Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Signatures of Recent Cosmic-Ray Acceleration in the High-latitude Gamma-Ray Sky

Cosmic-ray (CR) sources temporarily enhance the relativistic particle density in their vicinity over the background distribution accumulated from the Galaxy-wide past injection activity and propagation. If individual sources are close enough to the solar system, their localized enhancements may present as features in the measured spectra of the CRs and in the associated secondary electromagnetic emissions. Large-scale loop-like structures visible in the radio sky are possible signatures of such nearby CR sources. If so, these loops may also have counterparts in the high-latitude γ-ray sky. Using ~10 yr of data from the Fermi Large Area Telescope, applying Bayesian analysis including Gaussian Processes, we search for extended enhanced emission associated with putative nearby CR sources in the energy range from 1 GeV to 1 TeV for the sky region |b| > 30°. We carefully control the systematic uncertainty due to imperfect knowledge of the interstellar gas distribution. Radio Loop IV is identified for the first time as a γ-ray emitter, and we also find significant emission from Loop I. Furthermore, strong evidence is found for asymmetric features about the Galactic l = 0° meridian that may be associated with parts of the so-called "Fermi Bubbles," and some evidence is also found for γ-ray emission from other radio loops. Implications for the CRs producing the features and possible locations of the sources of the emissions are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Electronic Population Transfer via Impulsive Stimulated X-Ray Raman Scattering with Attosecond Soft-X-Ray Pulses

Free electron lasers provide a source of X-ray pulses short enough and intense enough to drive nonlinearities in molecular systems. Impulsive interactions driven by these X-ray pulses provide a way to create and probe valence electron motions with high temporal and spatial resolution. Observing these electronic motions is crucial to understand the role of electronic coherence in chemical processes. A simple nonlinear technique for probing electronic motion, impulsive stimulated X-ray Raman scattering (ISXRS), involves a single impulsive interaction to produce a coherent superposition of electronic states. In this work, we demonstrate electronic population transfer via ISXRS using broad bandwidth (5.5 eV full width at half maximum) attosecond X-ray pulses produced by the Linac Coherent Light Source (LCLS). The impulsive excitation is resonantly enhanced by the oxygen 1s → 2π* resonance of nitric oxide (NO), and excited state neutral molecules are probed with a time-delayed UV laser pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Controllable X-ray Pulse Trains from Enhanced Self-Amplified Spontaneous Emission

We report the demonstration of optical compression of an electron beam and the production of controllable trains of femtosecond, soft x-ray pulses with the Linac Coherent Light Source (LCLS) freeelectron laser (FEL). This is achieved by enhanced self-amplified spontaneous emission with a 2 μm laser and a dechirper device. Optical compression was achieved by modulating the energy of an electron beam with the laser and then compressing with a chicane, resulting in high current spikes on the beam which we observe to lase. A dechirper was then used to selectively control the lasing region of the electron beam. Field autocorrelation measurements indicate a train of pulses, and we find that the number of pulses within the train can be controlled (from 1 to 5 pulses) by varying the dechirper position and undulator taper. These results are a step toward attosecond spectroscopy with x-ray FELs as well as future FEL schemes relying on optical compression of an electron beam.

Duris, Joseph P↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

Resonant X-ray scattering of biological assemblies

Understanding the relationship between structure and function for biological assemblies can guide identification of new therapeutics, design of biomaterials, and development of biotechnological processes. Resonant X-ray scattering provides a chemically-specific approach to characterize complex biological structures based on anomalous or resonant scattering from a specific element or chemical moiety. Anomalous or resonant diffraction can provide structural details with high atomic resolution, while resonant X-ray scattering can provide structural details with lower resolution through tender or soft X-rays. Furthermore, we review applications, challenges, and opportunities for resonant X-ray scattering in the field of structural biology.

36 MATERIALS SCIENCE↗

X-ray Fluorescence Microscopy to Develop Elemental Classifiers and Investigate Elemental Signatures in BALB/c Mouse Intestine a Week after Exposure to 8 Gy of Gamma Rays

Iron redistribution in the intestine after total body irradiation is an established phenomenon. However, in the literature, there are no reports about the use of X-ray fluorescence microscopy or equivalent techniques to generate semi-quantitative 2D maps of iron in sectioned intestine samples from irradiated mice. In this work, we used X-ray fluorescence microscopy (XFM) to map the elemental content of iron as well as phosphorus, sulfur, calcium, copper and zinc in tissue sections of the small intestine from eight-week-old BALB/c male mice that developed gastrointestinal acute radiation syndrome (GI-ARS) in response to exposure to 8 Gray of gamma rays. Seven days after irradiation, we found that the majority of the iron is localized as hot spots in the intercellular regions of the area surrounding crypts and stretching between the outer perimeter of the intestine and the surface cell layer of villi. In addition, this study represents our current efforts to develop elemental cell classifiers that could be used for the automated generation of regions of interest for analyses of X-ray fluorescence maps. Once developed, such a tool will be instrumental for studies of effects of radiation and other toxicants on the elemental content in cells and tissues. While XFM studies cannot be conducted on living organisms, it is possible to envision future scenarios where XFM imaging of single cells sloughed from the human (or rodent) intestine could be used to follow up on the progression of GI-ARS.

X-ray fluorescence microscopy↗

Crystal Structure of Moganite and Its Anisotropic Atomic Displacement Parameters Determined by Synchrotron X-ray Diffraction and X-ray/Neutron Pair Distribution Function Analyses

The crystal structure of moganite from the Mogán formation on Gran Canaria has been re-investigated using high-resolution synchrotron X-ray diffraction (XRD) and X-ray/neutron pair distribution function (PDF) analyses. Our study for the first time reports the anisotropic atomic displacement parameters (ADPs) of a natural moganite. Rietveld analysis of synchrotron XRD data determined the crystal structure of moganite with the space group I2/a. The refined unit-cell parameters are a = 8.7363(8), b = 4.8688(5), c = 10.7203(9) Å, and β = 90.212(4)°. The ADPs of Si and O in moganite were obtained from X-ray and neutron PDF analyses. The shapes and orientations of the anisotropic ellipsoids determined from X-ray and neutron measurements are similar. The anisotropic ellipsoids for O extend along planes perpendicular to the Si-Si axis of corner-sharing SiO4 tetrahedra, suggesting precession-like movement. Neutron PDF result confirms the occurrence of OH over some of the tetrahedral sites. We postulate that moganite nanomineral is stable with respect to quartz in hypersaline water. The ADPs of moganite show a similar trend as those of quartz determined by single-crystal XRD. In short, the combined methods can provide high-quality structural parameters of moganite nanomineral, including its ADPs and extra OH position at the surface. This approach can be used as an alternative means for solving the structures of crystals that are not large enough for single-crystal XRD measurements, such as fine-grained and nanocrystalline minerals formed in various geological environments.

58 GEOSCIENCES↗

Intact archeological human bones and age at death studied with transmission x–ray diffraction and small angle x–ray scattering

In this work, high-energy, wide-angle x-ray scattering (WAXS, x-ray diffraction) and small-angle x-ray scattering (SAXS) were used to study intact human second metacarpal bones (mc2) from two UK archeological sites. A novel method correcting for irregular mass distribution was applied in these transmission geometry experiments done at beamline 1-ID of the Advanced Photon Source. The authors asked whether there were age-at-death-related changes in carbonated apatite (cAp) lattice parameters and whether SAXS could detect collagen D-period peaks in the archeological mc2. For each of the two sites, Ancaster and Wharram Percy in England, six female mc2s were studied; for each site, two were from each of three age-at-death cohorts (young, 18-29 years; middle, 30-49 years; old >= 50 years) along with a modern control mc2. The Rietveld method was applied to the WAXS patterns to provide precise lattice parameter values. The cAp lattice parameters did not correlate with age-at-death estimated from dental wear. From WAXS and the 00.2 diffraction peak widths, four archeological mc2s possessed coherently scattering domain lengths (crystallite c-axis sizes) that matched that of the modern mc2; SAXS revealed the same four archeological mc2 had D-period peak intensities equivalent to that of the modern mc2. The other eight archeological mc2s had significantly larger crystallite sizes (than the modern mc2) and weak or absent D-period peaks, differences attributed to diagenetic changes. Based on these data, the authors suggest that WAXS 00.2 peak width and SAXS D-period peak intensity can be used with intact bones to select those likely to retain largely unaltered tissue nanostructure, which might be required for other analyses. Taken as a whole, the results suggest detecting age-related deterioration in nanostructural features may be difficult in bone showing significant bioerosion.

59 BASIC BIOLOGICAL SCIENCES↗

Solvent-dependent complex reaction pathways of bromoform revealed by time-resolved X-ray solution scattering and X-ray transient absorption spectroscopy

The photochemical reaction pathways of CHBr3 in solution were unveiled using two complementary X-ray techniques, time-resolved X-ray solution scattering (TRXSS) and X-ray transient absorption spectroscopy, in a wide temporal range from 100 ps to tens of microseconds. By performing comparative measurements in protic (methanol) and aprotic (methylcyclohexane) solvents, we found that the reaction pathways depend significantly on the solvent properties. In methanol, the major photoproducts are CH3OCHBr2 and HBr generated by rapid solvolysis of iso-CHBr2-Br, an isomer of CHBr3. In contrast, in methylcyclohexane, iso-CHBr2-Br returns to CHBr3 without solvolysis. In both solvents, the formation of CHBr2 and Br is a competing reaction channel. From the structural analysis of TRXSS data, we determined the structures of key intermediate species, CH3OCHBr2 and iso-CHBr2-Br in methanol and methylcyclohexane, respectively, which are consistent with the structures from density functional theory calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical and x-ray characterization of the Daedalus ultrafast x-ray imager

The Daedalus ultrafast x-ray imager is the latest generation in Sandia’s hybrid CMOS detector family. With three frames along an identical line of sight, 1 ns minimum integration time, a higher full well than Icarus, and added features, Daedalus brings exciting new capabilities to diagnostic applications in inertial confinement fusion and high energy density science. In this work, we present measurements of time response, dynamic range, spatial uniformity, pixel cross-talk, and absolute x-ray sensitivity using pulsed optical and x-ray sources. Here, we report a measured 1.5 Me — full well, pixel sensitivity at 9.58 × 10 —7 V/e — , and an estimate of spatial uniformity at ~5% across the sensor array.

47 OTHER INSTRUMENTATION↗

The Effect of Intensity Fluctuations on Sequential X-ray Photon Correlation Spectroscopy at the X-ray Free Electron Laser Facilities

How materials evolve at thermal equilibrium and under external excitations at small length and time scales is crucial to the understanding and control of material properties. X-ray photon correlation spectroscopy (XPCS) at X-ray free electron laser (XFEL) facilities can in principle capture dynamics of materials that are substantially faster than a millisecond. However, the analysis and interpretation of XPCS data is hindered by the strongly fluctuating X-ray intensity from XFELs. Here we examine the impact of pulse-to-pulse intensity fluctuations on sequential XPCS analysis. We show that the conventional XPCS analysis can still faithfully capture the characteristic time scales, but with substantial decrease in the signal-to-noise ratio of the g2 function and increase in the uncertainties of the extracted time constants. We also demonstrate protocols for improving the signal-to-noise ratio and reducing the uncertainties.

36 MATERIALS SCIENCE↗

X-ray and gamma-ray tomographic imaging of fuel relocation inside sodium fast reactor test assemblies during severe accidents

The present work reports on x-ray and gamma-ray high-spatial resolution computerized tomography measurements of the Pin Bundle Metallic Fuel Relocation (PBR) assemblies tested in the Metallic Uranium Safety Experiment (MUSE) facility at Argonne National Lab (ANL). The aim of the study was to characterize fuel relocation structures that develop during severe core accidents pertaining to SFR assemblies; these include but are not limited to advanced core disruption recreated in the PBR-1 assembly, and cladding breach recreated in the PBR-2 assembly. We report the x-ray tomography measurements were able to resolve small quantities of relocation fuel; with increased presence of relocation fuel, the x-ray 1measurements spatially mapped the material but could not resolve the inner regions of these. The gamma-tomography measurements showed improved results, resolving the relocation structures in great detail. The upper plenum of the PBR-1 assembly where the molten uranium was initially inserted presented high structural damage, reflected by the partial and complete disintegration of the central rods. Relocation fuel filled the subchannels, adhering to surviving cladding walls and the assembly casing. In the lower portion of the measured section, the tomogram degrades due to photon starvation effects hinting at the increased amount of relocation fuel potentially plugging the assembly; flow blockage in this section was difficult to determine due to the tomogram’s degradation from photon starvation. Small fragments were observed further down the assembly, dislodged from the initial insertion of the molten material. This section was used as an unperturbed assembly reference, with a calculated blockage of less than 1% from the present fragments. The PBR-2 assembly was characterized by columnar relocation structures propagating through the subchannels. Three of the relocation structures were captured in the measured section, with evidence of cross migration on to adjacent subchannels. The measured section in this assembly captures the leading edge of two structures. The calculated flow blockage was 16% in the planes where the three relocation structures are present, but this quickly decreases to approximately 5% past the leading edge of two of the structures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Time-Resolved X-ray Emission Spectroscopy and Resonant Inelastic X-ray Scattering Spectroscopy of Laser Irradiated Carbon

The existence of liquid carbon as an intermediate phase preceding the formation of novel carbon materials has been a point of contention for several decades. Experimental observation of such a liquid state requires nonthermal melting of solid carbon materials at various laser fluences and pulse properties. Reflectivity experiments performed in the mid-1980s reached opposing conclusions regarding the metallic or insulating properties of the purported liquid state. Time-resolved X-ray absorption studies showed shortening of C–C bonds and increasing diffraction densities, thought to evidence a liquid or glassy carbon state, respectively. Nevertheless, none of these experiments provided information on the electronic structure of the proposed liquid state. Herein, we report the results of time-resolved resonant inelastic X-ray scattering (RIXS) and time-resolved X-ray emission spectroscopy (XES) studies on amorphous carbon (a-C) and ultrananocrystalline diamond (UNCD) as a function of delay time between the irradiating pulse and X-ray probe. For both a-C and UNCD, we attribute decreases in RIXS or XES signals to transition blocking, relaxation, and finally, ablation. Increased signal at 20 ps following the irradiation of the UNCD is attributed to the probable formation of nanoscale structures in the ablation plume. Further, differences in the amount of signal observed between a-C and UNCD are explained by the difference in sample thickness and, specifically, incomplete melting of the UNCD film. Comparisons to spectral simulations based on MD trajectories at extreme conditions indicate that the carbon state in our experiments is crystalline. Normal mode analysis confirmed that symmetrical bending or stretching of the C–C bonds in the diamond lattice results in XES spectra with small intensity differences. Overall, we observed no evidence of melting to a liquid state, as determined by the lack of changes in the spectral properties for up to 100 ps delays following the melting pulses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous bright- and dark-field X-ray microscopy at X-ray free electron lasers

Abstract The structures, strain fields, and defect distributions in solid materials underlie the mechanical and physical properties across numerous applications. Many modern microstructural microscopy tools characterize crystal grains, domains and defects required to map lattice distortions or deformation, but are limited to studies of the (near) surface. Generally speaking, such tools cannot probe the structural dynamics in a way that is representative of bulk behavior. Synchrotron X-ray diffraction based imaging has long mapped the deeply embedded structural elements, and with enhanced resolution, dark field X-ray microscopy (DFXM) can now map those features with the requisite nm-resolution. However, these techniques still suffer from the required integration times due to limitations from the source and optics. This work extends DFXM to X-ray free electron lasers, showing how the $$10^{12}$$ 10 12 photons per pulse available at these sources offer structural characterization down to 100 fs resolution (orders of magnitude faster than current synchrotron images). We introduce the XFEL DFXM setup with simultaneous bright field microscopy to probe density changes within the same volume. This work presents a comprehensive guide to the multi-modal ultrafast high-resolution X-ray microscope that we constructed and tested at two XFELs, and shows initial data demonstrating two timing strategies to study associated reversible or irreversible lattice dynamics.

47 OTHER INSTRUMENTATION↗

Single-shot X-ray absorption spectroscopy at X-ray free electron lasers

X-ray Absorption Spectroscopy (XAS) is a widely used X-ray diagnostic method for studying electronic and structural properties of matter. At first glance, the relatively narrow bandwidth and the highly fluctuating spectral structure of X-ray Free Electron Lasers (XFEL) sources seem to require accumulation over many shots to achieve high data quality. To date the best approach to implementing XAS at XFEL facilities has been using monochromators to scan the photon energy across the desired spectral range. While this is possible for easily reproducible samples such as liquids, it is incompatible with many important systems. Here, we demonstrate collection of single-shot XAS spectra over 10s of eV using an XFEL source, with error bars of only a few percent. We additionally show how to extend this technique over wider spectral ranges towards Extended X-ray Absorption Fine Structure measurements, by concatenating a few tens of single-shot measurements. Our results pave the way for future XAS studies at XFELs, in particular those in the femtosecond regime. This advance is envisioned to be especially important for many transient processes that can only be initiated at lower repetition rates, for difficult to reproduce excitation conditions, or for rare samples, such as those encountered in high-energy density physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Characterizing electronic and atomic structures for amorphous and molecular metal oxide catalysts at functional interfaces by combining soft X-ray spectroscopy and high-energy X-ray scattering

Amorphous thin film materials and heterogenized molecular catalysts supported on electrode and other functional interfaces are widely investigated as promising catalyst formats for applications in solar and electrochemical fuels catalysis. However the amorphous character of these catalysts and the complexity of the interfacial architectures that merge charge transport properties of electrode and semiconductor supports with discrete sites for multi-step catalysis poses challenges for probing mechanisms that activate and tune sites for catalysis. This minireview discusses advances in soft X-ray spectroscopy and high-energy X-ray scattering that provide opportunities to resolve interfacial electronic and atomic structures, respectively, that are linked to catalysis. This review discusses how these techniques can be partnered with advances in nanostructured interface synthesis for combined soft X-ray spectroscopy and high-energy X-ray scattering analyses of thin film and heterogenized molecular catalysts. Further, these combined approaches enable opportunities for the characterization of both electronic and atomic structures underlying fundamental catalytic function, and that can be applied under conditions relevant to device applications.

14 SOLAR ENERGY↗