Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating system interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A cryogen-free ultralow-field superconducting quantum interference device magnetic resonance imaging system

Magnetic resonance imaging (MRI) at microtesla fields using superconducting quantum interference device (SQUID) detection has previously been demonstrated, and advantages have been noted. Although the ultralow-field SQUID MRI technique would not need the heavy superconducting magnet of conventional MRI systems, liquid helium required to cool the low-temperature detector still places a significant burden on its operation. We have built a prototype cryocooler-based SQUID MRI system that does not require a cryogen. The SQUID detector and the superconducting gradiometer were cooled down to 3.7 K and 4.3 K, respectively. We describe the prototype design, characterization, a phantom image, and areas of further improvements needed to bring the imaging performance to parity with conventional MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum physics of stars

Stars are slowly developing objects; the lifetimes of the different burning phases are determined by the strength of nuclear reactions, which in turn are defined by the quantum structure of the associated nuclei at the threshold and the respective reaction mechanisms. Stars, from the nuclear physics perspective, are cold environments where only a few of the key nuclear reactions have been measured at the actual stellar plasma temperatures. This is also the case for more dynamic astrophysical phenomena from the big bang to stellar explosions. Most of the nuclear reaction rates are therefore based on theoretical extrapolations. A number of discrepancies between these predictions and the associated stellar signatures have been observed, and many may be due to low-energy or near-threshold quantum effects. These effects need to be understood in order to reliably model nuclear reaction processes, not only for stars but also for low-temperature plasma environments such as controlled magnetic or inertial confinement fusion systems, which operate in similar temperature regimes. This review summarizes the various theoretical techniques presently used for deriving reaction rates and discusses possible quantum effects that may impact the reaction cross section near the reaction threshold. These resemble enhanced single-particle and cluster structures near threshold and associated interference effects. New experimental techniques such as deep-underground accelerators or the study of transfer reactions to mimic the quantum-mechanical transition strength, the so-called Trojan horse method, provide ways to directly or indirectly probe the reaction features that determine the reaction rates at stellar energies. Furthermore, this is demonstrated on a number of key nuclear reactions for different nucleosynthesis environments. Finally, current inconsistencies between experimental predictions and observations are discussed.

Models & methods for nuclear reactions↗

Interference Mitigation Effects on Synthetic Aperture Radar Coherent Data Products

For synthetic aperture radars radio frequency interference from sources external to the radar system and techniques to mitigate the interference can degrade the quality of the image products. Usually the radar system designer will try to balance the amount of mitigation for an acceptable amount of interference to optimize the image quality. This dissertation examines the effect of interference mitigation upon coherent data products of fine resolution, high frequency synthetic aperture radars using stretch processing. Novel interference mitigation techniques are introduced that operate on single or multiple apertures of data that increase average coherence compared to existing techniques. New metrics are applied to evaluate multiple mitigation techniques for image quality and average coherence. The underlying mechanism for interference mitigation techniques that affect coherence is revealed.

42 ENGINEERING↗

Passive Islanding Detection of Inverter-Based Resources in a Noisy Environment

Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup.

Energy & Fuels↗

Next Generation Weather Radar (NEXRAD) Radar Line-of-Sight

The Next Generation Weather Radar (NEXRAD) system is a network of doppler radar operated jointly by the National Weather Service (NWS), the Federal Aviation Administration (FAA), and the U.S. Air Force. This dataset represents a line-of-sight for each radar station. Radar line-of-sight can become saturated with wind energy due to interference. For further details and citation, please refer to the publication linked below: Lopez, Anthony, Pavlo Pinchuk, Michael Gleason, Wesley Cole, Trieu Mai, Travis Williams, Owen Roberts, Marie Rivers, Mike Bannister, Sophie-Min Thomson, Gabe Zuckerman, and Brian Sergi. 2024. Solar Photovoltaics and Land-Based Wind Technical Potential and Supply Curves for the Contiguous United States: 2023 Edition. Golden, CO: National Renewable Energy Laboratory. NREL/TP-6A20-87843.

Airspace/Defense↗

Performance of a Low Activity Beta-Sensitive SR{sup 90} Water Monitor for Fukushima

There are large volumes of contaminated water from the stabilization efforts at the damaged Fukushima Nuclear Power Plants. This water is being processed to remove radioactivity for eventual release to the environment. An on-line continuously operating system to confirm that the clean-up system is working properly, and to provide prompt feedback of the results is required by the system operator. While gamma emitting nuclides allow for the straight forward approach of gamma spectroscopy to identify and quantify radioactivity in water, pure beta emitting nuclides such as Sr{sup 90} pose a challenging problem. The relatively short range of beta radiation in water requires optimization of the measurement geometry in terms of the source-detector distance and source-detector interface while retaining a background sensitivity low enough to meet the Minimum Detectable Concentration (MDC) of 10 Bq/kg in 180 minutes. This issue is complicated by the continuum nature of the beta spectrum which does not allow for simple nuclide identification. The use of the Monte-Carlo code MCNP to estimate system performance before prototyping vastly increases the success of the end product. Various parameters such as detector size and thickness, water chamber size, water chamber construction materials were evaluated to help choose the optimum geometry. The final design was a system consisting of two large-area (16 x 35 cm) and thin (0.15 mm) plastic scintillators placed very close to a sealed a water chamber. The size of the chamber was optimized to obtain the maximum efficiency for the nuclide being measured (Sr/Y{sup 90}) but to minimize the efficiency for possible interferences (Ru/Rh{sup 106}, Cs{sup 137}). A thin carbon fiber window was selected with adequate material and thickness to contain the water under pressure, but also thin enough (0.5 mm) to allow enough beta radiation to pass through to the active detector volume. The entire measurement geometry is then housed in a thick lead shield to reduce contributions from external sources to an acceptable level. Data acquisition is accomplished through customized application-specific software that allows for long counting times to attain a low MDC, but also simultaneously provides alarms on short averaging times to achieve a fast response to sudden changes in activity concentration. Multiple monitors are then linked to supervisory software where real time data and alarms are available for analysis in remote locations. The system also allows for remote operation of the unit; check sources, background checks, systems settings and more may be accessed remotely. Testing of the production devices has shown that we can achieve the 10 Bk/kg MDC requirement for Sr{sup 90} in equilibrium with Y{sup 90} with a count time of approximately 20 minutes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superconductor Electronics: Status and Outlook

Superconductor electronics combines passive and active superconducting components and sometimes normal resistors into functional circuits and systems that also include room-temperature electronics for amplification, power sources, necessary controls, etc., usually computer operated. Furthermore, complete systems include magnetic and electromagnetic shielding, cryogenic enclosures, and increasingly a cryocooler in self-contained units. Components or devices of low or high critical temperature superconductors include inductances (coils), passive transmission lines, resonators, antennae, filters, as well as active elements: Josephson junctions, Josephson oscillators, and superconducting quantum interference devices. Of multiple demonstrated applications, mostly but not only in science and metrology, currently most successful are voltage standards, astronomy detectors and large telescope cameras, instruments for material characterization, and magnetometers for geomagnetic prospecting. Major current efforts concentrate on energy-efficient high-end computing and quantum computing. The outcomes of these efforts are likely to be known in the course of the following decade.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonlinear interference noise in 100-Gbit s{sup -1} communication lines with the DP-QPSK modulation format

The nonlinear interference noise power was measured experimentally as a function of the signal power and the length of the fibre coherent 100-Gbit s{sup -1} communication line, in which chromatic dispersion is not optically compensated. An expression was derived for the optimal signal power corresponding to a maximal excess of the measured optical signal-to-noise ratio (OSNR) over the OSNR required for conditionally error-free operation. The dependence of signal optimal power measured experimentally well agrees with the theoretical formula derived. (optical information transmission)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Report for Transmission of Information by Acoustic Communication along Metal Pathways in Nuclear Facilities

Transmission of information using elastic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall. A viable candidate for acoustic communication channel is a chemical volume control system (CVCS) stainless steel pipe, which penetrates through the containment building wall. A laboratory bench-scale system consisting of a nuclear grade CVCS-like pipe and ultrasonic transducers was assembled for a preliminary communication system analysis. Because of low bandwidth and spectral dispersion of ultrasonic transducers, on off keying (OOK) protocol was chosen for data communication. Operation of the acoustic communication during normal and post-accident conditions involves data transmission on the CVCS pipe, which according to literature guidelines, will be at 50°C and 150°C, respectively. Preliminary communication system development was performed using paintbrush PZT transducers capable of continuous operation at temperatures up to 80°C. Next, high-temperature LiNbO 3 acoustic transducers, originally developed for flow metering applications of EBRII reactor at Argonne, were utilized to develop a high-temperature acoustic communication system. A Gaussian pulse shape filter was introduced to suppress ringing and thus reduce inter-symbol interference. This resulted in enhancement of data transmission bitrate. Heating tapes, temperature controllers, and thermal insulation were installed on the laboratory pipe to study acoustic communication at elevated temperature. This included development of custom insertion heating elements for controlling temperature at pipe ends. Demonstrations of communication at high temperature included transmission of images and text files. Main achievements thus far include demonstration of transmission of 90KB image at the bitrate of 10Kbps with bit error rate smaller than 10 -3 across the pipe heated to 50°C and 150°C. Final phase of project development involved investigating strategies for deployment of the ultrasonic communication system in a representative environment. Mechanisms Engineering Test Loop (METL) facility at ANL was chosen as a viable candidate for communication system demonstration. Analysis of piping manifolds at METL has shown that in a typical scenario, ultrasonic signals have to be transmitted over straight and bent piping sections. This report describes preliminary studies on transmission of information with ultrasonic shear waves across bent piping sections. A test article consisting of a stainless steel pipe bent at 90° was developed for laboratory analysis of ultrasonic signal transmission. The bent piping test article developed by welding two straight pipes to an elbow. For consistency, the diameter and wall thickness of the bent pipe is the same as that of the straight pipe utilized in prior studies. COMSOL computer simulations were performed to study ultrasonic refracted shear wave coupling and transmission across bent piping. Preliminary evaluations of ultrasonic shear wave transmission were conducted with piezoelectric (PZT) and LiNbO 3 transducers, with the signals recorded with previously developed LabView interface. Preliminary results have shown significant dispersion of transmitted signals, most likely due to reflections and scattering by piping welds. Signal distortion compensation algorithm based on time reversal modulation (TRM) was initially investigated for transmission through solids, and demonstrated for signals transmitted over the bent pipe. Using TRM, it was shown that communication bitrates of 100Kbps were achievable, in principle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ascorbic Acid Stability and pH Testing to Support RWM-018 Pilot Scale Wellhead Treatment System Feasibility Determination

A multitude of groundwater remediation techniques for chlorinated volatile organic compounds (cVOCs) have been conducted at the A/M-Areas of the Savannah River Site (SRS). Historical in-situ chemical oxidation (ISCO) injections of potassium permanganate and sodium persulfate conducted in 2018 and 2020, have left residual oxidant concentrations in the A/M-Area groundwater system. ISCO events targeted dense non-aqueous phase liquids (DNAPLs) through the injection of strong oxidants within plume zones upgradient of current groundwater recovery wells RWM-008 and RWM-018. These residual oxidants could significantly impede the operation of the mercury removal system needed to meet National Pollutant Discharge Elimination System (NPDES) permit requirements for the ongoing pump-and-treat system that hydraulically controls potions of the A/M-Area plume. Effluent treated groundwater from this system is discharged to surface water at the receiving outfall of the M-1 Air Stripper. To prevent interference of the M-1 Air Stripper system by residual oxidants, groundwater recovery has been ceased at well RWM-018. Modeling of oxidant transport in A/M-Area from ISCO estimated that the potential oxidant load contributed by RWM-018 could be as high as 120 mg/L. It is also possible that oxidants may be contributed via pumping at well RWM-008 in the near future as residual oxidants within the aquifer migrate toward its zone of influence. Savannah River National Laboratory (SRNL) has conducted research to investigate potential pre-treatment chemicals to neutralize these residual oxidants, before reaching the M-1 Air Stripper, to allow for resumed groundwater recovery at RWM-018 and continued pumping at RWM-008. Deployment of ascorbic acid for neutralization of residual oxidants at RWM-018 (and possibly RWM-008) is recommended based on results from previous reductant testing (SRNL, 2021). For a maximum estimated oxidant load at RWM-0018, a well-head treatment system would need to dose about 400 gallons of ascorbic acid each month to ensure complete neutralization. A second system with additional reagent should also be considered for deployment at RWM-008.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EMI Mitigation of a Ćuk-Based Power-Electronic System Using Switching-Sequence-Based Control

Switching-sequence-based control (SBC) laws when designed based on topological switching behavior can have positive effects on slow- and fast-scale dynamics of a power-electronic system (PES). The slow-scale control can encompass fast PES state regulation and tracking, based on predefined objective, while fastscale control can address differential-mode (DM) and commonmode (CM) spectral-peak energy associated with PES switching operation. Such control laws may offer enhanced programmability to conventional PES design where bulky electromagnetic interference (EMI) filters have been traditionally used to reduce EMI of switching power converters to meet EMI regulatory standards. An EMI filter is always a less programmable solution since it is usually designed for the worst-case EMI mitigation and usually overkill for a PES operating under reduced load condition. The control scheme outlined in this article offers EMI mitigation across wide operating regions without compromising PES regulation. Moreover, it does so by use of switching sequences that guarantee the reachability of the PES dynamics using an advanced Lyapunov-function-based approach. SBC is a powerful tool to generate control actions for a PES based on multivariate PES state constraints. Hence, contemporary EMI regulatory standards are used as constraints in the SBC formulation to operate the PES under wide operating regime while autonomously mitigating the EMI levels. The work may be of paramount importance for operating the ultra-fast-transition recent wide-bandgap semiconductor devices like GaN–FET and SiC MOSFET under higher power with increasing switching frequencies, which is usually desirable for increased power density and reduced switching losses. Here, a hardware Cuk–PES operated ´ with GaN–FETs is fabricated and is used for case illustration. It is shown by experimental results how SBC mitigate DM and CM EMI noise of the PES while maintaining regulation even for the higher order nonminimum phase PES, while reducing sensor requirements using state observer derived from the switching model of the PES.

42 ENGINEERING↗

CHIRP-Like Signals: Estimation, Detection and Processing A Sequential Model-Based Approach

Chirp signals have evolved primarily from radar/sonar signal processing applications specifically attempting to estimate the location of a target in surveillance/tracking volume. The chirp, which is essentially a sinusoidal signal whose phase changes instantaneously at each time sample, has an interesting property in that its correlation approximates an impulse function. It is well-known that a matched-filter detector in radar/sonar estimates the target range by cross-correlating a replicant of the transmitted chirp with the measurement data reflected from the target back to the radar/sonar receiver yielding a maximum peak corresponding to the echo time and therefore enabling the desired range estimate. In this application, we perform the same operation as a radar or sonar system, that is, we transmit a “chirp-like pulse” into the target medium and attempt to first detect its presence and second estimate its location or range. Our problem is complicated by the presence of disturbance signals from surrounding broadcast stations as well as extraneous sources of interference in our frequency bands and of course the ever present random noise from instrumentation. First, we discuss the chirp signal itself and illustrate its inherent properties and then develop a model-based processing scheme enabling both the detection and estimation of the signal from noisy measurement data.

42 ENGINEERING↗

Systems and methods for interferometric end point detection for a focused ion beam fabrication tool

Various technologies for providing an operator of a focused ion beam (FIB) system with navigational and processing data are described herein. An exemplary system includes a broadband light source and a narrowband light source that emit light to a target of the FIB. An optical detector receives reflections of the broadband light from the target and outputs data that is used to generate two-dimensional images of the target in a region near a location of incidence of the FIB at the target. An interferometer receives reflections of the narrowband light from the target and outputs data indicative of an interference pattern of the narrowband reflections. A computing device computes a thickness of one or more material layers that make up the target based upon the interference pattern. A two-dimensional image of the target and an indication of the computed thickness are then displayed to the operator of the FIB.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model dynamics for quantum computing

A model master equation suitable for quantum computing dynamics is presented. In an ideal quantum computer (QC), a system of qubits evolves in time unitarily and, by virtue of their entanglement, interfere quantum mechanically to solve otherwise intractable problems. In the real situation, a QC is subject to decoherence and attenuation effects due to interaction with an environment and with possible short-term random disturbances and gate deficiencies. The stability of a QC under such attacks is a key issue for the development of realistic devices. We assume that the influence of the environment can be incorporated by a master equation that includes unitary evolution with gates, supplemented by a Lindblad term. Lindblad operators of various types are explored; namely, steady, pulsed, gate friction, and measurement operators. In the master equation, we use the Lindblad term to describe short time intrusions by random Lindblad pulses. The phenomenological master equation is then extended to include a nonlinear Beretta term that describes the evolution of a closed system with increasing entropy. An external Bath environment is stipulated by a fixed temperature in two different ways. Here we explore the case of a simple one-qubit system in preparation for generalization to multi-qubit, qutrit and hybrid qubit–qutrit systems. This model master equation can be used to test the stability of memory and the efficacy of quantum gates. The properties of such hybrid master equations are explored, with emphasis on the role of thermal equilibrium and entropy constraints. Several significant properties of time-dependent qubit evolution are revealed by this simple study. - Highlights: • General realistic density matrix evolution model shown for one qubit. • Unitary pulses & bias yield quantum gates without harmful phase accumulations. • Gate friction, dissipation included by random Lindblad noise pulses. • Bath & entropy terms yield equilibrium; test algorithms, gates act on Larmor grid. • Measurement modeled by strong, fast Lindblad pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling of Am-241 as an alternative fuel source in a radioisotope thermoelectric generator

Radioisotope thermoelectric generators (RTGs) have been utilized in the USA to power satellites and space exploration equipment for over half a century. In our preceding paper, Dustin and Borrelli (2021), we assessed the performance of 241 Am as an alternative to 238 Pu by modeling the specific decay-heat and gamma spectra of several potential radioisotopes in SCALE-ORIGEN, and comparing these with 238 Pu An analysis of heat output, heat stability, safety, availability and required mass showed that of the isotopes reviewed, 241 Am had the greatest potential for replacing 238 Pu, with additional design considerations. In our current work, we have assessed radiation transport for two configurations of an 241 Am powered Multi-Mission Radioisotope Thermoelectric Generator (MMRTG), due to the potential health effects for operators, fabricators, and others with the potential to be exposed to neutrons and lower energy gamma rays. We have modeled the use of americium as a fuel source replacement for plutonium in current MMRTG designs. The assessment has been performed using MCNP6, in terms of neutron and gamma emissions that might interfere with sensitive equipment and power system production. The radiation transport behavior in terms of dose rate of the 241 Am fueled models is compared with that of a 238 Pu fueled model. Finally, additional work was performed to validate modeling simplifications with regards to thermocouple material configurations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Strong parametric dispersive shifts in a statically decoupled two-qubit cavity QED system

Qubits in cavity quantum electrodynamic (QED) architectures are often operated in the dispersive regime, in which the operating frequency of the cavity depends on the energy state of the qubit, and vice versa. The ability to tune these dispersive shifts provides additional options for performing either quantum measurements or logical manipulations. Here we couple two transmon qubits to a lumped-element cavity through a shared superconducting quantum interference device (SQUID). In this work, our design balances the mutual capacitive and inductive circuit components so that both qubits are statically decoupled from the cavity with low flux sensitivity, offering protection from decoherence processes. Parametric driving of the SQUID flux enables independent, dynamical tuning of each qubit’s interaction with the cavity. As a practical demonstration, we perform pulsed parametric dispersive readout of both qubits. The dispersive frequency shifts of the cavity mode follow the theoretically expected magnitude and sign. This parametric approach creates an extensible, tunable cavity QED framework with various future applications, such as entanglement and error correction via multi-qubit parity readout, state and entanglement stabilization, and parametric logical gates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗