Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “regenerating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Ceramic regenerator systems development program

Ceramic regenerator cores are considered that can be used in passenger car gas turbine engines, Stirling engines, and industrial/truck gas turbine engines. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability tests/in industrial gas turbine engines. A regenerator core made from aluminum silicate shows minimal evidence of chemical attack damage after 7804 hours of engine test at 800 C and another showed little distress after 4983 hours at 982 C. The results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are also included.

Cook, J. A.↗

Argon/UF6 plasma experiments: UF6 regeneration and product analysis

An experimental and analytical investigation was conducted to aid in developing some of the technology necessary for designing a self-critical fissioning uranium plasma core reactors (PCR). This technology is applicable to gaseous uranium hexafluoride nuclear-pumped laser systems. The principal equipment used included 1.2 MW RF induction heater, a d.c. plasma torch, a uranium tetrafluoride feeder system, and batch-type fluorine/UF6 regeneration systems. Overall objectives were to continue to develop and test materials and handling techniques suitable for use with high-temperature, high-pressure, gaseous UF6; and to continue development of complementary diagnostic instrumentation and measurement techniques to characterize the effluent exhaust gases and residue deposited on the test chamber and exhaust system components. Specific objectives include: a development of a batch-type UF6 regeneration system employing pure high-temperature fluorine; development of a ruggedized time-of-flight mass spectrometer and associated data acquisition system capable of making on-line concentration measurements of the volatile effluent exhaust gas species in a high RF environment and corrosive environment of UF6 and related halide compounds.

Roman, W. C.↗

Evaluation of ceramic packed-rod regenerator matrices

An extensive evaluation of a modified cryocooler with various regenerator matrices is reported. The matrices examined are 0.015 in. diam. Pb spheres and 0.008, 0.015, and 0.030 in. diam. rods of a 0.2% SnCl2 doped ceramic labelled LS-8A. Specific heat and thermal conductivity data on these rod materials are also reported. The chronic pulverization/dusting problem common to Pb spheres was investigated. During a 1000 hr life test with 0.0008 in. diam. rods there was no degradation of the refrigerator performance, and a subsequent examination of the rods themselves revealed no evidence of breakage or pulverization. The load temperature characteristics for the rod packed regenerators were inferior to that for the Pb spheres, the effect being to shift the Pb spheres load curve up in temperature. This temperature shift was 5.0, 7.4, and 11.6K for the 0.0008, 0.015, and 0.030 in. diam. rods, respectively.

Lawless, W. N.↗

Unconventional processes for food regeneration in space - An overview

Alternatives to conventional plant agriculture for the regeneration of food during space missions of extended duration are examined. The options considered, which may be used in combination with conventional agriculture, include the production of food from plant wastes, the chemical synthesis of food from carbon dioxide and other simple molecules or the substitution of edible chemicals, and the use of microrganisms for food and oxygen regeneration, with suitable processing. A comparison of solar energy conversion efficiencies is presented for nonphotosynthetic bacteria grown on hydrogen and algal systems photosynthetically, and it is shown that hydrogen bacteria are potentially more attractive than photosynthetic algae using artificial light. Weight-volume requirements for the conventional plant, algae and hydrogen bacteria systems are also compared to demonstrate the advantages of microbial systems.

Stokes, B. O.↗

Regenerable non-venting thermal control subsystem for extravehicular activity

Extravehicular Mobility Unit heat rejection requirements have been formulated for both Space Shuttle Orbiter and space station regenerable nonventing thermal sink (RNTS) applications, where the former involve nonventing extravehicular activity (EVA) missions and the latter both nonventing and regenerable EVA. The present conceptual study notes that while the exclusive use of thermal storage is suitable for the Space Shuttle mission, space station requirements are best satisfied by a hybrid system which combines thermal storage with radiator and heat pump. The Space Shuttle RNTS thermal control subsystem's thermal storage unit uses water as a phase change medium. It is noted that the same heat storage unit can satisfy the Space Shuttle and space station requirements.

Roebelen, G. J., Jr.↗

Fatigue failure of regenerator screens in a high frequency Stirling engine

Failure of Stirling Space Power Demonstrator Engine (SPDE) regenerator screens was investigated. After several hours of operation the SPDE was shut down for inspection and on removing the regenator screens, debris of unknown origin was discovered along with considerable cracking of the screens in localized areas. Metallurgical analysis of the debris determined it to be cracked-off-deformed pieces of the 41 micron thickness Type 304 stainless steel wire screen. Scanning electron microscopy of the cracked screens revealed failures occurring at wire crossovers and fatigue striations on the fracture surface of the wires. Thus, the screen failure can be characterized as a fatigue failure of the wires. The crossovers were determined to contain 30 percent reduction in wire thickness and a highly worked microstructure occurring from the manufacturing process of the wire screens. Later it was found that reduction in wire thickness occurred because the screen fabricator had subjected it to a light cold-roll process after weaving. Installation of this screen left a clearance in the regenerator allowing the screens to move. The combined effects of the reduction in wire thickness, stress concentration (caused by screen movement), and highly worked microstructure at the wire crossovers led to the fatigue failure of the screens.

Hull, David R.↗

Development of a regenerable humidity and CO2 control system for an advanced EMU

A 5-h-regenerable nonventing humidity and CO2 control subsystem (HCCS) technology demonstration unit is being developed for potential use in an Advanced Extravehicular Mobility Unit for Space Station application. The HCCS incorporates a weak-base-anion exchange resin packed in a metal-foam-matrix heat exchanger. This system simultaneously removes CO2 and water vapor, with the resulting exothermic heat of reaction rejected to the heat exchanger. The system has no moving parts, resulting in a highly reliable simple configuration. Regeneration may be accomplished via internal heating and vacuum.

Nalette, Timothy A.↗

Electrochemically regenerable metabolic CO2 and moisture control system for an advanced EMU application

Regenerable CO2 and moisture removal techniques that reduce expendables and logistics requirements are needed to sustain people undertaking extravehicular activities for the Space Station. NASA has been investigating ways to advance the Electrochemically Regenerable CO2 and Moisture Absorption (ERCA) technology to replace the nonregenerable solid lithium hydroxide absorber for the advanced Portable Life Support System (PLSS). The ERCA technology, due to its use of liquid absorbent, has the ability to effectively satisfy the high metabolic CO2 and moisture removal requirements of PLSS applications. This paper defines the ERCA technology concept and its advantages for the PLSS application, reviews breadboard and subscale testdata and presents the results of design concepts for a prototype Absorber Module of improved performance and the physical characteristics of the projected flight hardware.

Lee, M. C.↗

Metal oxide regenerable carbon dioxide removal system for an advanced portable life support system

The development of a CO2 removal system for an astronaut portable life support system to meet the EVA requirements for the Space Station is discussed, focusing on the factors important in the selection of the metal oxide absorbent for CO2 removal. Results from laboratory tests on metal oxide absorbent materials are given, including characterization studies and dynamic CO2 uptake and regeneration measurements. The preliminary design of the breadboard system to perform both the absorption and regeneration functions is presented.

Nacheff, Maurena S.↗

Modeling 2-D jets impinging on Stirling regenerators

The extent to which flow leaving Stirling coolers or heaters in the form of high-velocity jets penetrate the regenerator matrix is visually modeled using a computer program. Two-dimensional laminar jets are shown impinging on regenerator samples of variable permeability ranging from no matrix at all to matrices dense enough to stop the jet dead on. The results lend credibility to a simple tension for flow uniformity as a function of penetration depth.

Gedeon, David↗

Development of a regenerable metal oxide CO removal system

A regenerable metal oxide carbon dioxide (CO2) removal system was developed to replace the current means of a nonreusable chemical, lithium hydroxide, for removing the metabolic CO2 of an astronaut in a space suit. Testing indicates that a viable low-volume metal oxide concept can be used in the portable life support system for CO2 removal during Space Station extravehicular activity (EVA). A canister of nearly the same volume as that used for the Space Shuttle, containing 0.10 cu ft of silver-oxide-based pellets, was tested; test data analysis indicates that 0.18 cu ft of the metal oxide will result in an 8-hour EVA capability. The testing suggests that the metal oxide technology offers a low-volume approach for a reusable CO2 removal concept applicable for at least 40 EVA missions. The development and testing of the breadboard regeneration package is also described.

Cusick, Robert J.↗

Sorption Compressor With Rotary Regenerator

Proposed two-stage sorption compressor for cryogenic system features rotary regenerator. At each stage, rotor interacts with stator to provide quadruple regeneration. Contains no valves, and only moving part is rotor, which turns very slowly. Features include less required power and greater reliability.

Jones, Jack A.↗

In vitro regeneration of Basella alba L

Basella alba L. is a tropical vine used as a vegetable in some Asian and African countries. It has potential as a nontraditional crop for small family farms. A short day plant, it blooms during the fall, provided the temperatures are mild. In the southeastern U.S., the short days of fall are associated with subfreezing temperatures, and plants are killed before blooming. Attempts were made to regenerate the plant using tissue culture techniques. Several trials were conducted with different media, hormones, and explants. It was found that nodal segments on Gamborg medium regenerated shoots. Interaction studies of auxins and cytokinins indicated that its endogeneous auxin content might be high because callus proliferated in almost all treatments and roots initiated even when the medium was not supplemented with an auxin.

Edney, Norris Allen↗

Regenerator performance with sinusoidal flow

The ineffectiveness of regenerators with sinusoidal laminar flow through parallel plate, screen, and packed sphere matrices is evaluated in the limit of infinite matrix heat capacity. Increases in ineffectiveness of up to 23 percent over the constant flow values result for parallel plate regenerators.

Daney, D. E.↗

Oscillating-flow regenerator test rig: Woven screen and metal felt results

We present correlating expressions, in terms of Reynolds or Peclet numbers, for friction factors, Nusselt numbers, enhanced axial conduction ratios, and overall heat flux ratios in four porous regenerator samples representative of stirling cycle regenerators: two woven screen samples and two random wire samples. Error estimates and comparison of data with others suggest our correlations are reliable, but we need to test more samples over a range of porosities before our results will become generally useful.

Gedeon, D.↗

An apparatus for the measurement of regenerator performance in pulse tube refrigerators

This paper discusses the design and construction of an apparatus to measure the ineffectiveness of regenerators used for pulse tube refrigerators. Because of the fairly large mass flow rates which occur in pulse tube refrigerators, the regenerator ineffectiveness must be made quite small. The apparatus described here allows for the measurement of the refrigerator. A low temperature heat sink of liquid nitrogen is used since it approximates the temperatures normally achieved in a one-stage pulse tube.

Rawlins, Wayne↗

Airborne trace organic contaminant removal using thermally regenerable multi-media layered sorbents

A cyclic two-step process is described which forms the basis for a simple and highly efficient air purification technology. Low molecular weight organic vapors are removed from contaminated airstreams by passage through an optimized sequence of sorbent media layers. The contaminant loaded sorbents are subsequently regenerated by thermal desorption into a low volume inert gas environment. A mixture of airborne organic contaminants consisting of acetone, 2-butanone, ethyl acetate, Freon-113 and methyl chloroform has been quantitatively removed from breathing quality air using this technique. The airborne concentrations of all contaminants have been reduced from initial Spacecraft Maximum Allowable Concentration (SMAC) levels to below the analytical limits of detection. No change in sorption efficiency was observed through multiple cycles of contaminant loading and sorbent regeneration via thermal desorption.

Atwater, James E.↗

Pulsed single-blow regenerator testing

A pulsed single-blow method has been developed for testing of Stirling regenerator materials performance. The method uses a tubular flow arrangement with a steady gas flow passing through a regenerator matrix sample that packs the flow channel for a short distance. A wire grid heater spanning the gas flow channel is used to heat a plug of gas by approximately 2 K for approximately 350 ms. Foil thermocouples monitor the gas temperature entering and leaving the sample. Data analysis based on a 1D incompressible-flow thermal model allows the extraction of Stanton number. A figure of merit involving heat transfer and pressure drop is used to present results for steel screens and steel felt. The observations show a lower figure of merit for the materials tested than is expected based on correlations obtained by other methods.

Oldson, J. C.↗