron particles smaller than the desired cutoff diameter. One of the units showed lower TEs due to a misalignment of the internal orifice. We discuss a procedure that improved alignment and performance.

54 ENVIRONMENTAL SCIENCES↗

SDSS-IV MaNGA: a catalogue of spectroscopically detected strong galaxy–galaxy lens candidates

ABSTRACT We spectroscopically detected candidate emission-lines of 8 likely, 17 probable, and 69 possible strong galaxy–galaxy gravitational lens candidates found within the spectra of $\approx 10\, 000$ galaxy targets contained within the completed Mapping of Nearby Galaxies at Apache Point Observatory survey. This search is based upon the methodology of the Spectroscopic Identification of Lensing Objects project, which extends the spectroscopic detection methods of the BOSS Emission-Line Lensing Survey and the Sloan Lens ACS Survey. We scanned the co-added residuals that we constructed from stacks of foreground subtracted row-stacked-spectra so a sigma-clipping method can be used to reject cosmic rays and other forms of transients that impact only a small fraction of the combined exposures. We also constructed narrow-band images from the signal to noise of the co-added residuals to observe signs of lensed source images. We also use several methods to compute the probable strong lensing regime for each candidate lens to determine which candidate background galaxies may reside sufficiently near the galaxy centre for strong lensing to occur. We present the spectroscopic redshifts within a value-added catalogue (VAC) for data release 17 (DR17) of SDSS-IV. We also present the lens candidates, spectroscopic data, and narrow-band images within a VAC for DR17. High resolution follow-up imaging of these lens candidates are expected to yield a sample of confirmed grade-A lenses with sufficient angular size to probe possible discrepancies between the mass derived from a best-fitting lens model, and the dynamical mass derived from the observed stellar velocities.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental decoy-state Bennett-Brassard 1984 quantum key distribution through a turbulent channel

In free-space quantum key distribution (QKD) in turbulent conditions, scattering and beam wandering cause intensity fluctuations which decrease the detected signal-to-noise ratio. This effect can be mitigated by rejecting received bits when the channel's transmittance is below a threshold. Thus, the overall error rate is reduced and the secure key rate increases despite the deletion of bits. In this work, we implement recently proposed selection methods focusing on the prefixed-threshold real-time selection (P-RTS) where a cutoff can be chosen prior to data collection and independently of the transmittance distribution. We perform finite-size decoy-state Bennett-Brassard 1984 QKD in a laboratory setting where we simulate the atmospheric turbulence using an acousto-optical modulator. We show that P-RTS can yield considerably higher secure key rates for a wide range of the atmospheric channel parameters. In addition, we evaluate the performance of the P-RTS method for a realistically finite sample size. We demonstrate that a near-optimal selection threshold can be predetermined even with imperfect knowledge of the channel transmittance distribution parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DeepShadows: Separating low surface brightness galaxies from artifacts using deep learning

Searches for low-surface-brightness galaxies (LSBGs) in galaxy surveys are plagued by the presence of a large number of artifacts (e.g., objects blended in the diffuse light from stars and galaxies, Galactic cirrus, star-forming regions in the arms of spiral galaxies, etc.) that have to be rejected through time consuming visual inspection. In future surveys, which are expected to collect hundreds of petabytes of data and detect billions of objects, such an approach will not be feasible. We investigate the use of convolutional neural networks (CNNs) for the problem of separating LSBGs from artifacts in survey images. We take advantage of the fact that we have available a large number of labeled LSBGs and artifacts from the Dark Energy Survey, that we use to train, validate, and test a CNN model. That model, which we call DeepShadows , achieves a test accuracy of 92.0%, a significant improvement relative to feature-based machine learning models. We also study the ability to use transfer learning to adapt this model to classify objects from the deeper Hyper-Suprime-Cam survey, and we show that after the model is retrained on a very small sample from the new survey, it can reach an accuracy of 87.6%. Finally, these results demonstrate that CNNs offer a very promising path in the quest to study the low-surface-brightness universe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing aluminum oxide passivation layers—Laser-induced plasmas for layer formation, real-time diagnostics, and layer evaluation

Molten salts have beneficial thermophysical and electrolytic properties, but the aggressive nature of molten salts requires corrosion mitigation strategies, such as structural material surface treatment. In this study, a laser-induced breakdown spectroscopy (LIBS) system was used to simultaneously ablate and monitor de-excitation spectra to form and identify dense alumina passivation layers. Additionally, high-frequency (kHz) LIBS imaging allowed rapid elemental mapping and depth profiling for surface O/Al ratios via minimally destructive analysis. The paired t-test rejected the null hypothesis that air and Ar cover gases were equivalent (p = 0.00012), and the analysis of variance (ANOVA) showed that overlap between shots (p = 0.03112) and cover gas flow rate (p = 0.02729) were statistically significant. At 75% overlap, the O/Al ratio increased to 10% ± 2%, and 90% overlap rose further to 31% ± 2%. Regardless of overlap, tuning the gas flow from 0.5 to 2.5 L min −1 enhanced the O/Al ratio by 24% ± 4%. LIBS depth profiling showed a 3× increase in layer thickness from 75% to 90% overlap. Molecular band peaks of AlO, a precursor to Al 2 O 3 found during treatment, suggest that band intensity could be used for real-time Al 2 O 3 optimization. Ultimately, by adjusting laser spot overlap and cover gas flow rate, a 266 nm laser was shown to form Al 2 O 3 layers on an Al6061 sample, with cover gas flow rate primarily affecting the O/Al ratio and layer thickness correlating with laser spot overlap. This combination of molecular spectra collection, imaging, and depth profiling demonstrated the robust layer analysis capabilities of LIBS.

Corrosion↗

Initial Efforts Organizing WPNCS SG-8: Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks

The Working Party on Nuclear Criticality Safety (WPNCS) under the guidance of the Organization for Economic Co-operation and Development (OECD) Nuclear Energy Agency (NEA) has over 20 years of experience addressing concerns related to static and transient configurations encountered within the nuclear fuel cycle: fuel fabrication, transportation, reprocessing, storage, and geological disposal. One of the cornerstone activities of the WPNCS is the International Criticality Safety Benchmark Evaluation Project (ICSBEP), which was established to identify a comprehensive set of criticality benchmark data, evaluate the data, including quantification of overall uncertainties; compile the data into a standardized format, perform sample calculations utilizing modern nuclear data sets and codes utilized in nuclear criticality safety, and formally document the work into a single source of verified benchmark data. Annually, members of the ICSBEP Technical Review Group (TRG) contribute evaluated benchmark data that undergoes comprehensive technical review prior to publication in the ICSBEP Handbook. In the years since the ICSBEP was established, there has been much work to prepare benchmark data to support validation activities in nuclear criticality safety. The 2020 edition of the ICSBEP Handbook contains acceptable benchmark specifications for 5,053 critical, subcritical, or near-critical configurations in 582 benchmark evaluations. Modern benchmark development benefits from decades of experienced international participants, a well-established handbook format, supplementary guides to deal with uncertainty quantification, and a comprehensive review process based upon independent reviews from international experts. The ICSBEP Handbook also contains 838 configurations deemed unacceptable to support criticality safety efforts. They are recorded, with the reasoning for their rejection, to preserve the experimental data, prevent reevaluation of data that are incomplete or contain known errors, and/or to potentially allow future reevaluation of the experiment pending the identification of sufficient data to resolve identified inconsistencies and errors. Users of the ICSBEP Handbook today might notice that the rigor and quality of modern criticality safety benchmarks is much greater than those prepared within the initial decade of the project. Benchmarks with 1s uncertainties in k eff greater than 1% were traditionally rejected unless they were identified as unique experiment types that encompassed materials, fuels, or designs not available from other benchmark experiments. However, benchmarks developed using modern experimental techniques and practices typically have uncertainties on the order of a few tenths of a percent. There have been ongoing efforts to improve the overall quality of previously published benchmark evaluations. Seventy-eight evaluations, containing approximately 600 configurations, have been revised just within the past decade. An additional eleven benchmarks are under revision for updated release in the 2020 edition of the ICSBEP Handbook. If some of the historic benchmarks were resubmitted in their current form to the TRG today, they would be rejected due to lack of data, missing components in the uncertainty analysis, or incomplete benchmark model development. The use of historic criticality safety benchmarks that underestimate the total uncertainty, lack properly quantified biases, or provide inadequate benchmark specifications do not sufficiently support modern criticality safety and nuclear data efforts. Although the ICSBEP Handbook is recognized by regulating bodies to support criticality safety, users are required to justify their reasons to ignore historic benchmark data and include additional safety margins within their designs. Discussions were held at the WPNCS 23rd Annual Meeting in September 2019 regarding the aforementioned issues. The resultant decision was to establish Subgroup 8 (SG-8): Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks. The current activities of SG-8 are discussed herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Anatomy of a mega‐radiation: Biogeography and niche evolution in Astragalus

Premise Astragalus (Fabaceae), with more than 3000 species, represents a globally successful radiation of morphologically highly similar species predominant across the northern hemisphere. It has attracted attention from systematists and biogeographers, who have asked what factors might be behind the extraordinary diversity of this important arid-adapted clade and what sets it apart from close relatives with far less species richness. Methods Here, for the first time using extensive phylogenetic sampling, we asked whether (1) Astragalus is uniquely characterized by bursts of radiation or whether diversification instead is uniform and no different from closely related taxa. Then we tested whether the species diversity of Astragalus is attributable specifically to its predilection for (2) cold and arid habitats, (3) particular soils, or to (4) chromosome evolution. Finally, we tested (5) whether Astragalus originated in central Asia as proposed and (6) whether niche evolutionary shifts were subsequently associated with the colonization of other continents. Results Our results point to the importance of heterogeneity in the diversification of Astragalus, with upshifts associated with the earliest divergences but not strongly tied to any abiotic factor or biogeographic regionalization tested here. The only potential correlate with diversification we identified was chromosome number. Biogeographic shifts have a strong association with the abiotic environment and highlight the importance of central Asia as a biogeographic gateway. Conclusions Our investigation shows the importance of phylogenetic and evolutionary studies of logistically challenging “mega-radiations.” Our findings reject any simple key innovation behind high diversity and underline the often nuanced, multifactorial processes leading to species-rich clades.

59 BASIC BIOLOGICAL SCIENCES↗

To have value, comparisons of high-throughput phenotyping methods need statistical tests of bias and variance

The gap between genomics and phenomics is narrowing. The rate at which it is narrowing, however, is being slowed by improper statistical comparison of methods. Quantification using Pearson’s correlation coefficient ( r ) is commonly used to assess method quality, but it is an often misleading statistic for this purpose as it is unable to provide information about the relative quality of two methods. Using r can both erroneously discount methods that are inherently more precise and validate methods that are less accurate. These errors occur because of logical flaws inherent in the use of r when comparing methods, not as a problem of limited sample size or the unavoidable possibility of a type I error. A popular alternative to using r is to measure the limits of agreement (LOA). However both r and LOA fail to identify which instrument is more or less variable than the other and can lead to incorrect conclusions about method quality. An alternative approach, comparing variances of methods, requires repeated measurements of the same subject, but avoids incorrect conclusions. Variance comparison is arguably the most important component of method validation and, thus, when repeated measurements are possible, variance comparison provides considerable value to these studies. Statistical tests to compare variances presented here are well established, easy to interpret and ubiquitously available. The widespread use of r has potentially led to numerous incorrect conclusions about method quality, hampering development, and the approach described here would be useful to advance high throughput phenotyping methods but can also extend into any branch of science. The adoption of the statistical techniques outlined in this paper will help speed the adoption of new high throughput phenotyping techniques by indicating when one should reject a new method, outright replace an old method or conditionally use a new method.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental and Phenomenological Investigations of the MiniBooNE Anomaly

This thesis covers a range of experimental and theoretical efforts to elucidate the origin of the $4.8\sigma$ MiniBooNE low energy excess (LEE). We begin with the follow-up MicroBooNE experiment, which took data along the BNB from 2016 to 2021. This thesis specifically presents MicroBooNE's search for $\nu_e$ charged-current quasi-elastic (CCQE) interactions consistent with two-body scattering. The two-body CCQE analysis uses a novel reconstruction process, including a number of deep-learning-based algorithms, to isolate a sample of $\nu_e$ CCQE interaction candidates with $75\%$ purity. The analysis rules out an entirely $\nu_e$-based explanation of the MiniBooNE excess at the $2.4\sigma$ confidence level. We next perform a combined fit of MicroBooNE and MiniBooNE data to the popular $3+1$ model; even after the MicroBooNE results, allowed regions in $\Delta m^2$-$\sin^2 2_{\theta_{\mu e}}$ parameter space exist at the $3\sigma$ confidence level. This thesis also demonstrates that the MicroBooNE data are consistent with a $\overline{\nu}_e$-based explanation of the MiniBooNE LEE at the $<2\sigma$ confidence level. Next, we investigate a phenomenological explanation of the MiniBooNE excess combining the $3+1$ model with a dipole-coupled heavy neutral lepton (HNL). It is shown that a 500 MeV HNL can accommodate the energy and angular distributions of the LEE at the $2\sigma$ confidence level while avoiding stringent constraints derived from MINER$\nu$A elastic scattering data. Finally, we discuss the Coherent CAPTAIN-Mills experiment--a 10-ton light-based liquid argon detector at Los Alamos National Laboratory. The background rejection achieved from a novel Cherenkov-based reconstruction algorithm will enable world-leading sensitivity to a number of beyond-the-Standard Model physics scenarios, including dipole-coupled HNLs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ATOMIC Simulations and Experimental Data for Basalt-like Compounds

This data consists of simulations and experimental measurements of laser-induced breakdown spectroscopy (LIBS). The simulations are produced by ATOMIC, a general purpose plasma modeling and kinetics code that has been designed to compute emission (or absorption) spectra from plasmas [2]. The makeup of the plasma was considered to be divided into some proportion water, some proportion Martian atmosphere (CO2), and some proportion target (from the rock or object impacted by the laser), where these proportions add to 1. Based on expert knowledge, the proportion of water was kept in the range [0.0,0.5] and the proportion of atmosphere was kept in the range [0.02, 0.9]. Our overall suite of simulations contains six sets of simulations that differ in which elements were considered to make up the target. Within each set, we used uniformly drawn temperatures and log mass densities within pre-specified ranges. The temperature range was [0.5,1.5] eV and the log (base 10) mass density range was [-7,-4]. The proportion of water, atmosphere, and target were drawn from a symmetric Dirichlet distribution, but draws in which the propor- tion of water or atmosphere exceeded the pre-specified limits were rejected from the design. Up to eleven constituent elements (Si, Al, Fe, Mg, Ca, O, Ti, Mn, Na, K, P) were considered for the target, as they are the most common elements found in basalt compounds and were used in [1]. For each run, the proportions of the constituent elements making up the target were drawn from a symmetric Dirichlet distribution. We ran 1,350 simulations that included nonzero proportions of all eleven elements. We also ran simulations which excluded some of these elements. In particular, we ran 1,000 simulations that only included nonzero proportions for the six most common elements (Si, Al, Fe, Mg, Ca, O). We also ran five sets, each with 500 simulations, that only included nonzero proportions for five of the six most common elements (but where all sets included O). Thus, we generated a total of 4,850 spectra representing basalt-like compounds in which the target was comprised of oxygen and between four and ten other elements. The ATOMIC code produced spectra over a range of 240nm - 880nm that roughly mimics the range collected by the ChemCam instrument on the Mars rover Curiosity. Each spectra had 32,000 wavelengths split across three spectrometer ranges (to mimic ChemCam). The experimental data, described in [1], measures a prepared basalt sample. All files are kept in directories whose names indicate the set of elements considered for the target with file names numbered to indicate the line in the design files used to produce the simulation. The designs are provided as text files with names indicating their purpose. The experimental data is provided as a CSV file which contains a header with measurement information, followed by a collection of 50 shots across a collection of wavelengths, along with the computed median and mean across shots.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗