Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A short static-pressure probe design for supersonic flow

A static-pressure probe design concept was developed which has the static holes located close to the probe tip and is relatively insensitive to probe angle of attack and circumferential static hole location. Probes were constructed with 10 and 20 deg half-angle cone tips followed by a tangent conic curve section and a tangent cone section of 2, 3, or 3.5 deg, and were tested at Mach numbers of 2.5 and 4.0 and angles of attack up to 12 deg. Experimental results indicate that for stream Mach numbers of 2.5 and 4.0 and probe angle of attack within + or - 10 deg, values of stream static pressure can be determined from probe calibration to within about + or - 4 percent. If the probe is aligned within about 7 deg of the flow experimental results indicated, the stream static pressures can be determined to within 2 percent from probe calibration.

Pinckney, S. Z.↗

Estimate of the probability of a lightning strike to the Galileo probe

Lightning strikes to aerospace vehicles occur mainly in or near clouds. As the Galileo entry probe will pass most of its operational life in the clouds of Jupiter, which is known to have lightning activity, the present study is concerned with the risk of a lightning strike to the probe. A strike to the probe could cause physical damage to the structure and/or damage to the electronic equipment aboard the probe. It is thought to be possible, for instance, that the instrument failures which occurred on all four Pioneer Venus entry probes at an altitude of 12 km were due to an external electric discharge. The probability of a lightning strike to the Galileo probe is evaluated. It is found that the estimate of a strike to the probe is only 0.001, which is about the same as the expected failure rate due to other design factors. In the case of entry probes to cloud-covered planets, a consideration of measures for protecting the vehicle and its payload from lightning appears to be appropriate.

Borucki, W. J.↗

Effect of Reynolds Number and Mach Number on flow angularity probe sensitivity

Preliminary calibrations were performed on nine flow angularity probes in the Langley 7- by 10-Foot High-Speed Tunnel (7 x 10 HST) and the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). These probes will be used in surveying the test section flows of the National Transonic Facility (NTF). The probes used in this study have a pyramid head with five pressure orifices. The calibrations consisted of both isolated probe measurements and rake-mounted multiprobe measurements that covered a range of subsonic Mach numbers up to 0.90 and Reynolds numbers per foot up to 40 X 10 to the 6th power. The preliminary calibration in the 7 x 10 HST included testing the probes both individually and in a rake. The 0.3-m TCT calibration tested two probes singly at varying Reynolds numbers. The results from these tests include Mach number, Reynolds number, and rake-mounting effects. The results of these tests showed probe sensitivity to be slightly affected by Mach number. At Reynolds numbers per foot above 10 x 10 to the 6th power, the probe did not exhibit a Reynolds number sensitivity.

Smith, L. A.↗

Development of subminiature multi-sensor hot-wire probes

Limitations on the spatial resolution of multisensor hot wire probes have precluded accurate measurements of Reynolds stresses very near solid surfaces in wind tunnels and in many practical aerodynamic flows. The fabrication, calibration and qualification testing of very small single horizontal and X-array hot-wire probes which are intended to be used near solid boundaries in turbulent flows where length scales are particularly small, is described. Details of the sensor fabrication procedure are reported, along with information needed to successfully operate the probes. As compared with conventional probes, manufacture of the subminiature probes is more complex, requiring special equipment and careful handling. The subminiature probes tested were more fragile and shorter lived than conventional probes; they obeyed the same calibration laws but with slightly larger experimental uncertainty. In spite of these disadvantages, measurements of mean statistical quantities and spectra demonstrate the ability of the subminiature sensors to provide the measurements in the near wall region of turbulent boundary layers that are more accurate than conventional sized probes.

Westphal, Russell V.↗

Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

Lagen, Nicholas T.↗

Plasma gradient effets on doubel-probe measurements in the magnetosphere

The effects on double-probe electric field measurements induced by electron density and temperature gradients are investigated. We show that on some occasions such gradients may lead to marked spurious electric fields if the probes are assumed to lie at the same probe potential with repect to the plasma. The use of a proper bias current will decrease the magnitude of such an error. When the probes are near the plasma potential, the magnitude of these error signals, delta Epsilon, can vary as delta Epsilon approx. T(sub e)(Delta n(sub e)/n(sub e)) + 0.5 Delta T(sub e), where T(sub e) is the electron temperature, Delta n(sub e)/ n(sub e) the relative electron density variation between the two sensors, and Delta T(sub e) the electron temperature difference between the two sensors. This not only implies that the error signals will increase linearly with the density variations but also that such signatures grow with Delta T(sub e) i.e., such effects are 10 times larger in a 10-eV plasma than in a 1-eV plasma. This type of error is independent of the probe separation distance provided the gradient scale length is much larger than the distance. The largest errors occur when the probes are near to the plasma potential. During the crossing of a small structure (e.g, a double layer) the error signal appears as a bipolar signature. Our analysis shows that errors in double-probe measurements caused by plasma gradients are not significant at large scale (much greater than 1 km) plasma boundaries, and may only be important in cases where small-scale (less than 1 km), internal gradient structures exist. Bias currents tailored for each plasma parameter regime (i.e., variable bias current) would improve the double-probe response to gradient effects considerably.

Laakso, Harri↗

Factors Influencing Pitot Probe Centerline Displacement in a Turbulent Supersonic Boundary Layer

When a total pressure probe is used for measuring flows with transverse total pressure gradients, a displacement of the effective center of the probe is observed (designated Delta). While this phenomenon is well documented in incompressible flow and supersonic laminar flow, there is insufficient information concerning supersonic turbulent flow. In this study, three NASA Lewis Research Center Supersonic Wind Tunnels (SWT's) were used to investigate pitot probe centerline displacement in supersonic turbulent boundary layers. The relationship between test conditions and pitot probe centerline displacement error was to be determined. For this investigation, ten circular probes with diameter-to-boundary layer ratios (D/delta) ranging from 0.015 to 0.256 were tested in the 10 ft x 10 ft SWT, the 15 cm x 15 cm SWT, and the 1 ft x 1 ft SWT. Reynolds numbers of 4.27 x 10(exp 6)/m, 6.00 x 10(exp 6)/in, 10.33 x 10(exp 6)/in, and 16.9 x 10(exp 6)/m were tested at nominal Mach numbers of 2.0 and 2.5. Boundary layer thicknesses for the three tunnels were approximately 200 mm, 13 mm, and 30 mm, respectively. Initial results indicate that boundary layer thickness, delta, and probe diameter, D/delta play a minimal role in pitot probe centerline offset error, Delta/D. It appears that the Mach gradient, dM/dy, is an important factor, though the exact relationship has not yet been determined. More data is needed to fill the map before a conclusion can be drawn with any certainty. This research provides valuable supersonic, turbulent boundary layer data from three supersonic wind tunnels with three very different boundary layers. It will prove a valuable stepping stone for future research into the factors influencing pitot probe centerline offset error.

Grosser, Wendy I.↗

Langmuir-Probe Measurements in Flowing-Afterglow Plasmas

The validity of the orbital-motion theory for cylindrical Langmuir probes immersed in flowing- afterglow plasmas is investigated experimentally. It is found that the probe currents scale linearly with probe area only for electron-collecting but not for ion-collecting probes. In general, no agreement is found between the ion and electron densities derived from the probe currents. Measurements in recombining plasmas support the conclusion that only the electron densities derived from probe measurements can be trusted to be of acceptable accuracy. This paper also includes a brief derivation of the orbital-motion theory, a discussion of perturbations of the plasma by the probe current, and the interpretation of plasma velocities obtained from probe measurements.

Johnsen, R.↗

NASA SMART Probe: Breast Cancer Application

There is evidence in breast cancer and other malignancies that the physiologic environment within a tumor correlates with clinical outcome. We are developing a unique percutaneous Smart Probe to be used at the time of needle biopsy of the breast. The Smart Probe will simultaneously measure multiple physiologic parameters within a breast tumor. Direct and indirect measurements of tissue oxygen levels, blood flow, pH, and tissue fluid pressure will be analyzed in real-time. These parameters will be interpreted individually and collectively by innovative neural network techniques using advanced intelligent software. The goals are 1) develop a pecutaneous Smart Probe with multiple sensor modalities and applying advanced Information Technologies to provide real time diagnostic information of the tissue at tip of the probe, 2) test the percutaneous Smart Probe in women with benign and malignant breast masses who will be undergoing surgical biopsy, 3) correlate probe sensor data with benign and malignant status of breast masses, 4) determine whether the probe can detect physiologic differences within a breast tumor, and its margins, and in adjacent normal breast tissue, 5) correlate probe sensor data with known prognostic factors for breast caner, including tumor size, tumor grade, axillary lymph node metastases, estrogen receptor and progesterone receptor status.

Mah, Robert W.↗

Detection of Fatigue Cracks at Rivets with Self-Nulling Probe

A new eddy current probe developed at NASA Langley Research Center has been used to detect small cracks at rivets in aircraft lap splices [1]. The device has earlier been used to detect isolated fatigue cracks with a minimum detectable flaw size of roughly 1/2 to 1/3 the diameter of the probe [2]. The present work shows that the detectable flaw size for cracks originating at rivets can be greatly improved upon from that of isolated flaws. The use of a rotating probe method combined with spatial filtering has been used to detect 0.18 cm EDM notches, as measured from the rivet shank, with a 1.27 cm diameter probe and to detect flaws buried under the rivet head, down to a length of 0.076 cm, using a 0.32 cm diameter probe. The Self-Nulling Electromagnetic Flaw Detector induces a high density eddy current ring in the sample under test. A ferromagnetic flux focusing lens is incorporated such that in the absence of any inhomogeneities in the material under test only a minimal magnetic field will reach the interior of the probe. A magnetometer (pickup coil) located in the center of the probe therefore registers a null voltage in the absence of material defects. When a fatigue crack or other discontinuity is present in the test article the path of the eddy currents in the material is changed. The magnetic field associated with these eddy currents then enter into the interior of the probe, producing a large output voltage across the pickup coil leads. Further

Wincheski, Buzz↗

Synergy Between probes and Orbiter

There are many ways in which the science return from a planetary mission is considerably enhanced by interactions between entry probes and a mission orbiter. Mission configuration aspects that are desirable include delivery of entry probes by the orbiter, and communication between probe and orbiter. Both of these mission aspects could greatly enhance access to key scientific sites that might not otherwise be accessible using delivery from say, a flyby, or employing direct communication from probes to Earth. Examples for Venus and Jupiter will be discussed. A second class of orbiter-probe interaction could better be termed direct probe-orbiter science collaboration. That would include, determining the global context of the entry probe sites from the orbiter, obtaining ground truth from the probe for remote sensing observations from the orbiter, observing the global and vertical distribution of key atmospheric trace species, and measuring the global and vertical distribution of clouds and winds. The importance of each of these items will be illustrated by particular examples.

Young, Richard E.↗

High-Temperature Probe Station Developed to Characterize Microwave Devices Through 500 C

A photograph and a block diagram of the high-temperature probe station are shown. The system consists of the ceramic heater mounted on a NASA shuttle tile insulator, a direct current power supply, a personal-computer-based data acquisition and temperature controller, microwave probes, a microscope, and a network analyzer. The ability to perform microwave tests at high temperatures is becoming necessary. There is now a need for sensors and communication circuits that can operate at 500 C and above for aircraft engine development and monitoring during flight. To address this need, researchers have fabricated devices using wide bandgap semiconductors such as SiC with targeted operating temperatures of 500 to 600 C. However, the microwave properties of these devices often change drastically with temperature, so any designs that are intended to be used in such an environment must be characterized at high temperatures. For some reliability, lifetime, and direct-current testing, the device under test can be packaged and characterized in an oven. However, for RF and microwave measurements, it is usually not possible to establish a calibrated reference plane at the device terminals within a package. In addition, the characteristics of the package would vary over a 500 C temperature range, and this would have to be accounted for when the data were analyzed. A high temperature probe station allows circuits and devices to be characterized through on wafer measurements across a broad temperature range with known reference plane. The conventional, commercially available thermal wafer-probe stations that are used to evaluate microwave devices across a controlled temperature range have a typical upper limit of 200 C. Standalone thermal heating chucks are available with an extended upper temperature range of 300 to 400 C. To effectively characterize devices at temperatures up to and surpassing 500 C, Glenn researchers developed a custom probe station. In the past, custom probe stations have been developed to test devices under other extreme environments, such as cryogenic temperatures as low as 37 K. Similarly, this custom probe station was specifically modified for high-temperature use. It allows devices to be measured quickly and flexibly, without the use of wire bonds and test fixtures. The probe station is shown making scattering parameter measurements from 1 to 50 GHz with a Hewlett-Packard 8510C Network Analyzer. There is a half-wafer of silicon directly on top of the heater to provide a uniform heated platform for our sample. A quarter wafer of silicon carbide forms the substrate for our test circuit of several transmission lines.

Downey, Alan N.↗

Method for nanoscale spatial registration of scanning probes with substrates and surfaces

Embodiments in accordance with the present invention relate to methods and apparatuses for aligning a scanning probe used to pattern a substrate, by comparing the position of the probe to a reference location or spot on the substrate. A first light beam is focused on a surface of the substrate as a spatial reference point. A second light beam then illuminates the scanning probe being used for patterning. An optical microscope images both the focused light beam, and a diffraction pattern, shadow, or light backscattered by the illuminated scanning probe tip of a scanning probe microscope (SPM), which is typically the tip of the scanning probe on an atomic force microscope (AFM). Alignment of the scanning probe tip relative to the mark is then determined by visual observation of the microscope image. This alignment process may be repeated to allow for modification or changing of the scanning probe microscope tip.

Wade, Lawrence A.↗

Inspecting Friction Stir Welding using Electromagnetic Probes

A report describes the use of advanced electromagnetic probes to measure the dimensions, the spatial distribution of electrical conductivity, and related other properties of friction stir welds (FSWs) between parts made of the same or different aluminum alloy(s). The probes are of the type described in in another Tech Brief. To recapitulate: A probe of this type is essentially an eddy-current probe that includes a primary (driver) winding that meanders and multiple secondary (sensing) windings that meander along the primary winding. Electrical conductivity is commonly used as a measure of heat treatment and tempering of aluminum alloys, but prior to the development of these probes, the inadequate sensitivity and limited accuracy of electrical-conductivity probes precluded such use on FSWs between different aluminum alloys, and the resolution of those probes was inadequate for measurement of FSW dimensions with positions and metallurgical properties. In contrast, the present probes afford adequate accuracy and spatial resolution for the purposes of measuring the dimensions of FSW welds and correlating spatially varying electrical conductivities with metallurgical properties, including surface defects.

Kinchen, David G.↗

Nanoscale Hot-Wire Probes for Boundary-Layer Flows

Hot-wire probes having dimensions of the order of nanometers have been proposed for measuring temperatures (and possibly velocities) in boundary-layer flows at spatial resolutions much finer and distances from walls much smaller than have been possible heretofore. The achievable resolutions and minimum distances are expected to be of the order of tens of nanometers much less than a typical mean free path of a molecule and much less than the thickness of a typical flow boundary layer in air at standard temperature and pressure. An additional benefit of the small scale of these probes is that they would perturb the measured flows less than do larger probes. The hot-wire components of the probes would likely be made from semiconducting carbon nanotubes or ropes of such nanotubes. According to one design concept, a probe would comprise a single nanotube or rope of nanotubes laid out on the surface of an insulating substrate between two metallic wires. According to another design concept, a nanotube or rope of nanotubes would be electrically connected and held a short distance away from the substrate surface by stringing it between two metal electrodes. According to a third concept, a semiconducting nanotube or rope of nanotubes would be strung between the tips of two protruding electrodes made of fully conducting nanotubes or ropes of nanotubes. The figure depicts an array of such probes that could be used to gather data at several distances from a wall. It will be necessary to develop techniques for fabricating the probes. It will also be necessary to determine whether the probes will be strong enough to withstand the aerodynamic forces and impacts of micron-sized particles entrained in typical flows of interest.

Tedjojuwono, Ken T.↗

Hands-Free Transcranial Color Doppler Probe

Current transcranial color Doppler (TCD) transducer probes are bulky and difficult to move in tiny increments to search and optimize TCD signals. This invention provides miniature motions of a TCD transducer probe to optimize TCD signals. The mechanical probe uses a spherical bearing in guiding and locating the tilting crystal face. The lateral motion of the crystal face as it tilts across the full range of motion was achieved by minimizing the distance between the pivot location and the crystal face. The smallest commonly available metal spherical bearing was used with an outer diameter of 12 mm, a 3-mm tall retaining ring, and 5-mm overall height. Small geared motors were used that would provide sufficient power in a very compact package. After confirming the validity of the basic positioning concept, optimization design loops were completed to yield the final design. A parallel motor configuration was used to minimize the amount of space wasted inside the probe case while minimizing the overall case dimensions. The distance from the front edge of the crystal to the edge of the case was also minimized to allow positioning of the probe very close to the ear on the temporal lobe. The mechanical probe is able to achieve a +/-20deg tip and tilt with smooth repeatable action in a very compact package. The enclosed probe is about 7 cm long, 4 cm wide, and 1.8 cm tall. The device is compact, hands-free, and can be adjusted via an innovative touchscreen. Positioning of the probe to the head is performed via conventional transducer gels and pillows. This device is amendable to having advanced software, which could intelligently focus and optimize the TCD signal.

Chin, Robert↗

Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas

A model of current collection in Langmuir probes is used to investigate the effect representative non- equilibrium plasmas under various conditions have on the electron temperature and number density that would be calculated through analysis of the probe collection characteristics. The model uses the distribution function to calculate the charged particle flux to a probe and then, for fixed applied voltages, the current values that satisfy continuity in the probes are determined. The triple probe is not scanned in voltage, so there is no practical way using experimental triple probe data to determine if the plasma is in equilibrium. As a consequence, a triple probe analysis typically relies on the assumption that the plasma is in equilibrium. Proceeding from this point, the numerically-generated non-equilibrium triple probe data are analyzed assuming that the plasma is in equilibrium, with the data compared to the initial distribution function inputs of plasma temperature and number density to determine the effect the non-equilibrium distribution has on plasma measurements. The temperature and number density are both significantly affected when a fraction of the particles in the distribution are shifted from the equilibrium configuration into the non-equilibrium part of the distribution function. For all instances studied, the computed electron temperature and number density are extremely sensitive to small deviations from equilibrium ( ≤ 5% of the plasma shifted into the non-equilibrium function). Shifting more of the plasma into the non-equilibrium distribution beyond this initial level does not produce a significant additional shift in the computed plasma properties.

Polzin, Kurt A.↗

Heatshield for Extreme Entry Environment Technology (Heeet) and 3D Woven TPS Readiness for Outer Planet Probe Missions

Recent mission studies have shown entry at Uranus or at Neptune will require 3-D Woven TPS, either the two-layer HEEET or the single layer 3MDCP, with 3MDCP being more mass efficient. The 3MDCP capability being developed to support MSR EES is sufficient for the Ice Giants if the probe size is 1.25 m or less. [The Uranus Orbiter Probe (UOP) Flagship study for the Decadal used a 1.26m diameter probe.] For larger diameters, dual layer HEEET is easily scalable and is already at TRL 6. It is possible to develop a seam approach that would allow the use of 3MDCP; the resultant mass savings could warrant such a development. Ames is already working on a concept towards this. If aerocapture becomes part of the mission design for Uranus, delivery of the probe from orbit will be easier. Whether or not the probe is delivered from orbit, 3-D Woven (HEEET or 3MDCP) is the only TPS qualified to enable Ice Giant in situ probes. In addition to UOP, Saturn probe mission concepts will be enabled by 3-D Woven, either HEEET or 3MDCP. Launch periods for the UOP flagship or a Saturn probe mission in the early to mid 2030s requires the community to ensure that the 3D woven capability does not atrophy. Currently other than MSR EES, no other mission requires 3-D wovens, and the manufacturing for MSR will be completed by 2023. A gap in production of 5 or more years requires careful monitoring of the industrial base. In addition, manufacturing of 3-D woven TPS, from procurement and weaving to molding and infusion, is a minimum 2-year activity. In response to the threat of atrophy and the time critical and intensive nature of restarting weaving, advocacy from OPAG to NASA SMD for a sustainability effort would ensure in situ exploration of the outer planets in the decades to come.

M Gasch↗