Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system event”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Power System Resilience Metrics Augmentation for Critical Load Prioritization

One of the major goals of new grid operation regimes, such as transactive energy systems (TESs), is to make the power grid more resilient to withstand natural or man-made disasters and potential reliability events, and to continue to serve the maximum number of its customers. But it is a well-known fact to system operators that not all customers are the same. This implies that any discussion of TESs’ impacts on the resilience of the power system should consider the needs of its critical customers (such as the power system operation centers, fire and police stations, and hospitals) over those of other customers. When evaluating the resilience of the system, bonus points must be awarded to any system that could maintain its power supply to critical customers during a disturbance that may cause an outage. This report discusses critical infrastructure (CI) as found in the literature and then categorizes it based on the field to which the operations belong (such as human life/safety-related, operations management, necessary city operation, industrial customers, etc.). Each of these CI categories is further divided into types of critical customers (e.g., the human life/safety-related category has different types of customers like hospitals, fire and police stations, etc.). The entire demand of each of the critical customer types is not categorized as critical load (CL); instead, only a portion of the total load of these critical customers is characterized as critical load. This is done based on the categories of equipment, the function of which is crucial in the operation of the overall facility. CL categorization is performed to provide the ratio of the critical load portion to the overall load , so that it can serve as a parameter in the resilience evaluation of the grid through a metrics-based approach. Such categorization is important as it helps to augment the existing quantifiable resilience metrics with CL categorization. The metrics for a power system need to not only consider how well a system performed during a disturbance event, but also how it reduced strain and supplied power to its CLs. The first step in this process is characterize CLs in the system. After CL characterization, the next step is the inclusion of these loads in the resilience metrics. To that end, in this report weight-based augmentation of resilience metrics is proposed, where certain customers (the ones that are categorized as critical) are assigned higher weights than others. Though an overview of assigning weights to customers is discussed, there is no one-size-fits-all approach for every power system. The decisions made about assigning such weights to customers vary greatly from one operator to another, based on their unique systems and the current and predicted states of critical customers. This decision-making can include the type of disturbance event, which might only affect certain parts of the system. In general, analyzing critical customers before an event helps understand system vulnerabilities. It also helps in planning and conducting operations during the event, evaluating system performance after the event, and supporting better planning for future events. An alternative to the current practices of managing the grid for outages is an innovative TES, which has the potential to provide a platform for including distributed energy resources for managing CLs. This report also describes how TES qualities can help (1) to maintain power supply to critical customers for uninterrupted operations and (2) to restore lost power supply to the critical customers rapidly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power System Resilience Enhancement in Typhoons Using a Three-Stage Day-Ahead Unit Commitment

In this work, we propose a three-stage resilient unit commitment model which considers uncertain typhoon paths and line outages to improve the power system resilience against typhoon events. The proposed solution coordinates resources in response to the worst-case scenario for each possible typhoon path. The optimal decision is based on the characterization of the power system schedule into three stages of preventive control, emergency control, and restoration. Preventive control is performed before the typhoon occurs by quickly adjusting the three-stage resilient unit commitment schedule; emergency control is conducted during the typhoon by shedding local loads to meet the power balance, while other control strategies are assumed to be unavailable due to possible interruptions in the communication system; restoration is realized after the typhoon, when resources are optimally dispatched to repair the outages of critical devices and recover the normal operation state of the power system quickly. Considering the typhoon path uncertainty, we have introduced a stochastic model for possible typhoon paths where all possible affected lines along each typhoon path are assumed to be on outage during the typhoon. Accordingly, we explore the strategy for co-optimizing the three stages in unit commitment. The proposed model is tested on the IEEE 118-bus system and the real-world provincial system to verify its effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pulsed Magnet Power Systems at NSLS-II

The National Synchrotron Light Source - II (NSLS-II) is a 3 GeV X-ray user facility with 29 beamlines. The NSLS-II pulsed power system consists of an event generator for timely injection and extraction of beam in the transport line from linac to booster at 170 MeV, and from booster to storage ring at 3 GeV. We will discuss current pulsed power systems and the future upgrades/improvements on those systems.

43 PARTICLE ACCELERATORS↗

Spatiotemporal Super-Resolution with Generative Machine Learning for Creating Renewable Energy Resource Data Under Climate Change Scenarios

As we plan for a future with higher penetrations of renewables and increasing electrification, it becomes more important to understand how the electricity grid will operate under a variety of weather events. We must also consider that the weather our future grid will experience will be different and possibly more extreme than the historical weather that we have extensive data for. We can use data from global climate models (GCMs) to help understand how our climate may change over the next several decades, but there is often a significant gap between the low-resolution GCM data and the high-resolution weather data required to study power systems under specific weather events. Therefore, our objective in this work is to develop tools that can bridge this gap by using low-resolution GCM data to create realistic high-resolution weather datasets that can be used to study renewable energy generation and electricity demand. To accomplish this objective, we have developed a set of generative machine learning models that can rapidly downscale GCM daily average output data at an approximate grid resolution of 100km to hourly data at an approximate 4 km grid resolution. The models can be used to create high resolution data from nearly any GCM included in the Coupled Model Intercomparison Project (CMIP) Phase 5 or 6. Our methods include all datasets regularly used to study the integration of wind and solar power plants as well as changes in electricity demand due to heating and cooling loads. These models and datasets enable power systems modelers to study climate change-influenced weather events and their impact on the grid. We have downscaled and validated wind, solar, temperature, and humidity data with very promising results. The generative machine learning methods are computationally efficient and produce data that has similar statistical characteristics to current state-of-the-art historical datasets. We have trained initial generative models and produced an initial dataset collectively referred to as Sup3rCC: Super-Resolved Renewable Energy Resource Data with Climate Change Impacts. The data covers a (mostly) historical period from 2015-2025 and a future period from 2050-2059. We have also taken hypothetical high-electrification load data and scaled the heating and cooling loads with respect to the 2050-2059 high-resolution Sup3rCC meteorology. The results show how future levels of renewable energy generation and electrified load may be impacted by climate change, setting the stage for capacity expansion models to consider a dynamic climate through model years.

climate change↗

Real-Time Detection and Localization of Line Trip Event Via Relative Phase Angles

Line trip events widely exist in power systems. They can result in power outages and a huge economic loss if not promptly detected and localized. To provide a fast and precise solution, this paper presents a Complete Coverage of Voltage Measurement (CCVM)-based line trip event detection algorithm and a Relative Phase Angle (RPA)-based line trip event localization algorithm. First, frequency and relative phase angle features during a line trip event are calculated. Then, the CCVM-based algorithm is proposed from both frequency and rate of change of frequency estimation algorithm aspects. Additionally, the RPA-based algorithm is presented, and two cases are studied to demonstrate the uniqueness of the proposed algorithm. Various experiments are conducted, where the simulation results demonstrate that the proposed CCVM-based algorithm can detect a line trip event as short as 2.07 ms. In addition, the RPA-based algorithm has 1.26 times higher localization accuracy compared with the frequency magnitude-based and phase angle-based algorithms. In conclusion, the experiment results on the examples from two interconnected power systems in the U.S. verified the performance of the proposed algorithms in wide-area power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Opportunities for wave energy in bulk power system operations

Wave energy resources have high, yet largely untapped potential as candidate generation technology. In this paper, we perform a data-driven analysis to characterize the impact of wave energy integration on bulk-scale power systems and market operations. Through data-driven sensitivity studies centered on an optimization-based production cost modeling formulation, our work characterizes the inflection point beyond which wave integration starts impacting power system operations, considering present day transmission infrastructure. Furthermore, our analysis also considers the joint effects of wave energy integration and system-wide transmission expansion. Finally, potential resilience scenarios such as wildfire-driven transmission contingencies and heat wave events are investigated, whereby the contributions of grid-integrated wave energy in alleviating the effects of the resilience events are analyzed. As our demonstration test bed, we consider a reduced-order network topology for the U.S. Western Interconnection with wave energy generation integrated at carefully selected sites across the coastal areas of Washington, Oregon, and northern California. Our results indicate that over a representative year of operations, wave energy integration systematically reduces locational marginal prices (LMPs) of energy and price volatility, especially during periods of high wave resource availability (winter months for the U.S. west coast). Average, maximum, and minimum of hourly LMPs over a typical year of operation was reduced by 2.95, 51.28, and 1.13 $\$$/MWh respectively (over a baseline scenario with no wave energy integration), when the selected network model had a total of 5000 MW wave power installed capacity during the representative year of study. The effects of wave energy integration can remain localized with existing transmission infrastructure (identified to be most pronounced in the Pacific Northwest region in the example we studied). However, with concurrent transmission expansion, the impacts of wave energy integration are likely to have a higher geographical spread. Our results also indicate that wave energy may be able to assist power system operations during resilience events such as major transmission contingencies and heat wave events, although such benefits might be dependent on factors such as proximity of affected area to wave resources, availability of adequate resource potential and adequate transmission capacity.

16 TIDAL AND WAVE POWER↗

Stochastic Continuous-time Flexibility Scheduling and Pricing in Wholesale Electricity Markets

Large-scale integration of intermittent renewable energy sources (RES) is calling for additional flexibility resources as well as more advanced modeling and optimization techniques to account for the increasing uncertainty and variability in power systems operation. As the RES integration gains momentum, the magnitude and frequency of their variations increase, which may trigger ramping scarcity events in real-time power systems operation. This necessitates revisiting the present definition of power systems flexibility and reserve services to reflect their robustness and adequacy towards sub-interval variations of the load and RES, as well as adjusting the operation models to accommodate the new reserve services. This project took a fundamental approach and aimed at developing continuous-time scheduling and pricing model that accurately models the continuous-time variations of load and RES and efficiently deploys the ramping capability of flexible resources to compensate the sources of variability and uncertainty in the market. In this regard, this project pursued the following goals: Developing stochastic multi-fidelity continuous-time optimization models for scheduling of energy storage (ES) systems and flexible loads in wholesale energy markets; Developing the theory and practices of continuous-time locational marginal pricing for valuating energy storage systems and flexible loads in wholesale energy markets; Developing function space solution approach to convert the proposed stochastic multi-fidelity continuous-time optimization models into tractable mixed-integer linear optimization models; and Defining flexibility reserve as a new type of reserve in markets that would enable ultimate participation of energy storage devices in provision of services to compensate the variability and uncertainty of RES in electricity markets. This project successfully completed all five major tasks defined in the SOPO, and produced 8 high-impact journal papers, 6 conference papers, 3 published U.S. patents, and one web-based software for continuous-time operation optimization of power systems. The application of the proposed flexibility reserve and the stochastic multi-fidelity continuous-time operation scheduling models would modify the forward commitment and schedule of generating units, ES devices and flexible loads, and would line up the resources in such a way that the composition of available resources is better prepared to respond to the sub-hourly variations of the load and renewable resources in real-time operation. Therefore, this project paves the way to sustainable, reliable, and economic integration of renewable energy resources in power system, supporting the progress towards reaching the national targets on energy independence. Even if the proposed models offers a radically different point of view as compared to existing models, it does not alter fundamentally the architecture of power systems operations, nor the complexity of the scheduling problem, so the integration of this project in power systems is extremely practical.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Quality and Stability in a Cluster of Microgrids with Coordinated Power and Energy Management

Distributed Energy Resources (DER) such as photovoltaic (PV) systems and battery energy storage systems (BESS) can be operated collectively as microgrids. Microgrids can be effective in meeting local load requirements as well as in improving the power quality and stability in a modern power distribution system. Multiple microgrids can also be operated in a coordinated manner as a cluster, to improve the resiliency of the power distribution system. In the event of an outage caused by a transmission system failure, the microgrids in a cluster can use their distributed generation capacity and energy storage resources to recover and extend power availability to the critical loads in the system. In this paper, an illustrative cluster of two microgrids based on the IEEE 13-bus model with DERs has been used, to demonstrate the operation of the concept using real-time simulations. Using real-time simulations, capabilities such as switching reconfiguration following faults, identification of optimal DER placement for effective power quality management, and power electronic controller validation have been demonstrated. For the two-microgrid cluster, this paper also presents improvements in load voltage quality and

Chowdhury, Prithwiraj Roy↗

Inferring adversarial behaviour in cyber‐physical power systems using a Bayesian attack graph approach

Abstract Highly connected smart power systems are subject to increasing vulnerabilities and adversarial threats. Defenders need to proactively identify and defend new high‐risk access paths of cyber intruders that target grid resilience. However, cyber‐physical risk analysis and defense in power systems often requires making assumptions on adversary behaviour, and these assumptions can be wrong. Thus, this work examines the problem of inferring adversary behaviour in power systems to improve risk‐based defense and detection. To achieve this, a Bayesian approach for inference of the Cyber‐Adversarial Power System (Bayes‐CAPS) is proposed that uses Bayesian networks (BNs) to define and solve the inference problem of adversarial movement in the grid infrastructure towards targets of physical impact. Specifically, BNs are used to compute conditional probabilities to queries, such as the probability of observing an event given a set of alerts. Bayes‐CAPS builds initial Bayesian attack graphs for realistic power system cyber‐physical models. These models are adaptable using collected data from the system under study. Then, Bayes‐CAPS computes the posterior probabilities of the occurrence of a security breach event in power systems. Experiments are conducted that evaluate algorithms based on time complexity, accuracy and impact of evidence for different scales and densities of network. The performance is evaluated and compared for five realistic cyber‐physical power system models of increasing size and complexities ranging from 8 to 300 substations based on computation and accuracy impacts.

Sahu, Abhijeet↗

PV Inverter Testing for Momentary Cessation and Rate-of-Change-of-Frequency Events: Preprint

To understand the power system stability and develop better electromagnetic transient (EMT) models of field deployed photovoltaic (PV) inverters, it is important to characterize inverters' response to abnormal voltage and frequency scenarios. Because EMT models are not typically available for small distribution-connected PV inverters, and because inerterconnection standards historically did not specify desired ride-through behaviors, we tested two such inverters in the lab to characterize their responses to severe undervoltage events and high rate-of-change-of-frequency (ROCOF) conditions. The inverters tested were pre-IEEE 1547-2018 residential PV inverters widely used in the Hawaiian Electric territory and many other areas. The testing results for undervoltage scenarios showed that the inverter from one vendor exhibited momentary cessation while the inverter from the other vendor did not exhibit momentary cessation behavior or tripping for most of the events below the 120 ms undervoltage trip threshold duration set by IEEE 1547-2003. The testing results for ROCOF scenarios showed that the inverter from one vendor temporarily lost synchronization during ROCOF conditions while the inverter from the other vendor did not lose synchronization or cease generation for any ROCOF conditions. Both the inverters were also tested for EMT-simulated grid events with severe changes in frequency and voltage. The observed responses of the inverters were different from the simulated response of PV inverters represented the best available assumptions from pre-existing information. The results from these experiments can be used to update the inverter models used in bulk power system studies.

IEEE 1547 2018↗

AI-Based Protective Relays for Electric Grid Resiliency

The protection systems (circuit breakers, relays, reclosers, and fuses) of the electric grid are the primary component responding to resilience events, ranging from common storms to extreme events. The protective equipment must detect and operate very quickly, generally <0.25 seconds, to remove faults in the system before the system goes unstable or additional equipment is damaged. The burden on protection systems is increasing as the complexity of the grid increases; renewable energy resources, particularly inverter-based resources (IBR) and increasing electrification all contribute to a more complex grid landscape for protection devices. In addition, there are increasing threats from natural disasters, aging infrastructure, and manmade attacks that can cause faults and disturbances in the electric grid. The challenge for the application of AI into power system protection is that events are rare and unpredictable. In order to improve the resiliency of the electric grid, AI has to be able to learn from very little data. During an extreme disaster, it may not be important that the perfect, most optimal action is taken, but AI must be guaranteed to always respond by moving the grid toward a more stable state during unseen events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ultra High-Temperature Magnetic Bearing System for s-CO 2 Turbines/Expanders. Phase II Final Report

The goal of this project is to design and construct of a prototype of ultra-high temperature permanent magnet (UHT–PM), which provides the force to pull the spinning shaft towards the target position in the magnetic bearing (MB) clearance circle. This project will develop a PM biased MB system, that is actively cooled to the 550°C maximum operating temperature limit of PMs. The MB test environment will include 700°C, 40krpm and 4,000 psi requirements to advance the supercritical carbon dioxide (sCO 2 ) and other types of Brayton power cycle systems. The proposed novel MBs combine PMs for supplying the bias field and electromagnets for supplying the control field, both in UHT conditions. The choice of material is the UHT Sm-Co PMs (US patent 6,451,132) due to their significantly better thermal stability. The 6-pole homopolar design permits uninterrupted force delivery via a redundant control capability (US patent 7,429,811) even if 3 poles were to fail. The Phase I efforts was to focus on development and demonstration of component technologies and detailed design of full scale components and a demonstrator test rig for use in Phase II. UHT–PMs were produced and used in the MB actuator. The operating environment of the EEC-T550 Sm-Co magnet material could be extended by implementing active cooling. Electromagnetic coils imbedded in the MB provide forces to stabilize the shaft position at the target via sensing and control stages. Shaft position sensors enable to identify the present position of the spinning shaft relative to its desired target position in the MB clearance circle (air gap). Auxiliary bearings will be installed to provide a backup support system in the event that power to the MB fails or there is a fault in a device providing current to the MB coils. For control, reliability and safety reasons the sensors and auxiliary bearings are typically located as close as possible to the MBs, which exposes them to the same environmental conditions. Development of only the actuator for the UHT environment is an inadequate approach to complete integration of the MB system in the turbine/expander. Therefore the UHT sensor and auxiliary bearing were designed and developed along with the actively cooled, UHT-PM actuator development. Although shaft position sensors are commercially available (Kaman) they may cost up to $10k per channel, and a full 5 axis magnetic suspension is best implemented with up to 20 sensors. Once successfully completed, this project will significantly extend the operating environment capability for turbomachinery applications such as nuclear power, concentrated solar thermal, fossil fuel, geothermal, and shipboard propulsion. The further advancement of UHT-PM-MB will also strengthen the US position in PM technology, which is presently heavily dominated by China. The UHT Sm-Co magnet material that will be utilized in the proposed work has been developed exclusively by the project proposer. Many actuators, motors, generators and other MB applications will greatly benefit from the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage

The energy system infrastructure that delivers power to a building's loads needs to be resilient to withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗