Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “permanence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Design Study Of Cyclotron Magnet With Permanent Magnet

Low energy cyclotrons for Positron emission tomography (PET) have been wanted for the production of radio-isotopes after 2002. In the low energy cyclotron magnet design, increase of magnetic field between the poles is needed to make a smaller size of magnet and decrease power consumption. The Permanent magnet can support this work without additional electric power consumption in the cyclotron. In this paper the study of cyclotron magnet design using permanent magnet is shown and also the comparison between normal magnet and the magnet which is designed with permanent magnet is shown. Maximum energy of proton is 8 MeV and RF frequency is 79.3 MHz. 3D CAD design was done by CATIA P3 V5 R18 and the All field calculations had been performed by OPERA-3D TOSCA. The self-made beam dynamics program OPTICY is used for making isochronous field and other calculations.

43 PARTICLE ACCELERATORS↗

Compact Permanent Magnet Microwave-Driven Neutron Generator

Permanent magnet microwave-driven neutron generators have been developed at Lawrence Berkeley National Laboratory. The 2.45 GHz microwave signal is directly coupled into the plasma chamber via a microwave window. Plasma is confined in an axial magnetic field produced by the permanent magnets surrounding the plasma chamber. The source chamber is made of aluminum with a diameter of 4 cm and length of 5 cm. A stack of five alumina discs, which are 3 cm in diameter and total length of 3 cm, works as microwave window. Three permanent ring magnets are used to generate the axial magnetic field required for the microwave ion source. Both hydrogen and deuterium plasma have been successfully ignited. With 330W of microwave power, source chamber pressure of 5 mTorr, and an extraction aperture of 2 mm in diameter, the deuterium ion beam measured on the target was approximately 2.5 mA. Over 90% of the ions are atomic. With the ion source at ground potential and titanium target at -40 kV, the analysis of the activated gold foil and calibrated neutron dose monitor both indicated that roughly 10{sup 7} n/s of D-D neutrons have been produced. The D-D neutron yield can be easily scaled up to 10{sup 8} n/s when the titanium target is biased at -100 kV.

43 PARTICLE ACCELERATORS↗

Semihard Iron-Based Permanent-Magnet Materials

Permanent magnets generally require a favorable, but difficult-to-achieve combination of high magnetization, Curie point, and magnetic anisotropy. Thus there have been few, if any, viable permanent magnets developed since the 1982 discovery of Nd 2 Fe 14 B. In this work we point out, both by direct first-principles calculations on the iron carbides and silicides Fe 5 C 2 , Fe 5 SiC, and Fe 7 C 3 as well as a discussion of recent experimental findings, that there are numerous rare-earth-free iron-rich potential permanent-magnet materials with sufficient intrinsic magnetic properties to reasonably achieve room-temperature energy products of 20–25 MG Oe. This is substantially better than the performance of the best available rare-earth-free magnets based on ferrite, as well as shape-anisotropy-employing alnico. These magnets could plausibly fill, at low cost, the present performance “gap” between the best rare-earth-free magnets and rare-earth magnets such as Nd 2 Fe 14 B and Sm-Co.

36 MATERIALS SCIENCE↗

Design and development of permanent magnet based focusing lens for J-Band Klystron

Applying permanent magnet technology to beam focusing in klystrons can reduce their power consumption and increase their reliability of operation. Electromagnetic design of the beam focusing elements, for high frequency travelling wave tubes, is very critical. The magnitude and profile of the magnetic field need to match the optics requirement from beam dynamics studies. The rise of the field from cathode gun region to the uniform field region (RF section) is important as the desired transition from zero to peak axial field must occur over a short axial distance. Confined flow regime is an optimum choice to minimize beam scalloping but demands an axial magnetic field greater than 2 - 3 times the Brillouin flow field. This necessitates optimization in the magnet design achieve high magnetic field within given spatial constraints. Electromagnetic design and simulations were done using 3D Finite element method (FEM) analysis software. A permanent magnet based focusing lens for a miniature J-Band klystron has been designed and developed at Control Instrumentation Division, BARC. This paper presents the design, simulation studies, beam transmission and RF tests results for J Band klystron with permanent magnet focusing lens. (author)

43 PARTICLE ACCELERATORS↗

Demagnetization of Nd 2 Fe 14 B, Pr 2 Fe 14 B, and Sm 2 Co 17 Permanent Magnets in Spallation Irradiation Fields

Prompted by the need for radiation-resistant permanent magnets for insertion devices (IDs) of high-brilliance next-generation synchrotrons such as the National Synchrotron Light Source II, the demagnetization of Nd 2 Fe 14 B and Pr 2 Fe 14 B was studied after exposure to a mixed irradiating field. Degradation and damage of the permanent magnetic material by components of electromagnetic showers induced in magnets by intense high-energy electron beams will alter the magnetic field structure of the IDs. Plate-like Nd 2 Fe 14 B magnets were irradiated to 1.8 Grad dose and were evaluated against Pr 2 Fe 14 B magnets irradiated to a lower dose of 20 Mrad. In addition, annular Sm 2 Co 17 and Nd 2 Fe 14 B magnets integrated within a ferrofluidic feedthrough (FFFT) rotary seal were also irradiated to dose levels of 2 Grad for Sm 2 Co 17 and 20 Mrad for Nd 2 Fe 14 B. Post-irradiation measurements of the magnetic intensity revealed that severe demagnetization exceeding 85% occurs in Nd 2 Fe 14 B magnets after only 50 Mrad dose and over 87% for Pr 2 Fe 14 B after 10 Mrad dose. The annular-shaped Sm 2 Co 17 magnets of the FFFTs were almost insensitive to irradiation up to a dose of 2 Grad. Annular-shaped Nd 2 Fe 14 B magnets also showed resistance to demagnetization, a direct consequence of the annular shape which is characterized by the removal of the stronger demagnetizing field present at the center of a disk-like magnet. As a result, the sensitivity of boron-based permanent magnets to neutron energy (thermal versus fast) was also assessed via specifically designed experiments and discussed.

43 PARTICLE ACCELERATORS↗

Permanent-magnet energy spectrometer for electron beams from radiotherapy accelerators

Purpose: The purpose of this work was to adapt a lightweight, permanent magnet electron energy spectrometer for the measurement of energy spectra of therapeutic electron beams. Methods: An irradiation geometry and measurement technique were developed for an approximately 0.54-T, permanent dipole magnet spectrometer to produce suitable latent images on computed radiography (CR) phosphor strips. Dual-pinhole electron collimators created a 0.318-cm diameter, approximately parallel beam incident on the spectrometer and an appropriate dose rate at the image plane (CR strip location). X-ray background in the latent image, reduced by a 7.62-cm thick lead block between the pinhole collimators, was removed using a fitting technique. Theoretical energy-dependent detector response functions (DRFs) were used in an iterative technique to transform CR strip net mean dose profiles into energy spectra on central axis at the entrance to the spectrometer. These spectra were transformed to spectra at 95-cm source to collimator distance (SCD) by correcting for the energy dependence of electron scatter. The spectrometer was calibrated by comparing peak mean positions in the net mean dose profiles, initially to peak mean energies determined from the practical range of central-axis percent depth-dose (%DD) curves, and then to peak mean energies that accounted for how the collimation modified the energy spectra (recalibration). The utility of the spectrometer was demonstrated by measuring the energy spectra for the seven electron beams (7–20 MeV) of an Elekta Infinity radiotherapy accelerator. Results: Plots of DRF illustrated their dependence on energy and position in the imaging plane. Approximately 15 iterations solved for the energy spectra at the spectrometer entrance from the measured net mean dose profiles. Transforming those spectra into ones at 95-cm SCD increased the low energy tail of the spectra, while correspondingly decreasing the peaks and shifting them to slightly lower energies. Energy calibration plots of peak mean energy versus peak mean position of the net mean dose profiles for each of the seven electron beams followed the shape predicted by the Lorentz force law for a uniform z-component of the magnetic field, validating its being modeled as uniform (0.542 ± 0.027 T). Measured Elekta energy spectra and their peak mean energies correlated with the 0.5-cm (7–13 MeV) and the 1.0-cm (13–20 MeV) R{sub 90} spacings of the %DD curves. The full-width-half-maximum of the energy spectra decreased with decreasing peak mean energy with the exception of the 9-MeV beam, which was anomalously wide. Similarly, R{sub 80–20} decreased linearly with peak mean energy with the exception of the 9 MeV beam. Both were attributed to suboptimal tuning of the high power phase shifter for the recycled radiofrequency power reentering the traveling wave accelerator. Conclusions: The apparatus and analysis techniques of the authors demonstrated that an inexpensive, lightweight, permanent magnet electron energy spectrometer can be used for measuring the electron energy distributions of therapeutic electron beams (6–20 MeV). The primary goal of future work is to develop a real-time spectrometer by incorporating a real-time imager, which has potential applications such as beam matching, ongoing beam tune maintenance, and measuring spectra for input into Monte Carlo beam calculations.

60 APPLIED LIFE SCIENCES↗

Automated High Power Permanent Borehole Seismic Source Systems for Long-Term Monitoring of Subsurface CO2 Containment and Storage

The geologic storage of CO2 emitted from fixed sources, such as coal or gas power plants, is currently considered one of the prime technologies for short term (~50 year) mitigation of greenhouse gas emissions. The subsurface storage of CO2 for greenhouse gas mitigation will require monitoring to verify that CO2 remains effectively trapped underground, thus permanent seismic sources are needed to provide 24/7 monitoring. GPUSA Inc. has developed and successfully demonstrated numerous prototype vibratory seismic sources with power and performance far beyond any available on the market. The primary objective of this project was to validate in an operational field environment GPUSA’s powerful, low cost, automated borehole seismic source systems for the CO2 storage monitoring application. GPUSA originally proposed the building and testing of two types of permanent sources but ended up building and delivering three types of permanent seismic sources. These sources were delivered to the field test site (Carbon Management Canada’s Containment and Monitoring site near Calgary), however, only two of the systems were able to be tested before the contract ended (despite two contract extensions). The reasons for the delay were primarily weather related both at the US preliminary field test site and Carbon Management Canada site. But in the end, based upon the preliminary field testing in the US and the limited testing that was completed at the Carbon Management Canada site, the results were very impressive, and in some cases far exceeding expectations.

02 PETROLEUM↗

Summary of Results for Idaho Accelerator Center (IAC) Experiments with Compact Electron Permanent Magnet Spectrometer (CEPMS)

The Compact Electron Permanent Magnet Spectrometer (CEPMS) shown in Figure 2 consists of collimation at the electron beam entrance, a vacuum chamber for beam transport and a removable 60 degree sector magnet constructed by SABR Enterprises (Ref 2) that is used to momentum analyze the incoming electron beam. There are electron detection planes located perpendicular to straight through and the 60 degree trajectory ports. The planes are designed to accept phosphor screens for time integrated measurements. The screens can be replaced by scintillator for time resolved measurements using gated or streak cameras. The length of the spectrometer along the beamline without the collimator is about 400mm (14”). The spectrometer requires no power supply with controls for cycling or cooling for the magnet. The entire assembly, with magnet installed, weighs about 35kg (75lbs) Figure 3 depicts central and extreme trajectories through the spectrometer for various electron energies. The chamber accommodates a +/-50mm wide detection field relative to the center trajectory. Trajectories with larger momentum (energy) are bent the least. Since the permanent magnet slides off and on with reference to the upstream edge of the vacuum chamber, it can be adjusted to various positions to slightly increase or decrease the central energy thereby changing the range of available energies. Figure 4 shows the effect of changing the location of the permanent magnet on the electron trajectory. A small inward change in r produces a longer trajectory in the magnet therefore, the same energy trajectory is bent more.

43 PARTICLE ACCELERATORS↗

Additive Manufacturing of Isotropic NdFeB PPS Bonded Permanent Magnets

Extrusion based additive manufacturing of polymer composite magnets can increase the solid loading volume fraction with greater mechanical force through the printing nozzle as compared to traditional injection molding process. About 63 vol% of isotropic NdFeB magnet powders were compounded with 37 vol% of polyphenylene sulfide and bonded permanent magnets were fabricated while using Big Area Additive Manufacturing without any degradation in magnetic properties. The polyphenylene sulfide bonded magnets have a tensile stress of 20 MPa, almost double than that of nylon bonded permanent magnets. Additively manufactured and surface-protective-resin coated bonded magnets meet the industrial stability criterion of up to 175 °C with a flux-loss of 2.35% over 1000 h. They also exhibit better corrosion resistance behavior when exposed to acidic (pH = 1.35) solution for 24 h and also annealed at 80 °C over 100 h (at 95% relative humidity) over without coated magnets. Thus, polyphenylene sulfide bonded, additively manufactured, protective resin coated bonded permanent magnets provide better thermal, mechanical, and magnetic properties.

36 MATERIALS SCIENCE↗

Permanent Magnet Skew Quadrupoles for the Low Emittance LER Lattice of PEP-II

The vertical emittance of the low energy ring (LER) in the PEP-II B-Factory was reduced by using skew quadrupoles consisting of permanent magnet material. The advantages over electric quadrupoles or rotating existing normal quadrupoles are discussed. To assure a high field quality, a Biot-Savart calculation was used to cancel the natural 12-pole component by using different size poles over a few layers. A magnetic measurement confirmed the high quality of the magnets. After installation and adjusting the original electric 12 skew and 16 normal quadrupoles the emittance contribution from the region close to the interaction point, which was the biggest part in the original design, was considerably reduced. To strengthen the vertical behavior of the LER beam, a low emittance lattice was developed. It lowered the original vertical design emittance from 0.54 nm-rad to 0.034 nm-rad. In order to achieve this, additional skew quadrupoles were required to bring the coupling correction out of the arcs and closer to the detector solenoid in the straight (Fig. 1). It is important, together with low vertical dispersion, that the low vertical emittance is not coupled into the horizontal, which is what we get if the coupling correction continues into the arcs. Further details of the lattice work is described in another paper; here we concentrate on the development of the permanent skew (PSK) quadrupole solution. Besides the permanent magnets there are two other possibilities, using electric magnets or rotating normal quadrupoles. Electric magnets would have required much more additional equipment like magnets stands, power supply, and new vacuum chamber sections. Rotating existing quadrupoles was also not feasible since they are mostly mounted together with a bending magnet on the same support girder.

43 PARTICLE ACCELERATORS↗

Perspectives on Permanent Magnetic Materials for Energy Conversion and Power Generation

Permanent magnet development has historically been driven by the need to supply larger magnetic energy in ever smaller volumes for incorporation in an enormous variety of applications that include consumer products, transportation components, military hardware, and clean energy technologies such as wind turbine generators and hybrid vehicle regenerative motors. Since the 1960s, the so-called rare-earth "supermagnets," composed of iron, cobalt, and rare-earth elements such as Nd, Pr, and Sm, have accounted for the majority of global sales of high-energy-product permanent magnets for advanced applications. In rare-earth magnets, the transition-metal components provide high magnetization, and the rare-earth components contribute a very large magnetocrystalline anisotropy that donates high resistance to demagnetization. However, at the end of 2009, geopolitical influences created a worldwide strategic shortage of rare-earth elements that may be addressed, among other actions, through the development of rare-earth-free magnetic materials harnessing sources of magnetic anisotropy other than that provided by the rare-earth components. Materials engineering at the micron scale, nanoscale, and Angstrom scales, accompanied by improvements in the understanding and characterization of nanoscale magnetic phenomena, is anticipated to result in new types of permanent magnetic materials with superior performance. DOI: 10.1007/s11661-012-1278-2 (C) The Minerals, Metals & Materials Society and ASM International 2012

Lewis, LH↗

Compression Molding and Novel Sintering Treatments for Alnico Type-8 Permanent Magnets in Near-Final Shape with Preferred Orientation

We present economic uncertainty in the rare earth (RE) permanent magnet marketplace, as well as in an expanding electric drive vehicle market that favors permanent magnet alternating current synchronous drive motors, motivated renewed research in RE-free permanent magnets like “alnico,” an Al-Ni-Co-Fe alloy. Thus, high-pressure, gas-atomized isotropic type-8H pre-alloyed alnico powder was compression molded with a clean burn-out binder to near-final shape and sintered to density >99% of cast alnico 8 (full density of 7.3 g/cm 3 ). To produce aligned sintered alnico magnets for improved energy product and magnetic remanence, uniaxial stress was attempted to promote controlled grain growth, avoiding directional solidification that provides alignment in alnico 9. Lastly, successful development of solid-state powder processing may enable anisotropically aligned alnico magnets with enhanced energy density to be mass-produced.

36 MATERIALS SCIENCE↗

Low-Field Alignment of Anisotropic Bonded Magnets for Additive Manufacturing of Permanent Magnet Motors

Additive manufacturing techniques for fabricating bonded magnets have the potential to reduce manufacturing cost and time-to-market of products and address the criticality of rare-earth elements (REEs), which is a concern for economic design of dependent applications such as permanent magnet machines. We investigated the magnetic alignment of anisotropic bonded magnet material comprising 65 vol.% Nd-Fe-B in nylon-12 produced by extrusion in a 20-W brushless direct current surface permanent magnet motor for submersible water pump application using finite element analysis. The results predict that sufficient alignment for this application could be obtained at low alignment fields (μoH ≤ 1 T) with a reduction in the volume of critical materials by up to 40% compared with isotropic permanent magnets. Furthermore, this demonstrates the economic feasibility of incorporating a magnetic alignment field source into additive manufacturing systems for bonded magnets, and the potential of aligned anisotropic bonded magnets to address REE criticality.

36 MATERIALS SCIENCE↗

Phase I Trial of Gross Total Resection, Permanent Iodine-125 Brachytherapy, and Hyperfractionated Radiotherapy for Newly Diagnosed Glioblastoma Multiforme

Purpose: To evaluate the feasibility of gross total resection and permanent I-125 brachytherapy followed by hyperfractionated radiotherapy for patients with newly diagnosed glioblastoma. Methods and Materials: From April 1999 to May 2002, 21 patients with glioblastoma multiforme were enrolled on a Phase I protocol investigating planned gross total resection and immediate placement of permanent I-125 seeds, followed by postoperative hyperfractionated radiotherapy to a dose of 60 Gy at 100 cGy b.i.d., 5 days per week. Median age and Karnofsky performance status were 50 years (range, 32-65 years) and 90 (range, 70-100), respectively. Toxicity was assessed according to Radiation Therapy Oncology Group criteria. Results: Eighteen patients completed treatment according to protocol. The median preoperative tumor volume on magnetic resonance imaging was 18.6 cm{sup 3} (range, 4.4-41.2 cm{sup 3}). The median brachytherapy dose measured 5 mm radially outward from the resection cavity was 400 Gy (range, 200-600 Gy). Ten patients underwent 12 reoperations, with 11 of 12 reoperations demonstrating necrosis without evidence of tumor. Because of high toxicity, the study was terminated early. Median progression-free survival and overall survival were 57 and 114 weeks, respectively, but not significantly improved compared with historical patients treated at University of California, San Francisco, with gross total resection and radiotherapy without brachytherapy. Conclusions: Treatment with gross total resection and permanent I-125 brachytherapy followed by hyperfractionated radiotherapy as performed in this study results in high toxicity and reoperation rates, without demonstrated improvement in survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Customized Dose Prescription for Permanent Prostate Brachytherapy: Insights From a Multicenter Analysis of Dosimetry Outcomes

Purpose: To investigate the biochemical control rate in patients undergoing permanent prostate brachytherapy as a function of the biologically effective dose (BED) and risk group. Methods and Materials: Six centers provided data on 3,928 permanent brachytherapy patients with postimplant dosimetry results. The mean prostate-specific antigen level was 8.9 ng/mL. {sup 125}I was used in 2,293 (58%), {sup 103}Pd in 1,635, and supplemental external beam radiotherapy in 882 (22.5%) patients. The patients were stratified into low- (n = 2,188), intermediate- (n = 1,188), and high- (n = 552) risk groups and into three BED groups of < 140 Gy (n = 524), 140-200 Gy (n = 2284), and >200 Gy (n = 1,115). Freedom from biochemical disease progression (biochemical freedom from failure [bFFF]) was determined using the American Society for Therapeutic Radiology Oncology and Phoenix definitions and calculated using the Kaplan-Meier method, with factors compared using the log-rank test. Results: The 10-year prostate-specific antigen bFFF rate for the American Society for Therapeutic Radiology Oncology and Phoenix definitions was 79.2% and 70%, respectively. The corresponding bFFF rates for the low-, intermediate-, and high-risk groups was 84.1% and 78.1%, 76.8% and 63.6%, and 64.4% and 58.2%, respectively (p < 0.0001). The corresponding bFFF rate for the three BED groups was 56.1% and 41.4%, 80% and 77.9%, and 91.1% and 82.9% (p < 0.0001). The corresponding bFFF rate for the low-risk patients by dose group was 69.8% and 49.8%, 86% and 85.2%, and 88.1% and 88.3% for the low-, intermediate, and high-dose group, respectively (p <0.0001). The corresponding bFFF rate for the intermediate-risk patients by dose group was 52.9% and 23.1%, 74.1% and 77.7%, and 94.3% and 88.8% for the low-, intermediate-, and high-dose group, respectively (p < 0.0001). The corresponding bFFF rate for high-risk patients by dose group was 19.2% and 41.7%, 61.8% and 53.2%, and 90% and 69.6% for the low-, intermediate-, and high-dose group, respectively (p < 0.0001). Conclusions: These data suggest that permanent brachytherapy dose prescriptions can be customized to risk status. In low-risk patients, achieving a BED of {>=}140 Gy might be adequate for prostate-specific antigen control. However, high-risk disease might require a BED dose of {>=}200 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postimplantation Analysis Enables Improvement of Dose-Volume Histograms and Reduction of Toxicity for Permanent Seed Implantation

Purpose: To demonstrate how postimplantation analysis is useful for improving permanent seed implantation and reducing toxicity. Patients and Methods: We evaluated 197 questionnaires completed by patients after permanent seed implantation (monotherapy between 1999 and 2003). For 70% of these patients, a computed tomography was available to perform postimplantation analysis. The index doses and volumes of the dose-volume histograms (DVHs) were determined and categorized with respect to the date of implantation. Differences in symptom scores relative to pretherapeutic status were analyzed with regard to follow-up times and DVH descriptors. Acute and subacute toxicities in a control group of 117 patients from an earlier study (June 1999 to September 2001) by Wust et al. (2004) were compared with a matched subgroup from this study equaling 110 patients treated between October 2001 and August 2003. Results: Improved performance, identifying a characteristic time dependency of DVH parameters (after implantation) and toxicity scores, was demonstrated. Although coverage (volume covered by 100% of the prescription dose of the prostate) increased slightly, high-dose regions decreased with the growing experience of the users. Improvement in the DVH and a reduction of toxicities were found in the patient group implanted in the later period. A decline in symptoms with follow-up time counteracts this gain of experience and must be considered. Urinary and sexual discomfort was enhanced by dose heterogeneities (e.g., dose covering 10% of the prostate volume, volume covered by 200% of prescription dose). In contrast, rectal toxicities correlated with exposed rectal volumes, especially the rectal volume covered by 100% of the prescription dose. Conclusion: The typical side effects occurring after permanent seed implantation can be reduced by improving the dose distributions. An improvement in dose distributions and a reduction of toxicities were identified with elapsed time between 1999 and 2003.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multicenter Analysis of Effect of High Biologic Effective Dose on Biochemical Failure and Survival Outcomes in Patients With Gleason Score 7-10 Prostate Cancer Treated With Permanent Prostate Brachytherapy

Purpose: To investigate the biochemical control rates and survival for Gleason score 7-10 prostate cancer patients undergoing permanent prostate brachytherapy as a function of the biologic effective dose (BED). Methods and Materials: Six centers provided data on 5,889 permanent prostate brachytherapy patients, of whom 1,078 had Gleason score 7 (n = 845) or Gleason score 8-10 (n = 233) prostate cancer and postimplant dosimetry results available. The median prostate-specific antigen level was 7.5 ng/mL (range, 0.4-300). The median follow-up for censored patients was 46 months (range, 5-130). Short-term hormonal therapy (median duration, 3.9 months) was used in 666 patients (61.8%) and supplemental external beam radiotherapy (EBRT) in 620 (57.5%). The patients were stratified into three BED groups: <200 Gy (n = 645), 200-220 Gy (n = 199), and >220 Gy (n = 234). Biochemical freedom from failure (bFFF) was determined using the Phoenix definition. Results: The 5-year bFFF rate was 80%. The bFFF rate stratified by the three BED groups was 76.4%, 83.5%, and 88.3% (p < 0.001), respectively. Cox regression analysis revealed Gleason score, prostate-specific antigen level, use of hormonal therapy, EBRT, and BED were associated with bFFF (p < 0.001). Freedom from metastasis improved from 92% to 99% with the greatest doses. The overall survival rate at 5 years for the three BED groups for Gleason score 8-10 cancer was 86.6%, 89.4%, and 94.6%, respectively (p = 0.048). Conclusion: These data suggest that permanent prostate brachytherapy combined with EBRT and hormonal therapy yields excellent bFFF and survival results in Gleason score 7-10 patients when the delivered BEDs are >220 Gy. These doses can be achieved by a combination of 45-Gy EBRT with a minimal dose received by 90% of the target volume of 120 Gy of {sup 103}Pd or 130 Gy of {sup 125}I.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of an RTOG Phase II Trial (00-19) of External-Beam Radiation Therapy Combined With Permanent Source Brachytherapy for Intermediate-Risk Clinically Localized Adenocarcinoma of the Prostate

Purpose: External-beam radiation therapy combined with low-doserate permanent brachytherapy are commonly used to treat men with localized prostate cancer. This Phase II trial was performed to document late gastrointestinal or genitourinary toxicity as well as biochemical control for this treatment in a multi-institutional cooperative group setting. This report defines the long-term results of this trial. Methods and Materials: All eligible patients received external-beam radiation (45 Gy in 25 fractions) followed 2-6 weeks later by a permanent iodine 125 implant of 108 Gy. Late toxicity was defined by the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late radiation morbidity scoring scheme. Biochemical control was defined by the American Society for Therapeutic Radiology and Oncology (ASTRO) Consensus definition and the ASTRO Phoenix definition. Results: One hundred thirty-eight patients were enrolled from 20 institutions, and 131 were eligible. Median follow-up (living patients) was 8.2 years (range, 2.7-9.3 years). The 8-year estimate of late grade >3 genitourinary and/or gastrointestinal toxicity was 15%. The most common grade >3 toxicities were urinary frequency, dysuria, and proctitis. There were two grade 4 toxicities, both bladder necrosis, and no grade 5 toxicities. In addition, 42% of patients complained of grade 3 impotence (no erections) at 8 years. The 8-year estimate of biochemical failure was 18% and 21% by the Phoenix and ASTRO consensus definitions, respectively. Conclusion: Biochemical control for this treatment seems durable with 8 years of follow-up and is similar to high-dose external beam radiation alone or brachytherapy alone. Late toxicity in this multi-institutional trial is higher than reports from similar cohorts of patients treated with high-dose external-beam radiation alone or permanent low-doserate brachytherapy alone, perhaps suggesting further attention to strategies that limit doses to normal structures or to unimodal radiotherapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗