Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A non-intrusive optical (NIO) approach to characterize heliostats in utility-scale power tower plants: Methodology and in-situ validation

No reliable in-situ optical characterization tool is available that can efficiently and accurately measure various optical errors of individual heliostats in a utility-scale power-tower plant. Here, an innovative non-intrusive optical (NIO) approach is proposed to measure mirror surface slope error, mirror facet canting error, and heliostat tracking error based on reflection images using the natural target—the tower—in a heliostat field. The NIO approach adopts various techniques in photogrammetry, reflectometry, and geometrical optics to first determine the camera position and the actual tower position with respect to the heliostat. Then, Snell’s law is applied to find the surface normal at the reflection point or line of a reflection image and derive the surface slope error, mirror facet canting error, and heliostat tracking error accordingly. In addition, an in-situ validation is performed to demonstrate the feasibility of the NIO approach. Analysis with multiple sets of reflection images on one single heliostat of interest demonstrates that the NIO method can achieve a measurement uncertainty of 0.22 mrad for mirror facet slope error (root-mean-square) at the given test conditions. The sensitivity of measurement uncertainty to various parameters will be presented in a separate work. In the future, state-of-the-art unmanned aerial systems (UAS) are planned to perform the efficient image collection with a goal to complete the survey across a utility-scale field of over 10,000 heliostats within one or a few days depending on the number of UASs. The development of the NIO approach is expected to fill the critical gap for successful solar-field operation and maintenance, which is necessary for the global growth of the solar power-tower technology. The NIO approach can also be applied to any relevant industry requiring high-precision mirror surface shape characterization.

14 SOLAR ENERGY↗

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Assessment of Homogeneous Mixture Method Cavitation Models in Predicting Cavitation in Nozzle Flow

The homogeneous mixture method (HMM) is a popular class of models used in the computational prediction of cavitation. Several cavitation models have been developed for use with HMM to govern the development and destruction of vapor in a fluid system. Two models credited to Kunz and Schnerr–Sauer are studied in this paper. The goal of this work is to provide an assessment of the two cavitation submodels in their ability to predict cavitation in nozzle flow. Validation data were obtained via experiments which employ both passive cavitation detection, (PCD) via acoustic sensing and optical cavitation detection (OCD) via camera imaging. The experiments provide quantitative information on cavitation inception and qualitative information on the vapor in the nozzle. The results show that initial vapor formation is not predicted precisely but within reason. A sensitivity analysis of the models to input parameters shows that the Schnerr–Sauer method does not depend upon the estimation of nuclei size and number density. Small changes in the vapor formation rate but not the total vapor volume can be seen when weighting parameters are modified. In contrast, changes to the input parameters for the Kunz model greatly change the final total vapor volume prediction. The assessment also highlights the influence of vapor convection within the method. Finally, the analysis shows that if the fluid and nozzle walls do not support nuclei larger than 40 μm, the methods would still predict cavitation when indeed there would be none in practice.

Engineering↗

Time-stretch spectroscopy for fast infrared absorption spectra of acetylene and hydroxyl radicals during combustion

We have developed a diagnostic that uses time-domain spectroscopy to measure transient infrared absorption spectra in gases. Using a time-stretch Fourier transform approach, we can determine pressure, temperature, and gas concentrations with sub-microsecond time resolution for over two milliseconds. We demonstrate high-resolution (0.015 nm), time-resolved spectral measurements in an acetylene-oxygen gas mixture undergoing combustion. Within a 5 µs period during the reaction, the acetylene line intensities decrease substantially, and new spectra appear that are consistent with the hydroxyl (OH) radical, a common by-product in the combustion, deflagration, and detonation of fuels and explosives. Post-reaction pressures and temperatures were estimated from the OH spectra. The technique measures spectra from 1520 to 1620 nm using fiber optics, photodetectors, and digitizers. No cameras or spectrometers are required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Imaging on Z LDRD: Design and Development of Self-Emission and Debris Imagers

We present an overview of the design and development of optical self-emission and debris imaging diagnostics for the Z Machine at Sandia National Laboratories. These diagnostics were designed and implemented to address several gaps in our understanding of visibly emitting phenomenon on Z and the post-shot debris environment. Optical emission arises from plasmas that form on the transmission line that delivers energy to Z loads and on the Z targets themselves; however, the dynamics of these plasmas are difficult to assess without imaging data. Addressing this, we developed a new optical imager called SEGOI (Self-Emission Gated Optical Imager) that leverages the eight gated optical imagers and two streak cameras of the Z Line VISAR system. SEGOI is a low cost, side-on imager with a 1 cm field of view and 30-50 µm spatial resolution, sensitive to green light (540-600 nm). This report outlines the design considerations and development of this diagnostic and presents an overview of the first diagnostic data acquired from four experimental campaigns. SEGOI was fielded on power flow experiments to image plasmas forming on and between transmission lines, on an inertial confinement fusion experiment called the Dynamic Screw Pinch to image low density plasmas forming on return current posts, on an experiment designed to measure the magneto Rayleigh-Taylor instability to image the instability bubble trajectory and self-emission structures, and finally on a Magnetized Liner Inertial Fusion (MagLIF) experiment to image the emission from the target. The second diagnostic developed, called DINGOZ (Debris ImagiNG on Z), was designed to improve our understanding of the post-shot debris environment. DINGOZ is an airtight enclosure that houses electronics and batteries to operate a high-speed (10-400 kfps) camera in the Z Machine center section. We report on the design considerations of this new diagnostic and present the first high-speed imaging data of the post-shot debris environment on Z.

42 ENGINEERING↗

On the Viability of Video Imaging in Leak Rate Quantification: A Theoretical Error Analysis

Optical gas imaging through multispectral cameras is a promising technique for mitigation of methane emissions through localization and quantification of emissions sources. While more advanced cameras developed in recent years have led to lower uncertainties in measuring gas concentrations, a systematic analysis of the uncertainties associated with leak rate estimation have been overlooked. We present a systematic categorization of the involved uncertainties with a focus on a theoretical analysis of projection uncertainties that are inherent to this technique. The projection uncertainties are then quantified using Large Eddy Simulation experiments of a point source release into the atmosphere. Our results show that while projection uncertainties are typically about 5% of the emission rate, low acquisition times and observation of the gas plume at small distances from the emission source (<10 m) can amount to errors of about 20%. Further, we found that acquisition times on the order of tens of seconds are sufficient to significantly reduce (>50%) the projection uncertainties. These findings suggest robust procedures on how to reduce projection uncertainties, however, a balance between other sources of uncertainty due to operational conditions and the employed instrumentation are required to outline more practical guidelines.

47 OTHER INSTRUMENTATION↗

Experimental observations of shock-wave-induced bubble collapse and hot-spot formation in nitromethane liquid explosive

We studied the collapse of individual helium gas bubbles in the homogeneous explosive nitromethane (NM) to investigate effects of hot-spot formation on the detonation process. A bubble was injected into a NM sample, and a shock wave from an explosive detonator compressed the bubble, creating a localized hot spot. We measured shock and detonation wave speeds with optical velocimetry, and we used a high-speed camera to image the shock propagation and the pre- and post-bubble collapse processes. An infrared camera image showed the residual radiance temperature distribution after the bubble collapse, and an optical fiber pyrometer measured the time-resolved thermal radiance. We measured the optical spectra of light emitted from detonating NM without a bubble and from a collapsing bubble in shocked, undetonated NM. We estimated temperatures of the detonation fronts and of the hot spots formed by bubble collapse. To study the incipient detonation process, we performed all bubble collapse experiments at pressures below the threshold for creating a sustained detonation. Where the bubble collapsed, we observed an opaque, thermally emissive region believed to be chemical reaction products. Chemical reactions in NM can be produced with lower shock pressures (~1 GPa) when a helium bubble is present than without a bubble (~10 GPa). We used hydrodynamic modeling to predict shock wave propagation, extent of chemical reaction, and subsequent temperature rise from the collapsing bubble. Simulations using a temperature-dependent Arrhenius burn model gave much better results than reactive burn models that depend only on pressure and density.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING↗

A Joint Search for the Electromagnetic Counterpart to the Gravitational-Wave Binary Black-Hole Merger Candidate S250328ae with the Dark Energy Camera and the Prime Focus Spectrograph

The first detection of an optical counterpart to a gravitational wave signal revealed that collaborative efforts between instruments with different specializations provide a unique opportunity to acquire impactful multi-messenger data. We present results of such a joint search with the Dark Energy Camera (DECam) and Prime Focus Spectrograph (PFS) for the optical counterpart of the LIGO-Virgo-KAGRA event S250328ae, a binary black hole merger candidate of high significance detected at a distance of 511$\pm$82 Mpc and localized within an area of 3 (15) square degrees at 50% (90%) confidence. We observed the 90% confidence area with DECam and identified 36 high-confidence transient candidates after image processing, candidate selection, and candidate vetting. We observed with PFS to obtain optical spectra of DECam candidates, Swift-XRT candidates, and potential host galaxies of S250328ae. In total, 3897 targets were observed by seven pointings covering ~50% of the 90% confidence area. After template fitting and visual inspection, we identified 12 SNe, 159 QSOs, 2975 galaxies, and 131 stars. With the joint observations of DECam and PFS, we found variability in 12 SNe, 139 QSOs, 37 galaxies, and 2 stars. We do not identify any confident optical counterparts, though the association is not ruled out for three variable candidates that are not observed by PFS and 6 QSO candidates without clear variability if the optical counterpart of S250328ae is faint. Despite the lack of confident optical counterparts, this paper serves as a framework for future collaborations between wide-field imagers and multi-object spectrographs to maximize multi-messenger analyses.

Zhang, Haibin [Natl. Astron. Observ. of Japan] (OR↗

Solving the auroral-arc-generator question by using an electron beam to unambiguously connect critical magnetospheric measurements to auroral images

Here, an active mapping mission is described that unambiguously connects measurements in the Earth's magnetosphere to visible aurora in the atmosphere. The core of the mission is an electron-beam source operated on a spacecraft in the equatorial magnetosphere, with the electron beam traveling along the Earth's magnetic-field lines to the atmosphere, depositing its energy to create an optical beam-spot in the atmosphere at the footpoint of the spacecraft's magnetic-field line. This optical spot can be imaged by ground-based cameras, putting the location of the spacecraft's magnetic footpoint into the context of the optical aurora. Scientific instruments carried on the spacecraft make critical measurements of the properties of the magnetosphere at the locations where the magnetosphere powers the aurora, allowing the determination of the plasma-physics mechanisms by which the magnetosphere drives the aurora, in particular answering the outstanding question of how the magnetosphere drives low-latitude auroral arcs. Long-standing questions in magnetosphere-ionosphere coupling that have not been answered because we could not unambiguously connect locations in the magnetosphere with their image in the ionosphere will finally be addressed. In this paper the properties of a “standard” growth-phase auroral arc are collected, theories of the magnetospheric generation of auroral arcs are reviewed, and critical magnetospheric measurements to discern the mechanisms that drive auroral arcs are determined. Further, the plasma physics of the experiment is investigated, including spacecraft-charging mitigation, beam stability, beam scattering, and electron orbit theory. Tradeoffs (keV versus MeV) concerning the energy of the electron beam are enumerated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of camera-based freehand SPECT in preoperative sentinel lymph node mapping for melanoma patients

Assessment of lymphatic status via sentinel lymph node (SLN) biopsy is an integral and crucial part of melanoma surgical oncology. The most common technique for sentinel node mapping is preoperative planar scintigraphy of an injected gamma-emitting lymphatic tracer followed by intraoperative node localization using a non-imaging gamma probe with auditory feedback. In recent years, intraoperative visualization of SLNs in 3D has become possible by coupling the probe to an external system capable of tracking its location and orientation as it is read out, thereby enabling computation of the 3D distribution of the tracer (freehand SPECT). In this project, the non-imaging probe of the fhSPECT system was replaced by a unique handheld gamma camera containing an array of sodium iodide crystals optically coupled to an array of silicon photomultipliers (SiPMs). A feasibility study was performed in which preoperative SLN mapping was performed using camera fhSPECT and the number of detected nodes was compared to that visualized by lymphoscintigraphy, probe fhSPECT, and to the number ultimately excised under non-imaging probe guidance. Among five subjects, SLNs were detected in nine lymphatic basins, with one to five SLNs detected per basin. A basin-by-basin comparison showed that the number of SLNs detected using camera fhSPECT exceeded that using lymphoscintigraphy and probe fhSPECT in seven of nine basins and five of five basins, respectively. (Probe fhSPECT scans were not performed for four basins.) It exceeded the number excised under non-imaging probe guidance for seven of nine basins and equaled the number excised for the other two basins. Freehand SPECT using a prototype SiPM-based gamma camera demonstrates high sensitivity for detection of SLNs in a preoperative setting. Camera fhSPECT is a potential means for efficiently obtaining real-time 3D activity distribution maps in applications such as image-guided percutaneous biopsy, and surgical SLN biopsy or radioguided tumor excision.

60 APPLIED LIFE SCIENCES↗

Evaluation of a fiber-coupled x-ray diffraction detector for dynamic compression experiments

The long-term x-ray diffraction (XRD) detector scheme compatible with Z-containment experiments will involve conversion of the diffracted x-rays to optical light, which will be transported away from the Z-Dynamic Materials Properties (DMP) load and detected on a fast-gated camera. In this so-called DIffraction SCintillator Optic (DISCO) scheme , the scintillator is coupled to a long, coherent imaging fiber bundle using a custom lens system with high numerical aperture. In addition, the DISCO diagnostic incorporates time-gating to allow measurement only during the short time window of the x-ray pulse in which XRD occurs, thereby significantly reducing unwanted background generated by the Z-DMP load. Dynamic compression experiments were performed at the Chama target chamber to evaluate the DISCO diagnostic . Specifically, a Zr sample was laser-shocked with the Chaco laser while the Z-Beamlet (ZBL) laser was used to generate x-rays, which enabled time-gated 6.7-keV XRD patterns from the compressed Zr sample to be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

The Dark Energy Camera Plane Survey 2 (DECaPS2): More Sky, Less Bias, and Better Uncertainties

Abstract Deep optical and near-infrared imaging of the entire Galactic plane is essential for understanding our Galaxy’s stars, gas, and dust. The second data release of the Dark Energy Camera (DECam) Plane Survey extends the five-band optical and near-infrared survey of the southern Galactic plane to cover 6.5% of the sky, ∣ b ∣ ≤ 10°, and 6° > ℓ > −124°, complementary to coverage by Pan-STARRS1. Typical single-exposure effective depths, including crowding effects and other complications, are 23.5, 22.6, 22.1, 21.6, and 20.8 mag in g , r , i , z , and Y bands, respectively, with around 1″ seeing. The survey comprises 3.32 billion objects built from 34 billion detections in 21,400 exposures, totaling 260 hr open shutter time on the DECam at Cerro Tololo. The data reduction pipeline features several improvements, including the addition of synthetic source injection tests to validate photometric solutions across the entire survey footprint. A convenient functional form for the detection bias in the faint limit was derived and leveraged to characterize the photometric pipeline performance. A new postprocessing technique was applied to every detection to debias and improve uncertainty estimates of the flux in the presence of structured backgrounds, specifically targeting nebulosity. The images and source catalogs are publicly available at http://decaps.skymaps.info/ .

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of average leaf inclination angle quantified by indirect optical instruments in crop fields

Average leaf inclination angle ($\overline{θ}$ L ) is an important canopy structure variable that influences light regime, photosynthesis, and evapotranspiration of plants. $\overline{θ}$ L can be measured through direct methods (e.g., protractor), which are labor-intensive and time-consuming, or through indirect optical instruments, which are more efficient than the direct methods. However, uncertainties of different indirect optical instruments for quantifying $\overline{θ}$ L remain largely unquantified. In this study, we evaluated and compared the performances of three major indirect optical instruments: (1) LAI-2200, (2) 30°-tilted camera, and (3) digital hemispherical photography (DHP), in different crop fields over a growing season, benchmarked with direct measurements. LAI-2200 and 30°-tilted camera showed higher agreement with direct $\overline{θ}$ measurements (R 2 = 0.54, RMSE = 7.37°; R 2 = 0.58, RMSE = 8.08°) than DHP (R 2 = 0.14, RMSE = 13.96°). Different performances of indirect optical instruments could be attributed to the accuracy of gap fraction measurement and the performance of the $\overline{θ}$ L quantification algorithms. When using the LAI-2200 algorithm, larger gap fraction gradients over view zenith angles led to larger $\overline{θ}$ L values, and smaller gap fraction gradients led to smaller $\overline{θ}$ L values. Such error propagation was larger in sparse canopy than in dense canopy. The Wilson G function of the LAI-2200 algorithm performed better in estimating $\overline{θ}$ L than the G function based on the ellipsoidal LAD function used by the CAN_EYE algorithm. We also proposed a modification of the LAI-2200 algorithm, which further improved the performance of LAI-2200 and 30°-tilted cameras in estimating $\overline{θ}$ L . We envision that the low-cost 30°-tilted cameras provide a promising sensor solution to continuously monitor canopy structure for various ecosystems.

30°-tilted camera↗

Searching for multimessenger transients and lensed supernovae with the dark energy survey

Advances in data collection technology for optical astronomy, such as the Dark Energy Camera, have facilitated the collection of some of the largest astronomical datasets in terms of sky area, depth, number of objects, number of observations, and frequency of observations. Consequentially, physical systems that have been historically rare become represented in small, but discoverable, numbers. I have developed techniques to identify rare physical systems (counterparts to high-energy neutrinos, counterparts to gravitational waves, and gravitationally lensed supernovae) that can shed new light on the physical processes that govern the Universe. For each system of interest, I collect new or search archival observations with the Dark Energy Camera, develop selection methodologies to find the system of interest in the observations, and quantify the efficiency of the search using simulations. Each of the three analyses has its own scientific implications: I constrain the observing program required to determine the contribution of supernovae to the diffuse high-energy neutrino flux; I set constraints on the physical properties of an optical counterpart to a compact object merger; and I identify candidate lensed supernovae using a novel machine learning technique. Looking forward, the work presented in this dissertation informs future rare object searches and facilitates measurements of the underlying properties of the Universe during the next era of optical survey astronomy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FiberFlex: Real-time FPGA-based Intelligent and Distributed Fiber Sensor System for Pedestrian Recognition

In recent years, security monitoring of public places and critical infrastructure has heavily relied on the widespread use of cameras, raising concerns about personal privacy violations. To balance the need for effective security monitoring with the protection of personal privacy, we explore the potential of optical fiber sensors for this application. This article proposes FiberFlex, an intelligent and distributed fiber sensor system. Ultizing Field Programmable Gate Arrays (FPGA) high-level synthesis (HLS) acceleration, FiberFlex offers real-time pedestrian detection by co-designing the entire pipeline of optical signal acquisition, processing, and recognition networks based on the principles of optical fiber sensing. As a promising alternative to traditional camera-based monitoring systems, FiberFlex achieves pedestrian detection by analyzing the vibration patterns caused by pedestrian footsteps, enabling security monitoring while preserving individual privacy. FiberFlex comprises three modules: First , fiber-optic sensing system: A fiber-optic distributed acoustic sensing (DAS) system is built and used to measure the ground vibration waves generated by people walking. Second , algorithms: We first collect the training data by measuring the ground vibration waves, label the data, and use the data to train the neural network models to perform pedestrian recognition. Third , hardware accelerators: We use HLS tools to design hardware modules on FPGA for data collection and pre-processing and integrate them with the downstream neural network accelerators to perform in-line real-time pedestrian detection. The final detection results are sent back from FPGA to the host CPU. We implement our system FiberFlex with the in-house built DAS system and AMD/Xilinx Kintex7 FPGA KC705 board and verify the whole system using the real-world collected data. We conduct recognition tests on five test subjects of varying ages, heights, and weights in a fixed sensing area. Each subject experienced 20 real-time recognition tests using their daily walking habits, and the subjects were given adequate rest between tests. After 100 tests on five test subjects, the overall real-time recognition accuracy exceeded \(88.0\%\) . The whole system uses 55 W of power, 33 W in the optical DAS system and 22 W in the FPGA. Relying on its end-to-end interdisciplinary design, FiberFlex seamlessly combines fiber-optic sensors with FPGA accelerators to enable low-power real-time security monitoring without compromising privacy, making it a valuable addition to the existing security monitoring network. According to FiberFlex, more valuable research can be conducted in the future, such as fall monitoring for the elderly, migration of identification networks between different application scenarios, and improvement of anti-interference performance in more complex environments. In future perception networks, where the “eyes” are not feasible, let’s use fiber optic touch instead.

Distributed↗

UEMtomaton: A Source-Available Platform to Aid in Start-up of Ultrafast Electron Microscopy Labs

The steady rise in the number of ultrafast electron microscopy (UEM) labs, in addition to the opacity and lack of detailed descriptions of current approaches that would enable point-by-point construction, has created an opportunity for sharing common methods and instrumentation for (for example) automating data acquisition to assist in efficient lab start-up and to learn about common and robust protocols. In the spirit of open sharing of methods, we provide here a description of an entry-level method and user interface (UI) for automating UEM experiments, and we provide access to the source code and scripts (source-available) for ease of implementation or as a starting reference point for those entering or seeking to enter the field (https://github.com/CEMSFlannigan/UEMtomaton/releases/tag/v1.0). Core instrumentation and physical connections in the UEM lab at Minnesota are described. Interface communication schemes consisting of duo server-client pairs between critical components – the optical delay stage and the UEM digital camera – are presented, with emphasis placed on describing the logic and communications sequence designed to conduct automated series acquisitions. An application designed and programmed with C++/CLI as Windows Forms in Microsoft Visual Studio – dubbed UEMtomaton – is also presented. Key to the UI layout is centralization of the automation tasks and establishment of communication within the software rather than by interfacing with each individual workstation. It is our hope that this note provides useful insight for current and future UEM researchers, particularly with respect to generalizability and portability of the approach to emerging labs. Here, we note that while this basic, entry-level approach is certainly not the most sophisticated or comprehensive of those currently in use, we feel there is nevertheless value in clearly communicating a proven straightforward method to hopefully lower the barrier to entry into the field.

47 OTHER INSTRUMENTATION↗