Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A High-Fidelity Electromagnetic Transient Model of Inverter-based Resources Integrated to an IEEE-9 Bus System for Benchmarking Studies

An inverter-based resource (IBR) is a source of electricity that is asynchronously connected to the electrical grid via an electronic power converter. These power sources lack the intrinsic behaviors of the standard power plants, presenting specific challenges to system stability. These power sources lack the intrinsic behaviors of the standards power plants and their features are almost entirely defined by the control strategy used on them, presenting specific challenges to system stability as their penetration increases into the already fragile Bulk Power System (BPS). Utilizing renewable energy has a great upside but the electrical industry needs to understand the requirements like performing electromagnetic transient (EMT) simulation studies in planning and/or in interconnection studies. This paper presents the development of a high-fidelity EMT model based on commercial equipment and field parameters, which at the same time aims to study the increasing penetration of IBRs and their impact on the actual BPS. The open-source EMT model developed will be a benchmarking example that can be used to evaluate algorithms in the power grid (including evaluating grid-forming controls, power system monitoring and operation, etc.).

Martinez Montejano, Misael↗

A Comparison of Machine Learning Methods for Frequency Nadir Estimation in Power Systems: Preprint

An increasing penetration level of inverter-based renewable energy resources changes the inertia of power systems, posing challenges for maintaining the desired system frequency stability. An accurate frequency nadir estimation is crucial for power system operators to prepare preventive actions against large frequency excursions. In this paper, five machine learning methods - linear regression, gradient boosting, support vector regression, an artificial neural network, and XGBoost - are applied to two different sets of preprocess data for the prediction of the frequency nadir in the Western Electricity Coordinating Council 240-bus system with high renewable penetration levels. The training and testing data sets are collected by extensive generation scheduling simulations on the Multi-timescale Integrated Dynamic and Scheduling (MIDAS) toolbox. Numerical results show that all five machine learning methods can achieve high performance accuracy for power system nadir frequency estimation. Among them, the gradient boosting and the XGBoost are clear winners by providing the best prediction accuracy.

data driven↗

Toluene stability Space Station Rankine power system

A dynamic test loop is designed to evaluate the thermal stability of an organic Rankine cycle working fluid, toluene, for potential application to the Space Station power conversion unit. Samples of the noncondensible gases and the liquid toluene were taken periodically during the 3410 hour test at 750 F peak temperature. The results obtained from the toluene stability loop verify that toluene degradation will not lead to a loss of performance over the 30-year Space Station mission life requirement. The identity of the degradation products and the low rates of formation were as expected from toluene capsule test data.

Havens, V. N.↗

A Stability Analysis Tool for Bulk Power Systems Using Black-Box Models of Inverter-Based Resources

This paper presents a small-signal stability analysis tool for large-scale power systems with high penetration of inverter-based resources (IBRs). Firstly, a network transfer function matrix (NTFM), which represents the information of the system topology, transmission lines, loads, IBRs locations, etc., is derived to model the entire power system network. Secondly, small-signal perturbation method is applied to obtain the sequence impedance/admittance models of the block-box IBRs considering the frequency cross-coupling effects. With the obtained NTFM as well as IBR models, a multi-input, multi-output (MIMO) feedback system is constructed, and the generalized Nyquist criterion (GNC)-based stability method is employed to analyze the stability of the entire power system. Furthermore, based on the developed stability analysis method, sensitivity analysis is conducted on an unstable case to identify which parameter has a high impact on the system stability. As a result, different test cases based on a modified IEEE 14- bus system as well as a reduced 240-bus WECC system are studied to verify the proposed stability analysis tool.

42 ENGINEERING↗

Implementational Aspects for the Characterization of Low-Inertia in Power Systems

The replacement of conventional generating units with non-conventional renewable energy resources impacts the stability of the power system. While the general goal of supplying demand could be achieved from both generation resources, inverter-based energy resources are different from traditional synchronous machines in the sense that they do not inherently provide inertia to the system. The latter obviously worsen the system ability to maintain the balance between supply and demand after certain contingencies such as generator outages. With high integration of renewable-based generation resources, there is a reduction in total system inertia, which could lead to systems with less time to react for frequency restoration in case of such unexpected unit failures. While conceptually it is true, there is a missing gap in the field of power system stability community in terms of test-bed power systems for characterizing low-inertia conditions. In this paper, a framework for low-inertia power systems is presented. The purpose of the test-bed is to establish an environment for testing and conducting research on power systems experiencing low-inertia issues. The frequency nadir, the rate of change of frequency, and the under-frequency load shedding scheme are used as a measure of the healthiness of power grids.

Baquedano-Aguilar, Mario D.↗

A Stability Analysis Tool for Bulk Power Systems Using Black-Box Models of Inverter-based Resources

This paper presents a small-signal stability analysis tool for large-scale power systems with high penetration of inverter-based resources (IBRs). Firstly, a network transfer function matrix (NTFM), which represents the information of the system topology, transmission lines, loads, IBRs locations, etc., is derived to model the entire power system network. Secondly, small-signal perturbation method is applied to obtain the sequence impedance/admittance responses of IBRs considering the frequency cross-coupling effects. With the obtained NTFM as well as IBRs' models, a multi-input, multi-output (MIMO) feedback system is constructed, and the generalized Nyquist criterion (GNC)-based stability method is employed to analyze the stability of the entire power system. Different testing cases based on a modified IEEE-14 bus system are leveraged to verify the proposed stability analysis tool.

Sun, Dongsen↗

Efficient Region of Attraction Characterization for Control and Stabilization of Load Tap Changer Dynamics

In this article, we study the monitoring and control of long-term voltage stability considering load tap changer (LTC) dynamics. We show that under generic conditions, the LTC dynamics admit a unique stable equilibrium. For the stable equilibrium, we characterize an explicit inner approximation of its largest region of attraction (ROA). Compared to existing results, the computational complexity of the ROA characterization is drastically reduced. We propose a quadratically constrained linear program formulation for the ROA characterization problem. In addition, we formulate a second-order cone program for online voltage stability monitoring and control exploiting the proposed ROA characterization. Finally, we demonstrate the efficacy of the proposed formulations on the ROA characterization and stability monitoring and control using a standard IEEE test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Reinforcement Learning-Based Control of Energy Storage for Interarea Oscillation Damping

With the increasing electricity consumption and lack of transmission investment, today's power systems are operated much closer to their limits, raising concerns of inter-area oscillations that deteriorate the system stability. Here, this article presents a novel energy storage placement and control approach for enhanced damping of interarea oscillations. Combining the residual analysis and dominant mode analysis, we are able to identify the advantageous locations for placing energy storage that achieve improved damping performance. To overcome the challenges, such as fixed control parameters and insufficient damping, we propose to use a deep reinforcement learning-based approach for energy storage control. A state-of-the-art guided surrogate-gradient-based evolutionary strategy is used to train a learning agent in a robust, efficient, and reproducible manner. Parallel computing is also adopted to speed up the training process. The proposed strategy has been tested on both medium and large-scale systems. The proposed methods have demonstrated their effectiveness in mitigating various interarea oscillations within a timeframe of 20 s, thereby averting system collapse and enhancing power grid stability effectively.

25 ENERGY STORAGE↗

Physics-Informed Evolutionary Strategy Based Control for Mitigating Delayed Voltage Recovery

Here, in this work we propose a novel data-driven, real-time power system voltage stability control method based on the physics-informed guided meta evolutionary strategy (ES). The main objective is to quickly provide an adaptive control strategy to secure system voltage stability. The problem is challenging due to the high-dimensional feature of the power system model and the fast-changing and uncertain nature of power system operation scenarios. To this end, a model-free and derivative-free guided ES method is applied. The method is further combined with a meta-learning strategy to make the learnt control policy automatically adapted to unseen operation conditions and fault scenarios, which is highly desired for real-time emergency control. Last but not least, physical knowledge is embedded in the above method through a trainable action mask technique to rule out unnecessary load shedding actions for better learning and control performance. Case studies on the IEEE 300-bus system and comparisons with other state-of-the-art benchmark methods verify the superiority of the proposed physics-informed guided meta ES method in realizing fast and adaptive power system voltage stability control.

42 ENGINEERING↗

Modelling and control coordination scheme of a wind‐to‐hydrogen set for future renewable‐based power systems

New challenges regarding system stability and efficiency arise when power systems operate with a high penetration level of inverter‐based renewable sources (IBRSs) and few synchronous generators. Since IBRSs have been on the rise, to secure the stable operation of future power systems, IBRSs will be required to support systems without having to rely on remaining synchronous generators. Also, to efficiently manage the uncertainty of renewable production, power‐to‐gas technology can provide the required flexibility. This study proposes modelling and a control coordination scheme (CCS) of a wind‐to‐hydrogen (W2H) set to optimise electricity production from a variable‐speed wind turbine generator (WTG) while helping balance between supply and demand in a system. To achieve this, a grid‐forming (GFM) inverter‐based WTG is modelled and a set of electrolyser and fuel cell is integrated at the DC circuit of a GFM‐WTG to be coordinated. Furthermore, the CCS offers an opportunity to reduce the investment cost for deploying a W2H set by utilising the control capabilities of a WTG and reducing the need for an additional device. The performance of the proposed W2H set with the CCS was verified considering the variations in system load and wind speed by using Power System Computer Aided Design (PSCAD)/ElectroMagnetic Transients including Direct Current (EMTDC).

Kim, Jinho↗

Demonstration of Grid Services Using Mixed Grid-Forming and Grid-Following Technologies at the Wheatridge Renewable Energy Facility (Final Technical Report)

This Final Technical Report summarizes the analytical, modeling, and engineering work performed to evaluate grid-forming (GFM) inverter capabilities within a large hybrid renewable energy facility. The project focused on assessing the ability of advanced inverter-based resources to provide essential reliability services through coordinated operation of grid-forming (GFM) and grid-following (GFL) technologies. During Budget Period 1, the project developed a comprehensive framework of GFM performance metrics, including angle support, voltage regulation, frequency response, damping behavior, and current-limiting performance. Extensive electromagnetic transient (EMT) studies and hardware-in-the-loop (HIL) testing were conducted to validate GFM behavior under a range of operating conditions, including weak-grid scenarios, voltage disturbances, and multi-resource interactions. The project also established validated modeling approaches, plant-level control integration strategies, commissioning frameworks, and high-speed measurement infrastructure to support future field demonstration. Although the project concluded prior to field demonstration, the results provide a utility-scale foundation for evaluating, modeling, and deploying grid-forming technologies. The methodologies and tools developed contribute to industry understanding of inverter-based resource behavior and support future power system reliability under increasing renewable penetration.

14 SOLAR ENERGY↗

Quantifying System Strength From Grid-Forming Resources Using Frequency Scan Approach: Preprint

Current industry practices for quantifying the system strength contribution from grid-forming (GFM) resources to ensure stability of power systems dominated by inverter-based resources (IBRs) are primarily based on iterative electromagnetic transient (EMT) time-domain simulation studies. While feasible, these approaches are resource-intensive, lack scalability and intuition, and might not evaluate the system strength contribution over the entire frequency range of interest. This paper introduces a novel, frequency-domain approach to quantify system strength support provided by a GFM resource using frequency scans. The proposed method uses transfer functions from the grid voltage magnitude (V) and phase (?), respectively, to the reactive (Q) and active power (P) output of a GFM resource for quantifying its contribution to system strength. These transfer functions provide a direct measure of the ability of a GFM resource to behave as a stiff voltage source behind a reactance over a specified frequency range, enabling robust quantification of its system strength contribution. The key innovation of this work is the development of a frequency domain system strength metric called the dynamic short-circuit ratio (dSCR) that is suitable for IBR-dominated power systems and is directly related with the familiar short circuit ratio (SCR) metric. The new metric, dSCR, enables the assessment of system strength contributions from both synchronous machines and converter-based GFM resources using a unified benchmark, which is not possible with the traditional SCR metric. The paper also demonstrates how impedance scans could identify if an unstable condition observed during weak grid conditions is a result of the lack active or reactive power support or both. By leveraging the proposed frequency-domain dSCR metric for quantifying system strength contribution from GFM IBRs, the paper demonstrates targeted mitigation strategies for weak grid instabilities without resorting to repeated, time-consuming time-domain simulations. The result is a scalable and efficient approach to remediate stability challenges in power systems with high shares of IBRs and accelerating the integration of GFM technologies for system strength support in power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Forming Inverters for Stability Improvements in Bulk Power Systems with High Inverter-Based Resources Penetration

The grid-forming inverter (GFM) has been considered recently as a means to enhance grid stability in areas with Inverter-based Resources (IBRs) concentration. This paper assesses the potential improvements the GFM can bring to Bulk-power Systems (BPS) through two distinct studies. The first study was conducted on West Texas in ERCOT with presence of more than 35GW of IBRs, the Grid-Following (GFL) batteries were replaced with GFM batteries. The results demonstrate that the GFM significantly improved the voltage profile and active power injection during and after a fault. The second study focused on a local area within ERCOT grid. In this case, a battery operating as GFL within the local study area was replaced with a GFM battery. The findings clearly illustrate that GFM can strengthen the area and allow a higher IBRs power generation and a higher power export from the local study area.

Quedan, Amro↗

Stabilize High-IBR Power Systems with Grid-Forming Inverters

The increasing share of IBRs challenges the stable operation of our power systems. Leveraging an oscillation event in Kaua`i Island as an example, we showcase the root cause of this event and highlight the potential of grid-forming inverters to reduce the stability risks in high-IBR power systems.

grid-forming inverters↗