Characterization and Measurement of Spacecraft Airborne Particulate Matter

The International Space Station (ISS) gives a 6-member astronaut crew the ability to live and work in low Earth orbit. It is a unique indoor environment, which has served as both home and workplace to over 230 people since the year 2000. In this low gravity environment, smoke does not rise and cookie crumbs do not settle the way they do on Earth, causing airborne particulate matter, or aerosols, to behave differently and pose unique hazards for crew members. In its existence, virtually the same volume of ISS air has been continuously conditioned and ‘revitalized,’ including the removal of particles by filtration. While gaseous constituents of ISS air are monitored meticulously, sparse data exists on the indoor aerosols. The quantity and types of ISS airborne debris have been investigated in NASA’s Aerosol Sampling Experiment. Both active and passive samplers successfully collected airborne particulate matter in U.S. segments of the ISS, which were returned to Earth for characterization by microscopy and other techniques. The resulting data has informed the design of candidate particle instruments for spacecraft. In 2020, a reference-quality aerosol instrument will be flown to ISS, and will provide real-time data of particle concentrations in various modules. Smaller, more compact instruments will be necessary in future space missions, for example, in smaller vehicles, in habitats on lunar and planetary surfaces with ubiquitous dust, and also for use as wearable technology throughout missions. Miniaturized aerosol sensors, though lower fidelity than reference-quality instruments, can monitor the environment well when calibrated appropriately. Indoor air quality in spacecraft is fundamentally important to human health and comfort, and several particulate monitoring technologies will be at sufficient technology readiness levels for operational use within the next two years. Results of the Aerosol Sampling Experiment will be presented, along with the status of NASA’s aerosol instrument technology demonstrations on ISS.

Meyer, Marit E.↗

Solid particulate pump

A pump for transporting particulate material that includes a first conveyor and a second conveyor together defining a passage, wherein a working surface of each of the conveyors are canted with respect to each other. The pump includes an inlet for introducing the particulate material into the passage and an outlet for expelling the particulate material from the passage, wherein the outlet is positioned out of line with the inlet.

Saunders, Timothy W.↗

Experimental investigation of the effect of pore size distribution on nano-particle capture efficiency within ceramic particulate filters

The effect of the pore size distribution on size-resolved filtration efficiency was investigated for two ceramic particulate filters using particulate matter (PM) generated by a spark-ignition direct-injection engine fueled with gasoline. The cordierite filter tested had a porosity of 43%, a median pore diameter (d_50) of 12 µm, and a wide pore size distribution with a lognormal standard deviation (s’) of 0.3. The aluminum titanate filter had very similar porosity, d_50, and thickness, but significantly narrower pore size distribution (s’ = 0.1). The testing of two filters under identical experimental conditions enabled the impact of the pore size distribution on filtration performance to be evaluated. Filtration experiments were performed focusing on just the filter wall, starting from a clean filter until the transition to cake filtration (filtration efficiency > 99%). Time-resolved particle size distribution measurements were used to evaluate the progression of filtration performance and estimate trapped mass within the filter. The aluminum titanate filter, with a narrow pore size distribution, exhibited significantly better diffusion capture efficiency. The negative impact of higher flow velocity on diffusion capture efficiency was more pronounced for a narrower pore size distribution. Flow distributions measured using capillary-flow porometry were used to develop a cylindrical pore flow model to understand the impact of the differences in pore size distribution on observed trends in diffusion capture efficiency within a clean filter. The model helps demonstrate how large pores on the high end of a wider pore size distribution can carry a large fraction of the flow, with less efficient capture of small particles by diffusion. The experimental results and data demonstrate that the bubble point diameter and width of the pore size distribution significantly influence diffusion capture efficiencies for filters with very similar median pore diameter, porosity, and thickness.

aerosol filtration, Aftertreatment, ceramic exhaus↗

The value of adding black carbon to community monitoring of particulate matter

Low-cost particulate matter (PM) sensors are increasingly used by researchers, public health agencies, and the public to measure spatial and temporal variations in air pollution, which can inform strategies for community air pollution reduction. While low-cost PM sensors provide a valuable measure of harmful fine particulate matter (PM 2.5 ), a significant portion of ambient PM 2.5 is typically the secondary product of air pollution emitted by varied sources outside of community boundaries. In contrast, concentrations of black carbon (BC), a component of PM 2.5 , are directly emitted by a few specific sources, such as diesel engines within communities. Motivated by community organizations seeking to understand persistent sources of local pollution, this study deployed a suite of custom-built BC sensors alongside a network of low-cost PM sensors for four weeks in two seasons at 50 stationary locations in the adjacent cities of Richmond, North Richmond, and San Pablo, California, east of the San Francisco Bay. Concentrations of BC varied more than PM 2.5 both temporally and spatially. Monthly network-average BC was 3×higher in winter than late spring, while PM 2.5 was only 10% lower. In both seasons, average PM 2.5 concentrations at two-thirds of sites were within ±10% of the network average, whereas two-thirds of sites had BC levels outside of ±10% of the network-average concentration. The most and least polluted locations were more persistent across seasons for BC than PM 2.5 , and the temporal dynamics of BC at these sites were similar, signifying that they are impacted by the same emission sources. Together, these spatiotemporal trends show that BC is a better indicator of the proximity and activity of local pollution sources than PM 2.5 . Thus, including BC in addition to PM 2.5 in community monitoring networks can provide additional insights about local sources of air pollution.

54 ENVIRONMENTAL SCIENCES↗

Computational predictions of porosities, pore size distributions, and conductivities of aerosol deposited particulate films

The structure and resulting physical properties of aerosol deposited particulate films are governed by the size distribution and morphology of the depositing particles as well as the physics governing particle deposition. While particulate film deposition processes are qualitatively understood, the link between particle characteristics and deposition physics to film properties has not been probed systematically. Here we apply a combination of Langevin dynamics deposition simulations, Monte Carlo pore size distribution calculations, and predictions of thermal conductivities to better establish such process parameter-film property relationships. Furthermore, we account for partial coalescence, polydispersity, and aggregate deposition. We establish that the deposition of polydisperse and aggregated particles leads to broadening of the pore size distribution function and an increase in the mode pore size. Via a non-continuum gas conductivity model, we show that aerosol deposited films can achieve porosities and thermal conductivities similar to conventional aerogels.

36 MATERIALS SCIENCE↗

Dominance of Particulate Mercury in Stream Transport and Rapid Watershed Recovery from Wildfires in Northern California, USA

Frequency and intensity of wildfires are expected to increase due to climate change, especially in areas with a long summer drought. Forests are a major sink for the global pollutant mercury (Hg), and fluvial transport of Hg from recently burned watersheds has not been widely investigated. Here, we examined two years of fluvial transport of Hg and its speciation (total Hg, methyl-Hg, particulate, and dissolved forms) under storm events and baseflow in two recently burned watersheds with different burned proportions and one nonburned reference watershed in the Coastal Ranges of northern California. We examined postfire storm-event transport of Hg and its methylated form (methyl-Hg), addressed the importance of the “initial runoff pulse” to postfire Hg fluvial transport and its predominant association with suspended solids, and elucidated potential sources of Hg exports from the burned landscapes using geochemical indicators, which suggested that ash materials were likely the significant sources of particulates in the first high-flow season postfire but not subsequently. The maximum total suspended solid and total Hg levels in the “first pulse” at the severely burned watershed were 442 and 46 times higher, respectively, than those at the reference watershed. Stream suspended solid and Hg levels declined substantially in the burned watersheds after just a few months of rainfall likely due to the rapid regrowth of vegetation commonly observed in postfire landscapes, implying that the wildfire effects on immediate Hg inputs from the burned landscape are at most transient in nature.

54 ENVIRONMENTAL SCIENCES↗

Cooled Spray Technology for Particulate Reduction in a Heavy-Duty Engine

Cooled spray (CS) technology passively reduces particulate matter (PM) emissions from diesel engines compared to non-CS-equipped diesel engines. CS inserts are mounted near the injector nozzle and control mixing so that the fuel and air can premix while limiting combustion near fuel-rich zones, thereby reducing the formation of particulate matter. CS components contain no moving parts and could be installed as a retrofit or built into new engines. However, CS technology is early in its development, and further investigations are needed to understand the overall performance implications and practicality of the technology. In this paper, we investigate several important aspects of CS, providing a clearer picture of some challenges and potential benefits of CS. Two alignment techniques are used to characterize measurement ease and bias, namely, an optical alignment and spray-plug impact alignment. While the optical technique facilitates alignment more easily, a bias was measured between the optical and spray-plug techniques, suggesting the optical technique may have insufficient accuracy without additional corrections. We also evaluate the engine performance of a well-aligned and poorly aligned CS insert, compared to the baseline configuration. The poorly aligned insert shows slower combustion than the baseline and mixed overall performance. However, the well-aligned insert shows faster combustion than the baseline and PM emission reduction at most operating conditions, with some conditions showing PM reduction up to 80%. Furthermore, the results of this paper highlight the alignment challenges of CS technology as well as the potential PM reduction benefit of the technology.

33 ADVANCED PROPULSION SYSTEMS↗

Particulate filtration from emissions of a plasma pyrolysis assembly reactor using regenerable porous metal filters

Microwave-based plasma pyrolysis technology is being studied as a means of supporting oxygen recovery in future spacecraft life support systems. The process involves the conversion of methane produced from a Sabatier reactor to acetylene and hydrogen, with a small amount of solid carbon particulates generated as a side product. The particles must be filtered before the acetylene is removed and the hydrogen-rich gas stream is recycled back to the CRA. We discuss developmental work on porous metal media filters for removing the carbon particulate emissions from the PPA exit gas stream and to provide in situ media regeneration capability. Because of the high temperatures involved in oxidizing the deposited carbon during regeneration, there was particular focus in this development on the materials that could be used, the housing design, and heating methods. This paper describes the design and operation of the filter and characterizes their performance from integrated testing at the Environmental Chamber (E-Chamber) at MSFC.

particulates↗

Exploration Mission Particulate Matter Filtration Technology Performance Testing in a Simulated Spacecraft Cabin Ventilation System

Human deep space exploration missions will require advances in long-life, low maintenance airborne particulate matter filtration technology. As one of the National Aeronautics and Space Administrations (NASA) developments in this area, a prototype of a new regenerable, multi-stage particulate matter filtration technology was tested in an International Space Station (ISS) module simulation facility. As previously reported, the key features of the filter system include inertial and media filtration with regeneration and in-place media replacement techniques. The testing facility can simulate aspects of the cabin environment aboard the ISS and contains flight-like cabin ventilation system components. The filtration technology test article was installed at the inlet of the central ventilation system duct and instrumented to provide performance data under nominal flow conditions. In-place regeneration operations were also evaluated. The real-time data included pressure drop across the filter stages, process air flow rate, ambient pressure, humidity and temperature. In addition, two video cameras positioned at the filtration technology test articles inlet and outlet were used to capture the mechanical performance of the filter media indexing operation under varying air flow rates. Recent test results are presented and future design recommendations are discussed.

particulate matter filtration↗

Feasibility of using Low-Cost COTS Sensors for Particulate Monitoring in Space Missions

Real-time measurement of particles suspended in the spacecraft cabin is of great importance to verify that maximum allowable dust concentrations are not exceeded. This is primarily to protect astronaut health, but also has implications for dust-sensitive equipment. Recently, there is growing interest in low-cost commercial off-the-shelf (COTS) particle sensors by air quality researchers for their ability to map concentrations of airborne particulate matter in various terrestrial settings. In addition to low cost (< $2,000), the compact size and minimal weight of these sensors make them a potential choice for space missions. The detection mechanism for these aerosol sensors is typically measurement of light scattered by particles as they flow through a sensing volume. The amount of scattered light for detection depends on the particle size, shape, density, and refractive index of the particle material. Ideally, particle instruments should be calibrated with reference instruments for each different type of aerosol measurement. In this study we review multiple parameters that may impact the performance of state-of-the-art low-cost aerosol sensors. Environmental factors such as temperature, relative humidity, low ambient pressure, radiation and charge environment, partial-gravity and microgravity can affect the accuracy of particle measurements. Characteristics of the dust aerosols including particle size distribution, aerosol composition, refractive index, morphology and concentration levels also affect the measurement accuracy. Finally, we look at these parameters and issues with respect to an example COTS low-cost aerosol sensor. Instrument performance specifications are evaluated, and experiments are performed to measure real-time concentrations of Arizona Road Dust (a terrestrial reference test dust) and lunar dust simulant in a laboratory chamber. Overall, this study provides insight for evaluating spacecraft particulate monitoring technologies and raises questions to be answered before incorporating low-cost COTS sensors in future space missions to dusty destinations.

lunar dust↗

Premature Deaths in Africa Due to Particulate Matter Under High and Low Warming Scenarios

Sustainable development and climate change mitigation can provide enormous public health benefits via improved air quality, especially in polluted areas. We use the latest state-of-the-art composition-climate model simulations to contrast human exposure to fine particulate matter in Africa under a “baseline” scenario with high material consumption, population growth, and warming to that projected under a sustainability scenario with lower consumption, population growth, and warming. Evaluating the mortality impacts of these exposures, we find that under the low warming scenario annual premature deaths due to PM2.5 are reduced by roughly 515,000 by 2050 relative to the high warming scenario (100,000, 175,000, 55,000, 140,000, and 45,000 in Northern, West, Central, East, and Southern Africa, respectively). This reduction rises to ∼800,000 by the 2090s, though by that time much of the difference is attributable to the projected differences in population. By contrast, during the first half of the century benefits are driven predominantly by emissions changes. Depending on the region, we find large intermodel spreads of ∼25%–50% in projected future exposures owing to different physics across the ensemble of 6 global models. The spread of projected deaths attributable to exposure to fine particulate matter, including uncertainty in the exposure-response function, are reduced in every region to ∼20%–35% by the non-linear exposure-response function. Differences between the scenarios have an even narrower spread of ∼5%–25% and are highly statistically significant in all regions for all models. These results provide valuable information for policy-makers to consider when working toward climate change mitigation and sustainable development goals.

PM2.5↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗

Particulate Emission and Optical Measurements in n-Heptane Low-Swirl Non-Premixed Flames at Elevated Pressures

A series of ground combustion tests conducted at elevated pressures demonstrates in-chamber optical measurements of soot emissions, combined with conventional gaseous and particle emissions sampling techniques. Utilizing a micro-radial-entry counter-swirl (MRX) burner, we successfully stabilized an n-heptane low-swirl, non-premixed spray flame across a wide range of equivalence ratios at pressures reaching 250 psia. Our optical diagnostics feature a temporally gated diffused-backlight illumination extinction imaging (DBI-EI) system, equipped with a 470-nm strobe high-intensity LED array as the illumination source, along with a line-of-sight telecentric camera. By accessing the flame tube, the pulsed DBI-EI provides illuminating optical extinction images, enabling experimental estimation of soot volume fractions within the reaction zone. This imaging technique will allow for real-time observation of soot formation dynamics occurring above the air-blast fuel injector. To further enhance our analysis, we employed simultaneous gaseous and particulate extractive diagnostics, interpreting in-flame particulate information through CO2 sampling, exhaust particle sizing, and particle counting. The processed dataset reveals a promising application of DBI-EI for propulsion emission analysis in high-pressure environments, where optical beam-steering effects can significantly impact results. This report is essential to bridging the divide between in-flame optical diagnostics and exhaust extractive measurements. By achieving an understanding of non-premixed combustion emission characteristics, we attempt to provide invaluable data for computer code validation, advancing the field of combustion research and supporting the development of cleaner, more efficient engines.

high-pressure flame↗

Application of Atmospheric Gases and Particulate Matter to the Assessment of Urban Heat Island

Background: Urban heat island (UHI), where built areas are warmer compared to non-urban regions, increases human related diseases and mortality. A key challenge in UHI analysis is the designation of sites as urban or suburban/rural; however, the growing complexity of green spaces in urban areas and the predominance of the transportation sector in nonurban areas creates a dilemma for distinct delineation. Objectives: This study aims to utilize the variability of atmospheric components such as particulate matter (PM), inorganic gases, and volatile organic compounds (VOCs) as direct tracers of the degree of urbanization for ground-based measurements to fully comprehend UHI in convoluted regions with indistinct delineation of urban and nonurban environments. Methods: Atmospheric gases and aerosols were used as direct tracers of urbanization for UHI analysis. Inorganic gases and particulate matter were monitored in two sites in a southeastern US city with varying degrees of urbanization. VOCs were analyzed using a proton transfer reaction time-of-flight mass spectrometer. Results: The more-urbanized site exhibited warmer night conditions and elevated total oxidant levels, leading to the formation of nanometer-sized particles. Machine learning analysis revealed similar atmospheric pollutant profiles for both sites, suggesting comparable sources and variability. Biogenic VOCs were enhanced at the less-urbanized site; however, levels of anthropogenic aromatic VOCs were comparable for both sites. A comprehensive mass spectra analysis revealed distinct molecular backbones per site that further affirmed the applicability of VOCs as indicators of urbanization. Conclusion: This study concludes that VOCs provide more direct and accurate information than typical inorganic gases and PM parameters for characterizing the degree of urbanization. Further exploration of VOCs can enhance our understanding of UHI dynamics and its interaction with vegetation in urban green spaces.

Air quality sensor↗

Impact of grassland fire dynamics on particulate emission factors

Understanding particulate emission factors in grassland fires is critical for improving air quality assessments and refining emissions inventories. This study explores the dynamic and heterogeneous nature of fire processes and their influence on particulate emissions. Traditional emission factor inventories often rely on static values, overlooking the spatially and temporally variable dynamics of fire behavior. Through field experiments conducted at Konza Prairie Biological Station measuring emissions with uncrewed aerial vehicles, and computational modeling using HIGRAD/FIRETEC, this research highlights the dependency of emission production on localized fire dynamics, including ignition patterns, fuel properties, and atmospheric conditions. The results demonstrate a need for fire dynamic considerations to accurately capture emissions variability.

09 BIOMASS FUELS↗

Mesoscale shock structure in particulate composites

Multiscale experiments in heterogeneous materials and the knowledge of their physics under shock compression are limited. Here, this study examines the multiscale shock response of particulate composites comprised of soda-lime glass particles in a PMMA matrix using full-field high speed digital image correlation (DIC) for the first time. Normal plate impact experiments, and complementary numerical simulations, are conducted at stresses ranging from 1.1 - 3.1 GPa to elucidate the mesoscale mechanisms responsible for the distinct shock structure observed in particulate composites. The particle velocity from the macroscopic measurement at continuum scale shows a relatively smooth velocity profile, with shock thickness decreasing with an increase in shock stress, and the composite exhibits strain rate scaling as the second power of the shock stress. In contrast, the mesoscopic response was highly heterogeneous, which led to a rough shock front and the formation of a train of weak shocks traveling at different velocities. Additionally, the normal shock was seen to diffuse the momentum in the transverse direction, affecting the shock rise and the rounding-off observed at the continuum scale measurements. The numerical simulations indicate that the reflections at the interfaces, wave scattering, and interference of these reflected waves are the primary mechanisms for the observed rough shock fronts.

36 MATERIALS SCIENCE↗

Development and evaluation of an agar capture system (ACS) for high-throughput screening of insoluble particulate substrates with bacterial growth and enzyme activity assays

In this work, we describe a method for containing insoluble particulates for use as substrates in either bacterial growth or enzyme assays. This method was designed for high-throughput screening of environmental or engineered bacteria. Benchmarking this method with several model bacteria uncovered phenotypes not observable with the particulate substrates alone.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of 3D printing filaments containing metal additives and their particulate emissions

Polylactic acid (PLA) filaments are widely used in fused filament fabrication (FFF) processes (3D printing). Filament additives such as metallic particles incorporated into PLA to modify functional and aesthetic features of print objects are becoming increasingly popular. However, the identities and concentrations of low percentage and trace metals in these filaments have not been well described in either the literature or product safety information included with the product. Here, we report the structures and concentrations of metals in selected Copperfill, Bronzefill and Steelfill filaments. We also report size-weighted number concentrations and size-weighted mass concentrations of particulate emissions as a function of print temperature for each filament. Particulate emissions were heterogenous in shape and size with airborne particles below 50 nm diameter dominating the size-weighted particle concentrations and larger particles (approximately 300 nm) dominating the mass weighted particle concentration. Results indicate that potential exposure to particles in the nano-size range increase when using print temperatures above 200o C. Because inhalation exposure to nanoparticles has been linked to adverse health outcomes, we suggest that using lower print temperatures for specific metal-fill filaments may reduce their operational hazard.

36 MATERIALS SCIENCE↗