Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Portable Electron-Beam Free-Form Fabrication System

A portable electron-beam free-form fabrication (EB F3) system, now undergoing development, is intended to afford a capability for manufacturing metal parts in nearly net sizes and shapes. Although the development effort is oriented toward the eventual use of systems like this one to supply spare metal parts aboard spacecraft in flight, the basic system design could also be adapted to terrestrial applications in which there are requirements to supply spare parts on demand at locations remote from warehouses and conventional manufacturing facilities. Prior systems that have been considered for satisfying the same requirements (including prior free-form fabrication systems) are not easily portable because of their bulk and massive size. The mechanical properties of the components that such systems produce are often inferior to the mechanical properties of the corresponding original, conventionally fabricated components. In addition, the prior systems are not efficient in the utilization of energy and of feedstock. In contrast, the present developmental system is designed to be sufficiently compact and lightweight to be easily portable, to utilize both energy and material more efficiently, and to produce components that have mechanical properties approximating those of the corresponding original components. The developmental EB F3 system will include a vacuum chamber and associated vacuum pumps, an electron-beam gun and an associated power supply, a multiaxis positioning subsystem, a precise wire feeder, and an instrumentation system for monitoring and control. The electron-beam gun, positioning subsystem, and wire feeder will be located inside the vacuum chamber (see figure). The electron beam gun and the wire feeder will be mounted in fixed positions inside the domed upper portion of the vacuum chamber. The positioning subsystem and ports for the vacuum pumps will be located on a base that could be dropped down to provide full access to the interior of the chamber when not under vacuum. During operation, wire will be fed to a fixed location, entering the melted pool created by the electron beam. Heated by the electron beam, the wire will melt and fuse to either the substrate or with the previously deposited metal wire fused on top of the positioning table. Based on a computer aided design (CAD) model and controlled by a computer, the positioning subsystem

Watson, J. Kevin↗

Portable Multigas Monitors for International Space Station

The Environmental Health System (EHS) on International Space Station (ISS) includes portable instruments to measure various cabin gases that acutely impact crew health. These hand-held devices measure oxygen, carbon dioxide, carbon monoxide, hydrogen chloride and hydrogen cyanide. The oxygen and carbon dioxide units also serve to back up key functions of the Major Constituent Analyzers. Wherever possible, commercial off-the-shelf (COTS) devices are employed by EHS to save development and sustaining costs. COTS hardware designed for general terrestrial applications however has limitations such as no pressure compensation, limited life of the active sensor, calibration drift, battery issues, unpredictable vendor support and obsolescence. The EHS fleet (inflight and ground inventory) of instruments is both aging and dwindling in number. With the retirement of the US Space Shuttle, maintenance of on-orbit equipment becomes all the more difficult. A project is underway to search for gas monitoring technology that is highly reliable and stable for years. Tunable Diode Laser Spectroscopy (TDLS) seems to be the front-runner technology, but generally is not yet commercially available in portable form. NASA has fostered the development of TDLS through the Small Business Innovative Research (SBIR) program. A number of gases of interest to the aerospace and submarine communities can be addressed by TDLS including the list mentioned above plus hydrogen fluoride, ammonia and water (humidity). There are several different forms of TDLS including photoacoustic and direct absorption spectroscopy using various multipass cell geometries. This paper describes the history of portable gas monitoring on NASA spacecraft and provides a status of the development of TDLS based instruments. Planned TDLS flight experiments on ISS could lead both to operational use on ISS and important roles in future Exploration spacecraft and habitats.

Mudgett, Paul D.↗

Development of the International Space Station (ISS) Fine Water Mist (FWM) Portable Fire Extinguisher ICES Abstract

NASA is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. FWM extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. The following paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE. In addition, the NASA ISS specific fire standards will be described which were developed to establish acceptable extinguisher performance. The paper will also discuss the flight hardware design. The fin e water mist fire extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface have been under development for several years. They have gone through several design iterations, and have been part of more than 400 fire challenge and spray characterizations. The crew and vehicle interface aspects of the design will use the heritage of the CO2 based Portable Fire Extinguisher, to minimize the disruption to the crew and integration impacts to the ISS. The microgravity use environment of the system poses a set of unique design requirements specifically for the tank. The nozzle requirements drive a tank pressure that is 2-5 times higher than any commercially available water mist systems. Microgravity requires deliberate separation of gas and water, facilitated by a bladder, a diaphragm, a piston, or separate tanks. This paper will describe status of the project to date, the design details of the tank and the nozzle, and discuss the trade studies that informed the decisions to select the tank and nozzle configuration.

Clements, Anna L.↗

A Portable, High Resolution, Surface Measurement Device

A high resolution, portable, surface measurement device has been demonstrated to provide micron-resolution topographical plots. This device was specifically developed to allow in-situ measurements of defects on the Space Shuttle Orbiter windows, but is versatile enough to be used on a wide variety of surfaces. This paper discusses the choice of an optical sensor and then the decisions required to convert a lab bench optical measurement device into an ergonomic portable system. The necessary trade-offs between performance and portability are presented along with a description of the device developed to measure Orbiter window defects.

Ihlefeld, Curtis M.↗

Laser Spiderweb Sensor Used with Portable Handheld Devices

A portable spectrometer, including a smart phone case storing a portable spectrometer, wherein the portable spectrometer includes a cavity; a source for emitting electromagnetic radiation that is directed on a sample in the cavity, wherein the electromagnetic radiation is reflected within the cavity to form multiple passes of the electromagnetic radiation through the sample; a detector for detecting the electromagnetic radiation after the electromagnetic radiation has made the multiple passes through the sample in the cavity, the detector outputting a signal in response to the detecting; and a device for communicating the signal to a smart phone, wherein the smart phone executes an application that performs a spectral analysis of the signal.

Scott, David C.↗

Portable, Low-Cost, Column Carbon Dioxide and Methane Measurements for Validating Satellite Observations in Remote Locations

We present a low-cost (~$10K per instrument), portable solution to ground-based validation of satellite observations for difficult to reach locations with precisions of 1 ppm XCO2 and 10 ppb XCH4 for hourly data products. While Total Carbon Column Observing Network (TCCON) is the gold-standard for ground validation, there are locations where a ground column validation data point would be useful but conditions are not conducive to a permanent station. Examples include wetlands, thawing permafrost, the tropics, the Amazon, sub-Saharan Africa, as well as locations without a power grid or with geopolitical conflict. In addition, the low-cost and portability mean a geographical region can be studied in depth with multiple instruments. This passive, sun-pointing instrument is a miniaturized, laser heterodyne radiometer (mini-LHR) that has been under development by our team since 2009. It can be operated either in tandem with AERONET (a global network of 500 instruments that measure aerosol optical depth), or as a stand-alone instrument with a low-cost (~$3K), light-weight sun tracker. One of the main benefits of the mini-LHR is that it can quickly reach remote locations and provide a validation measurement even if there is limited or no infrastructure at the site. The instrument weighs ~10 lbs, fits into a backpack, and is powered by two folding solar panels and a battery pack. In clear conditions, the instrument can be set-up in under an hour. Portability means that mini-LHRs can be easily moved for side-by-side comparisons with other mini-LHRs and with TCCON which simplifies assessing instrument bias as well as accuracy. Like TCCON, the mini-LHR points directly at the sun with a narrow field-of-view and is its insensitivity to cloud and aerosol scattering that is common to nadir-pointing passive satellite approaches. Here we present a collection of sample data sets to demonstrate performance from locations that vary in climate, altitude, solar zenith angle, hours of sun per day, etc., as well as data from side-by-side TCCON comparisons. Retrievals of CO2 and CH4 were completed using the NASA/Goddard's Planetary Spectrum Generator (PSG) that incorporates meteorological inputs from Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) data set.

Wilson, Emily W.↗

Portable Laser Guided Robotic Metrology System

This paper introduces the new Portable Laser Guided Robotic antenna range (PLGR) at the National Aeronautics and Space Administration's (NASA) Glenn Research Center. Previous work used industrial robots in fixed facilities to characterize antennas and required fixtures that do not lend themselves to portable applications.NASA's PLGR system is designed for in-situ antenna measurements at a remote site. The system consists of a robot arm mounted on a vertical lift and a laser tracker, each on a portable base. The lift and laser tracker enable scanning a surface larger than the robot's reach. To accomplish this the robot first collects all points within its reach, then the system is moved and the laser tracker is used to relocate the robot before additional points are captured.The PLGR architecture will be discussed including how safety systems and path planning are combined to effectively characterize antennas. Software was written in high level languages for flexible integration of vector network analyzers and antenna controllers. Lastly, data will be shown to demonstrate the system functionality and accuracy.

Slater, Peter A.↗

Portability: A Necessary Approach for Future Scientific Software

Today's world of scientific software for High Energy Physics (HEP) is powered by x86 code, while the future will be much more reliant on accelerators like GPUs and FPGAs. The portable parallelization strategies (PPS) project of the High Energy Physics Center for Computational Excellence (HEP/CCE) is investigating solutions for portability techniques that will allow the coding of an algorithm once, and the ability to execute it on a variety of hardware products from many vendors, especially including accelerators. We think without these solutions, the scientific success of our experiments and endeavors is in danger, as software development could be expert driven and costly to be able to run on available hardware infrastructure. We think the best solution for the community would be an extension to the C++ standard with a very low entry bar for users, supporting all hardware forms and vendors. We are very far from that ideal though. We argue that in the future, as a community, we need to request and work on portability solutions and strive to reach this ideal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating Portable Parallelization Strategies for Heterogeneous Architectures in High Energy Physics

High-energy physics (HEP) experiments have developed millions of lines of code over decades that are optimized to run on traditional x86 CPU systems. However, we are seeing a rapidly increasing fraction of floating point computing power in leadership-class computing facilities and traditional data centers coming from new accelerator architectures, such as GPUs. HEP experiments are now faced with the untenable prospect of rewriting millions of lines of x86 CPU code, for the increasingly dominant architectures found in these computational accelerators. This task is made more challenging by the architecture-specific languages and APIs promoted by manufacturers such as NVIDIA, Intel and AMD. Producing multiple, architecture-specific implementations is not a viable scenario, given the available person power and code maintenance issues. The Portable Parallelization Strategies team of the HEP Center for Computational Excellence is investigating the use of Kokkos, SYCL, OpenMP, std::execution::parallel and alpaka as potential portability solutions that promise to execute on multiple architectures from the same source code, using representative use cases from major HEP experiments, including the DUNE experiment of the Long Baseline Neutrino Facility, and the ATLAS and CMS experiments of the Large Hadron Collider. This cross-cutting evaluation of portability solutions using real applications will help inform and guide the HEP community when choosing their software and hardware suites for the next generation of experimental frameworks. We present the outcomes of our studies, including performance metrics, porting challenges, API evaluations, and build system integration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of performance portability solutions for GPUs and many-core CPUs to track reconstruction kernels

Next generation High-Energy Physics (HEP) experiments are presented with significant computational challenges, both in terms of data volume and processing power. Using compute accelerators, such as GPUs, is one of the promising ways to provide the necessary computational power to meet the challenge. The current programming models for compute accelerators often involve using architecture-specific programming languages promoted by the hardware vendors and hence limit the set of platforms that the code can run on. Developing software with platform restrictions is especially unfeasible for HEP communities as it takes significant effort to convert typical HEP algorithms into ones that are efficient for compute accelerators. Multiple performance portability solutions have recently emerged and provide an alternative path for using compute accelerators, which allow the code to be executed on hardware from different vendors. We apply several portability solutions, such as Kokkos, SYCL, C++17 std::execution::par and Alpaka, on two mini-apps extracted from the mkFit project: p2z and p2r. These apps include basic kernels for a Kalman filter track fit, such as propagation and update of track parameters, for detectors at a fixed z or fixed r position, respectively. The two mini-apps explore different memory layout formats. We report on the development experience with different portability solutions, as well as their performance on GPUs and many-core CPUs, measured as the throughput of the kernels from different GPU and CPU vendors such as NVIDIA, AMD and Intel.

Kwok, Ka Martin↗

Scaling and performance portability of the particle-in-cell scheme for plasma physics applications through mini-apps targeting exascale architectures

We perform a scaling and performance portability study of the particle-in-cell scheme for plasma physics applications through a set of mini-apps we name "Alpine", which can make use of exascale computing capabilities. The mini-apps are based on Independent Parallel Particle Layer, a framework that is designed around performance portable and dimension independent particles and fields. We benchmark the simulations with varying parameters such as grid resolutions (5123 to 20483) and number of simulation particles (109 to 1011) with the following mini-apps: weak and strong Landau damping, bump-on-tail and two-stream instabilities, and the dynamics of an electron bunch in a charge-neutral Penning trap. We show strong and weak scaling and analyze the performance of different components on several pre-exascale architectures such as Piz-Daint, Cori, Summit and Perlmutter. While the scaling and portability study helps identify the performance critical components of the particle-in-cell scheme in the current state-of-the-art computing architectures, the mini-apps by themselves can be used to develop new algorithms and optimize their high performance implementations targeting exascale architectures.

Muralikrishnan, Sriramkrishnan↗

Ir-192 radioisotope replacement with a hand-portable 1 MeV Ku-band electron linear accelerator

Although linear accelerators are used in many security, industrial and medical applications, the existing technologies are too large and expensive for several critical applications such as radioactive source replacement, field radiography and mobile cargo scanners. Here, one of the main requirements for these sources is to be highly portable to allow field operation. In response to this problem, RadiaBeam has designed a hand-portable 1 MeV X-ray source, scalable to higher energies, based on Ku-band split electron linac, that can be used for Ir-192 radioisotope replacement. In this paper, we present its multiphysics and engineering design studies, as well as an accelerating structure prototype along with RF measurements.

43 PARTICLE ACCELERATORS↗

Implementing a neural network interatomic model with performance portability for emerging exascale architectures

The two main thrusts of computational science are increasingly accurate predictions and faster calculations; to this end, the zeitgeist in molecular dynamics (MD) simulations is pursuing machine learned and data driven interatomic models, e.g. neural network potentials, and novel hardware architectures, e.g. GPUs. Current implementations of neural network potentials are orders of magnitude slower than traditional interatomic models and while looming exascale computing offers the ability to run large, accurate simulations with these models, achieving portable performance for MD with new and varied exascale hardware requires rethinking traditional algorithms, using novel data structures, and library solutions. We re-implement a neural network interatomic model in CabanaMD, an MD proxy application, built on libraries developed for performance portability. Our implementation shows significantly improved thread scaling in this complex kernel as compared to a current LAMMPS implementation, across both strong and weak scaling. Our single-source solution enables simulations up to 20 million atoms on a single CPU node and 4 million atoms with improved performance on a single GPU. Furthermore, we also explore parallelism and data layout choices (using flexible data structures called AoSoAs) and their effect on performance, seeing up to ~50% and ~5% improvements in performance on a GPU by choosing the right level of parallelism and data layout respectively.

97 MATHEMATICS AND COMPUTING↗

Achieving performance portability in Gaussian basis set density functional theory on accelerator based architectures in NWChemEx

The numerical integration of the exchange–correlation (XC) potential is one of the primary computational bottlenecks in Gaussian basis set Kohn–Sham density functional theory (KS-DFT). To achieve optimal performance and accuracy, care must be taken in this numerical integration to preserve local sparsity as to allow for near linear weak scaling with system size. This leads to an integration scheme with several performance critical kernels which must be hand optimized for each architecture of interest. As the set of available accelerator hardware goes more diverse, a key challenge for developers of KS-DFT software is to maintain performance portability across a wide range of computational architectures. In this article, we examine a modular software design pattern which decouples the implementation details of performance critical kernels from the expression of high-level algorithmic workflows in a device-agnostic language such as C++; thus allowing for developers to target existing and emerging accelerator hardware within a single code base. We consider the efficacy of such a design pattern in the numerical integration of the XC potential by demonstrating its ability to achieve performance portability across a set of accelerator architectures which are representative of those on current and future U.S. Department of Energy Leadership Computing Facilities.

97 MATHEMATICS AND COMPUTING↗

Toward performance-portable PETSc for GPU-based exascale systems

The Portable Extensible Toolkit for Scientific computation (PETSc) library delivers scalable solvers for nonlinear time-dependent differential and algebraic equations and for numerical optimization. The PETSc design for performance portability addresses fundamental GPU accelerator challenges and stresses flexibility and extensibility by separating the programming model used by the application from that used by the library, and it enables application developers to use their preferred programming model, such as Kokkos, RAJA, SYCL, HIP, CUDA, or OpenCL, on upcoming exascale systems. Furthermore, a blueprint for using GPUs from PETSc-based codes is provided, and case studies emphasize the flexibility and high performance achieved on current GPU-based systems.

97 MATHEMATICS AND COMPUTING↗

Ku-band electron linac for battery-powered hand-portable 2-MeV X-ray generator

X-ray generators, producing radiation in MeV range, are a critical tool for radiography, non-destructive testing and security applications. Field operation of such source requires them to be hand-portable, autonomous and allow parameter adjustability. RF linear accelerators can serve as a flexible, reliable, and robust radiation generator alternative to dangerous radioisotopes and bulky betatrons that are currently used for field radiography if their size, weight, cost, and imaging performance are matched to these sources. Here, in this paper, we present the design and test results of a 2 MeV Ku-band electron linac for a hand-portable X-ray generator system for field radiography being developed by RadiaBeam. The dramatic scale of miniaturization and cost-reduction is achieved thanks to the implementation of innovative technologies such as air-cooled Ku-band air-traffic control magnetrons, a split accelerating structure fabrication technique, and solid-state Marx modulators. This paper presents the design of the first prototype of the accelerator, its operation from Li-Ion batteries, as well as high-power and beam measurements.

43 PARTICLE ACCELERATORS↗

A portable and reusable sensor system based on graphene for real-time and sensitive detection of lead ions in water

Long-term exposure to Pb 2+ can cause irreversible damage to the nervous, cardiovascular, and reproductive systems. Therefore, developing a fast and sensitive detection system capable of monitoring minuscule concentrations of Pb 2+ is essential. In this study, we demonstrated a fully portable sensor system enabling rapid, sensitive, and real-time monitoring of Pb 2+ . The sensor system adopted the remote-gate field-effect transistor (RGFET) detection scheme and was easy to operate, even for non-experts. The sensor system comprised two printed circuit boards (PCBs): a sensor PCB with a remote-gate electrode and an analyzer PCB with a metal-oxide-semiconductor field-effect transistor (MOSFET) transducer and peripheral electronics to manage sensor signals. To achieve a high sensitivity for Pb 2+ , we utilized graphene ink drop-casted on the sensor PCB as a sensing membrane. The graphene film was easy to deposit and remove, enabling the sensor PCB to be reused multiple times. The sensor system was further linked to a smartphone application that instantly monitors the sensor response, allowing for rapid point-of-use detection. The sensor exhibited a high sensitivity of 21.7% when the limit of detection (LOD) value of 1 nM (∼0.2 ppb) was detected, and the typical detection time for each sample was approximately 60 seconds. This portable sensor system advances sensing technologies and could potentially supplement expensive, laborious conventional sensing equipment.

54 ENVIRONMENTAL SCIENCES↗

Ultralightweight Power System for Human-Portable Linac-Based X-Ray Sources

Industrial human-portable X-ray sources are widely used by security, nuclear safeguard, and defense agencies. However, the employed sources have significant energy, dose, size, weight, and power (SWaP) limitations, greatly affecting their practical application. RF linear accelerators (linacs) can serve as a flexible, reliable, and robust type of X-ray source if they can match the size, weight, cost, and imaging performance requirements of conventional ones. One of the most critical elements affecting these parameters is the high-voltage pulsed power supply system or modulator, which can make the largest contribution to the total weight and dimensions of the accelerator. Here, in this article, we present the design and demonstration results of a novel ultra lightweight power system based on a 24-kV solid-state Marx modulator for a hand-portable 0.15–2.0-MeV Ku -band linac-based X-ray source.

47 OTHER INSTRUMENTATION↗