Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Exploring wave propagation in heterogeneous metastructures using the relaxed micromorphic model

Metamaterials are artificial structures that can manipulate and control sound waves in ways not possible with conventional materials. While much effort has been undertaken to widen the bandgaps produced by these materials through design of heterogeneities within unit cells, comparatively little work has considered the effect of engineering heterogeneities at the structural scale by combining different types of unit cells. In this paper, we use the relaxed micromorphic model to study wave propagation in heterogeneous metastructures composed of different unit cells. We first establish the efficacy of the relaxed micromorphic model for capturing the salient characteristics of dispersive wave propagation through comparisons with direct numerical simulations for two classes of metamaterial unit cells: namely phononic crystals and locally resonant metamaterials. We then use this model to demonstrate how spatially arranging multiple unit cells into metastructures can lead to tailored and unique properties such as spatially-dependent broadband wave attenuation, rainbow trapping, and pulse shaping. In the case of the broadband wave attenuation application, we show that by building layered metastructures from different metamaterial unit cells, we can slow down or stop wave packets in an enlarged frequency range, while letting other frequencies through. In the case of the rainbow-trapping application, we show that spatial arrangements of different unit cells can be designed to progressively slow down and eventually stop waves with different frequencies at different spatial locations. Finally, in the case of the pulse-shaping application, our results show that heterogeneous metastructures can be designed to tailor the spatial profile of a propagating wave packet. Collectively, these results show the versatility of the relaxed micromorphic model for effectively and accurately simulating wave propagation in heterogeneous metastructures, and how this model can be used to design heterogeneous metastructures with tailored wave propagation functionalities.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation

Here, in this tutorial review, we discuss how the choice of upconversion pulse shape in broadband vibrational sum-frequency generation (SFG) spectrometer design impacts the chemical or physical insights one can obtain from a set of measurements. A time-domain picture of a vibrational coherence being mapped by a second optical field is described and the implications of how this mapping, or upconversion process, takes place are given in the context of several popular and emerging approaches found in the literature. Emphasis is placed on broadband frequency-domain measurements, where the choice of upconversion pulse enhances or limits the information contained in the SFG spectrum. We conclude with an outline for a flexible approach to SFG upconversion using pulse-shaping methods and a simple guide to design and optimize the associated instrumentation.

47 OTHER INSTRUMENTATION↗

First demonstration of improved yield with reduced adiabat in inertial confinement fusion implosions on the National Ignition Facility

Laser-driven, indirect-drive inertial confinement fusion (ICF) experiments at the National Ignition Facility (NIF) recently achieved a target gain greater than one, where fusion energy output exceeds input laser energy [Abu-Shawareb et al., Phys. Rev. Lett. 132, 065102 (2024)]. Despite this milestone, gain levels remain insufficient for practical applications such as inertial fusion energy, making performance improvement critical. One promising approach is increasing fuel compression by lowering the implosion adiabat. To explore reduced adiabat, experiments were conducted modifying the laser pulse shape and shock timing of an existing 1.9-MJ-drive implosion design performing near the ignition cliff [Abu-Shawareb et al., Phys. Rev. Lett. 129, 075001 (2022)]. These experiments demonstrated increased compression and fusion yield in ICF implosions at the NIF by using a lower fuel adiabat, and increased compression with a reduced adiabat in high-density carbon ablators. The updated design achieved up to 80% higher fusion yield and 14% greater fuel compression compared to the previous best-performing 1.9-MJ experiment, with repeatable performance, and is the only implosion design to achieve a target gain exceeding one with < 2.04 MJ laser energy. Notably, this work was made possible because of recent advances in target quality and pulse shape control allowing experimental access to the ignition regime, and thereby increased sensitivity to adiabat. This work addresses a long-standing question in ICF research and lays the foundation for higher target gains through optimized implosion strategies. It underscores the potential of reduced adiabat designs to enhance compression and fusion yields for future ICF applications.

Hohenberger, M. [Lawrence Livermore National Labor↗

Dynamics of implosion, bounce, and re-implosion of a shell directly driven by a time-shaped laser pulse

Gas-filled plastic spherical shells have been imploded using the 60-beam OMEGA laser. The same laser pulse was used as in a previous experiment, which demonstrated the dynamic formation of a shell by irradiating a homogeneous plastic foam sphere. In the present experiment, the shell initially implodes, bounces, and expands; a new shell then forms and undergoes a second implosion. Analysis of x-ray self-emission-streaked images and sequences of 2D x-ray self-emission framing camera images show shell evolution that is in reasonable agreement with 1D simulations. Shell integrity and symmetry are well maintained until the formation of the new shell. The final implosion, instead, is affected by substantial asymmetries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Behavior of soda-lime silicate glass under laser-driven shock compression up to 315 GPa

Shock experiments give a unique insight into the behavior of matter subjected to extremely high pressures and temperatures. Understanding the behavior of materials under such extreme conditions is key to modeling material failure and deformation dynamics under impact. While studies on pure silica are extensive, the shock behavior of other commercial silicates that contain additional oxides has not been systematically investigated. To better understand the role of composition in the dynamic behavior of silicates, we performed laser-driven dynamic compression experiments on soda-lime glass (SLG) up to 315 GPa. Using the accurate pulse shaping offered by the long pulse laser system at the Matter in Extreme Conditions end-station at the Linac Coherent Light Source, SLG was shock compressed along the Hugoniot to multiple pressure-temperature points. Velocity Interferometer System for Any Reflector was used to measure the velocity and determine the pressure inside the SLG. The U s –u p relationship obtained agrees well with the previous parallel plate impact studies. Within the error bars, no transformation to the crystalline phase was observed up to 70 GPa, which is in contrast to the behavior of pure silica under shock compression. Our studies show that the glass composition strongly influences the shock compression behavior of the silicate glasses.

36 MATERIALS SCIENCE↗

Ultranarrow bandwidth pulses from a regeneratively mode-locked fiber laser

We report on the generation of transform-limited nanosecond pulse with an ultranarrow bandwidth from a regeneratively mode-locked erbium-doped fiber laser. A narrow bandwidth fiber Bragg grating is combined with a bulk amplitude electro-optic modulator to shape pulse evolution inside a ring cavity, and regenerative mode locking is applied to produce a stationary shape of pulses in the nanosecond regime (2.05 ns in duration). Spectral characterization via high bandwidth optoelectronic devices shows that optical pulses have an ultranarrow bandwidth of 220 MHz. Numerical simulation reveals that the shape of the narrow spectral filter has a strong effect on the duration and bandwidth of output pulses.

43 PARTICLE ACCELERATORS↗

Identifying Interaction Location in SuperCDMS Detectors

The Super Cryogenic Dark Matter Search (SuperCDMS) experiment uses silicon and germanium particle detectors operated at temperatures of ∼ 30 mK to search for Weakly Interacting Massive Particles (WIMPs), which are candidate dark matter particles that interact weakly with nuclei in the detectors. In operating these detectors, it is required not only to measure the energy of the interaction between the WIMP and the nuclei, but also to reconstruct where the interaction occurred, as the location can be used to separate background interactions from signal and to correct for variations with the location of the energy response. In this project, we, as a team from the University of Minnesota, aim to address the problem of accurately reconstructing the locations of interactions in the SuperCDMS detectors using machine learning methods. The dataset we provided here includes interactions at thirteen different locations from test data taken at the University of Minnesota. For each interaction, a set of parameters was extracted from the signals from each of the five sensors. These parameters represent information known to be sensitive to interaction location, including the relative timing between pulses in different channels, and features like the pulse shape. The relative amplitudes of the pulses are also relevant but due to instabilities in amplification during the test, this data is not included. The parameters included for each interaction are described in our project document. For more details, feel free to check our Github page: https://fair-umn.github.io/FAIR-UMN-CDMS/

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of digital electronics for the search of SHE nuclei using GARIS-II/III at RIKEN

This work describes the implementation of a digital data acquisition system for the search and study of short-lived isotopes or superheavy elements at the GARIS-III separator at the RIKEN Nishina Center. Here a reduction to 26 ± 0.5 keV in the average value of the Full Width at Half Maximum of the alpha spectrum at 7.133 MeV was achieved, combined with a reduction of the dead time of the overall system to around a few tens of nanoseconds for the detection of very fast decay chains. Moreover, we measured a reduction of the background induced by particles crossing the implantation detector using pulse shape analysis techniques. The detail of the optimization and analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

6 Li-loaded liquid scintillators produced by direct dissolution of compounds in diisopropylnaphthalene (DIPN)

Here, this paper describes preparation of 6 Li-loaded liquid scintillators by methods involving direct dissolution of 6Li salts in the commercial diisopropylnaphthalene (DIPN) solvent, without the formation of water-in-oil emulsions. Methods include incorporation of 6 Li that, unlike previously reported formulations, does not require additions of water or a strong acid such as hydrochloric acid (HCl). Results of the conducted experiments show that dissolution of aromatic and aliphatic 6 Li salts in DIPN can be easily achieved at 0.1%–0.3% by weight of atomic 6 Li, using small additions of waterless surfactants, or mild carboxylic acids. An alternative way suggests incorporation of 6 Li as a part of a surfactant molecule that can be dissolved in DIPN without any solubilizing additions. Proposed methods enable preparation of efficient 6 Li-loaded liquid scintillators that, at a large scale of 50 cm, exhibit good pulse shape discrimination (PSD) properties combined with up to 107% of light output and up to 115% of the attenuation length measured relative to standard undoped EJ-309 liquid scintillator.

36 MATERIALS SCIENCE↗

Efficient Prompt Scintillation and Fast Neutron-Gamma Ray Discrimination Using Amorphous Blends of Difluorenylsilane Organic Glass and in-situ Polymerized Vinyltoluene

High performance radiation detection materials are an integral part of national security, medical imaging, and nuclear physics applications. Those that offer compositional and manufacturing versatility are of particular interest. In this work, we report a new family of radiological particle-discriminating scintillators containing bis(9,9-dimethyl-9H-fluoren-2- yl)diphenylsilane (compound “P2”) and in-situ polymerized vinyltoluene (PVT) that is phase stable and mechanically robust at any blend ratio. The gamma-ray light yield increases nearly linearly across the composition range, to ~16,400 photons/MeV at 75 % wt. P2. These materials are also capable of γ/n pulse shape discrimination (PSD) and between 20-50 % P2 loading are competitive with the PSD quality of commercially-available plastic scintillators. The 137 Cs scintillation rise and decay times are sensitive to P2 loading and approach the values for “pure” P2. Additionally, the radiation detection performance of P2-PVT blends can be made stable in 60°C air for at least 1.5 months with the application of a thin film of poly(vinylalcohol) to the scintillator surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Control of Energy Transport and Transduction in Photosynthetic Down-Conversion (Final Technical Report)

The research conducted under this contract focused on three areas related to control of energy transport and transduction in natural and synthetic light harvesting systems: (1) experimental and theoretical studies exploring the use of ultrafast laser pulse shaping to manipulate the initially excited states of multi-chromophore biological light harvesting networks and influence the early time energy transfer and electronic and vibrational relaxation pathways, (2) fundamental theoretical developments aimed at computing and analyzing the dynamics of excitations of complex heterogeneous environments and nano structures, and (3) joint experimental and theoretical design studies of artificial light harvesting materials exploring the influence of incorporating different types of organic layers in low dimensional lead halide perovskite materials on their hot carrier relaxation dynamics, and theoretical studies of the design of nano structured light harvesting antenna systems. These research projects supported the training of three theoretical and computational graduate students, one experimental graduate student, and one experimental post-doctoral researcher. The research has been published in seven peer reviewed papers and presented at several international meetings and workshops.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Imaging Using Organic Glass Scintillators

In this work, we develop of a compact neutron imaging system based on organic glass scintillator and silicon photomultiplier arrays. The recently developed organic glass scintillator has excellent neutron and gamma-ray detection efficiency and exhibits pulse shape discrimination capability that is nearly as good as current state-of-the-art materials such as trans-stilbene. We have cast and characterized 6 mm by 6 mm by 50 mm bars of organic glass in our laboratory. When coupled to a silicon photomultiplier array, these bars demonstrated better energy and timing resolution than the stilbene organic scintillator. Here, this performance makes organic glass an ideal material for a compact neutron imaging system, which must resolve neutron scatter events on a sub-nanosecond time scale. We have demonstrated neutron imaging with bars of organic glass scintillator coupled to arrays of silicon photomultipliers. Additional bars of organic glass will be implemented into the system to improve the efficiency and imaging performance. The resulting system will be demonstrated using 252 Cf and PuBe neutron sources in our laboratory. In addition, we will compare imaging performance to other compact neutron imaging systems that exist in literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗