Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reactive power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Creation of Synthetic Electric Grids (SPP/MISO) Supporting PERFORM (Final Report)

Over the course of the project, two “realistic but not real” synthetic transmission-level grid models over the SPP-MISO and ERCOT footprints were created to provide more realistic data and increase the reliability and resiliency of the grids under a variety of scenarios. The synthetic ERCOT transmission grid is compatible with the distribution grid developed in collaboration with NREL. All generators are based on the EIA 860 data and a column with EIA plant code and Gen ID is added to generators of both grids so that they can be easily mapped. The improvements are also made to electric grids including N-1 contingencies with some remedial actions, improving the transmission lines to avoid lines in lakes, including an HVDC line to the SPP-MISO case, providing several generator parameters and their temporal constraints that were not included in EIA 860 form, generators’ cost curves, load offer curves, adding phase shifters and tap changers with impedance correction tables, adding reactive power control and partitioning the grids into active and reactive reserve zones and determine different types of the required reserve for each zone. Hourly load time series at the bus level were generated to create scenarios for solving power flow in different loading conditions. Weather measurement information and the models of renewable generators are used to directly include the impact of weather on the grids. Based on a variety of load and weather conditions the grids are improved to accommodate different conditions. The ERCOT 7k-bus grids were also modeled for the year 2030 with predicted improvements in renewable resources. The renewable generation model was also improved with historic weather data included. The impact of electric vehicles on the ERCOT grid is also modeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control circuit maintains unity power factor of reactive load

Circuit including feedback control elements automatically corrects the power factor of a reactive load. It maintains power supply efficiency where negative load reactance changes and varies by providing corrective error signals to the control windings of a power supply transformer.

Kramer, M.↗

Alternating Direction Decomposition with Strong Bounding and Convexification (ADDSBC) for Solving Security Constrained AC Unit Commitment Problems

This project aims to develop efficient and robust computational methods for solving the security-constrained unit commitment and alternating current optimal power flow problem (SC-UC-ACOPF). The SC-UC-ACOPF problem is at the center of the short-term operation of the U.S. Power Grid. It is solved every week, every day, and every 10 minutes to plan for the optimal action of electricity generation and consumption by minimizing the generation cost and maintaining power system reliability against potential disruptions of equipment failures. In mathematical terms, SC-UC-ACOPF is a challenging large-scale mixed-integer nonlinear optimization model. This means that the decisions involve both discrete variables, e.g. the turning on and off of generators and switching of transmission lines and transformers, and continuous decisions, e.g. the amount of energy generated by each generator and the power flows in the power grid. The physics of the power flow is described by nonlinear equations involving real and reactive power and bus voltages. Another key feature is the large number of contingencies, i.e. the system needs to stay reliable in face of failure of any one equipment, such as transmission lines and generators. The U.S. power grids are extremely complicated and large scale with more than 5,000 generators, 50,000 buses, and 100,000 high-voltage transmission lines, making the SC-UC-ACOPF a very large-scale computation challenge. The research developed in this project aims to solve the SC-UC-ACOPF problems in the three timescales, i.e. weekly, daily, and every 10-min. The proposed computational methods are built on a principled algorithmic approach of decomposition and penalization. More specifically, the algorithm develops spatial and temporal decomposition by exploiting the strong temporal coupling and weak spatial coupling of the UC problem and the complementary feature, i.e. weak temporal coupling and strong spatial coupling of the ACOPF problem. The algorithm also leverages recent progresses in strong convex relaxation of ACOPF. A unique feature of the proposed approach is that it generates a valid, global upper bound on the optimal maximum profit. In this way, a global optimality gap is available to measure the quality of the solution. To further speed up computation, the research team has developed a plethora of effective heuristics to strengthen the iterative penalty-based decomposition framework. For instance, a heuristic is developed to construct inner approximations of the time coupling constraints within the time decoupled problems. Contingencies are pre-screened and low-rank matrix computation is exploited to find the almost unique solution to each contingency. A novel heuristic for line switching is proposed and tested with positive impacts on instances where line switching is beneficial. Taking a systematic approach and carefully handling every detail of the problem pays off. The TIM-GO’s performance throughout the trials and the final event was stellar. TIM-GO garnered the second highest total prize money and is ranked in the top three positions across all categories of comparison.

97 MATHEMATICS AND COMPUTING↗

Linearized Distribution Optimal Power Flow for OEDI SI

This research is to meant to demonstrate the OEDI SI use case for distributed optimal power flow (DOPF). The goal was to formulate the optimal power flow problem in the distribution system for active and reactive power setpoints of PV systems using topology information and voltage measurements. The co-simulation runs every 15 minutes as outlined within the scenario file for the given feeder configuration. The linked GitHub repository includes five federates to achieve DOPF for the small, medium, large, and IEEE 123 feeder scenarios. We are using the OEDI SI framework, as well as the example feeder, sensor, recorder, and estimator federates provided in the example repository for OEDI SI. We also provide a runner script for switching between scenarios.

algorithm↗

Digital Real-Time Simulation and Power Quality Analysis of a Hydrogen-Generating Nuclear-Renewable Integrated Energy System

This paper investigates the challenges and solutions associated with integrating a hydrogen-generating nuclear-renewable integrated energy system (NR-IES) under a transactive energy framework. The proposed system directs excess nuclear power to hydrogen production during periods of low grid demand while utilizing renewables to maintain grid stability. Using digital real-time simulation (DRTS) in the Typhoon HIL 404 model, the dynamic interactions between nuclear power plants, electrolyzers, and power grids are analyzed to mitigate issues such as harmonic distortion, power quality degradation, and low power factor caused by large non-linear loads. A three-phase power conversion system is modeled using the Typhoon HIL 404 model and includes a generator, a variable load, an electrolyzer, and power filters. Active harmonic filters (AHFs) and hybrid active power filters (HAPFs) are implemented to address harmonic mitigation and reactive power compensation. The results reveal that the HAPF topology effectively balances cost efficiency and performance and significantly reduces active filter current requirements compared to AHF-only systems. During maximum electrolyzer operation at 4 MW, the grid frequency dropped below 59.3 Hz without filtering; however, the implementation of power filters successfully restored the frequency to 59.9 Hz, demonstrating its effectiveness in maintaining grid stability. Future work will focus on integrating a deep reinforcement learning (DRL) framework with real-time simulation and optimizing real-time power dispatch, thus enabling a scalable, efficient NR-IES for sustainable energy markets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation: Preprint

Existing real-world projects of GFM inverters that operate in parallel to power grids typically are sized between dozens and a few hundreds Megawatt (MW) scale according to a recent NERC GFM inverter white paper. These large systems are often difficult to evaluate prior to deployments because of their large size. The performance of smaller GFM inverters (dozens to a few hundreds MW) that operate parallel with power grids (distribution systems) is even less understood. There is an opportunity to better understand these systems through hardware testing under controlled laboratory conditions. Therefore, this paper presents the functional performance evaluation tests of multiple (three) commercial GFM inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore the GFM inverters' functionalities and dynamic response when in parallel with power grids to eventually develop universal specifications for GFM inverters. Both steady state (changing the inverter's frequency and voltage droop) and transient (adding step change in grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The experimental results indicate the bench-marked performance that: 1) the GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power when paralleled to the grid; 2) the GFM inverters automatically respond to system frequency and voltage events to output the needed power, however, the GFM inverters all show stability issues when absorbing reactive power from the grid.

grid-forming inverters↗

Topology-Aware Reinforcement Learning for Voltage Control: Centralized and Decentralized Strategies

Volt-VAR control (VVC) methods based on deep reinforcement learning (DRL) can effectively control distribution grid voltage and minimize power loss by implementing corrective and preventive control measures on the reactive power output of inverter-based distributed energy resources (DERs). However, model-free DRL-based VVC approaches usually cannot capture the important topological feature of the power system since they use a fully-connected network (FCN) to deliver the action. Therefore, this paper proposes a graph convolutional network (GCN)-based DRL approach that can employ the topological information of the network to take better control action for regulating the voltage. Our implementation allows for both centralized and decentralized configurations, utilizing a single agent and multiple agents respectively. Although the centralized GCN-based DRL approach has its advantages of minimizing voltage fluctuation and power loss, it is not suitable for large scale power systems due to its challenges in terms of scalability, computation speed and potential single points of failure. Therefore, these problems can be resolved using the decentralized GCN-based DRL approach. Moreover, to ensure the safe operation of the model, our proposed approach incorporates an exponential barrier function while formulating the reward function for each agent. To validate performance of the proposed approaches, the proposed model is tested on modified IEEE test systems and the performances are measured in terms on voltage fluctuation reduction, minimization of power loss and computational speed. Finally, the results show that the proposed topology-aware approach outperforms the FCN-based DRL approach in terms of reducing voltage fluctuation and minimizing power loss of the network. Moreover, it is shown that the decentralized GCN-based DRL has faster computational speed than other approaches.

42 ENGINEERING↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation

This paper presents the functional performance evaluation tests of multiple (three) commercial grid-forming (GFM) inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore and benchmark the GFM inverters' functionalities and dynamic response when they are operated in parallel with power grids. Both steady-state (changing the inverter's frequency and voltage droop) and transient (adding step changes to grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; and 1) the GFM inverters automatically respond to system frequency and voltage events to output the needed power; 3) all the GFM inviters shows stability issues when absorbing reactive power from the grid.

frequency droop↗

Identification of a Delay Attack in the Secondary Control of Grid-Tied Inverter Systems

This work is developed for the identification of a denial-of-service cyberattack on the secondary controller of inverter systems which is connected to the power grid. The identification is made through the dynamic response of the reactive power (Q) of the system under attack. By observing the dynamic characteristic of Q, it is possible to correlate the attack with the nominal response of the hierarchical controller. The article shows that the occurrence of the attack can be identified through a supervisory control that runs a model in parallel. The article argues that after an early identification of the attack, a local controller can take action to mitigate its effects on the system’s response.

Roig Greidanus, Mateo D.↗

Modular, Multifunction, Multiport and Medium Voltage Utility Scale SiC PV Inverter (Final Report)

This project is to develop and demonstrate a Modular, Multi-function, Multiport and Medium Voltage utility scale SiC solar inverter (M4 Inverter). The M4 Inverter is a next generation utility scale PV + storage inverter that can substantially reduce the levelized cost of energy (LCOE) while providing grid friendly ancillary services. Conventional utility scale solar inverters includes three parts, a megawatt rated solar inverter, a low frequency transformer (LFT) and a medium voltage switch gear. The proposed M4 Inverter directly converts the DC output of solar panels to medium voltage AC, eliminating the bulky and costly LFT. The M4 Inverter also has a DC port to interface with an additional energy storage device. This plus its bidirectional power flow capability, allows multiple functions in addition to PV maximum power tracking be achieved. These additional functionalities include but not limited to reactive power support, peak shaving, fast frequency regulation and synthetic inertia. Predicted LCOE reductions with these added functionalities, improved efficiency and longer lifetime time are more than 30% compared with the 2017 utility scale solar LCOE. A 1MVA SiC M4 Inverter was developed and tested at high power level. The project has also advanced the state of the art in controller hardware in the loop simulation capability. Power electronic innovations introduced in the M4 Inverter includes 1700V SiC MOSFET application in 1500V PV system, soft switching three-port power converters and modular converter architecture.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupled neutronic-thermal-hydraulic simulations of the European SFR core

Within the European SFR (Sodium-cooled Fast Reactor) - Safety Measures Assessment and Research Tools (ESFR-SMART) project, steady-state coupled simulation of the ESFR core has been performed using several core analysis packages, with the objective of quantifying the coupling effect. Focus is on the fuel Doppler effect and coolant expansion effect. Standalone neutronics calculations in TRACE/PARCS (PSI), DYN3D (HZDR) and WIMS (Jacobs) showed superb agreement with the reference Serpent power distribution (root mean square - rms discrepancies of 1.3%, 1.5% and 0.7% respectively). Results for COUNTHER (CIEMAT) were also in reasonable agreement, but with a somewhat higher discrepancy of 3.7%. Temperature distributions from thermal-hydraulic calculations were also compared and are found to be in good agreement. The effect of Doppler and coolant density feedback on core power distribution was predicted by TRACE/PARCS, DYN3D and WIMS to be between 0.4% and 0.8% rms difference in assembly powers. Reactivity coefficients for perturbations in the inlet temperature, flow rate and core power were shown to be negative for these three codes, with values of roughly -0.5 pcm/C. degree, -0.3 pcm/C. degree and -3.5 pcm/C. degree respectively. A preliminary investigation of differential thermal expansion effects indicates that this may have a significant effect on core power distribution of a few %, greater than anticipated a priori and may warrant inclusion in coupled core analysis to ensure the accurate calculation of power distributions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support

This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller's effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimized Dispatch of Distributed Energy Resources for Resiliency and Power Quality Improvements at the Grid-Edge

Distributed Energy Resources (DERs) installed on low-voltage distribution systems, both utility-owned and nonutility owned may be employed to make improvements to system resiliency and power quality, in addition to simply serving load demand. By selectively dispatching active and reactive power from these existing DERs, improvements in voltage profiles and service availability during adverse events may be achieved. Further benefits can be gained by optimally choosing which DERs to dispatch power from, and the distribution of power from those DERs. For a given operating condition, using Linear Programming methods, optimal power dispatch values for individual DERs can be determined, while considering variables such as voltage gains, losses in the lines and the DERs, and DER reserve capacities. One such optimization technique is developed in this paper, and results from a real-time simulation study on a modified IEEE 13-bus distribution system with three DERs, are being presented. The operation of the optimized DER selection and dispatch algorithm is shown during normal operation of the transmission system when the DERs operate in grid-connected mode. Similar analyses can drive decision making during transmission system failure when the DERs operate in grid-forming or islanded mode.

Chowdhury, Prithwiraj Roy↗

Frequency Restoration of Grid-Forming Inverters in Pulse Load and Plug-in Events

This article presents a restoration technique using grid-forming inverters in an islanded microgrid during pulse load and plug-in events. In a microgrid powered by droop-controlled inverters, frequency is the variable that is accessible to all inverters for adjusting their power contributions. The problem is that the microgrid frequency deviates from its nominal value after a load change. The presented method enables the inverters to restore the frequency to the nominal value and regulate their bus voltage amplitudes. The frequency and voltage restorations are performed without communication while achieving the desired power-sharing between grid-forming inverters. The restoration is activated after detecting any active or reactive power changes. In this article, the dynamic model of an inverter equipped with enabled restoration paths is developed to verify the stability of the inverter controller under various conditions. The frequency and voltage restorations are examined during pulse load and plug-in events. Furthermore, this study is performed using a laboratory-scale islanded microgrid powered by two 208 V, 60 Hz, 5 kVA inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control-inspired design and power optimization of an active mechanical motion rectifier based power takeoff for wave energy converters

Ocean waves have high energy density and are persistent and predictable. Yet, converting wave energy to a useable form remains challenging. A significant hurdle is the oscillatory nature of waves resulting in the alternating loads, which necessitate the use of rectification at some stage of the energy conversion. This research effort presents a novel design of active mechanical motion rectifier (AMMR) for the power takeoff (PTO), which provides enhanced controllability and better power performance when compared to passive mechanical motion rectifiers (MMR). Inspired by transistors used in synchronous electrical rectifiers, the proposed design uses controllable electromagnetic clutches in the mechanical transmission to allow active engagement-disengagement control; thus, rectifying the oscillatory motion into a unidirectional rotation for high energy conversion efficiency and allowing the generator in unidirectional rotation to control the bidirectional wave capture structure for maximizing the power output. A semi-analytical computational approach is developed to efficiently evaluate the optimal power achieved using the proposed AMMR-based PTO and active control. It is found that the AMMR-based PTO design yields a higher optimal power than the previous passive MMR design across the wave spectrum. The influences of generator inertia and reactive power are discussed. Furthermore, the effects of control parameters on the power output and the optimal trajectories are analyzed. Wave tank tests with the AMMR prototype demonstrated the effectiveness of AMMR based PTO design and validated the numerical analysis.

16 TIDAL AND WAVE POWER↗

CyRRL (Cyber Resilient Reinforcement Learning for grid voltage control) [SWR-24-115]

This codebase contains a multi-agent, actor-critic reinforcement learning implementation for cyber-resilient grid voltage control. It uses a 123-bus OpenDSS system as the environment, with three-phase power flow translating nodal power injections into solved nodal voltages. The reward function penalizes deviations from nominal voltage as well as reactive power dispatch, while encouraging agents to take actions that result in fast convergence to nominal conditions. The codebase models false data injection attacks and includes functionality for training, testing, hyper-parameter tuning, and visualization.

Murphy, Sinnott [National Renewable Energy Laborat↗

Photovoltaic power conditioning subsystem: State of the art and development opportunities

Photovoltaic systems, the state of the art of power conditioning subsystem components, and the design and operational interaction between photovoltaic systems and host utilities are detailed in this document. Major technical issues relating to the design and development of power conditioning systems for photovoltaic application are considered; these include: (1) standards, guidelines, and specifications; (2) cost effective hardware design; (3) impact of advanced components on power conditioning development; (4) protection and safety; (5) quality of power; (6) system efficiency; and (7) system integration with the host utility. Theories of harmonic distortion and reactive power flow are discussed, and information about power conditioner hardware and manufacturers is provided.

Krauthamer, S.↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗