Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power flow control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

Modeling active control of resistive wall mode with power saturation and sensor noise on HL-2M

The resistive wall mode (RWM) control on the HL-2M tokamak is simulated with the MARS-F code (Liu et al 2000 Phys. Plasmas 7 3681), aiming at quantifying control current and voltage requirements when more realistic issues are taken into account, i.e. the control power saturation and the sensor signal noise. The fluid model predicts a narrow stability region for the n = 1 RWM without magnetic feedback, in the 2D parameter space of the plasma pressure versus the toroidal flow speed. Magnetic feedback can fully stabilize the RWM on HL-2M. Without considering the voltage limitation and the sensor signal noise, it is found that plasma flow helps active control of the mode, by reducing the required critical feedback gain for both flux-to-current and flux-to-voltage control schemes. In the absence of the sensor signal noise, the lowest control voltage saturation level, below which the RWM control is lost, is found to roughly satisfy a linear relation to the plasma flow frequency, indicating that subsonic plasma flow is effective in relaxing the control power requirement for the RWM feedback stabilization. The presence of the sensor signal noise substantially modifies the feedback results. A statistical study finds that the sensor signal noise, with the standard deviation of 0.1 G on HL-2M, roughly doubles the required control voltage for successful mode control. The synergistic stabilization effect due to plasma flow is somewhat weakened by the presence of the sensor signal noise. At a given rotation, the tolerable voltage limit generally increases with increasing feedback gain due to the sensor signal noise.

Physics↗

Application of Site Controllers for Electrification of Commercial Fleet Vehicles

Electrification of transportation fleets presents a significant challenge for commercial customers. These challenges can be specific to region, weather, operating schedule, charging infrastructure, and other factors. This paper presents the value of integrating a site controller to monitor the health of assets and co-optimize the operation of commercial sites with multiple distributed energy resource technologies and electric vehicle fleets. The tests demonstrate smart-charging and vehicle-to-building uses compared to business-as-usual cases. The secondary objectives of power management for the customer vehicle are optimized by a planning tool (REopt) and integrated using the site controller. Any deviations from the planned dispatch are addressed by the real-time controllers offering tertiary controls, such as energy management, and limiting the reverse power flow (back into the grid). The results indicate that site controllers offer an efficient solution to manage the health of the connected assets and a scalable means to optimize the operations of a commercial customer with electrified transportation fleets.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Constraints on OPF Surrogates for Learning Stable Local Volt/Var Controllers

We consider the problem of learning local Volt/Var controllers in distribution grids (DGs). Our approach starts from learning separable surrogates that take both local voltages and reactive powers as arguments and predict the reactive power setpoints that approximate optimal power flow (OPF) solutions. We propose an incremental control algorithm and identify two different sets of slope conditions on the local surrogates such that the network is collectively steered toward desired configurations asymptotically. Our results reveal the trade-offs between each set of conditions, with coupled voltage-power slope constraints allowing an arbitrary shape of surrogate functions but risking limitations on exploiting generation capabilities, and reactive power slope constraints taking full advantage of generation capabilities but constraining the shape of surrogate functions. AC power flow simulations on the IEEE 37-bus feeder illustrate their guaranteed stability properties and respective advantages in two DG scenarios.

asymptotic stability↗

Control of Vibration Systems with Mechanical Motion Rectifier and their Applications to Vehicle Suspension and Ocean Energy Harvester

Vibration control is a large branch in control research, because all moving systems may induce desired or undesired vibration. Due to the limitation of passive system’s adaptability and changing excitation input, vibration control brings the solution to change system dynamic with desired behavior to fulfill control targets. According to preference, vibration control can be separated into two categories: vibration reduction and vibration amplification. Lots of research papers only examine one aspect in vibration control. The thesis investigates the control development for both control targets with two different control applications: vehicle suspension and ocean wave energy converter. It develops control methods for both systems with simplified modeling setup, then followed by the application of a novel mechanical motion rectifier (MMR) gearbox that uses mechanical one-way clutches in both systems. The flow is from the control for common system to the control design for a specifically designed system. In the thesis, active (model predictive control: MPC), semi-active (Skyhook, skyhook-power driven damper: SHPDD, hybrid model predictive control: HMPC), and passive control (Latching Control) methods are developed for different applications or control performance comparison on single system. The thesis also studies about new type of system with switching mechanism, in which other papers do not talk too much and possible control research direction to deal with such complicated system in vibration control. The state-space modeling for both systems are provided in the thesis with detailed model of the MMR gearbox. From the simulation, it can be shown that in the vehicle suspension application, the controlled MMR gearbox can be effective in improving vehicle ride comfort by 29.2% compared to that of the traditional hydraulic suspension. In the ocean wave energy converter, the controlled MMR WEC with simple latching control can improve the power generation by 57% compared to the passive MMR WEC. Besides, the passive MMR WEC also shows its advantage on the passive direct drive WEC in power generation improvement. From the control development flow for the MMR system, the limitation of the MMR gearbox is also identified, which introduces the future work in developing active-MMR gearbox by using an electromagnetic clutch. Some possible control development directions on the active-MMR is also mentioned at the end of the thesis to provide reference for future works.

16 TIDAL AND WAVE POWER↗

MIDAS-DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution (MIDAS-DC2AC)

MIDAS DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

Tan, Jin↗

DC-AC Tool: Fully Automating the Acquisition of AC Power Flow Solution

DC2AC is an automated tool for achieving a converged AC power flow solution from any dispatch, e.g., determined using DC power flow model based optimal power flow. The entire process is free of human interference. It is usually encountered in practice that, even with a DC power flow solution, acquiring the solved AC power flow solution, if exists, sometimes could be a challenging task, especially during the planning stage. It is also difficult to distinguish the unsolvable cases from diverging iterations. Manual adjustments to approach the desired power flow condition has been largely relied on in the past using lots of engineering heuristics. This tool provides a systematic way to first achieve a solvable AC power flow case by modifying the power flow condition, and then try to track the AC power flow solution while gradually removing the adopted changes. If all adopted changes can be completely removed, then the original AC power flow solution is obtained. Otherwise, insights for actionable controls are derived to help operation and planning. Currently, this tool has been implemented in Python using SIEMENS PTI PSS/E as power flow solver, where only adjusting generator terminal voltage set point is considered as an available means to try to turn an unsolved power flow to a solved one. In future, more means should be considered, including the operation of tap-changing transformers, switched shunts and redispatch of active power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a Time-to-Digital Converter ASIC and a mini-DAQ system for the Phase-2 upgrade of the ATLAS Monitored Drift Tube detector

We present the second prototype of a time-to-digital (TDC) ASIC for the upgrade of the ATLAS Monitored Drift Tube (MDT) detector for High-Luminosity LHC operations. Compared to the first prototype, triple modular redundancy has been implemented for the configuration and flow control logic. Here, the total power consumption is increased by less than 10 mW while achieving the same time resolution and channel uniformity. A mini-DAQ system has been built to verify the front-end electronics chain with the new prototype together with other ASICs and boards in triggered mode. Cosmic ray tests with a small-diameter MDT chamber indicate that the configuration and data transmission of the readout electronics perform well. It is expected that this prototype design will be used in the final production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal Power Flow With State Estimation in the Loop for Distribution Networks

Here in this article, we propose a framework for running optimal control-estimation synthesis in distribution networks. Our approach combines a primal-dual gradient-based optimal power flow solver with a state estimation feedback loop based on a limited set of sensors for system monitoring, instead of assuming exact knowledge of all states. The estimation algorithm reduces uncertainty on unmeasured grid states based on certain online state measurements and noisy "pseudomeasurements." We analyze the convergence of the proposed algorithm and quantify the statistical estimation errors based on a weighted least-squares estimator. The numerical results on a 4521-node network demonstrate that this approach can scale to extremely large networks and provide robustness to both large pseudomeasurement variability and inherent sensor measurement noise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Recovery in Power Grids Using High-Performance Computing

Maintaining electric power system stability is paramount, especially in extreme contingencies involving unexpected outages of multiple generators or transmission lines that are typical during severe weather events. Such outages often lead to large supply-demand mismatches followed by subsequent system frequency deviations from their nominal value. The extent of frequency deviations is an important metric of system resilience, and its timely mitigation is a central goal of power system operation and control. This paper develops a novel nonlinear model predictive control (NMPC) method to minimize frequency deviations when the grid is affected by an unforeseen loss of multiple components. Our method is based on a novel multi-period alternating current optimal power flow (ACOPF) formulation that accurately models both nonlinear electric power flow physics and the primary and secondary frequency response of generator control mechanisms. We develop a distributed parallel Julia package for solving the large-scale nonlinear optimization problems that result from our NMPC method and thereby address realistic test instances on existing high-performance computing architectures. Our method demonstrates superior performance in terms of frequency recovery over existing industry practices, where generator levels are set based on the solution of single-period classical ACOPF models.

nonlinear model predictive control↗

Anomaly Detection and Mitigation for Wide-Area Damping Control using Machine Learning

In an interconnected multi-area power system, wide-area measurement based damping controllers are used to damp out inter-area oscillations, which jeopardize grid stability and constrain the power flows below to their transmission capacity. The effect of wide-area damping control (WADC) significantly depends on both power and cyber systems. At the cyber system layer, an adversary can inflict the WADC process by compromising either measurement signals, control signals or both. Stealthy and coordinated cyber-attacks may bypass the conventional cybersecurity measures to disrupt the seamless operation of WADC. This paper proposes an anomaly detection (AD) algorithm using supervised Machine Learning and a model-based logic for mitigation. The proposed AD algorithm considers measurement signals (input of WADC) and control signals (output of WADC) as input to evaluate the type of activity such as normal, perturbation (small or large signal faults), attack and perturbation-and-attack. Upon anomaly detection, the mitigation module tunes the WADC signal and sets the control status mode as either wide-area mode or local mode. The proposed anomaly detection and mitigation (ADM) module works inline with the WADC at the control center for attack detection on both measurement and control signals and eliminates the need for ADMs at the geographically distributed actuators. Here, we consider coordinated and primitive data-integrity attack vectors such as pulse, ramp, relay-trip and replay attacks. The performance of the proposed ADM algorithms was evaluated under these attack vector scenarios on a testbed environment for 2-area 4-machine power system. The ADM module shows effective performance with 96:5% accuracy to detect anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Chapter 7: Learning Stable Local Volt/Var Controllers in Distribution Grids

This chapter describes a framework to synthesize provably stable local Volt/Var controllers for distributed energy resources (DERs) in power distribution grids (DGs). The goal is to control the reactive power injections of DERs to improve the system performance as quantified by a generic optimal reactive power flow (ORPF) problem. To achieve this, we jointly design for each DER the control function, which prescribes the reactive power update rule, and the equilibrium function, which approximates the ORPF solutions from local measurements of voltages and powers. We provide conditions on the equilibrium functions and the control parameters ensuring the stability of the closed-loop system. In particular, we discuss the trade-offs between each set of conditions accounting for practical considerations, like fully exploiting the DERs' generation capabilities and reducing the optimality gap. These conditions are then translated into learning constraints on the neural networks' parameters that are enforced in the training phase. We validate our framework with numerical simulations on the IEEE 37-bus network and through a comparison with an optimized version of standard piece wise linear control rules.

closed-loop asymptotic stability↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Segmented Energy Routing for a Modular AC/DC Hybrid System

This article presents a modular ac/dc system with both distributed and centralized power ports for energy router (ER) applications. In each module of the described system, photovoltaic (PV) power generation units, battery-type energy storage (ES) units, and critical loads are connected to the cascaded H-bridge (CHB)-organized medium-voltage (MV) dc links, with fully distributed low-voltage (LV) dc power ports. Copies of modules share the centralized load bus and interact with an MV ac grid in parallel. Hybrid power port (HPO) assigns flexibility to the system but makes energy routings a necessity for stable operation. In this article, a segmented energy management strategy for the HPO-ER is proposed. In terms of the grid-side power transferring, the system ratings are intentionally designed to match significant power imbalance. Focally, a segmented energy management strategy is proposed to realize fully autonomous energy routing involving MV ac grid, distributed PV generations, distributed battery storages, and LV load. The system is proven to be stable using the derived impedance-based model considering the interaction between power blocks. The feasibility of the topology and control strategy is also verified through software simulation, laboratorial hardware prototype experiment, and hardware-in-the-loop (HIL) emulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Scalable, Distribution Network-Aware, Customer Privacy-Preserving Framework for Operation of Virtual Power Plants

This poster presents a hierarchical control framework for a virtual power plant that leverages behind-the-meter resources for grid services while maintaining customer privacy during setpoint disaggregation. Unlike many existing approaches, the virtual power plant model uses a hierarchical control strategy and an iterative approach to determine the optimal set point dis-aggregation without direct load control while maintaining system-level power flow and voltage constraints. The proposed approach is numerically validated on a synthetic distribution feeder in San Francisco, demonstrating the ability of the framework to provide privacy-preserving virtual power plant services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Learning Local Volt/VAR Controllers Toward Efficient Network Operation with Stability Guarantees: Preprint

This paper considers the problem of voltage regulation in distribution network. The primary motivation is to keep voltages within pre-assigned operating limits by commanding the reactive power output of distributed energy resources (DERs) deployed in the grid. We develop a framework for developing local Volt/Var control that comprises of two main steps. In the first, exploiting historical data and for each DER, we learn a function representing desirable equilibrium points for the power network. These points approximate solutions of an Optimal Power Flow problem. In the second, we propose a control scheme for steering the network towards these favorable configurations. Theoretical conditions are derived to formally guarantee the stability of the developed control scheme and numerical simulations illustrate the effectiveness of the proposed approach.

data-driven control↗

Decentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration: Preprint

This paper introduces a fully decentralized control strategy that allows for individualized active and reactive power control of H-bridge inverters connected in series. After formulating a model of the system power flows, we outline a communications-free approach where each inverter can act on independent commands. Inverter-level feedback is accomplished locally via a measurement of current flowing through the stack. A key feature is the lack of any centralized control routines or phase-locked loop. In this framework, the reactive power control loops achieve voltage synchronization among the converters and the grid, and the active power control loops modulate the terminal voltage amplitudes that influence power delivery. Furthermore, pole placement via state feedback is used to ensure stability of voltage synchronization while also enabling tracking of bidirectional power commands. Simulations are presented to validate the proposed approach.

communication-free modular converter control↗