Engineering PapersSearch

SEARCH · Engineering Papers

Results for “probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Air Data Probe Anomalies in Flight through Measured High Ice Water Content Conditions

High concentrations of ice crystals in convective storms have caused anomalous air temperature and airspeed readings during commercial and research flight operations. These anomalies occur when ice crystals are ingested in the heated probe inlet, melt or partially melt to liquid water, and then refreeze or remain in a liquid state depending on the probe heat and cloud conditions. In pitot probes, the refreezing may cause complete blockage of the total pressure, which causes airspeed anomalies. In total air temperature probes, the melted ice water may flow near the temperature sensing element and cause the total air temperature reading to approach 0 degree Celsius. During the High Ice Water Content (HIWC) RADAR and HIWC-2022 flight campaigns and the Convective Process Experiment (CPEX-CV) flight campaign, a total of 71 anomalies were recorded on the NASA DC-8 pitot probes when subjected to specific flight and cloud conditions. Similarly, a research TAT probe mounted near the pitot probes had 19 anomalies. This paper presents analyses of the measured natural conditions that led to these TAT and pitot anomalies, identifies two types of pitot probe anomalies, applies a concentration factor to estimate local TWC conditions near the TAT and pitot probes, and identifies the static air temperature and pressure altitude where the anomalies occurred on the Part 33 Appendix D envelope.

Aircraft Icing

Air Data Probe Anomalies in Flight through Measured High Ice Water Content Conditions

High concentrations of ice crystals in convective storms have caused anomalous air temperature and airspeed readings during commercial and research flight operations. These anomalies occur when ice crystals are ingested in the heated probe inlet, melt or partially melt to liquid water, and then refreeze or remain in a liquid state depending on the probe heat and cloud conditions. In pitot probes, the refreezing may cause complete blockage of the total pressure, which causes airspeed anomalies. In total air temperature probes, the melted ice water may flow near the temperature sensing element and cause the total air temperature reading to approach 0 degree Celsius. During the High Ice Water Content (HIWC) RADAR and HIWC-2022 flight campaigns and the Convective Process Experiment (CPEX-CV) flight campaign, a total of 71 anomalies were recorded on the NASA DC-8 pitot probes when subjected to specific flight and cloud conditions. Similarly, a research TAT probe mounted near the pitot probes had 19 anomalies. This paper presents analyses of the measured natural conditions that led to these TAT and pitot anomalies, identifies two types of pitot probe anomalies, applies a concentration factor to estimate local TWC conditions near the TAT and pitot probes, and identifies the static air temperature and pressure altitude where the anomalies occurred on the Part 33 Appendix D envelope.

Aircraft Icing

The Interplay of Pauli Repulsion, Electrostatics, and Field Inhomogeneity for Blueshifting and Redshifting Vibrational Probe Molecules

Many molecules' vibrational frequencies are sensitive to intermolecular electric fields, enabling them to probe the field in complex molecular environments. However, it is often unclear whether the probe is responding to the local electric field or other types of intermolecular interactions, inhibiting interpretation of the frequency and effectiveness as probes. This is especially true for molecules whose vibrational frequencies blueshift instead of the more typical redshift in hydrogen bonding configurations. In this work, we computationally investigate the causes of redshifting versus blueshifting over a range of vibrational reporters. First, we apply adiabatic energy decomposition analysis to a paradigmatic set of probes, finding that redshifting only occurs when electrostatic interactions are strong enough to overcome the dominant and large blueshifting contribution of Pauli repulsion. Furthermore, we demonstrate that field inhomogeneity can further shift the frequency of many probes substantially to either reinforce or counteract the shift expected from a homogeneous field. We find that redshifting is reinforced by electric field inhomogeneity, otherwise field inhomogeneity further weakens the electrostatic contribution relative to Pauli repulsion, leading to blueshifting. Further calculations indicate that the probe's response to field inhomogeneity can be understood by considering the mass of the atoms involved in the stretching mode and sign of the electric field. In explaining the interplay of different intermolecular interactions and field inhomogeneity for many probes, our results should enable the use and interpretation of spectroscopic probes and their connection to electric fields in more complex systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

New model for the ion collection by cylindrical probes over a wide range of collisionality

Langmuir probes remain one of the most important diagnostic tools for plasma processing applications. Modern probe analysis usually relies on the electron current part of the Langmuir probe characteristic using the Druyvesteyn method. However, for electronegative plasmas or for discharges containing dust the analysis of the ion current attracted by the probe can be desirable to determine the ion density. But, even at low pressures of a few Pa, the ion current is affected by collisions due to the large cross section for charge exchange. Available theories for collisional or collision-enhanced ion currents onto probes are complex and not well validated. Thus, in this contribution, we compare available collisional probe theories for the ion current to results of particle-in-cell (PIC) simulations. To this end, the probe surrounded by a semi-infinite plasma is simulated using a modified version of the open-source code EDIPIC. A dataset of currents for different neutral gas pressures is obtained and compared to the different theories from the literature. Based on these results, we propose a simpler and more intuitive model for the ion current collected by the probe, based on the model of Gatti and Kortshagen (Phys. Rev. E 78, 046402, 2008), developed for the charging of dust particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Wind Tunnel PSD and MVD Characterization Using New 1D2D Optical Array Probes

This work explores characterization of the liquid clouds using a combination of a forward scattering probe and two Optical Array Probes. Current OAP probes provide particle shape, size, and number concentration from two-dimensional shadow images. However, past studies have shown that such images are subject to distortion when outside of the focal plane. This affects the retrieval of particle size distributions, particularly in the Supercooled Large Droplet size range. In this article, the use of a Droplet Measurement Technologies Cloud Droplet Probe and two new OAPs produced by Science Engineering Associates, is examined using wind tunnel data, to assess suitability for use in a wind tunnel calibration in SLD conditions. The new OAP probes exploit a flexible and simple grey scale imaging method to eliminate some present shortcomings of commonly used OAPs, and to reduce correction factors. Spinning disk measurements were used to specify probe depth of field, and average size errors. Composite spectra covering the nominal 2-3200 µm size range were formed by crossing over from the CDP to 1D2D-X at 48 µm, and then to the 1D2D-Y at about 400 µm. A good overlap was found at the crossover points without any artificial scaling. Composite spectra adequately closed the liquid water content distribution, and provided integrated LWCs within about 35% of the hot-wire LWCs used for tunnel calibration. This discrepancy was at least partially attributed to LWC underestimation by the hot-wire at high MVD. A model of probe performance was used to show an example of expected accuracy of ideal probes subject to the same OAP distortions and using the same mitigating procedures and corrections, predicting PSD Median Volume Diameter and integrated LWC errors of less than 10%.

Aircraft Icing

Some implications of satellite spin effects in cylindrical probe measurements

In-situ measurements of ambient electron densities with satellite-borne cylindrical probes exhibit periodic variations synchronous with the satellite's spin cycle. Representing these fluctuations as a superposition of effects attributable to both the presence of the satellite wake and the geomagnetic field leads to a model of the modulations of accelerated electron current to cylindrical probes in which one modulation component displays current variations dependent upon the probe-velocity angle (psi) and the other displays variations dependent upon the angle between the probe axis and the geomagnetic field lines (beta). The modulations produce an electron current decrease whenever the probe axis rotates into the satellite wake or whenever the probe axis rotates toward alignment with the geomagnetic field lines. With increasing altitude, the modulation dependent upon psi decreases whereas the modulation dependent upon beta increases. The analysis results imply that the most accurate of atmospheric electron densities by satellite-borne cylindrical probes come from measurements taken out of the satellite's wake and when the probe axis is within 20 degrees of being perpendicular to the geomagnetic field lines.

Miller, N. J.

Evaluation of a self-aspirating local total enthalpy probe in a low-density arc-heated hypersonic wind tunnel

A shock-swallowing, self-aspirating, local total enthalpy probe has been evaluated in a low density nonequilibrium, hypervelocity airstream. The probe, which incorporated an air gap to separate the internal and external cooling passages, was tested in an electric archeated wind tunnel at an average Mach number of 11.7 and an average Reynolds number per meter of 57,000. The free stream enthalpy probe data are compared with bulk calorimeter measurements of total enthalpy at the beginning of the gas expansion and with local total enthalpy inferred from a theoretical nonequilibrium gas expansion model by using free stream velocity measurements obtained from a mass flow probe. The three techniques are in relative agreement at the lower enthalpies. However, at the higher enthalpies, the enthalpy probe data lie considerably below the other data. This low data may be caused by the chemical and vibrational energy frozen in the flow not being sensed by the probe. Other problems associated with the shock-swallowing total enthalpy probe are discussed, and recommendations for improving the probe performance are presented.

Guy, R. W.

Some implications of satellite spin effects in cylindrical probe measurements.

Observation that in situ measurements of ambient electron densities with satellite-borne cylindrical probes exhibit periodic variations synchronous with the satellite spin cycle. Representing these fluctuations as a superposition of effects attributable to both the presence of the satellite wake and the geomagnetic field leads to a model of the modulations of accelerated electron current to cylindrical probes in which one modulation component displays current variations dependent on the probe velocity angle (psi), and the other displays variations dependent on the angle between the probe axis and the geomagnetic-field lines (beta). The modulations produce an electron current decrease whenever the probe axis rotates into the satellite wake or whenever the probe axis rotates toward alignment with the geomagnetic-field lines. As altitude increases, the modulation dependent on psi decreases, whereas the modulation dependent on beta increases. The psi-dependent modulation component can be associated with the presence of a wake structure, and the beta-dependent component can be associated with the magnetic influence on the transport properties of thermal electrons, assuming that the electron fluxes are predominant along the field lines. The analysis results imply that the most accurate determinations of atmospheric electron densities by satellite-borne cylindrical probes come from measurements taken out of the wake of the satellite when the probe axis is within 20 deg of being perpendicular to the geomagnetic-field lines.

Miller, N. J.

Effects of Mach number on pitot-probe displacement in a turbulent boundary layer

Experimental pitot-probe-displacement data have been obtained in a turbulent boundary layer at a local free-stream Mach number of 4.63 and unit Reynolds number of 6.46 million meter. The results of this study were compared with lower Mach number results of previous studies. It was found that small probes showed displacement only, whereas the larger probes showed not only displacement but also distortion of the shape of the boundary-layer profile. The distortion pattern occurred lower in the boundary layer at the higher Mach number than at the the lower Mach number. The maximum distortion occurred when the center of the probe was about one probe diameter off the test surface. For probes in the wall contact position, the indicated Mach numbers were, for all probes tested, close to the true profile. Pitot-probe displacement was found to increase significantly with increasing Mach number.

Allen, J. M.

A short static-pressure probe design for supersonic flow

A static-pressure probe design concept was developed which has the static holes located close to the probe tip and is relatively insensitive to probe angle of attack and circumferential static hole location. Probes were constructed with 10 and 20 deg half-angle cone tips followed by a tangent conic curve section and a tangent cone section of 2, 3, or 3.5 deg, and were tested at Mach numbers of 2.5 and 4.0 and angles of attack up to 12 deg. Experimental results indicate that for stream Mach numbers of 2.5 and 4.0 and probe angle of attack within + or - 10 deg, values of stream static pressure can be determined from probe calibration to within about + or - 4 percent. If the probe is aligned within about 7 deg of the flow experimental results indicated, the stream static pressures can be determined to within 2 percent from probe calibration.

Pinckney, S. Z.

Estimate of the probability of a lightning strike to the Galileo probe

Lightning strikes to aerospace vehicles occur mainly in or near clouds. As the Galileo entry probe will pass most of its operational life in the clouds of Jupiter, which is known to have lightning activity, the present study is concerned with the risk of a lightning strike to the probe. A strike to the probe could cause physical damage to the structure and/or damage to the electronic equipment aboard the probe. It is thought to be possible, for instance, that the instrument failures which occurred on all four Pioneer Venus entry probes at an altitude of 12 km were due to an external electric discharge. The probability of a lightning strike to the Galileo probe is evaluated. It is found that the estimate of a strike to the probe is only 0.001, which is about the same as the expected failure rate due to other design factors. In the case of entry probes to cloud-covered planets, a consideration of measures for protecting the vehicle and its payload from lightning appears to be appropriate.

Borucki, W. J.

Effect of Reynolds Number and Mach Number on flow angularity probe sensitivity

Preliminary calibrations were performed on nine flow angularity probes in the Langley 7- by 10-Foot High-Speed Tunnel (7 x 10 HST) and the Langley 0.3-Meter Transonic Cryogenic Tunnel (0.3-m TCT). These probes will be used in surveying the test section flows of the National Transonic Facility (NTF). The probes used in this study have a pyramid head with five pressure orifices. The calibrations consisted of both isolated probe measurements and rake-mounted multiprobe measurements that covered a range of subsonic Mach numbers up to 0.90 and Reynolds numbers per foot up to 40 X 10 to the 6th power. The preliminary calibration in the 7 x 10 HST included testing the probes both individually and in a rake. The 0.3-m TCT calibration tested two probes singly at varying Reynolds numbers. The results from these tests include Mach number, Reynolds number, and rake-mounting effects. The results of these tests showed probe sensitivity to be slightly affected by Mach number. At Reynolds numbers per foot above 10 x 10 to the 6th power, the probe did not exhibit a Reynolds number sensitivity.

Smith, L. A.

Development of subminiature multi-sensor hot-wire probes

Limitations on the spatial resolution of multisensor hot wire probes have precluded accurate measurements of Reynolds stresses very near solid surfaces in wind tunnels and in many practical aerodynamic flows. The fabrication, calibration and qualification testing of very small single horizontal and X-array hot-wire probes which are intended to be used near solid boundaries in turbulent flows where length scales are particularly small, is described. Details of the sensor fabrication procedure are reported, along with information needed to successfully operate the probes. As compared with conventional probes, manufacture of the subminiature probes is more complex, requiring special equipment and careful handling. The subminiature probes tested were more fragile and shorter lived than conventional probes; they obeyed the same calibration laws but with slightly larger experimental uncertainty. In spite of these disadvantages, measurements of mean statistical quantities and spectra demonstrate the ability of the subminiature sensors to provide the measurements in the near wall region of turbulent boundary layers that are more accurate than conventional sized probes.

Westphal, Russell V.

Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

Lagen, Nicholas T.

Plasma gradient effets on doubel-probe measurements in the magnetosphere

The effects on double-probe electric field measurements induced by electron density and temperature gradients are investigated. We show that on some occasions such gradients may lead to marked spurious electric fields if the probes are assumed to lie at the same probe potential with repect to the plasma. The use of a proper bias current will decrease the magnitude of such an error. When the probes are near the plasma potential, the magnitude of these error signals, delta Epsilon, can vary as delta Epsilon approx. T(sub e)(Delta n(sub e)/n(sub e)) + 0.5 Delta T(sub e), where T(sub e) is the electron temperature, Delta n(sub e)/ n(sub e) the relative electron density variation between the two sensors, and Delta T(sub e) the electron temperature difference between the two sensors. This not only implies that the error signals will increase linearly with the density variations but also that such signatures grow with Delta T(sub e) i.e., such effects are 10 times larger in a 10-eV plasma than in a 1-eV plasma. This type of error is independent of the probe separation distance provided the gradient scale length is much larger than the distance. The largest errors occur when the probes are near to the plasma potential. During the crossing of a small structure (e.g, a double layer) the error signal appears as a bipolar signature. Our analysis shows that errors in double-probe measurements caused by plasma gradients are not significant at large scale (much greater than 1 km) plasma boundaries, and may only be important in cases where small-scale (less than 1 km), internal gradient structures exist. Bias currents tailored for each plasma parameter regime (i.e., variable bias current) would improve the double-probe response to gradient effects considerably.

Laakso, Harri

Factors Influencing Pitot Probe Centerline Displacement in a Turbulent Supersonic Boundary Layer

When a total pressure probe is used for measuring flows with transverse total pressure gradients, a displacement of the effective center of the probe is observed (designated Delta). While this phenomenon is well documented in incompressible flow and supersonic laminar flow, there is insufficient information concerning supersonic turbulent flow. In this study, three NASA Lewis Research Center Supersonic Wind Tunnels (SWT's) were used to investigate pitot probe centerline displacement in supersonic turbulent boundary layers. The relationship between test conditions and pitot probe centerline displacement error was to be determined. For this investigation, ten circular probes with diameter-to-boundary layer ratios (D/delta) ranging from 0.015 to 0.256 were tested in the 10 ft x 10 ft SWT, the 15 cm x 15 cm SWT, and the 1 ft x 1 ft SWT. Reynolds numbers of 4.27 x 10(exp 6)/m, 6.00 x 10(exp 6)/in, 10.33 x 10(exp 6)/in, and 16.9 x 10(exp 6)/m were tested at nominal Mach numbers of 2.0 and 2.5. Boundary layer thicknesses for the three tunnels were approximately 200 mm, 13 mm, and 30 mm, respectively. Initial results indicate that boundary layer thickness, delta, and probe diameter, D/delta play a minimal role in pitot probe centerline offset error, Delta/D. It appears that the Mach gradient, dM/dy, is an important factor, though the exact relationship has not yet been determined. More data is needed to fill the map before a conclusion can be drawn with any certainty. This research provides valuable supersonic, turbulent boundary layer data from three supersonic wind tunnels with three very different boundary layers. It will prove a valuable stepping stone for future research into the factors influencing pitot probe centerline offset error.

Grosser, Wendy I.

Langmuir-Probe Measurements in Flowing-Afterglow Plasmas

The validity of the orbital-motion theory for cylindrical Langmuir probes immersed in flowing- afterglow plasmas is investigated experimentally. It is found that the probe currents scale linearly with probe area only for electron-collecting but not for ion-collecting probes. In general, no agreement is found between the ion and electron densities derived from the probe currents. Measurements in recombining plasmas support the conclusion that only the electron densities derived from probe measurements can be trusted to be of acceptable accuracy. This paper also includes a brief derivation of the orbital-motion theory, a discussion of perturbations of the plasma by the probe current, and the interpretation of plasma velocities obtained from probe measurements.

Johnsen, R.

NASA SMART Probe: Breast Cancer Application

There is evidence in breast cancer and other malignancies that the physiologic environment within a tumor correlates with clinical outcome. We are developing a unique percutaneous Smart Probe to be used at the time of needle biopsy of the breast. The Smart Probe will simultaneously measure multiple physiologic parameters within a breast tumor. Direct and indirect measurements of tissue oxygen levels, blood flow, pH, and tissue fluid pressure will be analyzed in real-time. These parameters will be interpreted individually and collectively by innovative neural network techniques using advanced intelligent software. The goals are 1) develop a pecutaneous Smart Probe with multiple sensor modalities and applying advanced Information Technologies to provide real time diagnostic information of the tissue at tip of the probe, 2) test the percutaneous Smart Probe in women with benign and malignant breast masses who will be undergoing surgical biopsy, 3) correlate probe sensor data with benign and malignant status of breast masses, 4) determine whether the probe can detect physiologic differences within a breast tumor, and its margins, and in adjacent normal breast tissue, 5) correlate probe sensor data with known prognostic factors for breast caner, including tumor size, tumor grade, axillary lymph node metastases, estrogen receptor and progesterone receptor status.

Mah, Robert W.