Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “occupancy detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Abundance and Migration Success of Overshoot Steelhead in the Upper Columbia River

Abstract Summer steelhead Oncorhynchus mykiss may enter freshwater almost a year before spawning and potentially make long migrations (>1,000 km) to interior headwater habitats. However, in response to suboptimal freshwater habitat conditions (e.g., warmer water temperatures), adult summer steelhead may exhibit complex behaviors during upstream migration in the Columbia River basin. Steelhead may migrate upstream of their natal tributary (hereafter, referred to as “overshoot”) and spend days to several months before subsequently migrating downstream (hereafter, referred to as “fallback”) to their natal tributary to spawn. An expansion of an existing Bayesian patch occupancy model, derived from observations of adult steelhead that were PIT-tagged to estimate population-specific abundance upstream of the tagging location, incorporated downstream detection locations to estimate the abundance of overshoot fallbacks. Overshoot steelhead abundance at the tagging location was estimated based on the relationship between the number of known overshoot fallbacks (i.e., the number of steelhead that overshot and successfully migrated downstream to their natal tributary) and their model-estimated abundance. During the study period (2010–2017), the annual mean proportion of overshoot steelhead that successfully migrated downstream of the tagging location (Priest Rapids Dam) was 0.59 (SD = 0.14). The number of dams encountered by overshoot steelhead during their downstream migration was negatively correlated with their downstream migration success probability. Improved downstream passage survival for adult steelhead will increase the abundance of affected populations while reducing potential genetic introgression of upstream populations (i.e., strays). This is the first study to estimate the abundance of overshoot and fallback steelhead, providing the data necessary for scientists to estimate potential conservation benefits of improved downstream survival. For example, surface flow passage routes (e.g., sluiceways and temporary spillway weirs) are very effective in guiding and passing adult steelhead downstream of Columbia River hydroelectric projects and data from this assessment show that changes in dam operations throughout the downstream migration period may maximize conservation benefits.

Murdoch, Andrew R. (ORCID:0000000324827689)↗

Impact of refrigerant undercharge faults on building indoor conditions and HVAC system operation in residential Buildings: A simulation study

This study investigates the impact of refrigerant undercharge on indoor temperature and HVAC system performance in residential buildings. Simulation models for typical residential buildings in Orlando, FL and Indianapolis, IN were developed using the ResStock database. A refrigerant undercharge fault model was then applied to the simulations with varying levels of fault intensity. The paper offers an extensive analysis, revealing that variations in supply air temperature, equipment runtime, and cooling energy consumption due to the level of refrigerant undercharge faults are notably significant on a summer representative day. Similarly, on a winter representative day, changes in supply air temperature and runtime are significant as well as changes in supplemental heat energy consumption. We find that occupants may remain oblivious to these faults during the cooling season, particularly when the HVAC system is oversized; in that case, supply air temperature data could help detect a fault. Another challenge is that during the heating season, when the supplemental heater operates, it is difficult to identify a refrigerant undercharge fault using only indoor and supply air temperature data. Finally, this study finds that supply air temperature, equipment runtime, and supplemental heater energy consumption data can help in detecting refrigerant undercharge faults.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

QuGrav: Bringing gravitational waves to light with qumodes

We propose using qumodes, quantum bosonic modes, for detecting high-frequency gravitational waves via the inverse Gertsenshtein effect, where a gravitational wave resonantly converts into a single photon in a magnetized cavity. For an occupation number n of the photon field in a qumode, the conversion probability is enhanced by a factor of n + 1 due to Bose-Einstein statistics. Unlocking this increased sensitivity entails the ability to continuously prepare the qumode and perform nondemolition measurement on the qumode-qubit system within the qumode coherence time. Our results indicate that, at microwave frequencies and with existing technology, the proposed setup can attain sensitivities within 1.7 orders of magnitude of the cosmological bound. With anticipated near-future improvements, it has the potential to surpass this limit and pave the way for the first exploration of high-frequency cosmological gravitational wave backgrounds. At optical frequencies, it can enhance the sensitivity of current detectors by one order of magnitude. That further enhances their potential in reaching the single-graviton level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A three-year dataset supporting research on building energy management and occupancy analytics

Abstract This paper presents the curation of a monitored dataset from an office building constructed in 2015 in Berkeley, California. The dataset includes whole-building and end-use energy consumption, HVAC system operating conditions, indoor and outdoor environmental parameters, as well as occupant counts. The data were collected during a period of three years from more than 300 sensors and meters on two office floors (each 2,325 m 2 ) of the building. A three-step data curation strategy is applied to transform the raw data into research-grade data: (1) cleaning the raw data to detect and adjust the outlier values and fill the data gaps; (2) creating the metadata model of the building systems and data points using the Brick schema; and (3) representing the metadata of the dataset using a semantic JSON schema. This dataset can be used in various applications—building energy benchmarking, load shape analysis, energy prediction, occupancy prediction and analytics, and HVAC controls—to improve the understanding and efficiency of building operations for reducing energy use, energy costs, and carbon emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bottleneck Detection in Modular Construction Factories Using Computer Vision

The construction industry is increasingly adopting off-site and modular construction methods due to the advantages offered in terms of safety, quality, and productivity for construction projects. Despite the advantages promised by this method of construction, modular construction factories still rely on manually-intensive work, which can lead to highly variable cycle times. As a result, these factories experience bottlenecks in production that can reduce productivity and cause delays to modular integrated construction projects. To remedy this effect, computer vision-based methods have been proposed to monitor the progress of work in modular construction factories. However, these methods fail to account for changes in the appearance of the modular units during production, they are difficult to adapt to other stations and factories, and they require a significant amount of annotation effort. Due to these drawbacks, this paper proposes a computer vision-based progress monitoring method that is easy to adapt to different stations and factories and relies only on two image annotations per station. In doing so, the Scale-invariant feature transform (SIFT) method is used to identify the presence of modular units at workstations, and the Mask R-CNN deep learning-based method is used to identify active workstations. This information was synthesized using a near real-time data-driven bottleneck identification method suited for assembly lines in modular construction factories. This framework was successfully validated using 420 h of surveillance videos of a production line in a modular construction factory in the U.S., providing 96% accuracy in identifying the occupancy of the workstations and an F-1 Score of 89% in identifying the state of each station on the production line. The extracted active and inactive durations were successfully used via a data-driven bottleneck detection method to detect bottleneck stations inside a modular construction factory. The implementation of this method in factories can lead to continuous and comprehensive monitoring of the production line and prevent delays by timely identification of bottlenecks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acute Exposure to Aerosolized Nanoplastics Modulates Redox-Linked Immune Responses in Human Airway Epithelium

Micro- and nanoplastics (MPs and NPs) are pervasive environmental pollutants detected in aquatic ecosystems, with emerging evidence suggesting their presence in airborne particles generated by water body motion. Inhalation exposure to airborne MPs and NPs remains understudied despite documented links between occupational exposure to these particles and adverse respiratory outcomes, including airway inflammation, oxidative stress, and chronic respiratory diseases. This study explored the effects of acute NP exposure on a fully differentiated 3D human airway epithelial model derived from 14 healthy donors. Airway epithelium was exposed to aerosolized 50 nm polystyrene NPs at concentrations ranging from 2.5 to 2500 µg/mL for three minutes per day over three days. Functional assays revealed no significant alterations in tissue integrity, cell survival, mucociliary clearance, or cilia beat frequency, suggesting intact epithelial function post-exposure. However, cytokine and chemokine profiling identified a significant five-fold increase in CCL3 (MIP-1α), a neutrophilic chemoattractant, in NP-exposed samples compared to controls. This was corroborated by increased neutrophil chemotaxis in response to conditioned media from NP-exposed tissues, indicating a pro-inflammatory neutrophilic response. Conversely, levels of interleukins (IL-21, IL-2, IL-15), CXCL10, and TGF-β were significantly reduced, suggesting immunomodulatory effects that may impair adaptive immune responses and tissue repair mechanisms. These findings demonstrate that short-term exposure to NP-containing aerosols induces a distinct pro-inflammatory response in airway epithelium, characterized by enhanced neutrophil recruitment and reduced secretion of key immune modulators. These findings underscore the potential for aerosolized NPs to induce oxidative and inflammatory stress, raising concerns about their long-term impact on respiratory health and redox regulation.

Biochemistry & Molecular Biology↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous bi-products of research activities or airborne pathogens. As a result, building ventilation is the primary defense against unseen airborne hazards. Critical laboratory facilities already demand the need for effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently available contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers on a limited budget. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in the critical laboratory environment. In this session, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories without breaking the bank. This paper describes a low-cost solution for providing a safe, healthy building environment and reducing energy use through effective, efficient ventilation.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Underlying simplicity of 5f unoccupied electronic structure

Using a simple empirical model based upon the bremsstrahlung isochromat spectroscopy of elemental Th, it is possible to explain the recent high energy resolution fluorescence detection measurements of UF 4 (n = 2) and UCd 11 (n = 3) as well as the new inverse photoelectron spectroscopy of Pu 2 O 3 (n = 5), where n is the 5f occupation number. Furthermore, a critical issue in this analysis is the assumption that the Th 5f states are essentially empty, which will be confirmed both experimentally and computationally. Thus, for 5f systems, this simple model provides a unified and consistent picture of 5f unoccupied density of states in simple, localized systems, as the 5f occupation varies in the early part of the series, for n = 0, 2, 3, and 5.

36 MATERIALS SCIENCE↗

Infrared-Fused Vision-Based Thermoregulation Performance Estimation for Personal Thermal Comfort-Driven HVAC System Controls

Thermal comfort is one of the primary factors influencing occupant health, well-being, and productivity in buildings. Existing thermal comfort systems require occupants to frequently communicate their comfort vote via a survey which is impractical as a long-term solution. Here, we present a novel thermal infrared-fused computer vision sensing method to capture thermoregulation performance in a non-intrusive and non-invasive manner. In this method, we align thermal and visible images, detect facial segments (i.e., nose, eyes, face boundary), and accordingly read the temperatures from the appropriate coordinates in the thermal image. We focus on the human face since it is often clearly visible to cameras and is not merged into a hot background (unlike hands). We use a regularized Gaussian Mixture model to track the thermoregulation changes over time and apply a heuristic algorithm to extract hot and cold indices. We present a personalized and a generalized comfort modeling method, selected based on the availability of the occupant historical indices measurements in a neutral environment, and use the time-series of the hot and cold indices to define corrections to HVAC system operations in the form of setpoint constraints. To evaluate the efficacy of our proposed approach in responding to thermal stimuli, we designed a series of controlled experiments to simulate exposure to cold and hot environments. While applying personalized modeling showed an acceptable average accuracy of 91.3%, the generalized model’s average accuracy was only 65.2%. This shows the importance of having access to physiological records in modeling and assessing comfort. We also found that individual differences should be considered in selecting the cooling and heating rates when some knowledge of the occupant’s overall thermal preference is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mortality of older construction and craft workers employed at Department of Energy (DOE) nuclear sites: Follow‐up through 2021

Background To determine if construction and trades workers formerly employed at US Department of Energy (DOE) nuclear weapons sites are at significant risk for occupational diseases, we studied the mortality experience of participants in the Building Trades National Medical Screening Program (BTMed). Methods The cohort included 26,922 participants enrolled between 1998 and 2021 and 8367 deaths. Standardized mortality ratios were calculated based on US death rates. Cox models compared construction workers (n = 22,747; 7487 deaths) to two nonconstruction subpopulations: administrative, scientific and security workers (n = 1894; 330 deaths), and all other nonconstruction workers (n = 2218; 550 deaths). Results Mortality was elevated for all causes, all cancers, cancers of the trachea, bronchus, lung, kidneys, and lymphatic and hematopoietic system, mesothelioma, chronic obstructive pulmonary disease (COPD), asbestosis, transportation injuries, and other injuries, particularly accidental poisonings. There were 167 deaths from coronavirus disease 2019 (COVID-19), which was lower than expected using US death rates. Overall cause-specific mortality was significantly higher among construction workers than for internal comparison groups. Conclusions Construction workers employed at DOE sites have a significantly increased risk for occupational illnesses. Apart from COVID-19 deaths, this update: (1) found that mortality among construction workers is significantly elevated compared to the US population and significantly higher than in the internal comparison populations, and (2) confirmed excess risk for these workers for first employment after 1990. Cancer mortality risks are similar to the cancers identified for DOE compensation from radiation exposures. In conclusion, the high lung cancer risk supports the value of early lung cancer detection. Continued medical surveillance is important.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous byproducts of laboratory research activities or airborne pathogens. As a result, building ventilation is a primary defense against unseen airborne hazards. Critical laboratory facilities require effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an in-depth intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently many contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in critical laboratory environments. In this article, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories. This article describes a low-cost sensor to support providing a safe, healthy building environment and reduce energy use through effective and efficient ventilation.

dynamic management of indoor air quality↗

Detection of Airborne Influenza A and SARS-CoV-2 Virus Shedding following Ocular Inoculation of Ferrets

Despite reports of confirmed human infection following ocular exposure with both influenza A virus (IAV) and SARS-CoV-2, the dynamics of virus spread throughout oculonasal tissues and the relative capacity of virus transmission following ocular inoculation remain poorly understood. Furthermore, the impact of exposure route on subsequent release of airborne viral particles into the air has not been examined previously. To assess this, ferrets were inoculated by the ocular route with A(H1N1)pdm09 and A(H7N9) IAVs and two SARS-CoV-2 (early pandemic Washington/1 and Delta variant) viruses. Virus replication was assessed in both respiratory and ocular specimens, and transmission was evaluated in direct contact or respiratory droplet settings. Viral RNA in aerosols shed by inoculated ferrets was quantified with a two-stage cyclone aerosol sampler (National Institute for Occupational Safety and Health [NIOSH]). All IAV and SARS-CoV-2 viruses mounted a productive and transmissible infection in ferrets following ocular inoculation, with peak viral titers and release of virus-laden aerosols from ferrets indistinguishable from those from ferrets inoculated by previously characterized intranasal inoculation methods. Viral RNA was detected in ferret conjunctival washes from all viruses examined, though infectious virus in this specimen was recovered only following IAV inoculation. Low-dose ocular-only aerosol exposure or inhalation aerosol exposure of ferrets to IAV similarly led to productive infection of ferrets and shedding of aerosolized virus. Viral evolution during infection was comparable between all inoculation routes examined. Furthermore, these data support that both IAV and SARS-CoV-2 can establish a high-titer mammalian infection following ocular exposure that is associated with rapid detection of virus-laden aerosols shed by inoculated animals.

60 APPLIED LIFE SCIENCES↗

Pressure cells for in situ neutron total scattering: time and real-space resolution during deuterium absorption

In situ gas-loading sample holders for two-dimensionally arranged detectors in time-of-flight neutron total scattering experiments have been developed to investigate atomic arrangements during deuterium absorption using time and real-space resolution. A single-crystal sapphire container was developed that allows conditions of 473 K and 10 MPa hydrogen gas pressure. High-resolution transient measurements detected deuterium absorption by palladium that proceeded within a few seconds. A double-layered container with thick- and thin-walled vanadium allowed conditions of 423 K and 10 MPa hydrogen gas pressure. The deuterium occupation sites of a lanthanum–nickel–aluminium alloy are discussed in detail on the basis of real-space high-resolution data obtained from in situ neutron scattering measurements and reverse Monte Carlo structural modeling.

08 HYDROGEN↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium thiostannate spinels: air-stable cubic semiconductors.

Lithium chalcogenide materials have been studied less than other alkali metal analogs and are of interest as ion conductors and semiconductors capable of thermal neutron detection. Herein, we describe the structural, thermal, magnetic, electronic, and ionic properties of a new family of cubic lithium thiospinels Li2MSn3S8 (M = Mg, Fe, Mn, Ni, Co) and Li1.66CuSn3.33S8. All compounds crystallize in the Fd (3) over barm space group and exhibit site occupancy disorder with Sn and M on the octahedral site for M = Mg, Fe, Mn, Ni, Co. The Li1.66CuSn3.33S8 compound also exhibits occupancy disorder on the tetrahedral sites between Li and Cu, as well as on the octahedral sites between Li and Sn. We demonstrate the ability to tune the physical properties of the compounds by changing their composition. By tuning the identity of the transition metal in the structure, the optical band gaps can vary between 0.91(2) and 2.19(2) eV, and electrical resistivities between 2.8 x 10(3) Omega-cm and 2.2 x 10(7)Omega-cm can be achieved. Density functional theory calculations for Li2MgSn3S8 and Li1.66CuSn3.33S8 suggest that both materials have indirect band gaps and significantly dispersive conduction bands. A bandwidth dispersion of 0.75 and 0.70 eV along the Gamma -> M direction in the conduction band are predicted for Li2MgSn3S8 and Li1.66CuSn3.33S8, respectively, with an electron effective mass of 0.49 and 0.55 m(e) at the Gamma point. The hole effective mass in the valence band is calculated to be 1.25 me at the M point and 0.75 me at the L point for Li2MgSn3S8 and Li1.66CuSn3.33S8, respectively. The ionic/electronic conductivity of each compound was determined using AC electrochemical impedance spectroscopy.

Quintero, Michael A.↗