Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rate design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Optimizing Transition-Edge Sensor Design for High Count-Rate Applications

We are developing transition-edge sensor (TES) X-ray detectors optimized for high count-rate applications. These devices are fabricated on thick (300 {mu}m) Si substrates, resulting in a 20 times increase in thermal conductance to the heat sink compared to our conventional membrane isolated TES's. Operating a TES with higher heat sink conductance requires 4.5 times more bias current. This results in a 2.7 times increase in {beta}, the logarithmic derivative of resistance with respect to current. Noise measurements show a lower limit on the TES excess noise scales as (2{beta}){sup 1/2}, consistent with the near-equilibrium, non-linear expansion of the Ohmic Johnson noise. This is consistent with our membrane devices though the increased {beta} means the theoretical best attainable resolution is degraded by 25-35%. We have tested devices with different contact geometries between the absorber, and the TES and substrate. This allows us to investigate the loss of athermal phonons to the substrate, which can degrade the resolution. Results show a correlation between the stem contact area and a low-energy tail in the spectral response at 5.9 keV due to the athermal phonon loss. In several devices tested we demonstrate a resolution of 4.1-5.6 eV, coupled with detector time constants as fast as 44 {mu}s, representing an increase in detector response by 7 times compared to the membrane devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Regulatory Considerations Associated with the Expanded Adoption of Distributed Solar

Increased adoption of distributed PV, and other forms of distributed generation, have the potential to affect utility-customer interactions, system costs recovery, and utility revenue streams. If a greater number of electricity customers choose to self-generate, demand for system power will decrease and utility fixed costs will have to be recovered over fewer kilowatt hours of sales. As such, regulators will need to determine the value and cost of additional distributed PV and determine the appropriate allocation of the costs and benefits among consumers. The potential for new business models to emerge also has implications for regulation and rate structures that ensure equitable solutions for all electricity grid users. This report examines regulatory tools and rate designs for addressing emerging issues with the expanded adoption of distributed PV and evaluates the potential effectiveness and viability of these options going forward. It offers the groundwork needed in order for regulators to explore mechanisms and ensure that utilities can collect sufficient revenues to provide reliable electric service, cover fixed costs, and balance cost equity among ratepayers -- while creating a value proposition for customers to adopt distributed PV.

14 SOLAR ENERGY↗

EDS V26 Containment Vessel Explosive Qualification Test Report

The objective of the test was to qualify the vessel for its intended use by subjecting it to a 1.25 times overtest. The criteria for success are that the measured strains do not exceed the calculated strains from the vessel analysis, there is no significant additional plastic strain on subsequent tests at the rated design load (shakedown), and there is no significant damage to the vessel and attached hardware that affect form, fit, or function. Testing of the V25 Vessel in 2011 established a precedent for testing V26 [2]. As with V25, two tests were performed to satisfy this objective. The first test used 9 pounds of Composition C-4 (11.25 lbs. TNT-equivalent), which is 125 percent of the design basis load. The second test used 7.2 pounds of Composition C-4 (9 lbs. TNT-equivalent) which is 100 percent of the design basis load. The first test provided the required overtest while the second test served to demonstrate shakedown and the absence of additional plastic deformation. Unlike the V25 vessel, which was mounted in a shipping cradle during testing, the V26 vessel was mounted on the EDS P2U3 trailer prior to testing. Visual inspections of the EDS vessel, surroundings, and diagnostics were completed before and after each test event. This visual inspection included analyzing the seals, fittings, and interior surfaces of the EDS vessel and documenting any abnormalities or damages. Photographs were used to visually document vessel conditions and findings before and after each test event.

36 MATERIALS SCIENCE↗

High Efficiency Room Air Conditioner

This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.

EER↗

Midmarket Solar Policies in the United States: A Guide for Midsized Solar Customers

The midscale market for solar photovoltaics (PV) has not experienced the same high growth rate as residential- or utility-scale market segments in the past five years when solar PV deployment increased rapidly. Midscale solar can be defined as behind-the-meter solar PV between 50 kilowatts and 2 megawatts adopted by multi-housing residential, commercial, industrial, non-profit, and other entities. A number of challenges face the midscale segment, including difficulties in contracting, mismatch between tenant lease and PV financing terms, high transaction costs relative to project sizes, and inefficiencies in matching prospective projects with capital. The changing policy landscape across U.S. states provides both opportunities and challenges to midmarket solar. Some states, such as California, are expanding system capacity limits for policies such as net metering, thus enabling a wider range of customers to benefit from excess generation. A number of states and utilities are making changes to rate design to introduce new or higher user fees for solar customers or reduced tariffs for net metering, which decrease the value of solar generation. An understanding of these policies relative to project feasibility and economics is important for prospective customers to make informed decisions to adopt solar PV. This guide complements existing solar policy resources to help potential customers navigate through the policy landscape in order to make informed decisions for their solar investment. The first part of this guide introduces the key solar policies necessary for policy-based decision-making, which involves using knowledge of a solar policy to improve project economics and efficiency. Policies that could result in policy-based decisions include interconnection standards, net metering, user fees, incentives, and third-party ownership policies. The goal of this section is to equip prospective customers and project developers with the tools necessary to understand and use solar policies in a dynamic policy environment. The second part of this guide provides a complete, state-by-state inventory of midmarket solar policies for potential customers and developers to use as reference when making policy-based decisions. Although solar policies are dynamic, the profiles provide a framework for assessing policies to build the parameters that could be used to determine feasibility and structure of a solar PV system for midmarket customers and developers.

14 SOLAR ENERGY↗

Evolving Grid Services, Products, and Market Opportunities for Regulated Electric Utilities

This report and policy brief focus on the more recent changes and evolutions in grid services, products, and market opportunities regulated electric utilities are offering to their customers, both traditional end-use electric customers as well as third-party party businesses. Drawing on a database of more than 50 recent examples, the most prevalent and significant evolutions are occurring in: residential retail rate design shifts toward voluntary and default time-of-use (TOU); changes to distributed generation (DG) compensation methodologies; utilization of customer and non-utility assets as non-wires alternatives (NWAs); and utility investments in electric vehicle (EV) infrastructure. Important and related themes emerge from this assessment of recent trends suggesting regulators and policymakers should formulate clear and consistent policy goals around the following two issues: 1. Opportunities increasing competition to serve the electricity needs of retail customers. Reforms that drive increases in NWAs and DG pit utility investments against customer investments and may erode the exclusivity of the utility franchise. In contrast, reforms to DG compensation, that may reduce the financial benefits of a customer’s investment, may maintain or strengthen the firmness of the utility franchise boundaries. 2.Opportunities driving greater innovation within and outside the electric industry. Electric utilities are innovating by developing novel NWA opportunities that can provide financial support for the broader adoption of DERs. There are also electric utility efforts to enable broader innovation in other industries, where utility investment in EV charging infrastructure could promote greater EV ownership and enable utility control of these resources to provide grid services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Time-Sensitive Value of Efficiency: Use Cases in Electricity Sector Planning and Programs

Most energy efficiency measures produce energy savings that vary over the course of a year. The value of the hourly electricity savings also varies over the course of a year because the cost of generating, transmitting and distributing electricity during peak demand periods may be significantly higher than during off-peak, or lower load, hours. But many planning and program activities across the United States are missing this important element. A variety of trends are changing the electricity system, including increased adoption of other distributed energy resources, electrification of buildings and vehicles, and relative costs for natural gas-fired and renewable energy generation. Knowing when energy efficiency occurs and the value of the energy or demand savings to the electricity system—the time-sensitive value of efficiency—provides public utility commissions, utilities and other decision makers with key information needed to procure the optimal amount of energy efficiency for their system. The report begins with a discussion of our approach to determining use cases and examples, and then examines the need for time-sensitive efficiency data. Next, it examines five use cases in which states, independent system operators/regional transmission operators (ISOs/RTOs), utilities, and efficiency program administrators consider the TSV-EE: (1) energy efficiency program planning and evaluation, (2) distribution system planning, (3) electricity resource planning (4) electricity rate design, and (5) state and local government activities. The report concludes with areas for future research on the time-sensitive value of efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Distributed Solar Photovoltaic Deployment via Barrier Mitigation or Removal in the Western Interconnection (Final Technical Report)

In 2017, the Western Electricity Coordinating Council (WECC) 2026 Common Case projected that distributed solar PV deployment in the Western U.S. would meet or exceed 16,106 MW of installed capacity by 2026. Of this total, 12,218 MW was projected to be deployed in California and another 3,888 MW was projected to be deployed across Arizona, Colorado, Idaho, Montana, Nevada, New Mexico, Oregon, Utah, Washington, and Wyoming. However, WIEB recognized that barriers to distributed solar PV deployment could cause the region to fall short of these projections. WIEB identified three types of perceived barriers that might interfere with the deployment of distributed solar PV generation in the West, including: (1) interconnection barriers; (2) utility rate-design barriers; and (3) reliability barriers.

14 SOLAR ENERGY↗

Advancing Equity in Utility Regulation

Increasingly, states are recognizing equity as a goal of utility regulation, going beyond traditionally stated objectives to ensure that electricity systems are reliable, safe, and fairly priced. State initiatives are critical not only to address historical inequities, but to ensure equitable benefits and burdens in the transition to net-zero emissions by 2050. This report provides four perspectives on advancing equity in electric utility regulation, from representatives of energy justice and consumer organizations and a leading utility in this area. The authors provide recommendations related to regulatory issues such as stakeholder engagement, defining "public interest," intervenor funding, electricity infrastructure siting, access to distributed energy technologies, consumer protections, bill affordability programs, rate design, program design, and metrics to track and evaluate results of policies, regulations, and programs intended to deliver equitable outcomes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State Indicators for Advancing Demand Flexibility and Energy Efficiency in Buildings - Part I [Slides]

This slide deck report identifies objectives and key indicators for state activities that advance demand flexibility in buildings — legislation, utility regulatory proceedings, executive orders and programs. It also illustrates progress to date and identifies trends, gaps, and opportunities. Part I of the report focuses on (1) demand response and (2) energy efficiency targeted to reduce peak demand or integrate with demand response. This section covers building energy codes, appliance and equipment standards, resource standards, utility planning, utility programs, advanced metering infrastructure and meter data, rate design, state programs, state energy planning, and related state policies and regulations. Part II of the report addresses traditional energy efficiency indicators, including utility and state programs, codes, and standards that support annual energy savings. See the additional links for an infographic, library of cited state documents on demand flexibility, and presentation to the NASEO-NARUC Grid-Interactive Efficient Buildings Working Group.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cyber-Physical Resiliency for Wind Power Generation

During the next three years, wind power generation is expected to add more generation capacity to the national electrical grid than any other energy sector. With new wind turbine designs rated power over 10 MW and wind farms reaching over 1 GW capacities, the consequences of cyber-attacks on wind power generation are becoming increasingly more critical. Moreover, the known vulnerabilities of wind turbine control systems and the potential damaging effects of intrusions, motivate an urgent protection improvement for the wind power generation sector. This program has developed a variety of new adaptive defense technologies that enable wind power generation systems to survive sophisticated cyberattacks by enhancing the control systems capabilities of detection, localization, and accommodation. The introduction of these technologies in the on-shore and the emerging off-shore market will result in a significantly more reliable and secure wind power infrastructure.

17 WIND ENERGY↗

Electric Vehicles: Key Trends, Issues, and Considerations for State Regulators

Over the past few years, states across the country have seen increased consumer adoption of electric vehicles (i.e., vehicles with an electric motor, or EVs), thereby increasing electricity demand from the transportation sector. This change is quickly becoming a trend, which provides utilities with an opportunity to increase electricity sales while providing customers with the possibility of lowering emissions and overall vehicle ownership costs compared to traditional internal combustion engine (ICE) vehicles. Electric utilities are at different stages of exploring their role in both building EV charging infrastructure and managing grid impacts, including through rate design and managed charging. As a result, many Public Utility Commissions (PUCs), the state agencies tasked with regulating utilities, are being asked to make decisions in this unfamiliar industry, sometimes without direct legislative guidance. This issue brief provides data about the trends in EV adoption, a synopsis of the types of decisions Commissions are facing, and examples of recent State regulatory approaches to EV questions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Examination of Factors Affecting the Cost and Performance of a Natural Gas Combined Cycle Equipped with Carbon Dioxide Capture

The purpose of this Technical Note is to report the findings of an examination of the effect of plausible deviations in select study assumptions on the reported cost and performance estimates for a power plant case drawn from NETL’s “Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity” (known as the Fossil Energy Baseline). An F-Class NGCC power plant equipped with state-of-the-art, solvent-based, post-combustion carbon dioxide (CO2) capture (95 percent carbon capture rate)—designated as Case B31B.95—was selected for this work. This sensitivity analysis provides insight into the effects of parameter variations within and across selected categories—ambient conditions, construction cost, natural gas (NG) price, capacity factor, and finance—on the plant performance and capital and operating and maintenance (O&M) costs, and the subsequent impact on common figures of merit.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis of failed and nickel-coated 3093 beam clamp components at the East Tennessee Technology Park (ETTP).

The U.S. Department of Energy and its contractor, Bechtel Jacobs Company (BJC), are undertaking a major effort to clean up the former gaseous diffusion facility (K-25) located in Oak Ridge, TN. The decontamination and decommissioning activities require systematic removal of contaminated equipment and machinery followed by demolition of the buildings. As part of the cleanup activities, a beam clamp, used for horizontal life lines (HLLs) for fall protection, was discovered to be fractured during routine inspection. The beam clamp (yoke and D-ring) was a component in the HLL system purchased from Reliance Industries LLC. Specifically, the U-shaped stainless steel yoke of the beam clamp failed in a brittle mode at under less than 10% of the rated design capacity of 14,500 lb. The beam clamp had been in service for approximately 16 months. Bechtel Jacobs approached Argonne National Laboratory to assist in identifying the root cause of the failure of the beam clamp. The objectives of this study were to (1) review the prior reports and documents on the subject, (2) understand the possible failure mechanism(s) that resulted in the failed beam clamp components, (3) recommend approaches to mitigate the failure mechanism(s), and (4) evaluate the modified beam clamp assemblies. Energy dispersive x-ray analysis and chemical analysis of the corrosion products on the failed yoke and white residue on an in-service yoke indicated the presence of zinc, sulfur, and calcium. Analysis of rainwater in the complex, as conducted by BJC, indicated the presence of sulfur and calcium. It was concluded that, as a result of galvanic corrosion, zinc from the galvanized components of the beam clamp assembly (D-ring) migrated to the corroded region in the presence of the rainwater. Under mechanical stress, the corrosion process would have accelerated, resulting in the catastrophic failure of the yoke. As suggested by Bechtel Jacobs personnel, hydrogen embrittlement as a consequence of corrosion was also explored as a failure mechanism. Corroded and failed yoke samples had hydrogen concentrations of 20-60 ppm. However, the hydrogen content reduced to 4-11 ppm (similar to baseline as-received yoke samples) when the corrosion products were polished off. The hydrogen content in the scraped off corrosion product powders was >7000 ppm. These results indicate that hydrogen is primarily present in the corrosion products and not in the underlying steel. Rockwell hardness values on the corroded yoke and D-rings were R{sub c} {approx} 41-46. It was recommended to the beam clamp manufacturer that the beam clamp components be annealed to reduce the hardness values so that they are less susceptible to brittle failure. Upon annealing, hardness values of the beam clamp components reduced to R{sub c} {approx} 25. Several strategies were recommended and put in place to mitigate failure of the beam clamp components: (a) maintain hardness levels of both yokes and D-rings at R{sub c} < 35, (b) coat the yoke and D-rings with a dual coating of nickel (with 10% phosphorus) to delay corrosion and aluminum to prevent galvanic corrosion since it is more anodic to zinc, and (c) optimize coating thicknesses for nickel and aluminum while maintaining the physical integrity of the coatings. Evaluation of the Al- and Ni-coated yoke and D-ring specimens indicated they appear to have met the recommendations. Average hardness values of the dual-coated yokes were R{sub c} {approx} 25-35. Hardness values of dual-coated D-ring were R{sub c} {approx} 32. Measured average coating thicknesses for the aluminum and nickel coatings for yoke samples were 22 {micro}m (0.9 mils) and 80 {micro}m (3 mils), respectively. The D-rings also showed similar coating thicknesses. Microscopic examination showed that the aluminum coating was well bonded to the underlying nickel coating. Some observed damage was believed to be an artifact of the cutting-and-polishing steps during sample preparation for microscopy.

08 HYDROGEN↗

Failure Analysis of Nickel-hydrogen Cell Subjected to Simulated Low Earth Orbit Cycling

A nickel-hydrogen cell completed 10,080 simulated low earth orbit charge/discharge cycles at depths-of-discharge ranging from 50 to 80 percent prior to failure. The cell is of the Air Force design, rated at 50 ampere-hours, 8.9 cm (3.5 inches) in diameter. Upon disassembly, the end of the polysulfone core supporting the electrode stack was found to have fractured. This allowed the electrode stack to expand. A massive short was found at the inner diameter of the electrodes centered roughly at plate set 34 to 37 from the positive end of the electrode stack. The damaged area extended through approximately one third of the electrode stack, with the effect becoming progressively less with distance from plate set 34 to 37. Measured thicknesses of the positive plates were significantly greater than the initial specification values. The postulated cause of failure is that positive plate growth caused fracture of the shoulder from the end of the polysulfone core on which the electrodes are mounted. The electrode stack relieved and pressure points were created at the area near the inner diameter of the plates at the tab attachment. A short occurred at a pressure point between opposing plates and propagated to other electrode sets due to thermal and mechanical stresses caused by the short.

Mueller, V. C.↗

Effects of T-tabs and large deflections in DCB specimen tests

A simple strength of materials analysis was developed for a double-cantilever beam (DCB) specimen to account for geometric nonlinearity effects due to large deflections and T-tabs. A new DCB data analysis procedure was developed to include the effects of these nonlinearities. The results of the analysis were evaluated by DCB tests performed for materials having a wide range of toughnesses. The materials used in the present study were T300/5208, IM7/8551-7, and AS4/PEEK. Based on the present analysis, for a typical deflection/crack length ratio of 0.3 (for AS4/PEEK), T-tabs and large deflections cause a 15 percent and 3 percent error, respectively, in the computer Mode 1 strain energy release rate. Design guidelines for DCB specimen thickness and T-tab height were also developed in order to keep errors due to these nonlinearities within 2 percent. Based on the test results, for both hinged and tabbed specimens, the effects of large deflection on the Mode 1 fracture toughness (G sub Ic) were almost negligible (less than 1 percent) in the case of T300/5208 and IM7/8551-7; however, AS4/PEEK showed a 2 to 3 percent effect. The effects of T-tabs G sub Ic were more significant for all the materials with T300/5208 showing a 5 percent error, IM7/8551-7 a 15 percent error, and, AS4/PEEK a 20 percent error.

Naik, R. A.↗

Feasibility study for the advanced one-dimensional high temperature optical strain measurement system, phase 3

The Instrumentation and Control Technology Division is developing optical strain measurement systems for applications using high temperature wire and fiber specimens. This feasibility study has determined that stable optical signals can be obtained from specimens at temperatures beyond 2,400 C. A system using an area array sensor is proposed to alleviate off-axis decorrelation arising from rigid body motions. A digital signal processor (DSP) is recommended to perform speckle correlations at a rate near the data acquisition rate. Design parameters are discussed, and fundamental limits on the speckle shift strain measurement technique are defined.

Lant, Christian T.↗

Current limiting remote power control module

The power source for the Space Station Freedom will be fully utilized nearly all of the time. As such, any loads on the system will need to operate within expected limits. Should any load draw an inordinate amount of power, the bus voltage for the system may sag and disrupt the operation of other loads. To protect the bus and loads some type of power interface between the bus and each load must be provided. This interface is most crucial when load faults occur. A possible system configuration is presented. The proposed interface is the Current Limiting Remote Power Controller (CL-RPC). Such an interface should provide the following power functions: limit overloading and resulting undervoltage; prevent catastrophic failure and still provide for redundancy management within the load; minimize cable heating; and provide accurate current measurement. A functional block diagram of the power processing stage of a CL-RPC is included. There are four functions that drive the circuit design: rate control of current; current sensing; the variable conductance switch (VCS) technology; and the algorithm used for current limiting. Each function is discussed separately.

Hopkins, Douglas C.↗