Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power plant model validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Assessment of Mechanical Draft Cooling Tower Thermal Emissions from Visual Images of Plumes

Using a one-dimensional code, we computed the power (enthalpy discharge rate) of a twelve-cell mechanical draft cooling tower (MDCT) using over two hundred visible condensed water vapor plume volume measurements derived from images, weather data, and tower operating conditions. The plume images were simultaneously captured by multiple stationary digital cameras surrounding the cooling tower. An analysis technique combining structure from motion (SfM), a neural-network-based image segmentation algorithm, and space carving was used to quantify the volumes. Afterwards, the power output was computed using novel techniques in the one-dimensional code that included cooling tower exhaust plume adjacency effects implemented with a modified version of the entrainment function, weather data averaged from eleven stations, and fan operations at the times when plume volumes were measured. The model was then compared with the averaged observed power output, and it validated well with an average error ranging from 6 to 12%, depending on the meteorological data used in the simulations. This methodology can possibly determine power plant fuel consumption rates by applying visible imagery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Zero power experiment for molten salt reactor - code verification and validation request

Molten Salt Reactors (MSRs) are one of the six perspective Generation IV nuclear technologies that should fulfil sustainability, economics, safety, and proliferation resistance goals. In recent years these concepts have attracted increased interest in research as well as in industry. In the context of developing new, innovative technology, a zero-power experiment would be an ideal option for improving the understanding of MSR systems under low-risk and low-cost conditions. The given research was focused on cross-verification of the nuclear codes for MSR modelling and simulations as required for the development of the first design of a potential facility and a draft of an experimental programme. The analysis included the evaluation of lattice and Monte Carlo codes. The study showed that all considered nuclear tools were in good agreement with each other. Although this does not mean the results will match the real experimental data, which is essential for the regulatory approval of a novel technology. Currently, experimental data is almost absent for MSR technology. Hence, a zero power experiment is needed to assure we can rely on modelling and simulation studies for further development of MSR technology and deliver real-world experiments to support the licensing of future MSRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Qualification and Commissioning of Helium Flow Loop Experiment for Blanket Design Measurements

Sufficient cooling of plasma-facing materials remains an outstanding challenge in the design of fusion reactor blankets in commercial power demonstration plants. Due to its chemical inertness and low neutron interaction cross section, pressurized helium is a candidate coolant fluid for such systems; however, helium has a small thermal mass compared to liquid coolants, potentially reducing heat removal performance. To address this need, a number of heat transfer enhancements have been proposed to improve the cooling efficiency of such components, thereby decreasing pumping power needs and improving overall plant efficiency. Toward this end, a helium flow loop experiment (HFLE) has been designed and commissioned to test advanced passive heat transfer enhancements in unit-cell test sections, providing necessary data for model validation and subsequent system design. The HFLE is designed to provide flow of pressurized (up to 4 MPa) helium at flow rates up to 80 g/s, enabling heat transfer and pressure drop measurements in test pieces at Reynolds numbers in excess of 180 000. To explore the effects of novel and complex heat transfer enhancements, test sections are produced via additive manufacturing, providing geometries not typically obtainable by conventional machining. Here in this work, we present results from HFLE commissioning and the initial thermal-hydraulic tests of an additively manufactured rifled-rib test section. Results are compared to smooth pipe correlations, and plans are described for future HFLE measurements. These preliminary experiments indicate the utility of the HFLE for heat transfer enhancement testing and simulation validation activities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatiotemporal Super-Resolution with Generative Machine Learning for Creating Renewable Energy Resource Data Under Climate Change Scenarios

As we plan for a future with higher penetrations of renewables and increasing electrification, it becomes more important to understand how the electricity grid will operate under a variety of weather events. We must also consider that the weather our future grid will experience will be different and possibly more extreme than the historical weather that we have extensive data for. We can use data from global climate models (GCMs) to help understand how our climate may change over the next several decades, but there is often a significant gap between the low-resolution GCM data and the high-resolution weather data required to study power systems under specific weather events. Therefore, our objective in this work is to develop tools that can bridge this gap by using low-resolution GCM data to create realistic high-resolution weather datasets that can be used to study renewable energy generation and electricity demand. To accomplish this objective, we have developed a set of generative machine learning models that can rapidly downscale GCM daily average output data at an approximate grid resolution of 100km to hourly data at an approximate 4 km grid resolution. The models can be used to create high resolution data from nearly any GCM included in the Coupled Model Intercomparison Project (CMIP) Phase 5 or 6. Our methods include all datasets regularly used to study the integration of wind and solar power plants as well as changes in electricity demand due to heating and cooling loads. These models and datasets enable power systems modelers to study climate change-influenced weather events and their impact on the grid. We have downscaled and validated wind, solar, temperature, and humidity data with very promising results. The generative machine learning methods are computationally efficient and produce data that has similar statistical characteristics to current state-of-the-art historical datasets. We have trained initial generative models and produced an initial dataset collectively referred to as Sup3rCC: Super-Resolved Renewable Energy Resource Data with Climate Change Impacts. The data covers a (mostly) historical period from 2015-2025 and a future period from 2050-2059. We have also taken hypothetical high-electrification load data and scaled the heating and cooling loads with respect to the 2050-2059 high-resolution Sup3rCC meteorology. The results show how future levels of renewable energy generation and electrified load may be impacted by climate change, setting the stage for capacity expansion models to consider a dynamic climate through model years.

climate change↗

Exploring the Feasibility of INCONEL® ALLOY 740H® for Power Plant Headers: Integrating Machine Learning with Computational Fluid Dynamics (CFD)

This keynote presentation explores the behavior of headers—essential components of pipeline systems—using ANSYS simulation software and machine learning techniques. The study aims to predict the thermal and mechanical performance of headers under diverse conditions through both steady-state and transient simulations. We investigate critical parameters such as heat transfer coefficient, fluid velocity, and temperature to optimize header design. Conducted as part of a DOE project led by NCAT in collaboration with UNC Charlotte, this research encompasses multiple key topics. The initial section focuses on the behavior of header systems under steady-state conditions using ANSYS simulation. It underscores the importance of headers in industrial infrastructure, especially in the energy sector, and examines the implications of material selection and flow direction on heat transfer dynamics. Methodologically, we employ Computational Fluid Dynamics (CFD) analysis through ANSYS, detailing the development of models, material properties, geometry specifications, boundary conditions, and meshing strategies. Our simulations explore various operational parameters, including temperature and mass flow rates, crucial for predicting heat transfer coefficients and enhancing header design. Results from the study include parametric investigations into mesh sensitivity, viscosity model evaluations, and the effects of heat transfer locations, all validated against theoretical calculations. We conclude with insights on mesh optimization, the suitability of viscosity models, and recommendations for future research aimed at improving header system efficiency and sustainability in industrial applications.

20 FOSSIL-FUELED POWER PLANTS↗

Technical Assessment of the Application of Digital Twin and Prognostic Tools for Condition Monitoring

This report was prepared for the U.S. Nuclear Regulatory Commission (NRC) to present use cases of the application of advanced technologies toward meeting the current and future regulatory requirements for maintenance and condition monitoring of structures, systems, and components (SSCs). The advanced technologies considered in this work, collectively referred to as digital twin (DT) technologies, are advanced sensors and instrumentation, data analytics, machine learning and artificial intelligence (ML/AI), and physics-based models. The report presents two use cases of reactor coolant pumps (RCPs) and heat pipes in nuclear power plants (NPPs) with technical and regulatory considerations and opportunities in using advanced technologies for conditional monitoring. Key findings from the exploration of these considerations are as follows: - Uncertainties in sensor data and model predictions must be rigorously addressed through validation and verification processes - Regulatory compliance is paramount, necessitating data driven models to be developed in line with existing codes and standards, as well as considering potential future guidelines for advanced reactors - Explainability and transparency in ML/AI models are essential for developing operator trust and regulatory review, including methods that enhance the interpretability of complex data-driven predictions - Condition monitoring programs must be evaluated for their effectiveness in reducing maintenance-preventable function failures (MPFF) and aligning with plant performance criteria - The deployment of advanced technologies for condition monitoring could lead to a transition from periodic to continuous monitoring, thereby optimizing maintenance schedules - Collaborative efforts between industry stakeholders, regulatory bodies, and technology developers are crucial for the successful adoption of advanced technologies for condition monitoring systems in nuclear facilities In summary, the introduction of advanced technologies into condition monitoring programs represents a significant leap forward in the domain of NPP maintenance. By harnessing the capabilities of advanced sensors, data analytics, and ML/AI, NPP operators can transition from a time-based to a condition-based maintenance approach. This shift can potentially enhance the reliability and safety of critical plant components while optimizing maintenance efforts and minimizing unnecessary outages. The NRC is continuing to explore the regulatory aspects of advanced technologies as part of inservice inspection and inservice testing (ISI and IST) programs by pursuing additional research in this technical area.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement of Wind Loading on Heliostats at the Crescent Dunes Power Plant: An Overview

The cost of solar collectors constitutes almost one third of the total cost of a CSP plant. One of the ongoing challenges in the design of these collectors is wind loading on mirrors, support structures, and drives. A particular challenge is dynamic wind loading, caused by the turbulent wind flow. To date, the design of solar collector structures has relied on wind tunnel experiments and numerical simulations that do not entirely capture the dynamic effects observed at scale. The CSP industry has shown increased interest in validating the idealized assumptions with measurements obtained in operational settings to improve wind load assumptions and increase reliability and cost-efficiency of the collector design. Further, performance models need realistic assumptions about wind loading and its impact on optical performance. In a parabolic trough field campaign, NREL successfully collected a wealth of long-term, high-resolution wind and loads data [2], that are publicly available and that can be used for the above-mentioned purposes. Heliostats are impacted differently by wind than parabolic troughs, due to their different shape, size, and field layout. To study the impact of wind and turbulence on heliostats, we initiated another field campaign in an operational power- tower plant, Crescent Dunes, in Nevada, USA. In this work, we present an overview of the measurements, first results, and potential implications of wind driven loads on Heliostats.

concentrated solar power↗

Virtual Power Plants: Pilots, Challenges, and Innovations Shaping Future Development

Virtual Power Plants (VPPs) aggregate distributed energy resources (DERs) to provide grid services traditionally delivered by centralized power plants. This article reviews the current state of VPP deployment, highlighting business models, compensation mechanisms, and global pilot projects. While VPPs offer benefits such as grid flexibility, resilience, and cost savings, challenges remain in communication infrastructure, regulatory frameworks, market access, and customer engagement. To address these, we propose a scalable, privacy-preserving hierarchical VPP architecture that coordinates with distribution utilities and preserves customer data. We also present the Integrated T&D Control Room of the Future as a key test bed for validating and accelerating VPP adoption. These innovations can help transition VPPs from pilot programs to integral components of a modern, reliable power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Quantitative resilience evaluation on recovery from emergency situations in nuclear power plants

Here, this paper mainly introduces how to develop a resilience evaluation model by quantifying the relationship between resilience and resilience components in regard to recovering from emergency situations in nuclear power plants (NPPs). It is an extension of the author’s previous researches. To develop the model, the first step was to analyze event reports published in Republic of Korea in terms of resilience factors from different safety perspectives. Second, statistical methods such as factor analysis, principal component analysis, and multivariate regression analysis were applied to the dataset to identify relations among resilience factors and develop a quantitative resilience evaluation model for recovery from emergency situations in NPPs. Third, the model was validated using the recent event report data released in Korea. Lastly, we present a discussion on how to apply the quantitative resilience evaluation model to results from stress tests performed in Korea.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Impact of Non-Steady State Operation on Cooling Water Consumption at Coal- and Natural Gas-Fired Power Plants

Increased renewable energy penetration in the electricity grid in coming decades will result in more frequent cycling at thermal power plants. Simultaneously, thermal power plants may face water scarcity with declining availability of cooling water. Therefore, to enhance thermal power plants’ resiliency to water shortages it is important to understand how non-steady conditions due to cycling will impact cooling water consumption and withdrawal intensity. Non-steady operation at power plants has been previously shown to decrease power plant thermal efficiency. Energy balance models have also demonstrated that a decrease in thermal efficiency is expected to increase cooling water consumption intensity. Furthermore, past work has used operating hours data to show idling and cycling gaps where cooling systems operate more than corresponding generators. As a result, an increase in cycling behavior may impact cooling water consumption and withdrawal intensity. This study uses data from the Energy Information Administration (EIA) and Environmental Protection Agency (EPA) to quantify the impact of cycling cooling water consumption intensity for recirculating cooling systems and withdrawal intensity for once-through cooling systems using energy balance and statistical approaches. In a novel application of a fixed effects model to study the effect of temperature on cooling water consumption and withdrawal intensity, this study finds temperature was consistently expected to increase consumption intensity and withdrawal intensity. Non-steady state conditions do not increase cooling water consumption intensity with statistical significance across unit types. However, additional validation of cooling water data is required to confirm these observed trends due to the sensitivity of these findings to model form and concerns with data quality of the dependent variables, cooling water consumption and withdrawal.

20 FOSSIL-FUELED POWER PLANTS↗

Direct comparison of gyrokinetic and fluid scrape-off layer simulations

Typically, fluid simulations are used for tokamak divertor design. However, fluid models are only valid if the scrape-off layer (SOL) is highly collisional. This assumption is valid in many present-day experiments but is questionable in the upstream SOL of some high-power scenarios envisioned for burning plasmas and fusion pilot plants. This paper reports on comparisons between fluid and kinetic simulations of the SOL for upstream parameters and geometry representative of the Spherical Tokamak for Energy Production fusion pilot plant. The SOLPS-ITER (fluid) and Gkeyll (gyrokinetic) codes are operated in a two-dimensional axisymmetric mode, which replaces turbulence with ad-hoc diffusivities. In kinetic simulations, we observe that the ions in the upstream SOL experience significant mirror trapping. This substantially increases the upstream temperature and has important implications for impurity dynamics. We show that the mirror force, which is excluded in SOLPS’s fluid equations, enhances the electrostatic potential drop along the field line in the SOL. We also show that the assumption of equal main ion and impurity temperatures, which is made in commonly used fluid codes, is invalid for the regimes explored here. The combination of these effects results in superior confinement of impurities to the divertor region in kinetic simulations, consistent with our earlier predictions [Kotschenreuther et al., in 29th IAEA 29 Fusion Energy Conference (IAEA, London, UK, 2023)]. This effect can be dramatic, reducing the midplane impurity density by orders of magnitude. These results indicate that in lower collisionality SOL’s the tolerable downstream impurity densities may be higher than would be predicted by fluid simulations, allowing for higher radiated power while avoiding unacceptable core contamination. Our results highlight the importance of kinetic simulations for divertor design and optimization for fusion pilot plants.

Computational fluid dynamics↗

Detection of the Metabolic Response to Drought Stress Using Hyperspectral Reflectance

Drought is the most important limitation on crop yield. Understanding and detecting drought stress in crops is vital for improving water use efficiency through effective breeding and management. Leaf reflectance spectroscopy offers a rapid, non-destructive alternative to traditional techniques for measuring plant traits involved in a drought response. We measured drought stress in six glasshouse-grown agronomic species using physiological, biochemical and spectral data. In contrast to physiological traits, leaf metabolite concentrations revealed drought stress before it was visible to the naked eye. We used full-spectrum leaf reflectance data to predict metabolite concentrations using partial least-squares regression, with validation R2 values of 0.49 to 0.87. We show for the first time that spectroscopy may be used for the quantitative estimation of proline and abscisic acid, demonstrating the first use of hyperspectral data to detect a phytohormone. We used linear discriminant analysis and partial least squares discriminant analysis to differentiate between droughted and watered plants based on measured traits (accuracy: 71%) and raw spectral data (66%). Finally, we validated our glasshouse-developed models in an independent field trial. We demonstrate that spectroscopy can detect drought stress via underlying biochemical changes, before visual differences occur, representing a powerful advance for measuring limitations on yield.

54 ENVIRONMENTAL SCIENCES↗

Non-linear MHD modelling of transients in tokamaks: a review of recent advances with the JOREK code

Transient magneto-hydrodynamic (MHD) events like edge localized modes (ELMs) or disruptions are a concern for magnetic confinement fusion power plants. Research with the MHD code JOREK towards understanding control of such instabilities is reviewed here in a concise way to provide a complete overview, while we refer to the original publications for details. Experimental validation for unmitigated vertical displacement events progressed. The mechanism of vertical force mitigation by impurity injection was identified. Two-way eddy current coupling to CARIDDI was completed. Shattered pellet injection was simulated in JET, KSTAR, ASDEX Upgrade (AUG) and ITER. Benign runaway electron beam termination in JET and ITER was studied. Coupling of kinetic REs to the MHD is ongoing and a virtual RE synchrotron radiation diagnostic was developed. Regarding pedestal physics, regimes devoid of large ELMs in AUG were simulated and predictive JT60-SA simulations are ongoing. For ELM suppression by resonant magnetic perturbations (RMPs), AUG, ITER and EAST simulations were performed. A free boundary RMP model was validated against experiments. Evidence for penetrated magnetic islands at the pedestal top based on AUG experiments and simulations was found. Simulations of the naturally ELM-free quiescent H-mode in AUG and HL-3 show external kink mode formation prevents pedestal build-up towards an ELM within windows of the edge safety factor. With kinetic neutral particles, high field side high density formation in ITER was simulated and with kinetic impurities, tungsten transport in AUG RMP plasmas was studied. To capture turbulent transport, electro-static full-f particle in cell models for ion temperature gradient and trapped electron modes were established and benchmarked. Application to RMP plasmas shows enhanced turbulence in comparison to unperturbed states. Energetic particle interactions with MHD were studied. Flux pumping that prevents the safety factor on axis from dropping below unity was simulated. First non-linear stellarator applications include current relaxation in $l$ = 2 stellarators, while verification for advanced stellarators progresses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Virtual Synchronous Generator Control of Multi-port Autonomous Reconfigurable Solar Plants (MARS)

Multi-port autonomous reconfigurable solar power plant (MARS) is an integrated concept for integration of solar photovoltaic (PV) and energy storage systems (ESS) to transmission alternating current (ac) grid and high-voltage direct current (HVdc) links. The integrated development incorporates advanced control methods to provide enhanced grid ancillary services such as fast frequency responses and dynamic voltage support. In this paper, the virtual synchronous generator (VSG) control algorithm of MARS is discussed. The proposed VSG-based control enables enhanced synthetic inertial response and flexible frequency response characteristics of hybrid PV and ESS power plants in accordance with grid ancillary service requirements. Multi-port power electronics interface allows controlled emergency power support from MARS to local transmission ac grid and remote grid through the HVdc link. The performance of VSG control is validated using a reduced-order model of MARS in Simulink. Methods for estimating grid ancillary service capabilities of MARS are also discussed.

Pan, Jiuping↗

Hyper-fidelity depletion coupled with discrete pebble motion in pebble bed reactors

Pebble bed reactors have raised new interest during the past decade due to their attractive characteristics. Therefore, accurate simulations must be performed to better understand these systems and ensure optimal and safe designs. Most current methods use lower fidelity approaches with representative unit-cells or macro-zones with uniform fluxes, which have accuracy and flexibility limitations. A novel hyper-fidelity method for pebble bed reactors depletion is presented and internally couples Serpent 2 and a pseudo-motion routine. Pseudo-motion is applied handling vertical shifts of compositions in a static pebble bed, random reinsertion of used pebbles, insertion of fresh pebbles and used pebbles discarding. Associated with individual depletion to correctly determine the flux spectrum and composition in each pebble, this hyper-fidelity approach paves the way towards more accurate depletion calculation in pebble bed reactors. Using this method, a demonstration is completed on a small-scale reactor. In this application, the core reaches equilibrium, and the following data is extracted: core-wise parameters evolution, pebble-wise spatial and statistical distribution. Discarded pebbles are analyzed, and relevant information is shown. This work proves the feasibility of hyper fidelity depletion with Serpent 2, and the range of use for this method: reactor design and analysis for equilibrium and slow transients, lower fidelity methods validation and feeding fuel performance, thermal-hydraulics, or waste management models. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Temperature Linear Receiver Enabled by Multicomponent Aerogels

Concentrating solar thermal (CST) technology has significant potential mainly due to its dispatchability and low cost of storage. However, to compete with other sources, including utility-scale solar PV, its final cost (cents/kWh) still needs to be lowered. Cost reduction can be achieved by improving the system level efficiency of the CST plants through the deployment of advanced power cycles, which operate at high temperatures of ~700°C. However, optical, and thermal losses pose a major challenge to the efficiency of such CST systems. The overall aim of this project is to investigate and de-risk a linear solar receiver concept called an Aerogel Insulated Receiver (AIR) that generates high temperatures (up to 700°C) at a low solar concentration ratio (<100) and with a high collection efficiency (optical × receiver). Our prior work has demonstrated the thermal stability1 and optical and heat-insulating properties2,3 of transparent aerogel insulation at a one-inch scale. The focus of this work is on (1) co-optimization of the geometry of the aerogel tile and receiver enclosure to fit a standard parabolic collector (PTC), (2) scale-up of aerogels into 4-inch tiles while preserving key properties, (3) experimental measurement of receiver heat loss (W/m) in a >70-cm test stand and validation of anticipated receiver performance at high temperatures. Regarding (1), appropriate optical and thermal models for a parabolic trough receiver (PTR) are developed and validated. The geometry of the aerogels and the receiver enclosure are co-optimized to maximize the collection efficiency. The model predicts a 54% collection efficiency at 700°C for an AIR design based on flat aerogels. By combining the collection efficiency with the power block efficiency of supercritical CO 2 cycles, we predict >10% improvements in peak plant efficiency relative to existing line-focusing CST systems. The application of curved plasmonic aerogels is predicted to further increase the collection efficiency to 64%. Regarding (2), we demonstrate the successful development of 6-inch-long refractory aerogel tiles with optical, thermal, and stability characteristics consistent with our prior work. This scale-up requires a transition to a larger ALD station and modifying the ALD process variables such as exposure time and the number of precursor doses. Regarding (3), we design and develop an AIR test stand measuring 3 feet in length. Heat loss performance analysis is carried out using the test stand. The results indicate that aerogel insulation can significantly reduce receiver thermal losses at the high operating temperatures required for next-generation PTRs. The experimental results agree with the heat loss performance predicted by our receiver model. Lastly, we conducted preliminary failure mode and effects (FMEA) and techno-economic (TEA) analyses to identify failure mitigation strategies and commercial opportunities, respectively. Overall, this project identifies key opportunities and challenges in deploying aerogel insulating receivers in next-generation line-focusing CST technologies.

14 SOLAR ENERGY↗

Enhancing Solar Power Forecasting with Regularized Constrained Quantile Regression Averaging and Bootstrapping Techniques

Probabilistic solar power forecasting (SPF) plays an essential role in optimizing power-grid operations by quantifying the forecast uncertainty. To improve the accuracy and robustness of probabilistic SPF, this paper introduces the regularized constrained quantile regression averaging (rCQRA) method to combine outputs from multiple PSPF models. In addition, a bootstrapping method was used to quantify model uncertainty, providing insights into the reliability and significance of each ensemble component. To evaluate its efficacy, the proposed rCQRA method is used to integrate four PSPF methods. The resulting SPF models are trained and validated using a real-world six-year dataset from a rooftop solar plant in the USA. The performance of the proposed rCQRA method is evaluated and compared with two benchmark methods under three categories of weather conditions. It is shown that the rCQRA method has superior performance in its forecast reliability, sharpness, and accuracy.

Ensemble learning, probabilistic solar power forec↗