Environmental parameters of the Tennessee River in Alabama. 1: Thermal stratification

Thermal stratification data of a transect across Wheeler Reservoir are correlated with the climatological data at the time of sampling. This portion of the Tennessee River is used as a heat sink for the effluent from the three reactor Browns Ferry Nuclear Power Plant. The transect sampling line is 1.3 miles below this point of effluence. Data are presented by weekly samplings for one year prior to plant operations. Post-operational data are presented with one reactor in operation and with two reactors in partial operation. Data gathering was terminated when the plant ceased operations. The results indicate that the effluent for partial plant operation were inconclusive. As a result, recommendations include continuing the sampling when the plant resumes operation at full capacity. Recommendations also include developing math models with the presented thermal and climatological data to be used for predicting the effluent impact in the river with varying climatological conditions and also to predict the effectiveness of the cooling towers.

Rosing, L. M.↗

Pump and Treat Impacts on Aquifer Conditions and the Development of System-wide Performance Strategies - 19077

The 200 West pump-and-treat (P and T) system on the Hanford Site's Central Plateau currently treats multiple contaminants within the 200-ZP-1 Operable Unit (OU). Initially designed to support the 200-ZP1 Remedial Action Objectives, the use of the P and T system has evolved over time to address contaminants from other regions of the aquifer as well. The P and T system currently receives water from other regions within the Central Plateau that are biogeochemically distinct, treating groundwater with elevated concentrations of carbon tetrachloride, cyanide, uranium, technetium-99, and nitrate. Given the varying geochemical signatures from current and potential future sources, combined with the operational conditions and amendments used for treatment processes, there is a need to identify the impacts of the P and T system on the aquifer and aquifer impacts on P and T performance. To this end, initial laboratory analyses and geochemical modeling efforts focused on characterizing the baseline geochemical environment for the aquifer in the 200-ZP-1 OU. Several sediment characterization techniques, including geologic descriptions, water and acid extractions, and microbiological measurements were selected to determine key geochemical and microbiological constituents for the baseline, prior to injection of the effluent from the treatment plant. Different geochemical components within sediment samples from the aquifer were identified that may significantly affect how the sediments react to P and T injection water. Batch experiments were also used to identify aquifer impacts on operational performance and support development of some column studies. These experiments were designed to test and evaluate variable P and T effluents using actual effluent solutions from the treatment plant as well as simulated Hanford groundwater at different temperatures to identify the important geochemical and biological reactions that might occur within the aquifer. Initial results were used for geochemical modeling of the effluents and batch experiments. These results, along with the baseline data obtained from the initial sediment characterization, are intended to feed into the design of the column studies and inform conceptual models and modeling efforts for evaluating the fate and transport of introduced contaminants and co-injectates, and their short- and long-term impact on the aquifer-system injection capacity. This evaluation is designed to provide additional information on the major geochemical and microbiological reactions that are driven by the injection of the P and T effluent into the aquifer. Reactive transport modeling of the laboratory experiments and extrapolation to a larger-scale modeling domain provide information that can be used for predictive evaluations of system performance based on P and T operational changes and aquifer mass loading and capacity estimates. This information can be used to address combined subsurface and operational challenges, such as the need for frequent well redevelopment to maintain injection capacity. This information also provides the technical basis for decisions related to the P and T system operations that support remedy optimization efforts and short- and long-term remedy decisions related to multiple OUs on the Hanford Site Central Plateau. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Water-Related Technology Performance Development

This U.S. Department of Energy/National Energy Technology Laboratory techno-economic analysis evaluates those parameters having the greatest performance and cost impact on wet flue gas desulfurization (FGD) effluent wastewater treatment systems, and air cooled condensers for dry cooling systems. Two supercritical pulverized coal power plants are considered: 1) an existing plant (modified for surface water discharge and air emissions consistent with limits for existing plants) retrofitted with wet FGD effluent wastewater treatment and 2) a greenfield plant constructed with an air-cooled condenser (ACC). Sensitivity analyses are completed on various process parameters associated with the wet FGD effluent wastewater treatment system and ACC to determine the impact on the net plant efficiency and levelized cost of electricity (LCOE). Research and development targets are recommended for the parameters shown to have the greatest potential impact on cost or performance.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis of Microbial Communities Associated with Bioremediation Systems for Thiocyanate-Laden Mine Water Effluents

During the processing of refractory gold ores, cyanide (CN - ) and residual sulphur species react to form an effluent stream containing thiocyanate (SCN - ) and residual CN - . The release of SCN - and CN - containing effluent water to the environment is prohibited, necessitating effective treatment prior to discharge and/or reuse of contaminated plant water. Biologically mediated effluent remediation processes have been developed for commercial use, to remediate SCN - containing effluents, with the aim of enabling recycling of process water and improving the quality of effluent water prior to disposal. Bioremediation processes to treat these effluents rely on a complex consortium of microorganisms to metabolise the SCN - resulting in the production of ammonium that is in turn removed by conversion to nitrite and subsequent denitrification. Increasingly, genomic methods are being used to investigate processes in wastewater treatment to identify key microbial species and, thereby, inform the rationale design and operation of these bioremediation systems. The microbial ecology of laboratory-based SCN - degrading bioprocesses have been investigated, using genome resolved metagenomics, to provide detailed information on the community composition and metabolic profile of abundant microbial community members. Our on-going research is focused on developing a greater understanding of the heterotrophic and autotrophic populations of microorganisms within the SCN - degrading community as well as the role of the component members in SCN - destruction. We are interested in the formation of microbial biofilm and the spatial distribution of key microorganisms within the resulting biofilm communities. This information is being used to inform further rational development of SCN - degradation processes for treatment of contaminated wastewater effluents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Case Study: Integrate Nuclear Water Desalination - Regional Potable Water in Arizona

The present study analyzes the economic viability of an Integrated Energy System (IES) that couples a Reverse Osmosis (RO) water desalination facility with a Nuclear Power Plant (NPP). The case study is conducted in collaboration with Arizona Public Service (APS), the operating owner of the Palo Verde Generating Station (PVGS) NPP. Cooling water for the reactor steam cycle is derived from treated effluent from municipal wastewater treatment plants. APS has established a long-term water resources program to effect a substantial reduction in plant cooling costs through advanced treatment and cooling technologies, and through the use of alternative water sources to replace the increasingly expensive effluent. One possible option is to replace some amount of the annual volume of effluent with brackish groundwater from a local regional aquifer. Although much less expensive than the municipal effluent, the quantity of brackish groundwater that could be used for plant cooling is limited as a result of the salinity and its impact on plant operation. Consequently, supplemental treatment could be required such that a greater amount of brackish groundwater could be used to reduce the demand on effluent. A study was conducted in 2018 by Idaho National Laboratory (INL) to investigate the economics of a PVGS onsite RO desalination plant that would reduce the salinity of a municipal effluent and brackish water blend to an acceptable level. One of the main findings of that study was that the overall economics of water desalination can be greatly improved if, in addition to cooling water for PVGS, potable water could also be produced and sold for profit. In fact, the study concluded that only producing cooling water for PVGS via RO desalination is not economically viable. The present report investigates the economic impact of a large, regional RO desalination plant that could provide potable water for the region, considering the conclusions from the 2018 scoping study. The study looks in particular at the water-market situation for the developing municipalities in the west valley of Phoenix. In addition to providing potable water for the municipalities, the existing infrastructure that conveys effluent to the Palo Verde plant and onsite water treatment facilities could be used to manage the RO concentrate. The processed concentrate could lead to a cost reduction in plant cooling by replacing some amount of effluent. The analysis reported here considers two cases (for various scenarios). First, the Base Case considers that neither the regional nor the onsite RO is built. The 2018 INL study showed that some brackish water can be blended with the municipal effluent water without having to build the onsite RO. That correspond to the maximum economically profitable option. The Base Case is where APS pumps the maximum volume of less-expensive brackish water (limited by water chemistry in the circulating water system), i.e. the case for which cooling water acquisition and treatment cost are lowest (without RO). Second, the proposed RO Case includes two RO plants, one onsite at PVGS and another larger, regional RO plant close to the brackish water wells. The regional RO produces potable water that is sold to the regional municipalities, while the PVGS onsite RO treats (part of) the regional ROs' concentrate and brackish water blend. The desalinated water from the PVGS RO is used in the circulating water system at PVGS. The analysis evaluates the difference in economics, using the Net Present Value (NPV) and Internal Rate of Return (IRR), between the cases. By comparing the two cases, in addition to evaluating the economics of the regional RO, we can also assess the impact of the regional RO on PVGS operational costs and, consequently, APS economics. The study shows that there exist combinations of regional RO and PVGS RO sizes for which the total blowdown and water chemistry limits at PVGS (including regional RO concentrate treatment at PVGS) are satisfied. However, such combinations only exist if no additional brackish water is directly mixed in the tertiary water system at PVGS. This leads to higher Levelized Costs of Potable Water (LCOPW) compared to cases where additional brackish water is injected (but violate the physical constraints). Additional studies are suggested to investigate the benefit of additional brackish water injection (lowers cooling water cost) versus the cost of lifting the physical constraints, e.g. building additional evaporation ponds. Staying in the case of no additional brackish water and satisfying the existing PVGS constraints, the lowest LCOPW (~0.5 $/m 3 ) can be achieved with a size of the regional RO of ~1.4e7 m 3 /yr (11000 AF/yr) capacity, which leads to ~8.63e6 m 3 /yr (7000 AF/yr) of potable water while no onsite RO at PVGS is built. Considering the vii residential water demand model developed for the Phoenix west valley, the NPV for this regional RO would be ~$100 million if all municipalities in the vicinity participate from the beginning of the project.

97 MATHEMATICS AND COMPUTING↗

Demonstrations of Holistic, Lower Cost/Energy Effluent Water Management Approaches for Coal-Fired Energy Plants

The project work conducted under DOE award DE-FE0031678 was comprised of three overarching project goals: (1) evaluate the performance of Saltworks’ Flex EDR Selective process for treating wet flue gas desulfurization (FGD) wastewater, (2) conduct bench-scale testing of wastewater encapsulation as a byproduct management technology for the EDR generated brine, and (3) develop a dynamic water balance model encompassing the results of the aforementioned testing.

01 COAL, LIGNITE, AND PEAT↗

Fully automated measuring equipment for aqueous boron and its application to online monitoring of industrial process effluents

Fully automated measuring equipment for aqueous boron (referred to as the online boron monitor) was developed on the basis of a rapid potentiometric determination method using a commercial BF{sub 4}{sup -} ion-selective electrode (ISE). The equipment can measure boron compounds with concentration ranging from a few to several hundred mg/L, and the measurement is completed in less than 20 min without any pretreatment of the sample. In the monitor, a series of operations for the measurement, i.e., sampling and dispensing of the sample, addition of the chemicals, acquisition and processing of potentiometric data, rinsing of the measurement cell, and calibration of the BF{sub 4}{sup -} ISE, is automated. To demonstrate the performance, we installed the monitor in full-scale coal-fired power plants and measured the effluent from a flue gas desulfurization unit. The boron concentration in the wastewater varied significantly depending on the type of coal and the load of power generation. An excellent correlation (R{sup 2} = 0.987) was obtained in the measurements between the online boron monitor and inductively coupled plasma atomic emission spectrometry, which proved that the developed monitor can serve as a useful tool for managing boron emission in industrial process effluent. 22 refs., 6 figs.

01 COAL, LIGNITE, AND PEAT↗

2013 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2012, through October 31, 2013. The report contains, as applicable, the following information: • Site description • Facility and system description • Permit required monitoring data and loading rates • Status of compliance conditions and activities • Discussion of the facility’s environmental impacts. During the 2013 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant and therefore, no effluent flow volumes or samples were collected from wastewater sampling point WW-014102. However, soil samples were collected in October from soil monitoring unit SU-014101.

2013 annual wastewater reuse report↗

Air pollutant production by algal cell cultures

The production of phytotoxic air pollutants by cultures of Chlorella vulgaris and Euglena gracilis is considered. Algal and plant culture systems, a fumigation system, and ethylene, ethane, cyanide, and nitrogen oxides assays are discussed. Bean, tobacco, mustard green, cantaloupe and wheat plants all showed injury when fumigated with algal gases for 4 hours. Only coleus plants showed any resistance to the gases. It is found that a closed or recycled air effluent system does not produce plant injury from algal air pollutants.

Fong, F.↗

Cleanup Verification Package for the 126-F-1, 184-F Powerhouse Ash Pit

This cleanup verification package documents completion of remedial action for the 126-F-1, 184-F Powerhouse Ash Pit. This waste site received coal ash from the 100-F Area coal-fired steam plant. Leakage of process effluent from the 116-F-14 , 107-F Retention Basins flowed south into the ash pit, contaminating the northern portion.

100F Area↗

Cleanup Verification Package for the 126-F-1, 184-F Powerhouse Ash Pit

This cleanup verification package documents completion of remedial action for the 126-F-1, 184-F Powerhouse Ash Pit. This waste site received coal ash from the 100-F Area coal-fired steam plant. Leakage of process effluent from the 116-F-14 , 107-F Retention Basins flowed south into the ash pit, contaminating the northern portion.

100F Area↗

Co-Generation Wastewater Treatment at Coal-Fired Energy Plants (Final Report)

Steam electric energy generation typically results in the discharge of one or more effluent streams. Coal-fired energy plant air quality regulations have had the effect of transferring pollutants previously in the flue gas to water by means of the flue gas desulfurization (FGD) system. Combined physical-chemical and biological treatment solutions are currently the most economical approach for treating FGD wastewater. Multi-effect evaporators are significantly higher cost but can meet potential upcoming regulations that are more stringent.

01 COAL, LIGNITE, AND PEAT↗

The fibrate drug gemfibrozil disrupts lipoprotein metabolism in rainbow trout

Gemfibrozil (GEM) is a fibrate drug consistently found in effluents from sewage treatment plants. This study characterizes the pharmacological effects of GEM on the plasma lipoproteins of rainbow trout (Oncorhynchus mykiss). Our goals were to quantify the impact of the drug on: 1) lipid constituents of lipoproteins (phospholipids (PL), triacylglycerol (TAG), and cholesterol), 2) lipoprotein classes (high, low and very low density lipoproteins), and 3) fatty acid composition of lipoproteins. Potential mechanisms of GEM action were investigated by measuring lipoprotein lipase activity (LPL) and the hepatic gene expression of LPL and of the peroxisome proliferator-activated receptor (PPAR) {alpha}, {beta}, and {gamma} isoforms. GEM treatment resulted in decreased plasma lipoprotein levels (- 29%) and a reduced size of all lipoprotein classes (lower PL:TAG ratios). However, the increase in HDL-cholesterol elicited by GEM in humans failed to be observed in trout. Therefore, HDL-cholesterol cannot be used to assess the impact of the drug on fish. GEM also modified lipoprotein composition by reducing the abundance of long-chain n-3 fatty acids, thereby potentially reducing the nutritional quality of exposed fish. The relative gene expression of LPL was increased, but the activity of the enzyme was not, and we found no evidence for the activation of PPAR pathways. The depressing effects of GEM on fish lipoproteins demonstrated here may be a concern in view of the widespread presence of fibrates in aquatic environments. Work is needed to test whether exposure to environmental concentrations of these drugs jeopardizes the capacity of fish for reproduction, temperature acclimation or migratory behaviors.

60 APPLIED LIFE SCIENCES↗

2014 Annual Wastewater Reuse Report for the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant

This report describes conditions, as required by the state of Idaho Wastewater Reuse Permit (#LA-000141-03), for the wastewater land application site at the Idaho National Laboratory Site’s Central Facilities Area Sewage Treatment Plant from November 1, 2013, through October 31, 2014. The report contains, as applicable, the following information; Site description; Facility and system description; Permit required monitoring data and loading rates; Status of compliance conditions and activities; and Discussion of the facility’s environmental impacts. The current permit expires on March 16, 2015. A permit renewal application was submitted to Idaho Department of Environmental Quality on September 15, 2014. During the 2014 permit year, no wastewater was land-applied to the irrigation area of the Central Facilities Area Sewage Treatment Plant and therefore, no effluent flow volumes or samples were collected from wastewater sampling point WW-014102. Seepage testing of the three lagoons was performed between August 26, 2014 and September 22, 2014. Seepage rates from Lagoons 1 and 2 were below the 0.25 inches/day requirement; however, Lagoon 3 was above the 0.25 inches/day. Lagoon 3 has been isolated and is being evaluated for future use or permanent removal from service.

2014 Annual Wastewater Reuse Report Central Facili↗

Application of Landsat Thematic Mapper data for coastal thermal plume analysis at Diablo Canyon

The possibility of using Landsat Thematic Mapper (TM) thermal data to derive absolute temperature distributions in coastal waters that receive cooling effluent from a power plant is demonstrated. Landsat TM band 6 (thermal) data acquired on June 18, 1986, for the Diablo Canyon power plant in California were compared to ground truth temperatures measured at the same time. Higher-resolution band 5 (reflectance) data were used to locate power plant discharge and intake positions and identify locations of thermal pixels containing only water, no land. Local radiosonde measurements, used in LOWTRAN 6 adjustments for atmospheric effects, produced corrected ocean surface radiances that, when converted to temperatures, gave values within approximately 0.6 C of ground truth. A contour plot was produced that compared power plant plume temperatures with those of the ocean and coastal environment. It is concluded that Landsat can provide good estimates of absolute temperatures of the coastal power plant thermal plume. Moreover, quantitative information on ambient ocean surface temperature conditions (e.g., upwelling) may enhance interpretation of numerical model prediction.

Gibbons, D. E.↗