Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “object reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION↗

Demonstration and analysis of volumetric additive manufacturing via sub-orbital spaceflight testing

Computed Axial Lithography (CAL) represents a significant advancement in the emerging field of Volumetric Additive Manufacturing (VAM). CAL addresses key limitations of traditional photopolymer additive manufacturing technologies, by eliminating the need for layering and support structures. Unlike conventional methods, CAL prints components by illuminating all points within a desired geometry simultaneously, using tomographic reconstruction to form the object in a single step. This unique approach eliminates the relative motion between the object and the precursor material, enabling faster printing speeds and reducing the waste associated with support structures. However, CAL parts require post-processing steps before they can be utilized. CAL's core attributes make it particularly suited for In-Space Manufacturing (ISM), due to its fast fabrication times, wide breadth of materials it can use, and minimized footprint. CAL has been successfully demonstrated in microgravity during parabolic flight experiments. However to fully validate and understand CAL's behaviour in microgravity, all manufacturing and post-processing steps must be integrated. In June 2024, we conducted SpaceCAL Mission 3, testing this entire workflow on a suborbital flight aboard Virgin Galactic's SpaceShipTwo. During ~140 s of microgravity, the system autonomously manufactured and post-processed four parts using PEGDA700 resin. Post-flight analysis showed that 2/4 parts were recognisable, while others were distorted due to bubble formation from residual water droplets, off-axis optical aberrations, and non-uniform solvent rinsing. Despite these limitations, this study represents the first integrated CAL workflow in space, providing an initial experimental demonstration and analysis for closed-loop in-space manufacturing.

Waddell, Taylor [Department of Mechanical Engineer↗

Conditional deep generative models for simultaneous simulation and reconstruction of entire events

We extend the particle-flow neural assisted simulations (arnassus) framework of fast simulation and reconstruction to entire collider events. In particular, we use two generative artificial intelligence tools, continuous normalizing flows and diffusion models, to create a set of reconstructed particle-flow objects conditioned on truth-level particles from CMS Open Simulations. While previous work focused on jets, our updated methods now can accommodate all particle-flow objects in an event along with particle-level attributes like particle type and production vertex coordinates. This approach is fully automated, entirely written in Python, and GPU-compatible. Using a variety of physics processes at the LHC, we show that the extended arnassus is able to generalize beyond the training dataset and outperforms the standard, public tool elphes.

Dreyer, Etienne [Weizmann Institute of Science, Re↗

Diagnostics for measuring 4D beam matrix [Slides]

Detailed knowledge on the particle distribution in accelerators can strongly benefit machine tuning and understanding of deleterious effects, which degrade beam quality. Properties of the beam downstream the beamline (i.e. 4D beam matrix) depend on beam properties upstream and parameters of the beamline. Measuring 2D x-y beam profile downstream provides limited information about the beam. Multiple measurements at different settings of the beamline (quadrupole scan) may provide enough information to recover original beam profile. Essentially, this concept is similar to tomography, when we need to reconstruct a higher dimension object from multiple low dimension projections.

43 PARTICLE ACCELERATORS↗

High speed optical tomography for flow visualization

A novel optical architecture (based on holographic optical elements) for making high speed tomographic measurements is presented. The system is designed for making density or species concentration measurements in a nonsteady fluid or combusting flow. Performance evaluations of the optical system are discussed, and a test phase object has been successfully reconstructed using this optical arrangement.

Snyder, R.↗

Systems and Methods for Imaging of Falling Objects

Imaging of falling objects is described. Multiple images of a falling object can be captured substantially simultaneously using multiple cameras located at multiple angles around the falling object. An epipolar geometry of the captured images can be determined. The images can be rectified to parallelize epipolar lines of the epipolar geometry. Correspondence points between the images can be identified. At least a portion of the falling object can be digitally reconstructed using the identified correspondence points to create a digital reconstruction.

Garrett, Tim↗

Microwave imaging of metal objects

The procedure of microwave imaging by maximum entropy method is discussed. First, the relationship between the induced current on the metal object surface and the scattered field is introduced. Our imaging concept is to reconstruct the induced current on the object surface from the measured scattered field. The object configuration will be provided by the induced current which is zero everywhere except on the object surface. Future work is also included with focus on the application of microwave imaging to both NASA and industry.

Krishen, Kumar↗

Advancing the Frontiers of Deep Learning for Low-Dose 3D Cone-Beam CT Reconstruction

X-ray computed tomography (CT) is an important noninvasive medical imaging modality for studying the structural details of internal organs. Image reconstruction in CT is an inverse problem of recovering an object's internal structure from the absorption profile of X-ray beams (sinogram) measured using a detector. The classical variational approach for CT reconstruction minimizes an energy functional using an appropriate iterative algorithm. Motivated by the success of deep learning (DL), researchers have begun to leverage training data and enhanced computing capabilities in recent years to produce high-fidelity reconstructed images. Nonetheless, much of the academic research in DL algorithms for CT has focused primarily on the two-dimensional setting (with simplified forward operators and noise model) for proofs-of-concept, and a comprehensive benchmarking of various classical and data-driven CT reconstruction approaches has not beenundertaken. The key objective of our CT reconstruction grand challenge was to promote methodological advancements for both classical and DL-based approaches for clinical CT with a reasonably accurately simulated 3D CT forward operator and noise model. We have utilized the publicly available LIDC-IDRI dataset and simulated sinograms and FDK images corresponding to two dose levels (clinical- and low-dose, constituting two tracks of the challenge) starting from the normal-dose images as the ground truth. In this paper, we summarize the motivation, context, and results of our challenge, and highlight the future research directions in DL for clinical CT.

X-ray tomography↗

Novel light field imaging device with enhanced light collection for cold atom clouds

We present a light field imaging system that captures multiple views of an object with a single shot. The system is designed to maximize the total light collection by accepting a larger solid angle of light than a conventional lens with equivalent depth of field. This is achieved by populating a plane of virtual objects using mirrors and fully utilizing the available field of view and depth of field. Simulation results demonstrate that this design is capable of single-shot tomography of objects of size $\mathcal{O}$(1 mm 3 ), reconstructing the 3-dimensional (3D) distribution and features not accessible from any single view angle in isolation. In particular, for atom clouds used in atom interferometry experiments, the system can reconstruct 3D fringe patterns with size $\mathcal{O}$(100 μm). We also demonstrate this system with a 3D-printed prototype. The prototype is used to take images of $\mathcal{O}$(1 mm 3 ) sized objects, and 3D reconstruction algorithms running on a single-shot image successfully reconstruct $\mathcal{O}$(100 μm) internal features. The prototype also shows that the system can be built with 3D printing technology and hence can be deployed quickly and cost-effectively in experiments with needs for enhanced light collection or 3D reconstruction. Imaging of cold atom clouds in atom interferometry is a key application of this new type of imaging device where enhanced light collection, high depth of field, and 3D tomographic reconstruction can provide new handles to characterize the atom clouds.

47 OTHER INSTRUMENTATION↗

Optimum coherent imaging of a limited field of view in the presence of angular and aperture noise

The question of image distribution reconstruction for coherent illumination of an object located in the aperture far zone is considered from first principles without postulating any particular optical spread function. The object function is mathematically modeled as a complex random function of angular coordinates, and it is assumed that the object distribution of interest is angularly limited to a certain a priori assigned field of view (FOV). A linear reconstruction procedure that is uniformly optimal in the FOV is established by using the methods of statistical estimation. Two special cases are examined: imaging a limited sector of a wide-angle random scene and objects in the FOV immersed in a wide-angle background of angular noise. It is noted that the domain of application of the reconstruction method is restricted to microwave frequencies.

Borgiotti, G. V.↗

Semi-analytic spectral fitting: simultaneously modelling the mass accumulation and chemical evolution in MaNGA spiral galaxies

We develop a novel semi-analytic spectral fitting approach to quantify the star formation histories (SFHs) and chemical enrichment histories (ChEHs) of individual galaxies. We construct simple yet general chemical evolution models that account for gas inflow and outflow processes as well as star formation, to investigate the evolution of merger-free star-forming systems. These models are fitted directly to galaxies’ absorption-line spectra, while their emission lines are used to constrain current gas phase metallicity and star formation rate. We apply this method to spiral galaxies selected from the SDSS-IV Mapping Nearby Galaxies at Apache Point Observatory survey. By fitting the co-added absorption-line spectra for each galaxy, and using the emission-line constraints on present-day metallicity and star formation, we reconstruct both the SFHs and the ChEHs for all objects in the sample. We can use these reconstructions to obtain archaeological measures of derived correlations such as the mass–metallicity relation at any redshift, which compare favourably with direct observations. We find that both the SFHs and ChEHs have strong mass dependence: massive galaxies accumulate their stellar masses and become enriched earlier. This mass dependence causes the observed flattening of the mass–metallicity relation at lower redshifts. The model also reproduces the observed gas-to-stellar mass ratio and its mass dependence. Moreover, we are able to determine that more massive galaxies have earlier gas infall times and shorter infall time-scales, and that the early chemical enrichment of low-mass galaxies is suppressed by strong outflows, while outflows are not very significant in massive galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Sparse Bayesian mass mapping with uncertainties: hypothesis testing of structure

ABSTRACT A crucial aspect of mass mapping, via weak lensing, is quantification of the uncertainty introduced during the reconstruction process. Properly accounting for these errors has been largely ignored to date. We present a new method to reconstruct maximum a posteriori (MAP) convergence maps by formulating an unconstrained Bayesian inference problem with Laplace-type l1-norm sparsity-promoting priors, which we solve via convex optimization. Approaching mass mapping in this manner allows us to exploit recent developments in probability concentration theory to infer theoretically conservative uncertainties for our MAP reconstructions, without relying on assumptions of Gaussianity. For the first time, these methods allow us to perform hypothesis testing of structure, from which it is possible to distinguish between physical objects and artefacts of the reconstruction. Here, we present this new formalism, and demonstrate the method on simulations, before applying the developed formalism to two observational data sets of the Abell 520 cluster. Initial reconstructions of the Abell 520 catalogues reported the detection of an anomalous ‘dark core’ – an overdense region with no optical counterpart – which was taken to be evidence for self-interacting dark matter. In our Bayesian framework, it is found that neither Abell 520 data set can conclusively determine the physicality of such dark cores at $99{{\ \rm per\ cent}}$ confidence. However, in both cases the recovered MAP estimators are consistent with both sets of data.

Price, M. A.↗

Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using a cylindrical-harmonics expansion

Inertial confinement fusion capsule implosions produce neutron, gamma-ray, and x-ray emission, which are recorded by a variety of detectors, both time integrated and time resolved, to determine the performance of the implosion. Further, two-dimensional emission images from multiple directions can now be combined to infer three-dimensional structures in the implosion, such as the distribution of thermonuclear fuel density, carbon ablator, and impurities. Because of the cost and complexity of the imaging systems, however, only a few measurements can be made, so reconstructions of the source must be made from a limited number of views. Here, a cylindrical-harmonics decomposition technique to reconstruct the three-dimensional object from two views in the same symmetry plane is presented. In the limit of zero order, this method recovers the Abel inversion method. The detailed algorithms used for this characterization and the resulting reconstructed neutron source from an experiment collected at the National Ignition Facility are presented.

47 OTHER INSTRUMENTATION↗

Distribution of Dust from Kuiper Belt Objects

Using an efficient computational approach, we have reconstructed the structure of the dust cloud in the Solar system between 0.5 and 100 AU produced by the Kuiper belt objects. Our simulations offer a 3-D physical model of the 'kuiperoidal' dust cloud based on the distribution of 280 dust particle trajectories produced by 100 known Kuiper belt objects; the resulting 3-D grid consists of 1.9 x 10' cells containing 1.2 x 10" particle positions. The following processes that influence the dust particle dynamics are taken into account: 1) gravitational scattering on the eight planets (neglecting Pluto); 2) planetary resonances; 3) radiation pressure; and 4) the Poynting-Robertson (P-R) and solar wind drags. We find the dust distribution highly non-uniform: there is a minimum in the kuiperoidal dust between Mars and Jupiter, after which both the column and number densities of kuiperoidal dust sharply increase with heliocentric distance between 5 and 10 AU, and then form a plateau between 10 and 50 AU. Between 25 and 45 AU, there is an appreciable concentration of kuiperoidal dust in the form of a broad belt of mostly resonant particles associated with Neptune. In fact, each giant planet possesses its own circumsolar dust belt consisting of both resonant and gravitationally scattered particles. As with the cometary belts simulated in our related papers, we reveal a rich and sophisticated resonant structure of the dust belts containing families of resonant peaks and gaps. An important result is that both the column and number dust density are more or less flat between 10 and 50 AU, which might explain the surprising data obtained by Pioneers 10 & 11 and Voyager that the dust number density remains approximately distance-independent in this region. The simulated kuiperoidal dust, in addition to asteroidal and cometary dust, might represent a third possible source of the zodiacal light in the Solar system.

Gorkavyi, Nick N.↗

Rapid Prototyping Integrated With Nondestructive Evaluation and Finite Element Analysis

Most reverse engineering approaches involve imaging or digitizing an object then creating a computerized reconstruction that can be integrated, in three dimensions, into a particular design environment. Rapid prototyping (RP) refers to the practical ability to build high-quality physical prototypes directly from computer aided design (CAD) files. Using rapid prototyping, full-scale models or patterns can be built using a variety of materials in a fraction of the time required by more traditional prototyping techniques (refs. 1 and 2). Many software packages have been developed and are being designed to tackle the reverse engineering and rapid prototyping issues just mentioned. For example, image processing and three-dimensional reconstruction visualization software such as Velocity2 (ref. 3) are being used to carry out the construction process of three-dimensional volume models and the subsequent generation of a stereolithography file that is suitable for CAD applications. Producing three-dimensional models of objects from computed tomography (CT) scans is becoming a valuable nondestructive evaluation methodology (ref. 4). Real components can be rendered and subjected to temperature and stress tests using structural engineering software codes. For this to be achieved, accurate high-resolution images have to be obtained via CT scans and then processed, converted into a traditional file format, and translated into finite element models. Prototyping a three-dimensional volume of a composite structure by reading in a series of two-dimensional images generated via CT and by using and integrating commercial software (e.g. Velocity2, MSC/PATRAN (ref. 5), and Hypermesh (ref. 6)) is being applied successfully at the NASA Glenn Research Center. The building process from structural modeling to the analysis level is outlined in reference 7. Subsequently, a stress analysis of a composite cooling panel under combined thermomechanical loading conditions was performed to validate this process.

Abdul-Aziz, Ali↗

Interferometric tomography of continuous fields with incomplete projections

Interferometric tomography in the presence of an opaque object is investigated. The developed iterative algorithm does not need to augment the missing information. It is based on the successive reconstruction of the difference field, the difference between the object field to be reconstructed and its estimate, only in the difined region. The application of the algorithm results in stable convergence.

Cha, Soyoung S.↗

A Novel Anatomic Reconstruction for Posterior Tibialis Tendon in Treatment of Flexible Adult‐Acquired Flatfoot Deformity

Objective To present a novel approach for the anatomic reconstruction of the posterior tibialis tendon (PTT) in restoring plantar insertions and evaluate its efficiency in treating flexible adult‐acquired flatfoot deformity (AAFD) caused by PTT dysfunction. Methods For AAFD treatment, a novel PTT reconstruction method was presented. The current study involved 16 patients, including three men, and 13 women, from August 2017 to July 2019. The mean age was 43.2 ± 15.1 years (21–64 years). The innovative PTT repair method was used on all patients. The treatment involved performing a traditional Flexor Digitorum Longus (FDL) transfer in the navicular tuberosity and suturing the plantar insertions to FDL as tension was applied to tighten the plantar structures of the foot. The results were retrospectively analyzed. The clinical outcome was assessed using the pain visual analogue scale (VAS), the satisfaction VAS, and the American Orthopedic Foot and Ankle Society ankle–hindfoot scale (AOFAS‐AH). Isokinetic testing was performed using a dynamometer at 60°/s and 120°/s for inversion/eversion and plantarflexion/dorsiflexion, respectively, to determine the mean peak torque. Radiographic measurements were employed to assess the outcomes. Results Bone surgeries combined with the modified anatomic PTT reconstruction were performed on patients with medializing calcaneal osteotomy in 12 (75%) patients and subtalar joint fusion in four (25%) patients. The branch linking to the plantar insertions was detected in every case, with an average width of 3.5 ± 0.8 mm (3.1–4.3 mm). All patients were followed up for the mean of 16.8 ± 1.8 months (range, 15–20 months). The average postoperative functional scores, including pain VAS, satisfaction VAS, total AOFAS‐AH, and all AOFAS‐AH sub‐scales, steadily improved during the follow‐up. In the last follow‐up, isokinetic testing revealed no loss of plantarflexion strength ( p = 0.350 and 0.098) and significant improvement in the inversion strength ( p = 0.007 and 0.008) in the operated ankles at 60°/s and 120°/s. Radiographic outcomes, particularly the talar head uncovering, improved significantly after more than a year ( p < 0.001 for all). Conclusions The novel technique for PTT reconstruction in restoring the plantar insertions serves as an effective procedure in treating AAFD caused by PTT dysfunction in terms of delivering a consistent improvement in ankle inversion strength, medial longitudinal arch restoring, and satisfactory clinical outcomes.

Hu, Yong↗

Evaluating multi-slice ptychography tomography for X-ray imaging

X-ray ptychography typically relies on single-slice reconstruction approaches that assume minimal beam propagation through the specimen. However, this approximation breaks down for thick samples or when using high numerical aperture optics, leading to reconstruction artifacts due to multiple scattering. Multi-slice ptychographic tomography (MSPT) addresses this limitation by explicitly modeling beam propagation through the specimen while reducing angular sampling requirements for tomography, but its performance depends critically on reconstruction parameters and experimental conditions. Here, we systematically evaluate MSPT using numerical simulations and experimental X-ray datasets to understand how factors such as object thickness, optical parameters, and initialization strategies affect reconstruction accuracy. We demonstrate that informed object initialization significantly improves depth resolution and enables accurate projection extension, reducing the angular sampling requirements for tomographic reconstruction. Experimental demonstration confirms that MSPT produces reconstructions with reduced artifacts, establishing it as a robust approach for nanoscale imaging at modern synchrotron facilities.

Luktuke, Amey [Argonne National Laboratory (ANL), ↗