Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The use of ultrasonic property measurements as the basis for finite element analysis of composite materials

In this work, the use of ultrasonic property measurements as the basis for finite element analysis of full scale composite components is presented. The approach utilizes multiple velocity measurements at oblique angles of incidence and quantitative analysis of radiographic images for the local determination of each of the nine orthotropic moduli in a woven carbon-carbon composite. These values were then used as input into a finite element code (NASTRAN) to analyze the response of the material to load: here, diametric compression. The predicted response was then compared with strain gage results at several locations to validate the approach.

Madaras, E. I.↗

Thermal neutron image intensifier tube provides brightly visible radiographic pattern

Vacuum-type neutron image intensifier tube improves image detection in thermal neutron radiographic inspection. This system converts images to an electron image, and with electron acceleration and demagnification between the input target and output screen, produces a bright image viewed through a closed circuit television system.

Berger, H.↗

Application of an electronic image analyzer to dimensional measurements from neutron radiographs

Means of obtaining improved dimensional measurements from neutron radiographs of nuclear fuel elements are discussed. The use of video-electronic image analysis relative to edge definition in radiographic images is described. Based on this study, an edge definition criterion is proposed for overcoming image unsharpness effects in taking accurate diametral measurements from radiographs. An electronic density slicing method for automatic edge definition is described. Results of measurements made with video micrometry are compared with scanning microdensitometer and micrometric physical measurements. An image quality indicator for estimating photographic and geometric unsharpness is described.

Vary, A.↗

Composite x-ray image assembly for large-field digital mammography with one- and two-dimensional positioning of a focal plane array

To demonstrate the feasibility of a novel large-field digital mammography technique, a 1024 x 1024 pixel Loral charge-coupled device (CCD) focal plane array (FPA) was positioned in a mammographic field with one- and two-dimensional scan sequences to obtain 950 x 1800 pixel and 3600 x 3600 pixel composite images, respectively. These experiments verify that precise positioning of FPAs produced seamless composites and that the CCD mosaic concept has potential for high-resolution, large-field imaging. The proposed CCD mosaic concept resembles a checkerboard pattern with spacing left between the CCDs for the driver and readout electronics. To obtain a complete x-ray image, the mosaic must be repositioned four times, with an x-ray exposure at each position. To reduce the patient dose, a lead shield with appropriately patterned holes is placed between the x-ray source and the patient. The high-precision motorized translation stages and the fiber-coupled-scintillating-screen-CCD sensor assembly were placed in the position usually occupied by the film cassette. Because of the high mechanical precision, seamless composites were constructed from the subimages. This paper discusses the positioning, image alignment procedure, and composite image results. The paper only addresses the formation of a seamless composite image from subimages and will not consider the effects of the lead shield, multiple CCDs, or the speed of motion.

Mammography/methods/statistics & numerical data↗

Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction

This paper presents a new reconstruction algorithm for both single- and dual-energy computed tomography (CT) imaging. By incorporating the polychromatic characteristics of the X-ray beam into the reconstruction process, the algorithm is capable of eliminating beam hardening artifacts. The single energy version of the algorithm assumes that each voxel in the scan field can be expressed as a mixture of two known substances, for example, a mixture of trabecular bone and marrow, or a mixture of fat and flesh. These assumptions are easily satisfied in a quantitative computed tomography (QCT) setting. We have compared our algorithm to three commonly used single-energy correction techniques. Experimental results show that our algorithm is much more robust and accurate. We have also shown that QCT measurements obtained using our algorithm are five times more accurate than that from current QCT systems (using calibration). The dual-energy mode does not require any prior knowledge of the object in the scan field, and can be used to estimate the attenuation coefficient function of unknown materials. We have tested the dual-energy setup to obtain an accurate estimate for the attenuation coefficient function of K2 HPO4 solution.

NASA Center ARC↗

New Design Yields Robust Large-Area Framing Camera

Manuscript to be submitted to Review of Scientific Instruments to determine interest in possible publication. Website: https://aip.scitation.org/rsi/authors/manuscript High-speed imaging is a core diagnostic capability for the Nevada National Security Site (NNSS). Data from experiments that measure the behavior of materials under extreme conditions are essential for the stockpile mission. For example, during subcritical experiments, materials that are shocked and compressed under high-explosive drive change behavior rapidly over timescales measured in millionths or even billionths of a second. Characterizing and understanding this behavior requires radiographic and/or optical imaging to track motion on these timescales. Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A technique to correct for sample thickness variations for use with IDAPS X-ray radiograph analysis

The Image Data Processing System (IDAPS) at the Marshall Space Flight Center is used to analyze radiographs of metal samples to qualitatively and quantitatively map compositional variations across the samples. When the X-ray radiographs are of samples having thickness variations, corrections must be made to accomplish compositional analysis. A correction technique is described for cylindrical samples and is applied to radiographs of SPAR Experiment 74-18. Uncorrected and corrected images are shown.

Schafer, C. F.↗

Improving radiograph analysis throughput through transfer learning and object detection

SIGN Fracture Care International partners with surgeons in low-resource hospitals worldwide to provide access to effective orthopedic care by donating educational materials and innovatively designed surgical implants. Over two decades, SIGN’s Online Surgical Database (SOSD) has grown to contain over 500,000 medical images, with radiographs holding the majority share. One challenge in working with hospitals worldwide is that both the radiographs uploaded to the SOSD and the data entry accompanying the uploads vary in quality. To improve the accuracy of data in the SOSD, we trained a model to detect surgical implants in radiographs. We first developed a tool to automatically detect radiographs, then trained an object detection model to determine the number and placement of surgical implants visible in the radiograph. Active learning was used to generate a training set containing 2,510 radiographs with screws, nails, and plates labeled by bounding boxes. Training a model to simultaneously recognize all three classes of implants gave a low average precision (AP) for the plate class, likely due to the low number of plate instances in our training set and the large variety of surgical plates used by SIGN-partnered surgeons. Applying standard image augmentation techniques to increase the plate count in our training set did not appreciably increase the AP of plate detection. To improve plate detection, we redrew the bounding boxes to account for correlations between the screw and plate classes. Training one model to detect nails and screws and a separate model to detect plates increased the AP of plate detection by 78.8 percentage points. The AP of each class was 80.7% for screws, 93.6% for nails, and 92.6% for plates; meanwhile, the sensitivity was 92% for screws, 86% for nails, and 81% for plates. We show that object detection methods can be used to detect surgical implants in radiographs of varying quality; however, the detection ability is dependent on the type of implant, and some implants, in our case plates, must be treated differently than others. Such tools can improve the throughput of radiograph analysis, assisting physicians and surgeons with the treatment of bone fractures.

60 APPLIED LIFE SCIENCES↗

Kraken Camera System

Specification sheet for Kraken camera system being developed by NNSS Transformational Diagnostics and Imaging in Los Alamos. Will be shared internally and externally.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kraken Imager and Camera Systems

Presentation describes the Kraken imager and camera systems under development for use at the Nevada National Security Site for work conducted by the National Nuclear Security Administration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Design Yields Robust Large-Area Framing Camera

Framing cameras provide a discrete series of images over a short period of time in a manner that mimics a high-speed movie camera, but with individual shutter times that must be extremely short in order to capture freeze-frame images of rapidly evolving phenomena such as high-explosive shock-driven ejecta, dynamic compression of metals, and high-velocity fluid flow. The NNSS has designed and fielded a new, large-area, gated framing camera called Kraken. The camera design emphasized manufacturability and flexibility by improving imager yield and creating a camera architecture to shorten design cycles. Design strategies and field data are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neural network methods for radiation detectors and imaging

Recent advances in image data proccesing through deep learning allow for new optimization and performance-enhancement schemes for radiation detectors and imaging hardware. This enables radiation experiments, which includes photon sciences in synchrotron and X-ray free electron lasers as a subclass, through data-endowed artificial intelligence. We give an overview of data generation at photon sources, deep learning-based methods for image processing tasks, and hardware solutions for deep learning acceleration. Most existing deep learning approaches are trained offline, typically using large amounts of computational resources. However, once trained, DNNs can achieve fast inference speeds and can be deployed to edge devices. A new trend is edge computing with less energy consumption (hundreds of watts or less) and real-time analysis potential. While popularly used for edge computing, electronic-based hardware accelerators ranging from general purpose processors such as central processing units (CPUs) to application-specific integrated circuits (ASICs) are constantly reaching performance limits in latency, energy consumption, and other physical constraints. These limits give rise to next-generation analog neuromorhpic hardware platforms, such as optical neural networks (ONNs), for high parallel, low latency, and low energy computing to boost deep learning acceleration (LA-UR-23-32395).

edge computing↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method of radiographic inspection of wooden members

The invention is a method to be used for radiographic inspection of a wooden specimen for internal defects which includes the steps of introducing a radiopaque penetrant into any internal defects in the specimen through surface openings; passing a beam of radiation through a portion of the specimen to be inspected; and making a radiographic film image of the radiation passing through the specimen, with the radiopaque penetrant in the specimen absorbing the radiation passing through it, thereby enhancing the resulting image of the internal defects in the specimen.

Berry, Maggie L.↗

The Effect of Experimental Variables on Industrial X-Ray Micro-Computed Sensitivity

A study was performed on the effect of experimental variables on radiographic sensitivity (image quality) in x-ray micro-computed tomography images for a high density thin wall metallic cylinder containing micro-EDM holes. Image quality was evaluated in terms of signal-to-noise ratio, flaw detectability, and feature sharpness. The variables included: day-to-day reproducibility, current, integration time, voltage, filtering, number of frame averages, number of projection views, beam width, effective object radius, binning, orientation of sample, acquisition angle range (180deg to 360deg), and directional versus transmission tube.

X-ray Computed Tomography↗