Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear science & technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Using personal monitoring data to derive organ doses for medical radiation workers in the Million Person Study—considerations regarding NCRP Commentary no. 30

The study of low dose and low-dose rate exposure is of central importance in understanding the possible range of health effects from prolonged exposures to radiation. The One Million Person Study of Radiation Workers and Veterans (MPS) of low-dose health effects was designed to evaluate radiation risks among healthy American workers and veterans. The MPS is evaluating low-dose and dose-rate effects, intakes of radioactive elements, cancer and non-cancer outcomes, as well as differences in risks between women and men. Medical radiation workers make up a large group of individuals occupationally exposed to low doses of radiation from external x-ray/gamma exposures. For the MPS, about 100 000 United States medical radiation workers have been selected for study. The approach to the complex dosimetry circumstances for such workers over three to four decades of occupation were initially and broadly described in National Council on Radiation Protection and Measurements (NCRP) Report No. 178. NCRP Commentary No. 30 provides more detail and describes an optimum approach for using personal monitoring data to estimate lung and other organ doses applicable to the cohort and provides specific precautions/considerations applicable to the dosimetry of medical radiation worker organ doses for use in epidemiologic studies. The use of protective aprons creates dosimetric complexity. It is recommended that dose values from dosimeters worn over a protective apron be reduced by a factor of 20 for estimating mean organ doses to tissues located in the torso and that 15% of the marrow should be assumed to remain unshielded for exposure scenarios when aprons are worn. Conversion coefficients relating personal dose equivalent, H p (10) in mSv, to mean absorbed doses to organs and tissues, D T in mGy, for females and males for six exposure scenarios have been determined and presented for use in the MPS. This Memorandum summarises several key points in NCRP Commentary No. 30.

Environmental Sciences & Ecology↗

Four-decade follow-up of a plutonium-contaminated puncture wound treated with Ca-DTPA

Contaminated wounds are a common route of internal deposition of radionuclides for nuclear and radiation workers. They may result in significant doses to radiosensitive organs and tissues in an exposed individual's body. The United States Transuranium and Uranium Registries' whole-body donor (Case 0303) accidentally punctured his finger on equipment contaminated with plutonium nitrate. The wound was surgically excised and medically treated with intravenous injections of Ca-DTPA. A total of 16 g Ca-DTPA was administered in 18 treatments during the 2 months following the accident. Ninety-three urine samples were collected and analysed over 14 years following the accident. An estimated 239 Pu activity of 73.7 Bq was excreted during Ca-DTPA treatment. Post-mortem radiochemical analysis of autopsy tissues indicated that 40 years post-accident 21.6 ± 0.2 Bq of 239 Pu was retained in the skeleton, 12.2 ± 0.3 Bq in the liver, and 3.7 ± 0.1 Bq in other soft tissues; 1.35 ± 0.02 Bq of 239 Pu was measured in tissue samples from the wound site. To estimate the plutonium intake, late urine measurements, which were unaffected by chelation, and post-mortem radiochemical analysis results were evaluated using the IMBA Professional Plus software. The application of the National Council on Radiation Protection and Measurements wound model with an assumption of intake material as a predominantly strongly retained soluble plutonium compound with a small insoluble fraction adequately described the data (p = 0.46). The effective intake was estimated to be 50.2 Bq of plutonium nitrate and 1.5 Bq of the fragment. Here, the prompt medical intervention with contaminated tissue excision and subsequent Ca-DTPA decorporation therapy reduced 239 Pu activity available for uptake and long-term retention in this individual's systemic organs by a factor of 38.

239Pu↗

Cytogenetic follow-up studies on humans with internal and external exposure to ionizing radiation

Cells exposed to ionizing radiation have a wide spectrum of DNA lesions that include DNA single-strand breaks, DNA double-strand breaks (DSBs), oxidative base damage and DNA-protein crosslinks. Among them, DSB is the most critical lesion, which when mis-repaired leads to unstable and stable chromosome aberrations. Currently, chromosome aberration analysis is the preferred method for biological monitoring of radiation-exposed humans. Here, stable chromosome aberrations, such as inversions and balanced translocations, persist in the peripheral blood lymphocytes of radiation-exposed humans for several years and, therefore, are potentially useful tools to prognosticate the health risks of radiation exposure, particularly in the hematopoietic system. In this review, we summarize the cytogenetic follow-up studies performed by REAC/TS (Radiation Emergency Assistance Center/Training site, Oak Ridge, USA) on humans exposed to internal and external radiation. In the light of our observations as well as the data existing in the literature, this review attempts to highlight the importance of follow-up studies for predicting the extent of genomic instability and its impact on delayed health risks in radiation-exposed victims.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconstructed lung doses for the million person study cohort of 26,650 Tennessee Eastman corporation workers employed between 1942 and 1947

Abstract Tennessee Eastman Corporation workers were exposed to uranium dust resulting in high-linear energy transfer (LET) irradiation to lung tissue. In this work, radiation lung doses were reconstructed for 26 650 men and women working at the plant between 1942 and 1947. Site air monitoring data of uranium concentrations and payroll records were used to determine the daily inhaled activities and annualized lung doses. Variations in the activity median aerodynamic diameter of the uranium dust, the solubility of particulate matter in the lungs and the sex-specific breathing rate were investigated as part of a sensitivity analysis. Male and female mean lung doses of 18.9 and 32.7 mGy, respectively, from high-LET alpha irradiation, and there was general agreement with evaluations from previously published epidemiological studies. Annual lung dose estimates and sensitivity analysis for the 26 650 workers in the TEC cohort have been archived on the United States Department of Energy Comprehensive Epidemiologic Data Resource.

61 RADIATION PROTECTION AND DOSIMETRY↗

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗

URINARY EXCRETION OF PLUTONIUM IN MAYAK WORKERS DURING AND AFTER CA-DTPA ADMINISTRATION

Chelation therapy is sometimes used after potential exposures to plutonium to increase urinary excretion of the radionuclide to improve the accuracy of bioassay measurements. The purpose of this report is to describe the enhancement of urinary excretion of plutonium during and after the administration of the trisodium salt of calcium diethylenetriaminepentaacetate (Ca-DTPA) daily for 3 d to a group of male and female plutonium workers from the Mayak Production Association in Ozyorsk, Russia. One-hundred and two cases (18 females and 84 males) were selected where urinary contents of plutonium, prior to chelation, exceeded the detection threshold. Daily urine collections were obtained during the 3 d of Ca-DTPA treatments. In addition, 58 of these cases had urine bioassays at 1–45 d after chelation. The daily enhancement over baseline values excretion of plutonium was found to be 50.4×/1.4 (geometric mean and geometric standard deviation); 58.9×/1.2; 72.9×/1.4 in the first, second and third days of Ca-DTPA administration. The mean enhancement for the 3-d period was 60.1×/1.7. The rate of plutonium excretion from 1 to 45 d after chelation decreased with a half-period of 3.9 d and the chelation enhancement factor (Кenh-i) is described by the function Кenh-i = (0.79 ± 0.24) + (42.9 ± 1.2) × e-(0.18 ± 0.01) × day.

Environmental Sciences & Ecology↗

Electron paramagnetic resonance dose measurements in teeth of tissue donors to the United States Transuranium and Uranium Registries

Abstract The United States Transuranium and Uranium Registries (USTUR) is a research program that studies actinide biokinetics in occupationally exposed individuals with known intakes of these elements. Electron paramagnetic resonance (EPR) in tooth enamel was applied to reconstruct external doses of nine USTUR registrants. Only in two cases there is a reasonable agreement between the EPR-measured dose and the worksite external dose record. For two registrants, high EPR doses can be explained by possible cancer radiotherapy. For the remaining five cases, EPR doses significantly exceed official occupational doses with no plausible explanation for the observed discrepancy. More EPR dose measurements need to be done to explain this anomaly.

Environmental Sciences & Ecology↗

Latent bone modelling for estimation of plutonium concentration in skeleton of former nuclear workers

Abstract The skeleton is a major plutonium retention site in the human body. Estimation of the total plutonium activity in the skeleton is a challenging problem. For most tissue donors at the United States Transuranium and Uranium Registries, a limited number of bone samples is available. The skeleton activity is calculated using plutonium activity concentration (Cskel) and skeleton weight. In this study, latent bone modelling was used to estimate Cskel from the limited number of analysed bone samples. Data from 13 non-osteoporotic whole-body donors were used to develop latent bone model (LBM) to estimate Cskel for seven cases with four to eight analysed bone samples. LBM predictions were compared to Cskel estimated using an arithmetic mean in terms of accuracy and precision. For the studied cases, LBM offered a significant reduction of uncertainty of Cskel estimate.

Environmental Sciences & Ecology↗

EPR Investigation of Temporal and Thermal Stability of Irradiated Sweeteners

Abstract Electron paramagnetic resonance was used to study the dosimetric properties of commercial sweeteners (sucrose, saccharin, and stevia). The results concluded that sugar has dosimetric properties of interest, which makes it suitable for dose reconstruction, emergency response, and nuclear forensics applications. The radiation dose response was investigated by irradiating samples up to 10 Gy and found to be linear. The post-irradiation stability of samples was observed to be useful for the intended applications. The results showed that the post-irradiation intensities vary from one sample to another, with the general trend demonstrating a small increase in intensities shortly after irradiation followed by an approximately constant leveling out. Finally, the effect of isochronal annealing was studied by heating samples to various temperatures. The results showed an overall stable behavior of the signal below melting temperature.

Environmental Sciences & Ecology↗

Psychosomatic Bias in Low-dose Radiation Epidemiology: Assessing the Role of Radiophobia and Stress in Cancer Incidence

Abstract Historical assessment of radiation effects at low doses (below 0.2 Sv) are generally the result of back extrapolation from higher doses, which are known to have a linear relation between risk and dose. There are multiple counter-examples, and some literature argues that a threshold, nonlinear, or even a beneficial effect (hormeisis) can occur from radiation below these doses. The common theme found in all of these studies stems from the traditional approach of correlating disease rates to stimulus and then effectively curve-fitting the result toward zero dose. What has not been considered in general are the personal stress levels of the exposed individuals due to fear of cancer from low doses. The increased levels of cortisol due to the psychological stress from fear or depression has been shown in the literature to increase cancer probability. The extent to which low-dose exposed individuals were highly fearful or stressed from the radiation exposure would then give rise to elevated cancer based on stress rather than a fundamental radiogenic mechanism. If the population under epidemiological study is aware of a potential historical exposure (no matter how small) and has then lived under stress from fear or depression due to that exposure, the psychosomatic effects will bias the epidemiology accordingly and so should be quantified and accounted for as done with the effects of smoking. Health Phys. 129(0):000-000; 2025

Environmental Sciences & Ecology↗

A Novel Dosimetry Method for Small Animal Irradiators Using 3D-printed Mouse Phantoms and Alanine Dosimeters

Abstract Accurate dosimetry is a crucial component of small animal and preclinical irradiation studies. Various dosimetry options are available but fail to characterize complex geometries and variable energy spectra of modern x-ray irradiators accurately. These options also lack national/international standards of recognition. This paper presents a novel dosimetry system, Dosequate, which uses murine phantoms embedded with alanine dosimeters and paired with x-ray energy spectra corrections to deliver consistent and accurate dosimetry measurements. This study compares Dosequate measurements against a Precision X-RAD 320 internal ion chamber and the treatment planning system of an Xstrahl Small Animal Radiation Research Platform. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. The Dosequate dosimetry method provides a robust and standardized approach for measuring absorbed dose in small animal irradiators. Its accuracy, reproducibility, and ability to account for complex irradiation geometries make it a valuable tool for preclinical research. This system has the potential to significantly improve the intercomparability of studies across different facilities and enhance the reliability of results.

Environmental Sciences & Ecology↗

Cooperative spin coupling in PrFeO3

A transition from crystal-field to spin wave excitations has been experimentally observed in PrFeO3 using inelastic neutron scattering. Theoretical modeling with density functional theory and the mean field random phase approximation successfully reproduces the experimental observations and allows extraction of the values for the various exchange interactions. The study reveals that the strong coupling between the two magnetic sublattices of Pr and Fe is the fundamental mechanism underlying the low-temperature Pr magnetism. This coupling, analogous to the Dicke cooperative interaction between atoms and photons, polarizes the Pr moments, enhances the Pr-Pr interactions, and contributes to the formation of a quasidoublet, leading to the transition from single-particle to collective excitations within the Pr sublattice. Furthermore, this coupling induces spin reorientation on the Fe sublattice. The manipulation of magnetic moments via spin waves is achievable through the coupling between different magnetic sublattices in a bulk material containing multiple magnetic ions.

Garlea, Vasile [ORNL] (ORCID:0000000253227271)↗