Development of a high fidelity model of the CROCUS experimental reactor

Measurements of scalar flux distributions with fine spatial and energy resolutions are needed to remedy one of the validation shortcomings of the novel neutronics full core solvers, such as MPACT and nTRACER. While a very detailed resolution of the flux can be calculated with such codes, only a limited experimental data set is available to check their accuracy. Such type of measurements are on-going at the zero power reactor CROCUS, operated at the Laboratory for Reactor Physics and System Behaviours of the EPFL, thanks to the development of advanced miniature neutron detection systems. This kind of experimental data would provide the community with a suitable benchmark for the validation of high fidelity neutronics solvers. In parallel, a multi-physics solver for steady-state and transient analysis of nuclear reactors, named GeN-Foam, has been developed. Based on the finite-volume OpenFOAM library, GeN-Foam provides us with enough flexibility to analyze non-conventional reactor geometries such as that of CROCUS. While CROCUS heterogeneities cannot be modeled by MPACT and nTRACER for the moment, GeN-Foam offers a unique opportunity to build a high fidelity model which mimics these codes' method to reach sub-pin simulation resolution. This document aims at describing the work achieved to get from the existing GeN-Foam model of the CROCUS reactor based on a structured mesh and using the neutron diffusion, the first high-fidelity model using discrete ordinates method as an approximation to neutron transport and an unstructured mesh for inter lattice water gap description and sub-pin heterogeneous modeling. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Serpent neutronics model of Wendelstein 7-X for 14.1 MeV neutrons

In this work, a Serpent 2 neutronics model of the Wendelstein 7-X (W7-X) stellarator is prepared, and an response function for the Scintillating-Fibre neutron detector (SciFi) is calculated using the model. The neutronics model includes the simplified geometry for the key components of the stellarator itself as well as the torus hall. The objective of the model is to assess the 14.1 MeV neutron flux from deuteron-triton fusions in W7-X, where the neutrons are modelled only until they have slowed down to 1 MeV energy. The key messages of this article are: demonstration of unstructured mesh geometry usage for stellarators, W7-X in particular; technical documentation of the model and first insights in fast neutron behaviour in W7-X, especially related to the SciFi: the model indicates that the superconducting coils are the strongest scatterers and block neutrons from large parts of the plasma. The back-scattering from e.g. massive steel support structures is found to be small. The SciFi will detect neutrons from an extended plasma volume in contrast to having an effective line-of-sight.

14 MeV↗

Measurement of the 252 Cf ⁢(sf) prompt fission neutron spectrum utilizing 12 C ⁡(𝑛, 𝑛) and 9 Be ⁢(𝑛, 𝑛) neutron scattering reference measurements

The 252 Cf spontaneous fission (sf), prompt fission neutron spectrum (PFNS) is a fundamental quantity for nuclear physics measurements of neutron-emitting reactions. This energy distribution of neutrons emitted from fission has been considered a neutron data standard for decades and has been utilized as a reference for neutron detection efficiency, validation of Monte Carlo simulations, benchmarking of dosimetry standards, and more. A significant portion of the global collection of nuclear data on neutron-induced reactions is correlated with the 252 Cf ⁢(sf) PFNS. Despite the reliance on this quantity by the nuclear physics community, the historical collection of 252 Cf PFNS measurements display systematic disagreements that are not understood or easily explained. These experimental discrepancies could potentially bias the 252 Cf PFNS Standard evaluation. On top of this, these past experiments frequently employed correlated experimental measurement or analysis methods. The artificial intelligence (AI)/machine learning (ML)-informed californium chi-nuclear data experiment (AIACHNE) project was formed to (a) investigate these discrepancies utilizing AI/ML methods to identify outlying regions of literature data, assign these regions to features of the experiment itself, and perform an improved evaluation of the 252 Cf PFNS and (b) perform a new experimental measurement of this quantity designed to improve upon the existing literature database. Here, in this work, we report on the AIACHNE 252 Cf PFNS experiment utilizing a new analysis method uncorrelated with all previous measurements: neutron efficiency determinations based on elastic neutron scattering on 12 C and 9 Be . This new method provides an independent test of the existing literature data and evaluation of the 252 Cf ⁢(sf) PFNS. The method is described with detailed covariance quantification procedures, as well as a direct discussion of the sources of uncertainty described as requirements in the “Templates” series of papers. The 252 Cf ⁢(sf) PFNS reported in this work agrees well with the overall shape of the existing standard PFNS evaluation as well as many literature measurements, thus verifying the current evaluation utilizing new techniques. However, the results suggest that there are deficiencies in the angle-differential 12 C and 9 Be ⁢(𝑛, 𝑛) evaluated nuclear data, which produce unphysical structures in the reported result. While these structures are relatively minor, they become obvious because of the high statistical precision of the data and the expected smooth continuity of the 252 Cf ⁢(sf) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Detectors for Scattering Applications

The book covers, for the first time, the most common neutron detectors used in neutron scattering facilities and all of those in use at Oak Ridge National Lab. The first two chapters describe the facilities, instruments and the critical detector parameters needed by various instruments. The third chapter focuses on the key components of the 3He-based linear position sensitive detectors as well as on their electronics, which require particular attention to signal-processing and noise reduction. The fourth chapter is dedicated to the 3He alternatives where scintillators play a critical role. Finally, chapter 5 covers emerging neutron detection technologies including semiconductors, vacuum-based devices and their associated readouts, which will be required in the future for high rate and high-resolution neutron detectors.

Diawara, Yacouba↗

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. A 33-MeV 2 H + beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Furthermore, these data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

42 ENGINEERING↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Real-time neutron multiplicity and source localization for criticality safety during fuel debris removal

Advancing neutron detection and analysis techniques for complex radiation environments is an ongoing focus in nuclear instrumentation and monitoring. This proposal presents research and development of a generalized real-time neutron monitoring and analysis system, applicable to any detector capable of producing time-tagged neutron count data. While the work is demonstrated using the Neutron Multiplication Analysis Detector (NoMAD), a modular 15-tube helium-3 (He-3) array, due to its availability, spatial resolution, and flexible deployment, the methods developed are extensible to other systems, including organic scintillators and fast digital detectors. This research investigates two complementary analytical techniques for real-time characterization of neutron emitting sources: neutron multiplicity estimation based on the Hage-Cifarelli formalism and spatial localization using supervised machine learning applied to spatial count rate patterns. These methods are designed to operate under dynamic, evolving conditions such as fuel debris retrieval or reactor startup, where neutron-emitting material geometries may be partially unknown or changing over time. By integrating statistical neutron emission data with spatial localization, this research aims to develop and evaluate methods for real time neutron monitoring, source characterization, and material verification. Key contributions include implementation of a low-latency data pipeline for continuous neutron multiplicity analysis, development and validation of machine learning models for spatial inference, and experimental evaluation of system performance under variable measurement conditions. The outcomes are intended to support applications in nuclear safeguards, verification, emergency response, and reactor startup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial evaluation of a multimodal diamond sensor for simultaneous temperature and radiation measurements

Several experimental disciplines require simultaneous neutron flux and temperature monitoring. This paper provides the groundwork on a diamond sensor concept that could be used in harsh environments where the limits of current technologies are exceeded. Here, we present initial results on the functionality of a multimodal diamond sensor, which can simultaneously sense the presence of alpha particles at a few counts per second at temperatures up to 494 K. Such a sensor may also have applications where both charged particles or neutron detection and temperature measurement are simultaneously desired.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Applications of quantum materials in nuclear physics experiments (Final Report)

The goals of this project are to search for hypothesized spin-hall effects of neutrons and variants of neutron-electron hybrid spin hall effects in quantum materials with strong spin-orbit-coupling (SOC) – such as: • Deflection of neutrons dependent on spin (polarization) states (a); • Electrical current induced electron spin polarization or (dynamically polarized) nuclear spin polarization (as suggested in PI’s prior work) may affect polarization states of transmitted or reflected neutron beam • Spin polarized neutrons transfer some spin angular momenta to electrons, which get converted to electronic charge voltage via electronic inverse spin Hall effect (b), which if realized, offers an electrical method to detect neutron spins.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two bright, optically clear, intrinsic fast-neutron and charged-particle detector materials for neutron imaging and other applications

Two optically clear, bright, scintillating ZnS materials have been identified that, like previous opaque ZnS scintillators, are excellent charged particle detectors. We show that ZnS is a good fast-neutron-to charged-particle converter making optically clear ZnS an intrinsic fast-neutron detector that does not require layering or mixing of converter materials and scintillator materials, and removes the limitations imposed by opaque ZnS scintillator materials used for more than a century. Thermal neutron detection using optically clear 6 LiF or 10 BN and clear ZnS may benefit from improved spatial resolution and light transmission. Properties and tests of clear scintillating ZnS are described. Fast-neutron imaging applications benefit from increased efficiency of these scintillators, minimal scattering in the scintillator, and increased useful detector volume. Charged particle and fast-neutron detectors have numerous applications in nuclear non-proliferation and security, nuclear and particle physics, and non-destructive testing and environmental measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNAPRed: Reduction of multidimensional neutron time-of-flight diffraction data

SNAP is a neutron time-of-flight diffractometer at the Spallation Neutron Source operated by Oak Ridge National Laboratory. It generates large arrays of neutron detection events that encode the crystalline atomic structure of materials under study. SNAPRed is an application that makes these datasets accessible to end users by orchestrating the process of data reduction while automatically managing the variable neutron instrumentation configuration. It supports arbitrary grouping and masking of individual detector pixels and includes custom-developed data compression approaches to accommodate the large volumes of data generated by the SNAP instrument.

Diffraction↗

Observation of Forward Neutron Multiplicity Dependence of Dimuon Acoplanarity in Ultraperipheral Pb-Pb Collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

The first measurement of the dependence of $γγ → μ^+μ^–$ production on the multiplicity of neutrons emitted very close to the beam direction in ultraperipheral heavy ion collisions is reported. Data for lead-lead interactions at $\sqrt{s_{NN}}$ = 5.02 TeV, with an integrated luminosity of approximately 1.5 nb –1 , are collected using the CMS detector at the LHC. The azimuthal correlations between the two muons in the invariant mass region 8 < $m_{μμ}$ < 60 GeV are extracted for events including 0, 1, or at least 2 neutrons detected in the forward pseudorapidity range |η| > 8.3. The back-to-back correlation structure from leading-order photon-photon scattering is found to be significantly broader for events with a larger number of emitted neutrons from each nucleus, corresponding to interactions with a smaller impact parameter. This observation provides a data-driven demonstration that the average transverse momentum of photons emitted from relativistic heavy ions has an impact parameter dependence. These results provide new constraints on models of photon-induced interactions in ultraperipheral collisions. They also provide a baseline to search for possible final-state effects on lepton pairs caused by traversing a quark-gluon plasma produced in hadronic heavy ion collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of neutron-proton capture in the $\mathrmSNO+ water phase

The SNO+ experiment collected data as a low-threshold water Cherenkov detector from September 2017 to July 2019. Measurements of the 2.2-MeV γ 's produced by neutron capture on hydrogen were made using an Am-Be calibration source, for which a large fraction of emitted neutrons are produced simultaneously with a 4.4-MeV γ. Analysis of the delayed coincidence between the 4.4-MeV γ and the 2.2-MeV capture γ revealed a neutron detection efficiency that is centered around 50% and varies at the level of 1% across the inner region of the detector, which to our knowledge is the highest efficiency achieved among pure water Cherenkov detectors. Finally, in addition, the neutron capture time constant was measured and converted to a thermal neutron-proton capture cross section of $336.3^{+1.2}_{-1.5}$ mb .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Fission-like Neutron Spectrum Shaping Assembly based on D-T Generator

For nearly five decades, 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. While there appear to be no other radionuclide neutron sources that would match the 252 Cf performance characteristics, all of them, including 252 Cf, present similar concerns in terms of hazards, safety, and security. As a possible solution to this issue, the Pacific Northwest National Laboratory (PNNL) developed a low-risk, cost-efficient alternative to produce fission-like spectra based on commercially available deuterium-tritium (D-T) neutron generators. The alternative of producing a fission-like neutron spectrum without any fissionable materials or beryllium would enable the nuclear facilities across the entire complex to eliminate their reliance on high intensity 252 Cf sources for nuclear safety and radiation protection applications, substantially reducing risks and associated costs. This report describes efforts of designing the spectrum shaping assembly, its construction and characterization of the neutron field produced. Performance of this newly developed D-T generator based neutron field is demonstrated via calibration of a criticality detector, neutron survey instruments, and personal dosimeters verified against current standardized fields produced by 252 Cf spontaneous fission sources.

42 ENGINEERING↗

LLE Diagnostic Resource Team for Innovative Fusion Concepts (Final Report)

The LLE Diagnostic Resource Team for Innovative Fusion Concepts provided travelling neutron diagnostics, consultancy on neutron diagnostics, and consultancy on tritium handling to fusion companies. An existing neutron detector was recalibrated for low yields and two detectors were built based on designs proven on the Omega Laser Facility. The three detectors allow measurements over a wide range of yields (from 10 to 1E7 incident neutrons). The detectors were calibrated for DD neutrons on a dedicated OMEGA shot day. Neutron detectors from the company MIFTI were also calibrated on OMEGA. MIFTI is currently using their detectors and two of our detectors on staged Z-pinch experiments at UCSD. The Team acted as consultants for the development of a liquid scintillator array to detect neutrons from muon induced fusion by NK Labs. Segments of NK Labs’ detector were tested at the LLE using radioactive sources and a DD neutron generator. The Team also acted as consultants for the design of a tritium handling system for NK Labs. A new type of neutron spectrometer was designed and built, and has completed preliminary testing.