Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance loss rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Optimal filtering and generation of entangled photons for quantum applications in the presence of noise

Filtering is commonly used in quantum optics to reject noise photons, and also to enable interference between independent photons. However, filtering the joint spectrum of photon pairs can reduce the inherent coincidence probability or loss-independent heralding efficiency. Here we investigate filtering for multiphoton applications based on entanglement and interference (e.g., quantum teleportation). We multiplex C-band entangled photons and C-band classical communications into the same long-distance fibers, which enables scalable low-loss quantum networking but requires filtering of spontaneous Raman scattering noise from classical light. Using tunable-bandwidth filters, low-jitter detectors, and polarization filters, we distribute wavelength-degenerate time-bin entangled photons in the C band (1536.5 nm) over 25 km/25 km standard fibers (50 km) each carrying 10 Gbit/s C-band classical data signals. Narrow filtering enables milliwatt-level C-band power, which exceeds the power achieved by comparable studies by roughly an order of magnitude and could feasibly support terabit per second classical rates. We evaluate how performance depends on pump and filter bandwidths, multipair emission, filter shapes, loss, phase matching, and how quantum information is measured. We find a trade-off between reducing noise impact and increasing single-mode purity, and discuss mitigation methods toward optimal multiphoton applications. Importantly, these results apply to noise in free space and in quantum devices (sources, frequency converters, switches, detectors, etc.) and provide insight into filter-induced degradation of single-photon purity and rates even in noise-free environments.

Thomas, Jordan M. [Fermilab; Northwestern U.]↗

Electronic Structure and Safety Insights into Prussian Blue Analog Cathode Behavior at Elevated Temperatures in Sodium-Ion Batteries

Prussian blue analogs (PBAs) represent promising cathode materials for sodium-ion batteries (SIBs) due to their high theoretical capacity, open framework structure, and use of earth-abundant elements. However, the high-temperature structural evolution, water content effects, and thermal safety of PBAs, particularly in charged states, remain poorly understood, hindering their practical deployment. Here, we investigate Na 2 Fe[Fe(CN) 6 ]·2H 2 O using thermogravimetric analysis (TGA), ex situ and in situ temperature-dependent X-ray absorption spectroscopy (XAS), and accelerated rate calorimetry (ARC). TGA and ex situ XAS confirm water loss between 150 and 200 °C, resulting in Fe 2+ oxidation, enhanced local symmetry, and uniform redox behavior that improves electrochemical performance. In situ XAS reveals irreversible structural changes above 240 °C, including ligand loss, Fe site distortion, and increased disorder, while ARC on charged electrodes shows minimal self-heating rates (<0.1 °C/min) up to 300 °C, indicating exceptional thermal stability without lattice oxygen release. These insights elucidate PBA thermal dynamics, demonstrating improved electrochemical performance of water-deficient PBAs and informing future material design and safety assessment for SIB applications.

batteries↗

[Activities of Bay Area Research Corporation]

During the final year of this effort the HALFSHEL code was converted to work on a fast single processor workstation from it s parallel configuration. This was done because NASA Ames NAS facility stopped supporting space science and we no longer had access to parallel computer time. The single processor version of HALFSHEL was upgraded to address low density cells by using a a 3-D SOR solver to solve the equation Delta central dot E = 0. We then upgraded the ionospheric load packages to provide a multiple species load of the ionosphere out to 1.4 Rm. With these new tools we began to perform a series of simulations to address the major topic of this research effort; determining the loss rate of O(sup +) and O2(sup +) from Mars. The simulations used the nominal Parker spiral field and in one case used a field perpendicular to the solar wind flow. The simulations were performed for three different solar EUV fluxes consistent with the different solar evolutionary states believed to exist before today. The 1 EUV case is the nominal flux of today. The 3 EUV flux is called Epoch 2 and has three times the flux of todays. The 6 EUV case is Epoch 3 and has 6 times the EUV flux of today.

Source record↗

Space Suit Radiator Performance in Lunar and Mars Environments

During an ExtraVehicular Activity (EVA), both the heat generated by the astronaut's metabolism and that produced by the Portable Life Support System (PLSS) must be rejected to space. The heat sources include the heat of adsorption of metabolic CO2, the heat of condensation of water, the heat removed from the body by the liquid cooling garment and the load from the electrical components. Although the sublimator hardware to reject this load weighs only 3.48 lbs, an additional eight pounds of water are loaded into the unit of which about six to eight are sublimated and lost; this is the single largest expendable during an eight-hour EVA. Using a radiator to reject heat from the Astronaut during an EVA, we can significantly reduce the amount of expendable water consumed by the sublimator. Last year we reported on the design and initial operational assessment tests of our novel radiator designated the Radiator And Freeze Tolerant heat eXchanger (RAFT-X). Herein, we report on tests conducted in the NASA Johnson Space Center Chamber E Thermal Vacuum Test Facility. Up to 800 Btu/h of heat were rejected in lunar and Mars environments with temperatures as cold as 150 F. Tilting the radiator did not cause an observable loss in performance. The RAFT-X endured freeze/thaw cycles and in fact, the heat exchanger was completely frozen three times without any apparent damage to the unit. We were also able to operate the heat exchanger in a partially frozen configuration to throttle the heat rejection rate from 530 Btu/h at low water flow rate down to 300 Btu/h. Finally, the deliberate loss of a single loop heat pipe only degraded the heat rejection performance by about 2 to 5%.

Paul, Heather↗

A Nomographic Methodology for Use in Performance Trade-Off Studies of Parabolic Dish Solar Power Modules

A simple graphical method was developed to undertake technical design trade-off studies for individual parabolic dish models comprising a two-axis tracking parabolic dish with a cavity receiver and power conversion assembly at the focal point. The results of these technical studies are then used in performing the techno-economic analyses required for determining appropriate subsystem sizing. Selected graphs that characterize the performance of subsystems within the module were arranged in the form of a nomogram that would enable an investigator to carry out several design trade-off studies. Key performance parameters encompassed in the nomogram include receiver losses, intercept factor, engine rating, and engine efficiency. Design and operation parameters such as concentrator size, receiver type (open or windowed aperture), receiver aperture size, operating temperature of the receiver and engine, engine partial load characteristics, concentrator slope error, and the type of reflector surface, are also included in the graphical solution. Cost considerations are not included.

Selcuk, M. K.↗

Effect of precipitation on wind turbine performance

The effects of precipitation on wind turbine power output was analyzed. The tests were conducted on the two bladed Mod-0 horizontal axis wind turbine with three different rotor configurations. Experimental data from these tests are presented which clearly indicate that the performance of the Mod-0 wind turbine is affected by rain. Light rainfall degraded performance by as much as 20 percent while heavy rainfall degraded performance by as much as 30 percent. Snow mixed with drizzle degraded performance by as much as 36 percent at low windspeeds. Also presented are the results of an analysis to predict the effect of rain on wind turbine performance. This analysis used a blade element/momentum code with modified airfoil characteristics to account for the effect of rain and predicted a loss in performance of 31 percent in high winds with moderate rainfall rates. These predicted results agreed well with experimental data.

Corrigan, R. D.↗

Engine panel seals for hypersonic engine applications: High temperature leakage assessments and flow modelling

A critical mechanical system in advanced hypersonic engines is the panel-edge seal system that seals gaps between the articulating horizontal engine panels and the adjacent engine splitter walls. Significant advancements in seal technology are required to meet the extreme demands placed on the seals, including the simultaneous requirements of low leakage, conformable, high temperature, high pressure, sliding operation. In this investigation, the seal concept design and development of two new seal classes that show promise of meeting these demands will be presented. These seals include the ceramic wafer seal and the braided ceramic rope seal. Presented are key elements of leakage flow models for each of these seal types. Flow models such as these help designers to predict performance-robbing parasitic losses past the seals, and estimate purge coolant flow rates. Comparisons are made between measured and predicted leakage rates over a wide range of engine simulated temperatures and pressures, showing good agreement.

Steinetz, Bruce M.↗

Space Suit Radiator Performance in Lunar and Mars Environments

During an ExtraVehicular Activity (EVA), both the heat generated by the astronaut's metabolism and that produced by the Portable Life Support System (PLSS) must be rejected to space. The heat sources include the heat of adsorption of metabolic CO2, the heat of condensation of water, the heat removed from the body by the liquid cooling garment and the load from the electrical components. Although the sublimator hardware to reject this load weighs only 3.48 lbs, an additional eight pounds of water are loaded into the unit of which about six to eight are sublimated and lost; this is the single largest expendable during an eight-hour EVA. Using a radiator to reject heat from the Astronaut during an EVA, we can significantly reduce the amount of expendable water consumed by the sublimator. Last year we reported on the design and initial operational assessment tests of our novel radiator designated the Radiator And Freeze Tolerant heat eXchanger (RAFT-X). Herein, we report on tests conducted in the NASA Johnson Space Center Chamber E Thermal Vacuum Test Facility. Up to 800 Btu/h of heat were rejected in lunar and Mars environments with temperatures as cold as -150 F. Tilting the radiator did not cause an observable loss in performance. The RAFT-X endured freeze / thaw cycles and in fact, the heat exchanger was completely frozen three times without any apparent damage to the unit. We were also able to operate the heat exchanger in a partially frozen configuration to throttle the heat rejection rate from 530 Btu/h at low water flow rate down to 300 Btu/h. Finally, the deliberate loss of a single loop heat pipe only degraded the heat rejection performance by about 2 to 5%.

Nabity, James↗

A Comparison of Two Terminal Area Detect and Avoid Well Clear Definitions

Technical requirements are currently under development for a detect and avoid system (DAA) that would support the operation of Unmanned Aircraft Systems (UAS) within the National Airspace System (NAS). Such a system would aid UAS operators in maintaining sufficient separation, or "well clear", from other aircraft in their vicinity. The first set of technical standards for a UAS DAA system (referred to as "Phase 1" requirements) was limited to UAS operations transiting through Class D, E, and G airspace to, or from, Class A (or special-use) airspace. Explicitly out of scope of the Phase 1 requirements was the operation of UAS within terminal airspace in the NAS. Fern, Rorie, Roberts and Monk (2018) explored the application of a Phase 1 DAA system within Class D terminal airspace in a human-in-the-loop simulation. The results of the study demonstrated a poor fit of the Phase 1 DAA well clear (DWC) definition to these terminal operations. The original DWC definition was designed for the en-route environment and could not account for the complex, tightly-choreographed nature of traffic typically found near an airport. The interaction of the en-route DWC definition and the terminal area traffic led to excessive DAA alerting against safely-separated traffic. The frequent alerting quickly degraded pilots' ability to discriminate between encounters where a maneuver was or was not necessary. This resulted in slower response times, higher rates of losses of DAA well clear, and more severe losses of DAA well clear than had been observed in previous DAA research (e.g., Rorie et al., 2017). The current paper reports on a follow-on study to Fern et al. (2018) that tested two DWC definitions designed to accommodate standard terminal area operating procedures, such as traffic in the downwind leg of a VFR traffic pattern while the UAS is on final. The two definitions utilized identical horizontal and vertical thresholds but differed in whether or not Tau (a function that takes into account the closure rate of two aircraft) was included as a part of the DWC hazard zone. The "Tau" DWC candidate definition nominally extended the DWC hazard zone by 15 seconds in the direction of the intruder aircraft, while the "No Tau" DWC candidate definition did not extend the DWC hazard zone. The results of this follow-on study indicated that both candidate definitions improved pilot and DAA system performance relative to Fern et al (2018). Pilot response times and rates of losses of DWC returned to levels comparable to earlier research in the en-route environment. Several important differences between the two DWC candidate definitions, however, are also discussed.

Terminal Area↗

Photovoltaic Cleaning Frequency Optimization Under Different Degradation Rate Patterns

Dust accumulation significantly affects the performance of photovoltaic modules and its impact can be mitigated by various cleaning methods. Optimizing the cleaning frequency is essential to minimize the soiling losses and, at the same time, the costs. However, the effectiveness of cleaning lowers with time because of the reduced energy yield due to degradation. Additionally, economic factors such as the escalation in electricity price and inflation can compound or counterbalance the effect of degradation on the soiling mitigation profits. The present study analyzes the impact of degradation, escalation in electricity price and inflation on the revenues and costs of cleanings and proposes a methodology to maximize the profits of soiling mitigation of any system. Here, the energy performance and soiling losses of a 1 MW system installed in southern Spain were analyzed and integrated with theoretical linear and nonlinear degradation rate patterns. The Levelized Cost of Energy and Net Present Value were used as criteria to identify the optimum cleaning strategies. The results showed that the two metrics convey distinct cleaning recommendations, as they are influenced by different factors. For the given site, despite the degradation effects, the optimum cleaning frequency is found to increase with time of operation.

14 SOLAR ENERGY↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Wells RWM 6 and RWM 7

Hydrologic tests were conducted on the Lost Lake Aquifer Zone (LLAZ) at recovery wells RWM 6 and RWM 7 in accordance with the approved test plan (Dixon, 2023). The objective of the testing was to determine well performance parameters of RWM 6 and aquifer hydraulic properties near RWM 6 and RWM 7. Tests at RWM 6 consisted of a step-drawdown test to determine well performance parameters, a constant rate pump test to determine aquifer hydraulic properties, and an aquifer recovery test also used to determine aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. Prior to testing at RWM 6, a constant rate pump test was conducted at RWM 7. Data from this testing was used to determine aquifer hydraulic properties near RWM 7.

42 ENGINEERING↗

Parametric analysis of anodic degradation mechanisms for fast charging lithium batteries with graphite anode

In this work, we report the impact of the temperature-driven synergistically-coupled anodic degradation mechanisms on the electrochemical performance of lithium batteries with graphite anode over multiple cycles. Temperature dependence of electrochemical reactions and damage mechanisms, such as solid electrolyte interface (SEI) growth, lithium plating/stripping, dead lithium storage/dissolution, and film cracking are incorporated into the degradation model. Results of a parametric analysis are presented, evaluating the effects of charging rates (1–6 C), operating temperatures (-15 – 45°C) and electrode design parameters, on the relative performance fade in the lithium-ion battery. Thermo-electrochemical process maps are developed to provide insights into the relationship between electrode performance and failure mechanisms. The simulation results predict a severe capacity loss due to lithium plating at low temperatures, which is further aggravated at high charging rates. A common strategy for mitigating lithium plating, through charging at high temperatures, also results in rapid capacity loss due to accelerated SEI formation. Simulation results are used to identify the combination of operating conditions and electrode design parameters that improve the electrochemical performance of the battery. These results demonstrate an opportunity to design safe and high-performance lithium-ion batteries, guided by anodic degradation models.

Battery design↗

Performance of large-bore tapered-roller bearings under combined radial and thrust load at shaft speeds to 15,000 rpm

The performance of 120.65-mm bore tapered roller bearings was investigated at shaft speeds up to 15,000 rpm. Temperature distribution and bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rate, and lubricant inlet temperature. Lubricant was supplied by either jets or by a combination of holes through the cone directly to the cone-rib contact and jets at the roller small-end side. Cone-rib lubrication significantly improved high-speed tapered-roller bearing performance, yielding lower cone-face temperatures and lower power loss and allowing lower lubricant flow rates for a given speed condition. Bearing temperatures increased with increased shaft speed and decreased with increased lubricant flow rate. Bearing power loss increased with increased shaft speed and increased lubricant flow rate.

Parker, R. J.↗

Lubrication of high-speed, large bore tapered-roller bearings

The performance of 120.65-mm- (4.75-in.-) bore tapered-roller bearings was investigated at shaft speeds up to 15,000 rpm (18,000 DN). Temperature distribution and bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rate, and lubricant inlet temperature. Lubricant was supplied either by jets or by a combination of holes through the cone directly to the cone-rib contact and jets at the roller small-end side. Cone-rib lubrication significantly improved high-speed tapered-roller bearing performance, yielding lower cone-face temperatures and lower power loss and allowing lower lubricant flow rates for a given speed condition. Bearing temperatures increased with increased shaft speed and decreased with increased lubricant flow rate. Bearing power loss increased with increased shaft speed and increased lubricant flow rate.

Parker, R. J.↗

Lubrication of high-speed, large bore tapered-roller bearings

The performance of 120.65-mm bore tapered-roller bearings was investigated at shaft speeds up to 15,000 rpm. Temperature distribution and bearing heat generation were determined as a function of shaft speed, radial and thrust loads, lubricant flow rate, and lubricant inlet temperature. Lubricant was supplied either by jets or by a combination of holes through the cone directly to the cone-rib contact and jets at the roller small-end side. Cone-rib lubrication significantly improved high-speed tapered-roller bearing performance, yielding lower cone-face temperatures and lower power loss and allowing lower lubricant flow rates for a given speed condition. Bearing temperatures increased with increased shaft speed and decreased with increased lubricant flow rate. Bearing power loss increased with increased shaft speed and increased lubricant flow rate.

Parker, R. J.↗

Photovoltaic module antireflection coating degradation survey using color microscopy and spectral reflectance

Abstract Commercial antireflective coatings (ARCs) on photovoltaic (PV) module glass can improve module power by 2.5%–3.0%, but their long‐term field performance requires additional study. In this paper, we investigate ARC performance on fielded modules using two nondestructive techniques: reflectance spectroscopy and RGB microscopy, finding a large variation in coating durability and performance. For new coatings, the fleet average nominal power enhancement is 2.8%. This power enhancement is observed to degrade at approximately −0.05%/year absolute over the first 8 years of fielding in arrays that are not regularly cleaned. Interferometry and imaging results imply that coating loss for these modules is due to slow chemical thinning of the initial 125 nm thick coating by 1.4 to 5.0 nm/year. Due to the physics of interference coatings, the performance loss is projected to accelerate as the coating is further thinned, resulting in a coating lifetime (time to 80% of initial performance) of 7.5 to 25 years. At the higher 5.0 nm/year coating loss rates, we estimate that −0.14%/year power degradation of the module can be attributed solely to ARC degradation over the first 20 years. Extreme coating loss is observed on some modules where after 8 years fielding, the coating can be completely removed with a single wet wipe with a lens tissue. A case study is also presented comparing ARC and noncoated modules installed at a single site in 2013. We find that the ARC modules have a 2.6% higher soiling power loss than the noncoated modules; this exceeds the ARC power enhancement of 2.4% and leads to the surprising conclusion that the ARC lowers production for modules in this location due to increased soiling. These results demonstrate that RGB microscopy is a powerful, field‐capable, and quantitative characterization technique for assessing degradation of PV module ARCs.

Karin, Todd↗

Optimization of target lifetime for production of 14 MeV neutrons

Two methods are examined for extending the life of tritium targets for production of 14 MeV neutrons by the 3 H( 2 H,n) 4 He nuclear reaction. With thick film targets the neutron production rate decreases with time due to isotope exchange of tritium in the film with implanted deuterium. Here, the target life is maximized by operating the target at elevated temperature where the implanted deuterium mixes by thermal diffusion throughout the entire thickness of the film. The number of neutrons obtained from a target is then proportional to the initial tritium content of the film. A novel thin-film target design was also developed and tested. With these thin-film targets, the incident deuterium is implanted through the tritide into the underlying substrate material. A thin permeation barrier layer between the tritide film and substrate, reduces the rate of tritium loss from the tritide film. Good thin-film target performance was achieved using W and Fe for the barrier and substrate materials respectively. Thin-film targets were fabricated and tested and shown to produce similar number of neutrons as thick-film targets while using only a small fraction of the amount of tritium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chemical Kinetics of the Autoxidation of Poly(ethylenimine) in CO 2 Sorbents

The oxidative degradation rates of a CO 2 sorbent composed of a mesoporous alumina impregnated with poly- (ethylenimine) (PEI) are measured under systematically varied conditions and a reaction rate law is created. Good agreement is shown between the rate of oxidation obtained via in situ calorimetric heat measurement during oxidative degradation reactions and the loss of CO 2 capture performance presented as amine efficiency (mol CO 2 /mol amine). PEI mass loss and elemental composition are tracked over the course of the reaction and used in conjunction with the oxidation rate measurements to shed insight into the oxidation reaction(s). These data, in combination with measurements of the heat of reaction, suggest a common reaction set across the range of temperatures, oxygen concentrations, and sorbent compositions tested. The data are consistent with the basic autoxidation scheme (BAS), the accepted mechanism of autoxidation of aliphatic polymers. We propose a lumped kinetic model to describe the oxidation reaction set and estimate an activation energy of 105 kJ/mol and an oxygen reaction order of 0.5–0.7 from the data accordingly. Furthermore, these parameters can be incorporated into process cycle models to estimate the material lifetime, a critical uncertainty in the deployment of DAC technologies.

36 MATERIALS SCIENCE↗