Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Exploration Portable Life Support System Hatch Component Design

The design for the Exploration Extravehicular Mobility Unit (xEMU) is continuously being developed and many previous gaps in technologies have begun initial development. Various Exploration Portable Life Support System (xPLSS) Hatch components had been at a stall in technology development for many years including the Feedwater Supply Assembly, Trace Contaminant Control System, and the thermal loop filters. The challenging requirements and initial design of these components were previously discussed in “Exploration Portable Life Support System Hatch Component Design Challenges and Progress”. NASA has plans to go back to the Moon. The development of each of these components is relevant not only to the xEMU, but also to the International Space Station, Gateway, and commercial space businesses. As the xPLSS is being designed, built, integrated, and tested at the NASA Johnson Space Center, technology solutions will have a direct incorporation path as the xPLSS is matured to meet design and performance goals. This is a follow on paper to discuss the initial implementation of the hatch component designs, changes due to existing challenges, and performance results of these components as the xEMU project completes the first phase of towards flight, known as Design Verification Test (DVT).

Kristina Todd↗

Portable Long-Wavelength Infrared Camera for Civilian Application

In this paper, we discuss the performance of this portable long-wavelength infrared camera in quantum efficiency, NEAT, minimum resolvable temperature differnce (MRTD), uniformity, etc. and its application in science, medicine and defense.

infrared wavelength portable↗

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

Evaluation of the Danish Aerospace Corporation Portable Pulmonary Function System

A research project designed to investigate changes in maximal oxygen consumption (VO2max) during and following long duration flight on the International Space Station (ISS) has recently been completed. The device used to measure VO2 on board ISS, the Portable Pulmonary Function System (PPFS) manufactured by the Danish Aerospace Corporation (DAC), is based on previous-generation devices manufactured by DAC, but the PPFS has not been validated for analyzing metabolic gases or measuring cardiac output (Qc). The purpose of the present evaluation is to compare PPFS metabolic gas analysis measurements to measurements obtained using a clinically-validated system (ParvoMedics TrueOne(c) 2400 system; Parvo). In addition, Qc data collected with the PPFS were compared to Qc measurements from echocardiography. METHODS: Ten subjects completed three cycle exercise tests to maximal exertion. The first test was conducted to determine each subject's VO2max and set the work rates for the second and third (comparison) tests. The protocol for the two comparison tests consisted of three 5-minute stages designed to elicit 25%, 50%, and 75% VO2max (based upon results from the initial test), followed by 1-minute stages of increasing work rate (25 watt/minute) until the subject reached maximal effort. During one of the two comparison tests, metabolic gases and Qc were assessed with the PPFS; metabolic gases and Qc were assessed with the Parvo and by echocardiography, respectively, during the other test. The order of the comparison tests was counterbalanced. VO2max and maximal work rate during the comparison tests were compared using t tests. Mixed-effects regression modeling was used to analyze submaximal data. RESULTS: All of the data were within normal physiological ranges. The PPFS-measured values for VO2max were 6% lower than values obtained with the Parvo (PPFS: 3.11 +/- 0.75 L/min; Parvo: 3.32 +/- 0.87 L/min; mean +/- standard deviation; P = 0.02); this difference is probably due to flow restriction imposed by the PPFS Qc accessories. Submaximal VO2 values were slightly lower when measured with the PPFS, although differences were not physiologically relevant. The PPFS-measured values of submaximal carbon dioxide production (VCO2) were lower than the data obtained from Parvo, which could be attributed to lower fractions of expired carbon dioxide measured by the PPFS. The PPFS Qc values tended to be lower than echocardiography-derived values. CONCLUSIONS: The results of the present study indicate a need to further examine the PPFS and to better quantify its reproducibility; however, none of the findings of the current evaluation indicate that the PPFS needs to be replaced or modified.

Portable Pulmonary Function System (PPFS)↗

A Portable High-Density Power Technology for Space, Lunar, and Planetary Applications

A new direct energy conversion concept called Nuclear Thermionic Avalanche Cell (NTAC) combined with a Metallic Junction Thermoelectric (MJ-TE) generator, both invented and patented by NASA, offers high specific power for portable applications. Estimates based on experimental results suggest superior performance compared to radioisotope thermoelectric generators (RTG) by up to two orders of magnitude for the NTAC and three to four times better for the MJ-TE generator for the same mass. The NTAC technology can use a variety of radioisotopes including nuclear waste to liberate a large number of intra-band(IB), inner shell electrons of atoms (105 C/cm3) by gamma-ray photons (100 keV to MeV). In contrast, conventional power generation has poor specific power because they only utilize the valence band electrons (3C/cm3) of the semiconductor or free electrons (8×103 C/cm3) of the conductor.

NTAC↗

Exploration Extravehicular Mobility Unit (xEMU): Electron Beam Welding of the Portable Life Support System (PLSS) Ti-6Al-4V Backplate with Integrated Cooling Channels

The Exploration Extravehicular Mobility Unit (xEMU) is the first clean sheet redesign of the astronaut spacesuit in approximately 40 years. NASA Langley Research Center’s electron beam welding team, of which the author is a member, is leading the development of the weld technology required to manufacture the backplate component of the Portable Life Support System (PLSS). This backplate will provide both structural support and integral cooling for the life support systems, communications, and other electronics inside the spacesuit.

electron beam welding↗

Portable flooring protects finished surfaces, is easily moved

To protect curved, finished surface and provide support for workmen, portable flooring has been made from rigid plastic foam blocks, faced with aluminum strips. Held together by nylon webbing, the flooring can be rolled up for easy carrying.

Carmody, R. J.↗

Portable tool removes burrs from pipe and tubing

Portable tool cleanly removes burrs that remain on tubing when it is cut. It restores the cut end to its original configuration, and carries away all chips and pieces. This tool is used in places of limited access where a larger tool could not be used.

Headley, C. A.↗

Portable tool cleans pipes and tubing

Portable tool cleans and polishes the external surfaces of tubes and pipes without contaminating the interior areas with loose particles. The tool is driven by an electric drill and is connected to a vacuum source that removes debris resulting from the cleaning and polishing action.

Headley, C. A.↗

Portable PFM Simulator

Portable transistorized circuit pulse frequency modulation /PFM/ simulator with power supply regulator

TRANSISTOR CIRCUIT↗

Mount makes liquid nitrogen-cooled gamma ray detector portable

Liquid nitrogen-cooled gamma ray detector system is made portable by attaching the detector to a fixture which provides a good thermal conductive path between the detector and the liquid nitrogen in a dewar flask and a low heat leak path between the detector and the external environment.

Fessler, T. E.↗

Portable power tool machines weld joints in field

Portable routing machine for cutting precise weld joints required by nonstandard pipe sections used in the field for transfer of cryogenic fluids. This tool is adaptable for various sizes of pipes and has a selection of router bits for different joint configurations.

Spier, R. A.↗

Portable sandblaster cleans small areas

Portable sandblasting unit rapidly and effectively cleans localized areas on a metal surface. The unit incorporates a bellows enclosure, masking plate, sand container, and used sand accummulator connected to a vacuum system. The bellows is equipped with an inspection window and light for observation of the sanding operation.

Severin, H. J.↗