Engineering PapersSearch

SEARCH · Engineering Papers

Results for “radiometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A 94/183 GHz multichannel radiometer for Convair flights

A multichannel 94/183 GHz radiometer was designed, built, and installed on the NASA Convair 990 research aircraft to take data for hurricane penetration flights, SEASAT-A underflights for measuring rain and water vapor, and Nimbus-G underflights for new sea ice signatures and sea surface temperature data (94 GHz only). The radiometer utilized IF frequencies of 1, 5, and 8.75 GHz about the peak of the atmospheric water vapor absorption line, centered at 183.3 GHz, to gather data needed to determine the shape of the water molecule line. Another portion of the radiometer operated at 94 GHz and obtained data on the sea brightness temperature, sea ice signatures, and on areas of rain near the ocean surface. The radiometer used a multiple lens antenna/temperature calibration technique using 3 lenses and corrugated feed horns at 94 GHz and 183 GHz. Alignment of the feed beams at 94 GHz and 183 GHz was accomplished using a 45 deg oriented reflecting surface which permitted simultaneous viewing of the feeds on alternate cycles of the chopping intervals.

Gagliano, J. A.

Determination of the complex refractive index and size distribution of atmospheric particulates from bistatic-monostatic lidar and solar radiometer measurements

A method is presented for inferring both the size distribution and the complex refractive index of atmospheric particulates from combined bistatic-monostatic lidar and solar radiometer observations. The basic input measurements are spectral optical depths at several visible and near-infrared wavelengths as obtained with a solar radiometer and backscatter and angular scatter coefficients as obtained from a biostatic-monostatic lidar. The spectral optical depth measurements obtained from the radiometer are mathematically inverted to infer a columnar particulate size distribution. Advantage is taken of the fact that the shape of the size distribution obtained by inverting the particulate optical depth is relatively insensitive to the particle refractive index assumed in the inversion. Bistatic-monostatic angular scatter and backscatter lidar data are then processed to extract an optimum value for the particle refractive index subject to the constraint that the shape of the particulate size distribution be the same as that inferred from the solar radiometer data. Specifically, the scattering parameters obtained from the bistatic-monostatic lidar data are compared with corresponding theoretical computations made for various assumed refractive index values. That value which yields best agreement, in a weighted least squares sense, is selected as the optimal refractive index estimate. The results of this procedure applied to a set of simulated measurements as well as to measurements collected on two separate days are presented and discussed.

Reagan, J. A.

An investigation of radiometer design using digital processing techniques

The use of digital signal processing techniques in Dicke switching radiometer design was investigated. The general approach was to develop an analytical model of the existing analog radiometer and identify factors which adversly affect its performance. A digital processor was then proposed to verify the feasibility of using digital techniques to minimize these adverse effects and improve the radiometer performance. Analysis and preliminary test results comparing the digital and analog processing approaches in radiometers design were analyzed.

Lawrence, R. W.

Deconvolution of wide field-of-view radiometer measurements of earth-emitted radiation. I - Theory

The theory of deconvolution of wide field-of-view (WFOV) radiometer measurements of earth-emitted radiation provides a technique by which the resolution of such measurements can be enhanced to provide radiant exitance at the top of the atmosphere with a finer resolution than the field of view. An analytical solution for the earth-emitted radiant exitance in terms of WFOV radiometer measurements is derived for the nonaxisymmetric (or regional) case, in which the measurements and radiant exitance are considered to be functions of both latitude and longitude. This solution makes it possible to deconvolve a set of WFOV radiometer measurements of earth-emitted radiation and obtain information with a finer resolution than the instantaneous field of view of the instrument. It is shown that there are tradeoffs involved in the selection between WFOV and scanning radiometers.

Smith, G. L.

Digital signal processing in microwave radiometers

A microprocessor based digital signal processing unit has been proposed to replace analog sections of a microwave radiometer. A brief introduction to the radiometer system involved and a description of problems encountered in the use of digital techniques in radiometer design are discussed. An analysis of the digital signal processor as part of the radiometer is then presented.

Lawrence, R. W.

Ground registration of data from an airborne Multifrequency Microwave Radiometer (MfMR)

The agricultural soil moisture experiment was conducted near Colby, Kansas, in July and August 1978. A portion of the data collected was taken with a five band microwave radiometer. A method of locating the radiometer footprints with respect to a ground based coordinate system is documented. The procedure requires that the airplane's flight parameters along with aerial photography be acquired simultaneously with the radiometer data. The software which documented reads in data from the precision radiation thermometer (PRT Model 5) and attaches the scene temperature to the corresponding multifrequency microwave radiometer data. Listings of the programs used in the registration process are included.

Richter, J. C.

Errors in scatterometer-radiometer wind measurement due to rain

The behavior of radiometer corrections for the scatterometer is investigated by simulating simple situations using footprint sizes comparable with those used in the SEASAT-1 experiment and also actual footprints and rain rates from a hurricane observed by the SEASAT-1 system. The effects on correction due to attenuation and wind speed gradients are examined independently and jointly. It is shown that the error in the wind-speed estimate can be as large as 200% at higher wind speeds. The worst error occurs when the scatterometer footprint overlaps two or more radiometer footprints and the attenuation in the scatterometer footprint differs greatly from those in parts of the radiometer footprints. This problem could be overcome by using a true radiometer-scatterometer system having identical coincident footprints comparable in size with typical rain cells.

Moore, R. K.

Six mechanisms used on the SSM/1 radiometer

Future USAF Block 5D Defense Meteorological Satellites will carry a scanning microwave radiometer sensor (SSM/1). SSM/1 senses the emission of microwave energy and returns to earth data used to determine weather conditions, such as rainfall rates, soil moisture, and oceanic wind speed. The overall design of the SSM/1 radiometer was largely influenced by the mechanisms. The radiometer was designed to be stowed in a cavity on the existing spacecraft. The deployment of the sensor is complex due to the constraint of this cavity and the need for precision in the deployment. The radiometer will continuously rotate, instead of oscillate, creating the need for a bearing and power transfer assembly and a momentum compensation device. The six mechanisms developed for this program are described.

Ludwig, H. R.

Performance of an airborne imaging 92/183 GHz radiometer during the Bering Sea Marginal Ice Zone Experiment (MIZEX-WEST)

An airborne imaging 92/183 GHz radiometer was recently flown onboard NASA's Convair 990 research aircraft during the February 1983 Bering Sea Marginal Ice Zone Experiment (MIZEX-WEST). The 92 GHz portion of the radiometer was used to gather ice signature data and to generate real-time millimeter wave images of the marginal ice zone. Dry atmospheric conditions in the Arctic resulted in good surface ice signature data for the 183 GHz double sideband (DSB) channel situated + or - 8.75 GHz away from the water vapor absorption line. The radiometer's beam scanner imaged the marginal ice zone over a + or - 45 degrees swath angle about the aircraft nadir position. The aircraft altitude was 30,000 feet (9.20 km) maximum and 3,000 feet (0.92 km) minimum during the various data runs. Calculations of the minimum detectable target (ice) size for the radiometer as a function of aircraft altitude were performed. In addition, the change in the atmospheric attenuation at 92 GHz under varying weather conditions was incorporated into the target size calculations. A radiometric image of surface ice at 92 GHz in the marginal ice zone is included.

Gagliano, J. A.

Effect of vegetation on soil moisture sensing observed from orbiting microwave radiometers

The microwave radiometric measurements made by the Skylab 1.4 GHz radiometer and by the 6.6 GHz and 10.7 GHz channels of the Nimbus-7 Scanning Multichannel Microwave Radiometer were analyzed to study the large-area soil moisture variations of land surfaces. Two regions in Texas, one with sparse and the other with dense vegetation covers, were selected for the study. The results gave a confirmation of the vegetation effect observed by ground-level microwave radiometers. Based on the statistics of the satellite data, it was possible to estimate surface soil moisture in about five different levels from dry to wet conditions with a 1.4 GHz radiometer, provided that the biomass of the vegetation cover could be independently measured. At frequencies greater than about 6.6 GHz, the radiometric measurements showed little sensitivity to moisture variation for vegetation-covered soils. The effects of polarization in microwave emission were studied also.

Wang, J. R.

An upward looking airborne millimeter wave radiometer for atmospheric water vapor sounding and rain detection

A 90/180 GHz multichannel radiometer is currently under development for NASA's 1985 Hurricane Mission onboard the Convair 990 research aircraft. The radiometer will be a fixed beam instrument with dual corrugated horns and a common lens antenna designed to operate simultaneously at 90 and 180 GHz. The all solid state front-end will contain three double side band data channels at 90 + or - 3 GHz, 180 + or - 3 GHz, and 180 + or - 7 GHz. The airborne radiometer will mount in a window port on the CV-990 and will maintain a fixed beam view approximately 14 degrees off zenith. The radiometer design is a Dicke chopper arrangement selected to achieve maximum absolute temperature accuracy and minimum brightness temperature sensitivity. Analog outputs of the three data channels will be calibrated dc voltages representing the observed radiometric brightness temperatures over the selected integration time.

Gagliano, J. A.

Design and development of a multibeam 1.4 GHz pushbroom microwave radiometer

The design and operation of a multiple beam, digital signal processing radiometer are discussed. The discussion includes a brief description of each major subsystem and an overall explanation of the hardware requirements and operation. A series of flight tests was conducted in which sea-truth sites, as well as an existing radiometer were used to verify the Pushbroom Radiometer performance. The results of these tests indicate that the Pushbroom Radiometer did meet the sensitivity design goal of 1.0 kelvin, and exceeded the accuracy requirement of 2.0 kelvin. Additional performance characteristics and test results are also presented.

Lawrence, R. W.

A cavity radiometer for Earth albedo measurement, phase 1

Radiometric measurements of the directional albedo of the Earth requires a detector with a flat response from 0.2 to 50 microns, a response time of about 2 seconds, a sensitivity of the order of 0.02 mw/sq cm, and a measurement uncertainty of less than 5 percent. Absolute cavity radiometers easily meet the spectral response and accuracy requirements for Earth albedo measurements, but the radiometers available today lack the necessary sensitivity and response time. The specific innovations addressed were the development of a very low thermal mass cavity and printed/deposited thermocouple sensing elements which were incorporated into the radiometer design to produce a sensitive, fast response, absolute radiometer. The cavity is applicable to the measurement of the reflected and radiated fluxes from the Earth surface and lower atmosphere from low Earth orbit satellites. The effort consisted of requirements and thermal analysis; design, construction, and test of prototype elements of the black cavity and sensor elements to show proof-of-concept. The results obtained indicate that a black body cavity sensor that has inherently a flat response from 0.2 to 50 microns can be produced which has a sensitivity of at least 0.02 mw/sq cm per micro volt ouput and with a time constant of less than two seconds. Additional work is required to develop the required thermopile.

Source record

Multiwavelength scanning radiometer for airborne measurements of scattered radiation within clouds

A multi-wavelength scanning radiometer has been developed for measuring the angular distribution of scattered radiation deep within a cloud layer. The purpose of the instrument is to provide measurements from which the single scattering albedo of clouds can be derived as a function of wavelength. The radiometer has a 1-deg field of view and scans in the vertical plane from 5 deg before zenith to 5 deg past nadir (190 deg aperture). The thirteen channels of the cloud absorption radiometer are located between 0.5 and 2.3 microns and were selected to avoid the molecular absorption bands in the near-infrared. The first seven channels of the radiometer are simultaneously and continuously sampled, while the eighth registered channel is selected from among the six channels on a filter wheel. This paper describes the optical, mechanical and electrical design of the instrument and presents some early results obtained from measurements taken aboard the University of Washington's B-23 aircraft to illustrate the performance of the instrument.

King, Michael D.

Airborne Calibration Of An Orbiting Radiometer

Experiment demonstrates feasibility of using recently calibrated airborne radiometer to calibrate satellite-borne radiometer monitoring Earth and not calibrated since before launch. Calibration technique helps to assure Earth scientists of accuracy of satellite radiometric measurements taken during long time. Optical train of orbiting radiometer degraded slowly and sensitivities of detectors and gains of amplifiers changed slowly in outer-space environment, but frequent calibrations by airborne-radiometer technique make it possible to compensate for these changes.

Smith, Gilbert R.

The measurement of atmospheric water vapor - Radiometer comparison and spatial variations

Two water vapor radiometer (WVR) experiments were conducted to evaluate whether such instruments are both suitable and necessary to correct for propagation effects that are induced by precipitable water vapor (PWV) on signals from GPS and VLBI. WVRs are suitable for these corrections if they provide wet path delays to better than 0.5 cm. They are needed if spatial variations of PWV result in complicated, direction-dependent propagation effects that are too complex to be parametrized in the GPS or VLBI geodetic solution. The suitability of radiometers was first addressed by comparing six airport WVRs for two weeks. While two WVRs showed an average wet path delay bias of only 0.1 cm, others were biased by 1-3 cm relative to each other and relative to radiosondes. The second experiment addressed the question whether radiometers are needed for the detection of inhomogeneities in the wet delay. Three JPL D-series radiometers were operated at three sites 50 km apart. The WVRs simultaneously sampled PWV at different azimuths and elevations in search of spatial variations of PWV. On one day of this second experiment evidence was found for spatial variations of the wet path delay as high as 20 percent of the total wet path delay.

Rocken, C.

A validation tool for the Earth Radiation Budget Experiment nonscanning radiometers

Two data sets for one geographical scene are used as a comparative validation tool to verify the quality of radiometer measurements taken for NASA's Earth Radiation Budget Experiment (ERBE). The measurements are taken from four independent nonscanning radiometers installed on the Earth Radiation Budget Satellite and two NOAA spacecraft. Two radiometers measure radiation in the 0.2-50-micron range, and two measure solar reflected energy in spectral band ranging from 0.2 to 5 microns. Calculated top-of-atmosphere flux-value measurements for day and night demonstrate significant correlation as well as consistency and stability over a three-year period. It is concluded that intercomparisons of intersections between the satellites are necessary over varied geographical scenes to utilize the subject method in validating the measurements of the ERBE nonscanning radiometer.

Bolden, William C.

Multi-frequency, multi-polarization SAR and radiometer sea ice classification

Microwave remotely sensed data were acquired simultaneously in March 1988 over Beaufort, Chukchi, and Bering Sea ice using the JPL multifrequency, polarimetric synthetic aperture radar (SAR), and multifrequency dual-polarization GSFC radiometer. The experiment was conducted as a series of coordinated underflights of the DMSP SSM/I satellite radiometer to validate ice products derived from its radiance values. Concurrent flights by an NRL P-3 aircraft enabled overlapping high-resolution, single-frequency images to be acquired over the same surfaces using a Ka-band scanning microwave radiometer. Precise coregistration to an accuracy of 100 m, +/- 25 m enables comparison of temporally and spatially coincident active and passive microwave datasets. Three-channel polarimetric SAR data are compared with dual-polarized radiometer data at several SSM/I frequencies, showing backscatter signatures to be highly correlated with radiometric temperatures. Further comparisons are used to evaluate ice concentration retrievals and to show how multiparameter datasets can be used to resolve ambiguities present in identifying certain sea ice forms with a single microwave instrument.

Drinkwater, Mark R.