Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “phosphorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

SITCOMTN-148: LSST Camera Electro-Optical Test (Run 7) Results

This note collects results from the LSST Camera electro-optical testing prior to installation on the TMA. We describe the focal plane characterization, optimization, and the resulting default settings. Results from eo-pipe are shown for standard runs such as B-protocols, Dense and SuperDense PTCs, gain stability, OpSim runs of Darks, and Darks with variable delays. We also describe features such as e2v Persistence, ITL phosphorescence in coffee stains, remnant charge near Serial register following saturated images, vampire pixels, ITL dips, and other sensor features.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical design of the SBUV/TOMS experiment on Nimbus G

The paper examines the tradeoffs performed in optimizing the optical design of the solar backscatter ultraviolet/total ozone mapping spectrometer (SBUV/TOMS) experiment on Nimbus G to stringent performance requirements within the limitations of the spacecraft interface. The SBUV portion of the experiment incorporates a double monochromator optimized for better than 1.0 A spectral resolution over the wavelength range 1600-4000 A. The TOMS portion of the experiment is a stepped line scanning system with a 105-deg total field of view. Special techniques are used to reduce the polarization sensitivity of the instrument to less than 5% for 100% linearly polarized incident radiation and to keep the spectral stray light to less than 0.000001 of the incident solar spectrum. Optical material selection is imperative in order to minimize the effects of fluorescence and phosphorescence arising from the bombardment of particulate radiation in space.

Henderson, B. D.↗

Large-area multi-crystal NaI/Tl/ detectors for X-ray and gamma-ray astronomy

An array of large multicrystal NaI(Tl) detectors was constructed and used in a balloon-borne experiment to observe weak transient bursts of cosmic origin. The array had an active area of about 1 sq m and was sensitive to photons above 50 keV. Localized bursts which were observed are attributed to long-lived phosphorescence following large energy deposits by cosmic rays in the crystals.

Fishman, G. J.↗

Analysis and preliminary design of optical sensors for propulsion control

A fiber-optic sensor concept screening study was performed. Twenty sensor subsystems were identified and evaluated. Two concepts selected for further study were the Fabry-Perot fiber-optic temperature sensor and the pulse-width-modulated phosphorescent temperature sensor. Various designs suitable for a Fabry-Perot temperature sensor to be used as a remote fiber-optic transducer were investigated. As a result, a particular design was selected and constructed. Tests on this device show that spectral peaks are produced from visible white light, and the change in wavelength of the spectral peaks produced by a change in temperature is consistent with theory and is 36 nm/C for the first order peak. A literature search to determine a suitable phosphor for implementing the pulse-width-modulated fiber optic temperature sensor was conducted. This search indicated that such a device could be made to function for temperatures up to approximately 200 C. Materials like ZnCdS and ZnSe activated with copper will be particularly applicable to temperature sensing in the cryogenic to room temperature region. While this sensing concept is probably not applicable to jet engines, the simplicity and potential reliability make the concept highly desirable for other applications.

James, K. A.↗

Velocity visualization in gaseous flows

Techniques yielding simultaneous, multiple-point measurements of velocity in reacting or nonreacting flow fields have the potential to significantly impact basic and applied studies of fluid mechanics. This research program is aimed at investigating several candidate schemes which could provide such measurement capability. The concepts under study have in common the use of a laser source (to illuminate a column, a grid, a plane or a volume in the flow) and the collection of light at right angles (from Mie scattering, fluorescence, phosphorescence or chemiluminescence) using a multi-element solid-state camera (100 x 100 array of photodiodes). The work will include an overview and a status report of work in progress with particular emphasis on the method of Doppler-modulated absorption.

Hanson, R. K.↗

Velocity visualization in gaseous flows

Techniques are established for visualizing velocity in gaseous flows. Two approaches are considered, both of which are capable of yielding velocity simultaneously at a large number of flowfield locations, thereby providing images of velocity. The first technique employs a laser to mark specific fluid elements and a camera to track their subsequent motion. Marking is done by laser-induced phosphorescence of biacetyl, added as a tracer species in a flow of N2, or by laser-induced formation of sulfur particulates in SF6-H2-N2 mixtures. The second technique is based on the Doppler effect, and uses an intensified photodiode array camera and a planar form of laser-induced fluorescence to detect 2-d velocities of I2 (in I2-N2 mixtures) via Doppler-shifted absorption of narrow-linewidth laser radiation at 514.5 nm.

Hanson, R. K.↗

Flow velocity measurements by image processing of optically activated tracers

A computerized flow visualization technique capable of quantifying the flow field automatically has been developed. This technique uses afterglowing effect of optically activated phosphorescent particles to retrieve vectorial information on each trace. By using this information, in conjunction with computer image processing, the flow field of a free surface transient vortex was investigated.

Gharib, M.↗

Pregraphitic molecules and the red-rectangle emission

In light of the recent identification of an infrared emission band at 3.3, 6.2, 7.7, 8.6, and 11 microns as emissions from pregraphitic molecules, the possibility that a large broad emission bump in the red part of the spectrum of the Red-Rectangle (AFGL 918) nebula is luminescence from the same molecules was investigated. The abundance, luminescence yield of the carrier, and the phosphorescence is discussed.

Dhendecourt, L.↗

Measuring Fluid Velocities With Glowing Particles

Particle trajectories recorded photographically. Directions and magnitudes of velocities in unsteady liquid flow measured with aid of fluorescent- and phosphorescent-tracing technique. Method accurate and proceeds automatically, requiring minimal labor.

Gharib, M.↗

Camera artifacts in IUE low-dispersion spectra

Sky-background images obtained by the International Ultraviolet Explorer (IUE) were analyzed to study artificial spectral features (camera artifacts) in low-dispersion spectra. The artifacts mimic emission features and have been present in long-exposure spectra since the launch of the IUE satellite. The camera artifacts are strong in spectra characterized by long exposure times because they scale in time-integrated flux with the background level, which increases during the exposure due to camera phosphorescence. The artifacts cannot be detected in spectra obtained from short, direct exposures of flat-field lamps or standard stars. Plots of average sky-background spectra for the three operational IUE cameras (SWP, LWP, and LWR) are given to aid scientists in the identification of artifacts in their spectra.

Crenshaw, D. Michael↗

Luminescent barometry in wind tunnels

A flexible and relatively inexpensive method and apparatus are described for continuous pressure mapping of aerodynamic surfaces using photoluminescence and imaging techniques. Platinum octaethylporphyrin (PtOEP) has a phosphorescence known to be quenched by oxygen. When dissolved in a silicone matrix, PtOEP may be distributed over a surface as a thin, uniform film. When the film is irradiated with ultraviolet light, the luminescence intensity provides a readily detectable, qualitative surface flow visualization. Moreover, since the luminescence intensity is found to be inversely proportional to the partial pressure of oxygen, a quantitative measure of pressure change may be obtained using a silicon target vidicon or a charge-coupled device video sensor to measure intensity. Luminescent images are captured by a commercial frame buffer board. Images taken in wind tunnels during airflow are ratioed to images taken under ambient 'wind-off' conditions. The resulting intensity ratio information is converted to pressure using calibration curves of I0/I vs p/p0, where I0 is the intensity at ambient pressure p0 and I is the intensity at any other pressure p.

Kavandi, Janet↗

Photophysical behavior of doubly bridged d7-d7 metal-metal bonded compounds - The crystal structure and the excited- and ground-state electronic spectra of Re2(CO)6(dmpm)2 (dmpm = bis/dimethylphosphino/ methane)

Re2(CO)6(dmpm)2 shows photophysical behavior in a rigid medium that differs dramatically from that observed in fluid solution. In a hydrocarbon glass at 77 K, metal-metal bond homolysis is suppressed and an intense phosphorescence is observed. The transient absorption spectrum, which shows only weak transitions to the red of the ground state 1(sigma-sigma asterisk) transition, permits assignment of the emitting state to a 3(sigma-sigma asterisk) transition. The crystal structure of Re2(CO)6(dmpm)2 is also reported. The ground-state electronic structure is discussed relative to the structural data.

Milder, Steven J.↗

The role of matrix material and CCl4 (electron acceptor) on the ionization mechanisms of matrix-isolated naphthalene

The formation mechanisms and optical properties of polycyclic aromatic hydrocarbons (PAH) isolated in argon and neon matrices were studied in a systematic manner in an attempt to provide spectroscopic data on PAH ions under conditions relevant to astrophysical applications. The results obtained indicate the strong influence of the matrix material on the competing radiative (fluorescence and phosphorescence) and nonradiative (internal conversion and intersystem crossing) relaxation processes of the trapped molecule.

Salama, F.↗

Temperature dependence of electronic energy transfer and quenching in copolymer films of styrene and 2-(2'-hydroxy-5'-vinylphenyl)-2H-benzotriazole

Quenching of the emission of both the polystyrene monomer and the excimer for a series of varying composition copolymer films of styrene and 2-(2'-hydroxy-5'-vinylphenyl)-2H-benzotriazole is reported. The preponderance of quenching for both the monomer and excimer emissions is due to interception of the migrating excitation at the quencher site, although additional quenching results via long-range dipole-dipole energy transfer from the monomer and excimer traps to the quencher trap. The quenching of the monomer fluorescence and phosphorescence and that of the excimer fluorescence were found to be temperature independent over the ranges 14-58 and 191-296 K, respectively. Most significantly, it is concluded that the energy migration process is temperature independent over the range 14-296 K.

O'Connor, Donald B.↗

An automated pressure data acquisition system for evaluation of pressure sensitive paint chemistries

An automated pressure data acquisition system for testing of pressure sensitive phosphorescent paints was designed, assembled, and tested. The purpose of the calibration system is the evaluation and selection of pressure sensitive paint chemistries that could be used to obtain global aerodynamic pressure distribution measurements. The test apparatus and setup used for pressure sensitive paint characterizations is described. The pressure calibrations, thermal sensitivity effects, and photodegradation properties are discussed.

Sealey, Bradley S.↗

Luminescence of Eu(3+) doped SiO2 Thin Films and Glass Prepared by Sol-gel Technology

Trivalent europium ions are an important luminophore for lighting and display. The emission of (5)D0 to (7)F2 transition exhibits a red color at about 610 nm, which is very attractive and fulfills the requirement for most red-emitting phosphors including lamp and cathode ray phosphorescence materials. Various EU(3+) doped phosphors have been developed, and luminescence properties have been extensively studied. On the other hand, sol-gel technology has been well developed by chemists. In recent years, applications of this technology to optical materials have drawn a great attention. Sol-gel technology provides a unique way to obtain homogeneous composition distribution and uniform doping, and the processing temperature can be very low. In this work, EU(3+) doped SiO2 thin films and glasses were prepared by sol-gel technology and their spectroscopic properties were investigated.

Castro, Lymari↗

PSP Testing at NASA Ames Research Center

Pressure sensitive paints (PSPs) are now used routinely for measuring surface pressures on wind tunnel models at transonic and supersonic Mach numbers. The method utilizes a surface coating containing fluorescent or phosphorescent materials, the brightness of which varies with the local air pressure on the surface. The present paper will summarize PSP activities (in progress and planned) at the NASA Ames Research Center. One of the main accomplishments at NASA Ames has been the development of a PSP measurement system that is production testing capable. This system has been integrated successfully into the large-scale wind tunnel facilities at Ames. There are several problems related to PSP testing which are unique to large-scale wind tunnel testing. The hardware is often difficult to set-up and must operate under harsh conditions (e.g. high pressures and low temperatures). The data acquisition and reduction times need to be kept to a minimum so that the overall wind tunnel productivity is not compromised. The pressure sensitive paints needs to be very robust; the paints must readily adhere to different surfaces with varying geometries and remain functional for long running times. The paint must have well understood, and preferably minimal, temperature sensitivity since fine control of the tunnel temperature is not easily achievable in the larger wind tunnels. In an effort to improve the overall accuracy of the PSP technique, we are currently evaluating some referenced pressure sensitive paints which contain a pressure- independent luminophor in addition to the one which is affected by the surface pressure. The two luminophors are chosen so that their emission wavelengths are somewhat different. Then by taking two 'wind-on' images with either two cameras (with different filters) or one camera with a rotating filter system, the need for 'wind-off' images can be eliminated. The ratio of the two wind-on images accounts for nonuniform lighting and model motion problems (physical movement of the model under aerodynamic loading) are not a concern any more. The paints and data acquisition and reduction software for this type of a PSI system are currently under development and evaluation. Additional information is contained within the original extended abstract.

Bell, J. H.↗