Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system oscillation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Electrical Systems of Pumped Storage Hydropower Plants: Electrical Generation, Machines, Power Electronics, and Power Systems

Adjustable-speed (AS) pumped storage hydropower (PSH) technology has the potential to become a large, consistent contributor to grid stability enabling higher penetrations of wind and solar energy on the future U.S. power system. AS-PSH has high-value characteristics, such as fast response to provide ancillary services to the grid, because it is a power converter interface with the grid (like battery storage), but at the same time it has the energy content large enough to supply both short-term (seconds-to-minutes) and long-term (minutes-to-hours) of energy needs, like more conventional power plants. However, designs must be optimized to lower the capital expenditure (CapEx) and to provide a high-quality grid interface capability (e.g. power quality, ancillary service provider, fault-tolerant or fault ride-through capability), which is a primary factor in the acceptance of AS-PSH into a utility’s generation mix. This CapEx will be greatly affected by the cost savings associated with the civil structure, turbine design, power electronics, control systems, or unique generator designs. A holistic design must be considered to get a full picture of the benefits of the technology proposed. The AS-PSH can be controlled to reduce the impact of transient disturbance on a power system and at the same time can be controlled to minimized subsequent component fatigue and potential oscillation modes within the plant, with the overall impact in reducing the operational expenditures (OpEx).Generating clean power to meet standards such as Institute of Electrical and Electronics Engineers (IEEE) 519 and International Electrotechnical Commission (IEC) 1000-3-2 will be a continuing challenge. For many technology developers, however, improved AS-PSH technologies will become a key component of generator-storage systems of the future given the prospects of increased performance and decreasing costs, and the ever-increasing penetration of renewables (e.g wind power and solar power).

13 HYDRO ENERGY↗

Small Hydro Power Plants with Integrated BESS for Enhance Resiliency

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a black start- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFM controlled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of Power System Black Start with Hydropower Generator and Battery Energy Storage: Preprint

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a blackstart- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFMcontrolled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Locating the Source of Forced Oscillations in Transmission Power Grids

A forced oscillation event in power grids refers to a state where malfunctioning or abnormally operating equipment causes persisting periodic disturbances in the system. While power grids are designed to damp most perturbations during standard operations, some of them can excite normal modes of the system and cause significant energy transfers across the system, creating large oscillations thousands of miles away from the source. Localization of the source of such disturbances remains an outstanding challenge due to a limited knowledge of the system parameters outside of the zone of responsibility of system operators. Here, we propose a new method for locating the source of forced oscillations that addresses this challenge by performing a simultaneous dynamic model identification using a principled maximum likelihood approach. We illustrate the validity of the algorithm on a variety of examples where forcing leads to resonance conditions in the system dynamics. Our results establish that an accurate knowledge of system parameters is not required for a successful inference of the source and frequency of a forced oscillation. We anticipate that our method will find a broader application in general dynamical systems that can be well described by their linearized dynamics over short periods of time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Participation Factor-Based Approach for Defining the EMT Model Boundary for Power System Simulations with Inverter-Based Resources

The increasing penetration of inverter-based resources (IBRs) introduces new challenges to power system simulations, particularly with the emergence of fast electromagnetic transient (EMT) dynamics and sub-synchronous oscillations (SSO) that require time-consuming EMT simulations. To reduce the time cost for simulating a large-scale power grid with IBRs, this paper proposes a novel participation factor-based approach for defining a critical zone for detailed EMT modeling and simulations, which includes the IBRs, synchronous generators, and the network components participating significantly in simulated contingencies. Both model-based and response-based methods are introduced for the estimation of participation factors (PFs). The case study on the 240-bus Western Electricity Coordinating Council (WECC) system demonstrates that the EMT zone determined by the proposed approach can effectively capture power system dynamics involving IBRs.

EMT simulation↗

Impact of the Exciter and Governor Parameters on Forced Oscillations

In recent years, the frequency of forced oscillation events due to control system malfunctions or improper parameter settings has increased. Tuning the parameters of exciters and governor models is crucial for maintaining power system stability. Traditional simulation studies typically involve small transient disturbances or step changes to find optimal parameter sets, but existing optimization algorithms often fall short in fine-tuning for forced oscillations. Identifying the sensitive parameters within these control models is essential for ensuring stability during large, sustained disturbances. This study focuses on identifying these critical exciter and governor model parameters by analyzing their influence on sustained forced oscillations. Using Kundur’s two-area system, we analyze common exciter models such as SCRX, ESST1A, and AC7B, along with governor models like GAST, HYGOV, and GGOV1, utilizing PSS®E software version 34. Sustained forced oscillations are injected at generator-1 of area-1, with individual parameter changes dynamically simulated. By considering a local oscillation frequency of 1.4 Hz and an inter-area oscillation mode of 0.25 Hz, we analyze the impact of each parameter change on the magnitude and frequency of forced oscillations as well as on active and reactive power outputs. This novel approach highlights the most influential parameters of each tested model—such as exciter, governor, and turbine gains, as well as time constant parameters—on the impact of forced oscillations. Based on our findings, the sensitive parameters of each tested model are ranked. These would provide valuable insights for industry operators to fine-tune control settings during oscillation events, ultimately enhancing system stability.

42 ENGINEERING↗

Simultaneous Forward-Backward Prony Estimation

Power system dynamic stability can be evaluated through the analysis of transient oscillations that occur following significant system events. One of the earliest methods for this type of study is Prony analysis, which estimates the system's electromechanical modes. While previous studies have highlighted advantages of performing Prony analysis on data in the forward and backward directions, the proposed method does so simultaneously. As a result, signal poles corresponding to electromechanical modes can be distinguished from spurious poles more reliably. The method also produces a single mode estimate, where independent application in the forward and backward directions would produce two estimates for each mode. The method is validated using simulated and measured power system data.

Follum, James D.↗

A New Type of Weak Grid IBR Oscillations

This letter presents the discovery of a new type oscillations associated with inverter-based resources (IBRs) in weak grids. While typical weak grid oscillations become worse when the grid strength decreases and the power exporting level increases, this new type of oscillations appear when the grid becomes weaker and the power exporting level decreases. Electromagnetic transient (EMT) simulation results are presented, along with eigenvalue loci for a varying power. The notable signatures of such oscillations are also remarked. In further analysis, a feedback system consisting of two blocks is derived with one block associated with the phase-locked-loop (PLL) and the other associated with the rest of the system. Here, this feedback system quantitatively demonstrates why insufficient damping in the PLL may be an issue for stability. Open-loop analysis shows that a larger phase lag in angle tracking in the low-frequency range due to high power exporting level at the weak grid condition is beneficial to the open-loop poles introduced by the PLL. And this is the reason why such oscillations may appear when power is ramping down.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High efficiency compact microwave sources using electrostatic potential depression

In this article, we report theoretical and design studies on the application of an electrostatic potential depression (EPD) on two types of traditional microwave sources, the klystron and the inductive output tube (IOT), both operating in the UHF band. Additionally, the EPD is implemented by a section of the metallic beam pipe on which a direct current (dc) negative high voltage is applied. Inside the EPD section, the modulated electron beam develops into bunches over a very short longitudinal distance, indicating a possible design approach for a compact device. With the application of an EPD, the peak value of the first harmonic current in a microwave tube can be further increased compared to that in a conventional design, suggesting higher circuit efficiency. As the electron beam leaves the EPD section, the reacceleration of the beam provides a longitudinal cooling effect. With the addition of an EPD, circuit power extraction efficiency above 80% is achieved in both the modified design of the IOT and the novel conceptual circuit design of the klystron.

42 ENGINEERING↗

Comments on Control of Wave Energy Converters

The main objective of this letter is to consolidate the knowledge about the dynamics and control of oscillating-body wave energy converters (WECs). A number of studies have shown that control systems strongly affect power absorption; however, there remains a need for a concise and integrated explanation of the theoretical and practical implications that control can have on both performance and the broader WEC design process. This short letter attempts to fill this gap by presenting a discussion on the key practical aspects concerning the dynamics and control of oscillating-body WEC. In particular, the focus is on the choice of control models and a simple causal control scheme suitable for real-time implementation. To conclude, consideration is given to the effect of the power takeoff (PTO) on the maximization of electrical power, thus leading to the derivation of useful conditions for the control co-design of the PTO system.

42 ENGINEERING↗

Biofouling Analysis for Wave Energy Piston Design: CRADA 542 [Abstract only]

Triton System’s Wave Energy Converter (WEC) uses an oscillating water column approach to provide small scale power to ocean observing and navigational buoys. Biofouling and corrosion are a major concern for all ocean-deployed components, especially when mechanical motion is involved. Triton Systems will collaborate with PNNL to evaluate seals, materials, and component performance in a controlled biofouling test environment. Results from this testing will be used to improve seal design and material selection, mitigating risk of premature failure during open water testing and evaluation.

16 TIDAL AND WAVE POWER↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and power system stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It may mitigate the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Control Design of Passive Grid-Forming Inverters in Port-Hamiltonian Framework

This article presents a modified dispatchable virtual oscillator control approach for achieving the passivity of gridforming inverters (GFMs), without assuming constant voltage and constant frequency. The proposed control framework utilizes the Port-Hamiltonian (PH) based structure that mimics the behaviors of coupled harmonic oscillators, along with an energy ‘pumpingor-damping’ block and the Control by Interconnection (CbI) technique, to render the inverter passive. Once passivity is achieved, transient stability of the system will be guaranteed. The proposed control framework is composed of three loops: an outer power dispatching loop that generates the voltage and frequency references, a virtual oscillator loop that emulates the spontaneous synchronization of oscillators, and an inductor current loop that maintains lossless interconnection in PH systems. In conclusion, the study shows that the proposed control approach ensures the passivity of GFMs, facilitating the transient stability design of multi-inverter systems, as interconnections of passive systems remain passive and stable.

42 ENGINEERING↗

Inter-Area Oscillation Damping with Type-5 Wind Power Plant: Preprint

This paper investigates the potential of using brushless excitation (BLE) for not only riding through the fault but also to damp inter-area power oscillation with the help of a synchronous generator (SG) used in Type 5 Wind Power Plant (WPP). In BLE, an auxiliary synchronous generator (ASG) behaving like an exciter is coupled and driven by the rotor of the main SG. The BLE's field current's ASG is fed by two separate loops of the automatic voltage regulator (AVR) and Power System Stabilizer (PSS). The AVR system implements a control loop to regulate the generator terminal voltage, VT. For the PSS, the kinetic energy of the wind turbine is utilized according to the estimated rotational speed of the synchronous generator shaft of the SG. It mitigates the necessity of any curtailment of active power for damping. The effectiveness of the proposed control scheme is verified with a three-phase short circuit fault in a two-area power system.

brushless↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Dynamic Oscillation and Motion of Oil‐in‐Water Emulsion Droplets

The interplay of interfacial tensions on droplets results in a range of self‐powered motions that mimic those of living systems and serve as a tunable model to understand their complex non‐equilibrium behavior. Spontaneous shape deformations and oscillations are crucial features observed in nature but difficult to incorporate in synthetic artificial systems. Here, we report sessile oil‐in‐water emulsions that exhibit rapid oscillating behavior. The oscillations depend on the nature and concentration of the surfactant, the chemical composition of the oil, and the wettability of the solid substrate. The rapid changes in the contact angle per oscillation are observed using side‐view optical microscopy. We propose that the changes in the interfacial tension of the oil droplets is due to the partitioning of the surfactant into the oil phase and the movement of self‐emulsified oil out of the parent droplets giving rise to the rhythmic variation in droplet contact‐line. The ability to control and understand droplet oscillation can help model similar oscillations in out‐of‐equilibrium systems in nature and reproduce biomimetic behavior in artificial systems for various applications, such as microfluidic lab‐on‐a‐chip and adaptive materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Oscillation and Motion of Oil‐in‐Water Emulsion Droplets

Abstract The interplay of interfacial tensions on droplets results in a range of self‐powered motions that mimic those of living systems and serve as a tunable model to understand their complex non‐equilibrium behavior. Spontaneous shape deformations and oscillations are crucial features observed in nature but difficult to incorporate in synthetic artificial systems. Here, we report sessile oil‐in‐water emulsions that exhibit rapid oscillating behavior. The oscillations depend on the nature and concentration of the surfactant, the chemical composition of the oil, and the wettability of the solid substrate. The rapid changes in the contact angle per oscillation are observed using side‐view optical microscopy. We propose that the changes in the interfacial tension of the oil droplets is due to the partitioning of the surfactant into the oil phase and the movement of self‐emulsified oil out of the parent droplets giving rise to the rhythmic variation in droplet contact‐line. The ability to control and understand droplet oscillation can help model similar oscillations in out‐of‐equilibrium systems in nature and reproduce biomimetic behavior in artificial systems for various applications, such as microfluidic lab‐on‐a‐chip and adaptive materials.

Krishna Mani, Sanjana↗