Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “new construction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Pilgrim Hot Springs Building Dimensions and Energy Modeling

This dataset was created to model the anticipated heating load of a geothermal project in development for the historical site of Pilgrim Hot Springs, and adds to the history of geothermal studies at the site. Models include an historical building (Nun's Quarters), existing modern buildings (Caretaker's Cabin, Igloo, Visitor's Cabin, Staff Shower Hut), and planned building projects (Changing Room, Greenhouse). Modeling results were used to determine feasible geothermal system typologies. The previous study linked below ("Village of Solomon Development of Energy Efficiency Building Standards for New Construction") feeds in to this project. The dataset includes DWG drawings and AKwarm energy models (.hm2) of a subset of existing buildings at the site of Pilgrim Hot Springs. All buildings were modeled in their current state, and some were additionally modeled with improvements to the building envelope. Energy modeling results exported from AKwarm include .htm and .png images.

AKwarm↗

Clifford orbits from cayley graph quotients

We describe the structure of the $n$-qubit Clifford group $\mathcal{C}_n$ via Cayley graphs, whose vertices represent group elements and edges represent generators. In order to obtain the action of Clifford gates on a given quantum state, we introduce a quotient procedure. Quotienting the Cayley graph by the stabilizer subgroup of a state gives a reduced graph which depicts the state's Clifford orbit. Using this protocol for $\mathcal{C}_2$, we reproduce and generalize the reachability graphs. Since the procedure is state-independent, we extend our study to non-stabilizer states, including the W and Dicke states. Furthermore, our new construction provides a more precise understanding of state evolution under Clifford circuit action.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Epidemiology, Clinical Features, and Outcomes of Coccidioidomycosis, Utah, 2006–2015

On the basis of a 1957 geographic Coccidioides seropositivity survey, 3 counties in southwestern Utah, USA, were considered coccidioidomycosis-endemic, but there has been a paucity of information on the disease burden in Utah since. We report findings from a recent clinical and epidemiologic study of coccidioidomycosis in Utah. To describe clinical characteristics, we identified all coccidioidomycosis cases in an integrated health system in the state during 2006–2015. For epidemiologic analysis, we used cases reported to the Utah Department of Health during 2009–2015. Mean state incidence was 1.83 cases/100,000 population/year. Washington County, in southwestern Utah, had the highest incidence, 17.2 cases/100,000 population/year. In a generalized linear model with time as a fixed effect, mean annual temperature, population, and new construction were associated with regional variations in incidence. Using these variables in a spatiotemporal model, we estimated the adjusted regional variation by county to predict areas where Coccidioides infections might increase.

60 APPLIED LIFE SCIENCES↗

High-Order Multipole and Binary Love Number Universal Relations

Using a data set of approximately 2 million phenomenological equations of state consistent with observational constraints, we construct new equation-of-state-insensitive universal relations that exist between the multipolar tidal deformability parameters of neutron stars, Λ l , for several high-order multipoles (l = 5,6,7,8), and we consider finite-size effects of these high-order multipoles in waveform modeling. We also confirm the existence of a universal relation between the radius of the 1.4M ⊙ NS, R 1.4 and the reduced tidal parameter of the binary, Λ˜, and the chirp mass. We extend this relation to a large number of chirp masses and to the radii of isolated NSs of different mass M, R M . We find that there is an optimal value of M for every M such that the uncertainty in the estimate of R M is minimized when using the relation. We discuss the utility and implications of these relations for the upcoming LIGO O4 run and third-generation detectors.

97 MATHEMATICS AND COMPUTING↗

Transforming Windows from Energy Liabilities to Zero-Energy Assets: Next-Generation Solutions for Buildings

Windows have traditionally contributed to a building's HVAC load, but they can also become a source of net energy gain or even operate as zero-energy components. For heating applications, highly insulating windows can harness more solar heat than the energy lost through them, transforming windows from energy liabilities to assets. Dynamic glazings provide further benefits by regulating solar heat gain, reducing cooling loads in summer and heating demands in winter. This simulation study focuses on developing the next generation of zero-energy windows (ZEW) for residential new construction. Through annual energy simulations across climate zones 1-8, ZEW performance benchmarks were established based on current code-level buildings, and we've identified the regions where meeting ZEW standards are most achievable. This work evaluates both static and dynamic window technologies, assessing their effects on annual energy use and cost. Key findings demonstrate that ZEW performance is achievable across diverse climate zones, with specific regional requirements. Most climate zones from 3-8 can achieve ZEW with specific configurations, while some warm climates (1-2) appear challenging for ZEW implementation. Climate zones 4-6 consistently allow for zero energy window implementation, offering multiple pathways through either static or dynamic window technologies. Colder climate zones (7-8) ZEW products allow for higher SHGC values while requiring low U-values.

Yu, Lili↗

Air Return Strategies and Airborne SARS-CoV-2

Dedicated ducted air return per zone for heating, ventilating, and air-conditioning (HVAC) systems is sometimes claimed to be a superior technique over plenum return strategy from the viewpoint of exposure reduction to airborne pathogens. While both the return strategies have advantages, there is limited evidence in the literature as to which strategy is superior merely from a standpoint of building vulnerability to airborne contaminants. We performed multizonal airborne contaminant dispersion modelling using CONTAM to simulate the overall building vulnerability to airborne SARS-CoV-2 aerosols when released in an office building and evaluated the two air return strategies. Results showed that for ducted returns, maintaining negative pressure in the release zone coupled with 100% outdoor air supply can greatly reduce overall building vulnerability. However, for a building maintained under a slight positive pressure and a recirculated air percentage as low as 31%, ducted returns do not necessarily outperform plenum returns in terms of overall building vulnerability to airborne pathogens. Building-specific details and factors that are not easily represented with multizone modelling are important, making general preferential statements for either strategy difficult to make. Insights from this study can guide new construction and retrofits of buildings both during and after the COVID-19 pandemic with the aim of safe re-occupancy of buildings while keeping the buildings resilient against potential future epidemics spread by airborne agents.

Shrestha, Prateek↗

Design Readiness And Maturity Assessment (DRAMA) Tool for Advanced Reactors

Abstract – This research is developing a formal, repeatable method to assess the readiness and maturity of an advanced nuclear reactor design for licensing and deployment. This design readiness and maturity assessment (DRAMA) tool will be capable of determining the readiness of the design and of all parties needed to bring a particular advanced reactor design to fruition. Beneficiaries and stakeholders include the design team, research organizations (required to collect needed data and develop design tools), standards organizations, research facilities to support gathering of needed data, supply chain and construction organizations, and everyone responsible for legal and regulatory infrastructure (including defining import-export requirements). Recent experience has shown that even the most experienced engineering and construction organizations, with decades of experience in the nuclear power business, have had significant challenges in bringing designs to completion, licensing the designs, and constructing new plants. For new entries into the field, simply understanding the unique environmental and regulatory requirements have been daunting. A significant part of the challenge is that new entries into the market do not know what they don't know. This tool will provide design teams a better understanding of their readiness to proceed to licensing (and other steps in the process), while at the same time providing a valuable metric for other interested organizations, such as funding agencies, national regulators, and international markets. The DRAMA tool will provide an assessment of the likelihood of successfully completing licensing and deployment and will also create the capability to assess the ability of regulatory infrastructure and the supply chain to support the deployment of any design or class of designs. It will also help prioritize research and policy efforts to improve the likelihood of deployment of the next generation of advanced reactors.

Arndt, Steven↗

NREL Helps Hydropower Projects Navigate Complex Regulatory Currents

Hydropower accounts for about 37% of U.S. renewable electricity generation. But before industry members can license and construct new projects or relicense existing projects, they must navigate complex approvals from federal, state, and tribal authorities. These regulations provide critical protections for water quality, species, cultural resources, and recreation, but they can also increase the costs, risks, and uncertainties to license or relicense projects.

HYDRO ENERGY↗

Simulation of a PCM Integrated Heat Pump Using Time-of-Use Utility Structure based Control Strategy for Demand Response

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries and constructing new peaking power plants. The aggressive carbon reduction goals of the United States are accelerating the electrification of building equipment. If space heating and cooling in the US were electrified using conventional heat pump technologies, the winter electric grid peak would approximately double. Integrating TES with heat pump (HP) enables electrification of space cooling and heating devices without overtaxing the grid.This paper evaluates the benefits of a novel phase change material (PCM) integrated heat pump configuration via simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation.To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

Li, Zhenning↗

In Hot Water! The Challenges and Barriers of Decarbonizing Water Heating in Multifamily Buildings: Preprint

Domestic hot water heating is responsible for 32% of the total energy consumption in multifamily buildings and offers a significant decarbonization opportunity. An extensive market assessment was conducted to understand and document key technical and economic barriers to electrification of domestic water heating in multifamily buildings throughout the U.S. Through the program, 77 interviews were conducted to understand key market drivers and technical challenges associated with electrification of water heating systems in both retrofit and new construction scenarios. Interviewees encompassed a wide range of stakeholders in the ecosystem surrounding water heating systems, including suppliers, manufacturers, designers, owners, utilities, and developers. This paper documents key interview takeaways, including an extensive list of market barriers, technical challenges, and sought-after technology attributes that can inform pertinent design criteria for electric water heating research, development, and deployment efforts. Among economics and energy efficiency features, interviewees overwhelmingly alluded to space constraints, cold air exhaust, and lack of clear guidance regarding distributed versus centralized design selections as key challenges associated with mass adoption of electric water heating. Owners and developers seek systems with minimal footprint, which maximize rentable space and profits. Moreover, distributed heat pump solutions should balance ducting costs that mitigate cold exhaust entrainment into conditioned zones. Lastly, the market needs clear guidance regarding the selection of distributed versus central electric hot water systems.

challenges of water heating electrification↗

Cold-Climate Packaged Heat Pumps - Resistance is Futile

The U.S. currently has a large market for room/zonal space conditioning equipment focused primarily on cooling, namely packaged terminal air conditioners (PTACs), packaged terminal heat pumps (PTHPs), and room air conditioners. This equipment largely relies on electric resistance for heating, particularly when outdoor temperatures fall to 40°F or below, presenting a compelling opportunity for energy savings and carbon reductions from reverse cycle heating. This paper provides an overview of cold climate packaged heat pump technologies in the market capable of high output down to outdoor temperatures of 5°F and identifies the technological and market barriers to adoption. For state-of-the-art cold climate packaged heat pumps sold in the retrofit market, defrost meltwater management is the principal barrier to implementation. An energy use analysis is conducted on state-of-the-art cold climate packaged heat pumps for heating and cooling loads by building vintage and climate zone. Potential solutions to defrost meltwater are proposed and modeled for their impact on heating energy efficiency. A national impact assessment estimates the aggregate energy savings and carbon reductions if cold climate packaged heat pumps were to replace existing PTACs and PTHPs in the U.S. building stock. A national, two-track approach is proposed for increasing market adoption in the replacement and new construction markets.

ACEEE Summer Study, cold climate, heat pumps, ccph↗

User Friendly Web-Based Tool to Assess the Energy Efficiency and Durability of Residential Wall Retrofits

According to the U.S. Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies, building envelope wall energy loss in the United States accounts for about 5.9 x 1010 kWh or 2 quads of energy annually, costing homeowners and occupants billions of dollars. Enclosure retrofits targeting these losses can save significant energy, reduce greenhouse gas emissions, and save occupants millions of dollars over time. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established, represent approximately 68 percent of the residential building stock in the country, often having significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation have heating and cooling losses that can represent a substantial portion of utility bills.High-performance building envelope retrofit systems are rarely selected for retrofit applications. Current solutions are expensive and/or unfamiliar to many designers, builders, contractors, and code officials and therefore are perceived as risky. The dominant perceived risk is durability specifically related to condensation and moisture accumulation in the building envelope component.The Building Science Advisor (BSA) is a rule-based expert system web-based tool that was originally developed to assist building professionals in designing energy efficient and durable wall systems for new construction. With the present focus being placed on upgrading the existing building stock, a retrofit module has been developed that, based on the location, existing construction, and planned retrofit strategy, provides recommendations on how to address the retrofit in a manner that will perform in accordance with IECC 2018 building code and not create a durability problem. This paper will describe the development of this tool and demonstrate its features and capabilities.

Desjarlais, Andre Omer↗

Identifying Opportunities and Recommendations for the Integration of Advanced Reactors for Industrial Heat and Electricity Users

Nuclear power in the United States has been used traditionally to provide baseload electric power to the grid. Advancements in nuclear power to create smaller and safer reactors have renewed interest in nuclear as a source of both heat and electricity for a variety of applications. There is great interest in coupling nuclear reactors with industrial applications because nuclear power is a low carbon energy source that can be utilized for process heating, hydrogen generation, on-site electricity demand, and more. Idaho National Laboratory is developing guidelines to identify and assist industrial heat and electricity decarbonization by integrating with nuclear power plants (NPPs) to provide clean, abundant, and dispatchable energy. Considerations include specific industrial hazards which impact NPP siting, heat transport requirements and associated technologies, and implementation feasibility based on site-specific demand profiles. To assess integration feasibility, facility process models are developed based on real data obtained from a survey of baseline requirements and process information from industrial facilities in the United States. An assessment of safety and siting requirements is also performed to determine how nuclear industrial pairings could meet licensing requirements for NPPs. In addition, site characterization of an industrial plant is essential to determining the feasibility and suitable integration methods for each industry. Characterization includes facility distance from the nearest population center, site size, rail or water transport availability, and proximity to undeveloped land. These characteristics are important to determine reactor- or industry-side design requirements for safe, efficient operation. The siting and technical data assessment will reveal opportunities for single-use nuclear integration and co-location opportunities for industries to share benefits from a single reactor. In addition to existing facilities, this “energy-park” style cooperation could include new construction like data centers which can cost-share energy investments or provide a stable demand-and-revenue stream to the investor. Deliverables will contain a library of documents and models to guide various industries toward understanding nuclear technologies based on their users’ needs. This paper is a summary of the current project status, and provides insights on suitable pairings for specific industries and reactor technologies

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thin Triples Expand the Affordable High-Performance Window Options For Retrofit

Sales of high-performance triple-pane windows make up only a small fraction (~3%) of total window sales in the United States with relatively stagnant market growth over the past 20 years. High costs have been the most commonly cited barrier to adoption. The emergence of thin triples that can fit into the glazing pocket of existing double pane windows has the potential to revolutionize the high-performance window market in particular the retrofit market by enabling glass only upgrades for situations where the frames are still in good condition. The retrofit market has other unique challenges not found in new construction that can be solved or reduced by thin triple pane windows. Insert replacements are often pursued instead of full frame replacement, in retrofits, this method reduces the net free area of a window and can turn an egress window into one that no longer meets the net free area requirements for egress. Thin frames minimize such occurrences. However, these thin frames can often not accommodate the weight of a traditional triple pane, thin triples can bring high performance to this situation. Thicker frames can also increase retrofit labor costs because the interior drywall and/or trim molding needs to be cut back to accommodate a thicker frame while thin triples can fit into frames that match the thickness of the existing window. This paper presents information about field test experiences the highlight these retrofit advantages from experiencing the challenges associated with retrofitting a thick frame as well as the supply chain, purchasability, material and labor costs, and real-world energy and non-energy performance associated with the IGU only replacement method.

window retrofits, thin triple-pane windows, high p↗

Scaling Up to Zero Energy Ready - and Down to 530 ft2

There is a demonstrated need for affordable housing and smaller homes. Reduced square footage new construction projects present a solution for this growing need. Completion of these types of projects is not without challenges however, as high efficiency building measures present problems with proper equipment sizing and indoor environmental quality. This case study describes the support provided by FSEC to the Manatee County Habitat for Humanity to create a small footprint home design that qualifies for Zero Energy Ready Home (ZERH) certification in Florida. Specific measures to address equipment sizing challenges, and interior air quality targets are identified among other construction elements that contribute to qualifying for ZERH certification. Discussion of the approach to meeting these challenges is informative to other efforts to build to above code standards in hot humid climates, and other regions.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Powering Data Centers with Clean Energy: A Techno-Economic Case Study of Nuclear and Renewable Energy Dependability

Rising data demands from artificial intelligence (AI) and large language models (LLMs) generating images, videos, and text have prompted increased need for larger and more robust data centers in the United States. Major companies interested in these larger data centers face the choice of linking them to existing regional grids, building stand-alone power supplies onsite, or a combination of both. The request, review, and approval process for new transmission lines to grids in the United States, however, has grown in recent years to times spans rivaling those of new construction for nuclear power plants. Building an islanded power supply for each data center is therefore becoming a prominent option. In this case study, several technologies are modeled in techno-economic simulations for long-term system costs subject to fixed electricity demand from a singular data center. A 250 MWe data center is assumed with additional 50 MWe for resiliency. Techno-economic simulations are conducted using the Holistic Energy Resource Optimization Network (HERON) software, which is a part of the Framework for Optimization of Resources and Economics (FORCE) tool suite. Technologies considered include solar, wind, lithium-ion batteries, and several types of nuclear reactors: large-scale reactors, small modular reactors, and microreactors. A low- and high-cost estimate for each technology is assumed to develop a range of expected economic performance. Low-cost estimates included several clean energy production tax credits. Different combinations of renewable energy generators with nuclear reactors are considered, ranging from a fully renewable-powered data center to a fully nuclear-powered data center. Historic time series of wind and solar availability from the Texas grid are used to train a reduced order model; this model then generates unique time series with similar characteristics of the training dataset. Multiple scenarios of weather and subsequent operations are simulated for each renewable-nuclear combination to determine total costs throughout the project lifetime. Fully renewable-powered configurations required large amounts of installed capacity (GW scale) in the simulations to meet the fixed demand of the data center. This is due to some scenarios in the historical dataset which captured low-wind and low-solar days, requiring over-building of these technologies as well as batteries to compensate for the low amounts of electricity generation. Fully nuclear-powered configurations outperformed the fully renewable and mixed renewable-nuclear configurations in terms of cost, with ranges between $1B and $10B in 2023 USDs compared to $40B+ for fully renewable configurations. Of the nuclear technologies, small modular reactors performed better economically than large-scale nuclear models due to lower projected capital costs, and both performed better than the microreactor models. These results demonstrate the applicability of firm, dispatchable electricity resources from baseload generators like nuclear power plants for operating facilities that run at constant power without daily variability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Update on Integrity Monitoring, Prediction and Assessment, Corrosion Control, and Repair of the Hanford Storage Tanks

DOE has launched a multi-year research program with the focus of preserving and increasing available volume for waste storage at Hanford. The long-term availability and operability of the Hanford Double Shell Tanks (DST) is critical to the completion of the Hanford mission. Maintaining the integrity of the tank will involve having a technology for repair or refurbishment of a DST should the tank function be compromised by degradation, monitoring the tank for indications of accelerated degradation, developing a means for mitigating accelerated degradation, and evaluating options for increasing the storage capacity in the tank farm without constructing new tanks. The project work was started in the middle of 2024; significant progress has been made in the following four areas: (i) tank refurbishment using a high performance grout and an epoxy sealant layer system, (ii) developing a chemically and radiologically stable reference electrode, (iii) designing and implementing a cathodic protection system to mitigate underside corrosion of DST secondary shells, and (iv) exploring evaporation to increase waste storage capacity.

Shukla, Pavan [Savannah River National Laboratory ↗