Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Probabilistic Zonal Reserve Requirements for Improved Energy Deliverability with Wind Power

In power systems with high penetration of renewable energy resources, uncertainty and variability of these stochastic resources introduce additional challenges for the operation of power systems. To improve the power system's reliability in the face of uncertainty, reserves are required as additional generation capacity to rebalance the power system following random disturbances. However, reserve deliverability is not guaranteed, because it may encounter potential transmission line congestion. Zonal reserve requirements can address this issue, but operators lack efficient ways to allocate reserves to zones while accounting for wind power forecast uncertainty. Herein we propose a methodology for probabilistic zonal reserve requirements to address wind power forecast uncertainties. This method estimates the probability distribution of line flows based on the system generation margin and injection shift factor. This estimate is then used to construct pre-defined and post-zonal reserve requirements. Case studies demonstrate that the proposed method efficiently schedules energy and reserves to balance energy and manage deliverability with wind power forecast uncertainty.We also discuss operational implications of the proposed method.

17 WIND ENERGY↗

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Redesigning capacity market to include flexibility via ramp constraints in high-renewable penetrated system

Capacity markets can co-exist alongside the energy and ancillary markets to ensure the medium-term and long-term supply adequacy by remunerating the generation resources for their availability. With the substantially increasing deployment of renewable generation, the system needs more flexibility to quickly mitigate the variability and uncertainty caused by the renewable generation. However, the present capacity market model does not differentiate the flexibility of generating units, so it might not give appropriate pricing signals to more flexible units that are usually more expensive. This is particularly important considering the increasing penetration levels of renewable generation on the electric grid, which increases the need for flexible units. This paper proposes a novel capacity market model considering flexibility requirement (FR) under the high penetration levels of renewable generation. Therefore, the proposed model can give the market-clearing price (MCP) for not only peak load generation capacity but also flexibility requirement. Thus, flexible units will tend to receive more economic incentives than non-flexible units. In the case studies, the profitability of different generation resources under the proposed capacity market model is analyzed and compared to the present capacity market model. The results show that the proposed method can maintain system reliability with regard to both peak load and flexibility requirement efficiently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High energy density picoliter-scale zinc-air microbatteries for colloidal robotics

The recent interest in microscopic autonomous systems, including microrobots, colloidal state machines, and smart dust, has created a need for microscale energy storage and harvesting. However, macroscopic materials for energy storage have noted incompatibilities with microfabrication techniques, creating substantial challenges to realizing microscale energy systems. Here, we photolithographically patterned a microscale zinc/platinum/SU-8 system to generate the highest energy density microbattery at the picoliter (10 −12 liter) scale. The device scavenges ambient or solution-dissolved oxygen for a zinc oxidation reaction, achieving an energy density ranging from 760 to 1070 watt-hours per liter at scales below 100 micrometers lateral and 2 micrometers thickness in size. The parallel nature of photolithography processes allows 10,000 devices per wafer to be released into solution as colloids with energy stored on board. Within a volume of only 2 picoliters each, these primary microbatteries can deliver open circuit voltages of 1.05 ± 0.12 volts, with total energies ranging from 5.5 ± 0.3 to 7.7 ± 1.0 microjoules and a maximum power near 2.7 nanowatts. We demonstrated that such systems can reliably power a micrometer-sized memristor circuit, providing access to nonvolatile memory. We also cycled power to drive the reversible bending of microscale bimorph actuators at 0.05 hertz for mechanical functions of colloidal robots. Additional capabilities, such as powering two distinct nanosensor types and a clock circuit, were also demonstrated. The high energy density, low volume, and simple configuration promise the mass fabrication and adoption of such picoliter zinc-air batteries for micrometer-scale, colloidal robotics with autonomous functions.

Robotics↗

Leveraging PHIL for Inverter Functionality Requirement Evaluation to Ensure a Reliable Grid

This presentation showcases NREL's ongoing research on advanced Multi-point Power Hardware-in-the-Loop (PHIL) systems, enabling comprehensive evaluation of interoperability, stability, and wide-area stability in complex power grids. Key features include high-power PHIL capabilities, seamless PHIL Interfaces for effortless Grid-Following (GFL) and Grid-Forming (GFM) mode switching, and advanced multi-domain PHIL/Controller Hardware-in-the-Loop (CHIL) capabilities for evaluating diverse technology mixes, facilitating rigorous testing and validation of emerging power systems for reliable integration, enhanced resilience, and optimal performance.

lab capabilities↗

Island Power Systems With High Levels of Inverter-Based Resources: Stability and Reliability Challenges

As many island power systems seek to integrate high levels of renewable energy, they face new challenges on top of the existing difficulties of operating an isolated grid. With their drastically declining cost, variable renewables, such as wind and photovoltaics (PVs), are increasingly being integrated into island grids to reduce the use of imported fuels. These deployments of renewable energy are dominated by PV and wind generators, which bring unique challenges of their own. While the integration issues span numerous timescales (from microseconds to many months), this article focuses on reliability and stability challenges on short timescales (microseconds to seconds). In other words, we seek to answer (to the extent that it is currently known) how to ensure the frequency and voltage stability in an island power system with very high instantaneous levels of wind and PVs. And because island power systems are often among the first to reach these very high instantaneous levels of wind and PV generation, we note that they are forging a path for larger interconnected power systems to follow.

41 EE - Solar Energy Technologies Office (EE-4S)↗

ByzSec — A Multi-layered Byzantine Resilient Architecture for Bulk Power System Protective Relays

Reliability, selectivity, and sensitivity are the fundamental attributes of any protection system, acting as the main drivers in the selection of schemes, and equipment. In high-voltage systems, microprocessor-based relays represent the industry’s preferred solution, providing engineers with a vast array of benefits. However, they remain vulnerable to cybersecurity events that may compromise their functionality. To help mitigate against potential cybersecurity risks, this paper presents a fault-tolerant, Byzantine Resilient (BR) architecture that significantly increases the cybersecurity attributes of a protection system while minimizing the amount of performance impacts and integration overheads introduced. The solution relies on an array of independent relays that utilize robust consensus methods (based on Spire [1], [2]) to ensure correct system behavior is achieved even when a relay has been compromised. Furthermore, the solution has been complemented with a custom-built Situational Awareness engine that can be used to detect and identify potential threats. The implemented solution has been developed in consultation with three hardware vendors and has been tested to comply with the performance requirements of a 345kV differential protection scheme (87T). The results indicate that the proposed architecture is a comprehensive solution that: supports the strict correctness and performance requirements of the bulk power grid while providing a cost-effective alternative that offers a seamless, long-term solution.

byzantine security, Fault Tolerant Application Sof↗

ICRH operations and experiments during the JET-ILW tritium and DTE2 campaigns

2021 has culminated with the completion of the JET-ILW DTE2 experimental campaign. This contribution summarizes Ion Cyclotron Resonance Heating (ICRH) operations from system and physics point of view. Improvements to the (ICRH) system, to operation procedures and to real time RF power control were implemented to address specific constraints from tritium and deuterium-tritium operations and increase the system reliability and power availability during D-T pulses. ICRH was operated without the ITER-Like Antenna (ILA) because water leaked from an in-vessel capacitor into the vessel on day-2 of the D-T campaign. Three weeks were required to identify and isolate the leak and resume plasma operations. Dedicated RF-Plasma Wall Interaction (PWI) experiments were conducted; tritium plasmas exhibit a higher level of Be sputtering on the outer wall and impurity content when compared to deuterium or hydrogen plasmas. The JET-DTE2 campaigns provided the opportunity to characterize ICRH schemes foreseen for the ITER operation, in the ITER like wall environment in ELMy H-mode scenarios aiming at maximizing fusion performance. The second harmonic tritium resonance heating and to a lesser extent minority 3He heating (ITER D-T ICRH reference schemes) lead to improved ion temperature and fusion performance when compared to hydrogen minority ICRH. However, these discharges suffered from a lack of stationarity and gradual impurity accumulation potentially because of a deficit of ICRH power when using JET antennas at lower frequencies. Fundamental deuterium ICRH was used in tritium-rich plasmas and with deuterium Neutral Beam Heating; this ICRH scheme proved to be very efficient boosting ion temperature and fusion performance in these plasmas.

Klepper, C. Christopher↗

Adversarial Attacks on Deep Neural Network-based Power System Event Classification Models

Online event classification is essential to strengthening the reliability of the power transmission system. Recently, deep learning based methods have achieved great success in numerous domains such as computer vision and natural language processing. Researchers began to adopt deep learning based methods to solve the power system event identification problem and achieved effective results. However, these previous works do not consider that deep learning models are vulnerable to adversarial attacks, potentially influencing real-world applications' reliability. In this paper, we adopt several adversarial attack mechanisms by adding tailored noise signal to the input Phasor Measurement Units (PMU) time series and make the deep learning model misclassify the power system event. This numerical study discloses that current state-of-the-art deep learning based power system event classifiers are extremely vulnerable to adversarial attacks, which may jeopardize the reliability of the power transmission system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis of Natural Gas Fuel Cell Plant Configurations

The United States (U.S.) Department of Energy (DOE) Office of Fossil Energy and Carbon Management (FECM) and the National Energy Technology Laboratory (NETL) have been pursuing the development of solid oxide fuel cell (SOFC) technology to enable future power generation systems that are consistent with the cornerstones of the DOE mission—to ensure America’s security and prosperity by addressing its energy and environmental challenges through transformative science and technology solutions. The U.S. DOE FECM SOFC Program is currently focused on the development of low-cost, highly efficient, and reliable SOFC power systems. NETL’s SOFC technology development roadmap is aligned with near-term market opportunities in the distributed generation sector to validate and advance the technology while paving the way for utility-scale (> 50 MW) natural gas and coal-derived synthesis gas-fueled applications via progressively larger system demonstrations. The present study represents a part of a series of system evaluations being developed at NETL to aid in prioritizing technological advances along research pathways to the realization of utility-scale SOFC systems, a transformational goal of the fuel cell program. In particular, the system performance of utility-scale natural gas fuel cell (NGFC) systems with and without carbon dioxide (CO 2 ) capture is presented. The objective of the study is to provide targeted research and development (R&D) guidance to the FECM SOFC Program and SOFC commercial developers to accelerate technology deployment.

03 NATURAL GAS↗

Hydroclimate-coupled framework for assessing power system resilience under summer drought and climate change

Extreme drought, exacerbated by climate change, increasingly threatens power system resilience, and a systematic assessment of such impacts is challenging due to the unpredictability of drought and their associated modeling complexity. Here, to address the challenge, this research develops a hydroclimate-coupled power system resilience assessment framework that enables systematic modeling of drought and climate change impacts on generation, transmission, and demand sectors. Applying the framework to the 2025 Eastern U.S. power grid — comprising 6,055 at-risk generators — under climate-induced summer drought scenarios (including SSP126, SSP245, SSP370, and SSP585) from 2023 to 2100, the study finds that climate-induced droughts could jeopardize the power system’s reliability to a greater extent than historical events, potentially leading to widespread load shedding. More specifically, the study reveals that under the twenty-one representative drought scenarios, the loss of load expectation (LOLE) of the grid could range from 34.77 to 91.48 days per summer. The simulations indicate that implementing resilience enhancement strategies is crucial to ensure reliable system operation, which encompasses initiatives such as demand response, upgrading open cooling systems, and transmission expansion. In all, these findings underscore the urgent need for proactive planning and investment in resilient U.S. power systems to mitigate the impacts of extreme drought events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid-Forming Inverter-Based Resource Research Landscape: Understanding the Key Assets for Renewable-Rich Power Systems

The shift to net zero energy systems has changed the face of our power grid. Traditional large-scale synchronous generators found inside coal and natural gas plants are being replaced with inverter-based resource (IBR) technologies. This transition to an IBR-dominant power grid introduces new characteristics, altering how our grid operates. Therefore, the role of IBRs has expanded, requiring them to provide a range of essential services to keep our grid reliable, resilient, and secure.

energy management↗

Impact of Wildfires on Solar Resource Availability in California in a Changing Climate

Wildfires can emit large amounts of atmospheric particulate matters and influence not only air quality but also availability of photovoltaic (PV) generation due to scattering and absorption of solar radiation. Under anthropogenic changing climate, wildfire activity is projected to increase over western North America due to drier and warmer climate, implying increasing impact on solar resource and larger uncertainty in solar generation especially in regions with faster PV penetration. This study focuses on quantifying the impact of wildfires on aerosol optical depth (AOD) and thus solar resource over California using National Solar Radiation Database (NSRDB), developed by the National Renewable Energy Laboratory (NREL). This assessment includes historical analysis and estimation of solar resource under wildfire scenarios (2020 wildfire and an enhanced wildfire scenario based on 2020 wildfires). Historical analysis for the period of July-October 2019/2020 (low/high fire activity period) shows that the averaged global horizontal irradiance (GHI) and direct normal irradiance (DNI) are reduced by about 30 and 90 W m-2 (5.6 and 15.3%), respectively, during high fire activity period. To create AOD dataset for enhanced fire scenario, 165% increase in burn area (in around 2050) is selected based on comprehensive literature review, which is further applied to the Fire INventory from NCAR (FINN) fire emission. WRF-Chem model with the enhanced FINN emissions is used to simulate and represent a preserving spatial distribution of burned areas and wildfire-emitted aerosols. Our initial analysis suggests that the"enhanced 2020 wildfire" AOD can increase by a factor of 1.3 - 2, which can significantly reduce solar irradiance and increase uncertainty in generation and reliability of power system in extreme wildfire events under a high solar penetration scenario. Overall, this study provides an estimate of the impacts of wildfires on solar resource to make informed decisions on reserve planning, generation scheduling, and reliability investments.

aerosol optical depth↗

Coordination of Networked Microgrids for Supporting Voltages of Bulk Power Systems

Active distribution system resources have the potential to support the bulk power system (BPS) during abnormal conditions, increasing reliability and resilience of power systems and end-use customers. This paper investigates for the first time the BPS voltage support provided by networked microgrids at the feeder level. A peer-to-peer (P2P) communication control framework is introduced to enable the coordination of multiple microgrids in a mixed ownership environment. This allows the microgrids to run a consensus algorithm (CA) to distributedly determine their own reactive power injections. Thus, the reactive power injection contribution is realized in a fair manner by having the same ratio of reactive power injection to the reactive power headroom for all microgrids. The CA implementation and performance within the P2P network framework are demonstrated on the IEEE 39-bus testcase system with 10 microgrids part of the distribution feeder assumed to be connected to one of the BPS buses.

Vu, Thanh Long↗

Roadmap for Advanced Power System Measurements

Conditions in the electric power grid are changing rapidly. Changes are driven, in particular, by the increased penetration of renewable resources in the generation mix. Part of the solution to dealing with the changing conditions is the better use of measurement systems, taking advantage of the better understanding of measurements that was heralded by digital technology. Another part of the solution is the communication of samples of the directly observable voltages and currents by means of continuous point-on-wave values. The increased bandwidth capability of such a system allows more complicated measurement models to be built at the point of use. Additional measurements and analyses can then be performed. This Roadmap hinges on these two aspects of measuring: improved measurements supported by high-bandwidth (raw data) communications. Following an introduction to the overall subject, the report explores the impact of what can be thought of as the digital revolution in measurement. In essence, that revolution has served to clarify ideas about measurement and is continuing to lead to improved processes. An extensive survey of the relevant literature was performed . Webinars were held to learn from the wider community of practitioners. Based on this information, a number of gaps were identified whose continued existence would hamper the solution of the challenges now facing measurement and communication in the power grid. The underlying value propositions are interoperability (presently not very satisfactory in many measurements); greater (and less challenging) adoption of distributed energy resources; and improved international competitiveness. Underlying all that, of course, is progress toward a more reliable and resilient power system. The identified gaps were addressed in four major thrusts: technology deployment and demonstration, education, instrumentation testing and standards, and analytical methods. For each of the thrusts, multiple goals are defined to guide the implementation. The thrusts were designed to close gaps and unlock high-value use cases. After discussing the literature review, gap analysis, high-value use cases, and research thrusts in chapters 2-5, the report culminates in chapter 6 with a roadmap that links each aspect together to form a unified plan. Developing a research portfolio aligned with this plan will ensure that advanced measurement systems are in place to support reliable operation of the power system as it modernizes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Energy Resources as an Equity Asset: Lessons Learned from Deployments in Disadvantaged Communities

For an Energy System to be truly equitable, it should provide affordable and reliable energy services to disadvantaged and underserved populations. Disadvantaged communities often face a combination of economic, social, health, and environmental burdens and may be geographically isolated (e.g., rural communities), which systematically limits their opportunity to fully participate in aspects of economic, social, and civic life.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CSR in the Probabilistic Resource Adequacy Suite (PRAS): Fast Interregional Transmission Models for Renewable Integration Studies

NREL's Probabilistic Resource Adequacy Suite (PRAS) was developed for use in renewable integration studies, to assess the resource adequacy of large interconnected power systems with potentially significant interregional transfers of power. This presentation provides an overview of the tool and the methods it uses to solve multi-regional transmission and storage dispatch problems in a computationally-efficient manner.

composite system reliability↗