Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “natural ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

98 records · Page 6

An Experimental Investigation of the Flow of Air in a Flat Broadening Channel

The wide use of diffusers, in various fields of technology, has resulted in several experimental projects to study the action and design of diffusers. Most of the projects dealt with steam (steam turbine nozzles). But diffusers have other applications - that is, ventilators, smoke ducts, air coolers, refrigeration, drying, and so forth. At present there is another application for diffusers in wind-tunnel design. Because of higher requirements and increased power of such installations more attention must be paid to the correctness of work and the decrease in losses due to every section of the tunnel. A diffuser, being one of the component parts of a tunnel , can in the event of faulty construction introduce considerable losses. Therefore, in the design of the new CAHI wind tunnel, it was suggested that an experimental study of diffusers be made, with a view to applying the results to wind tunnels. The experiments conducted by K. K. Baulin in the laboratories of CAHI upon models of diffusers of different cross sections, lengths, and angles of divergence, were a valuable source of experimental data. They were of no help, however, in reaching any conclusion regarding the optimum shape because of the complexity and diversity of the factors which all appeared simultaneously, thereby precluding the.study of the effects of any one factor separately. On the suggestion of the director of the CAHI,Prof. B. N. Ureff, it was decided to experiment on a two-dimensional diffuser model and determine the effect, of the angle of divergence. The author is acquainted with two experimental projects of like nature: the first was conducted with water, the other with air. The first of these works, although containing a wealth of experimental data, does not indicate the nature of flow or its relation to the angle of divergence. The second work is limited to four angles - that is, 12 deg, 24 deg, 45 deg, 90 deg. The study of this diffuser did not supply any information about the effect of smaller angles which, because of their advantages, are more commonly used, The author was able to acquaint himself with the second work only after the experiments were started. For these reasons, as well as because on the basis of those works no conclusion can be reached regarding the nature of flow distribution, of eddies, and so forth, experimental work was continued. The need for determining flow patterns follows from the fact that from them are determined methods of measurement - that is, the determination of velocities by means of the pitot tube, which, as is well known, gives correct indications only when placed with its axis parallel to the axis of flow. The data contained in this report were obtained from experiments conducted by the Aerodynamical Laboratories of the CAHI. The solutions to some. of the mathematical problems connected with the experiments are due to Prof. S. A, Chapligin.

Vedernikoff, A. N.↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refrigerants for a Sustainable Future

Worldwide use of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants for space conditioning and food storage results in significant equivalent greenhouse gas (GHG) emissions. This is further exacerbated in developed countries by the current transition from hydrochlorofluorocarbon (HCFC) refrigerants to HFC refrigerants. Under the Kigali amendment to the Montreal Protocol, the proposed phase-out of currently used HFC and HCFC refrigerants has initiated a re-evaluation of some pre-existing refrigerants as well as the development and evaluation of new refrigerants. Making the ideal refrigerant selections for heating, ventilation, air-conditioning, and refrigeration (HVAC&R) applications is thereby difficult in an already overabundant refrigerants market. In this paper, a study of key parameters required of a good refrigerant is conducted, followed by the analysis of refrigerants desired and refrigerants used in two major sectors of the HVAC&R industry, namely commercial refrigeration and residential air-conditioning and heat pumps. Finally, keeping in consideration the global environmental regulations and safety standards, a recommendation of the most suitable refrigerants in both sectors has been made.

54 ENVIRONMENTAL SCIENCES↗

Identifying dominant environmental predictors of freshwater wetland methane fluxes across diurnal to seasonal time scales

While wetlands are the largest natural source of methane (CH 4 ) to the atmosphere, they represent a large source of uncertainty in the global CH 4 budget due to the complex biogeochemical controls on CH 4 dynamics. Here we present, to our knowledge, the first multi-site synthesis of how predictors of CH 4 fluxes (FCH4) in freshwater wetlands vary across wetland types at diel, multiday (synoptic), and seasonal time scales. In this work we used several statistical approaches (correlation analysis, generalized additive modeling, mutual information, and random forests) in a wavelet-based multi-resolution framework to assess the importance of environmental predictors, nonlinearities and lags on FCH4 across 23 eddy covariance sites. Seasonally, soil and air temperature were dominant predictors of FCH4 at sites with smaller seasonal variation in water table depth (WTD). In contrast, WTD was the dominant predictor for wetlands with smaller variations in temperature (e.g., seasonal tropical/subtropical wetlands). Changes in seasonal FCH4 lagged fluctuations in WTD by ~17 ± 11 days, and lagged air and soil temperature by median values of 8 ± 16 and 5 ± 15 days, respectively. Temperature and WTD were also dominant predictors at the multiday scale. Atmospheric pressure (PA) was another important multiday scale predictor for peat-dominated sites, with drops in PA coinciding with synchronous releases of CH 4 . At the diel scale, synchronous relationships with latent heat flux and vapor pressure deficit suggest that physical processes controlling evaporation and boundary layer mixing exert similar controls on CH 4 volatilization, and suggest the influence of pressurized ventilation in aerenchymatous vegetation. In addition, 1- to 4-h lagged relationships with ecosystem photosynthesis indicate recent carbon substrates, such as root exudates, may also control FCH4. By addressing issues of scale, asynchrony, and nonlinearity, this work improves understanding of the predictors and timing of wetland FCH4 that can inform future studies and models, and help constrain wetland CH 4 emissions.

59 BASIC BIOLOGICAL SCIENCES↗

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

A Full-Scale Fire Program to Evaluate New Furnishings and Textile Materials Developed by the National Aeronautics and Space Administration

The plans for the present series of full-scale experimental fires were initiated at the suggestion of NASA following the presentation of a film and discussion illustrating Battelle-Columbus' recent work in fire research. That film showed bedroom-type fires carried out as a part of a program to determine the influence of the cyclic characteristics of real fires under limited ventilation on the burning and pyrolysis properties of the room furnishings. A new series of fires was suggested by NASA designed to show the performance of new fire resistant and fire retardant materials by providing comparative fire and smoldering environmental conditions. More recently, the goal for the new series of fires was written in a meeting with NASA personnel and others at Battelle on May 3 and 4, 1972. The goal was as follows: To establish the need for special materials of improved fire safety in domiciliary settings of public concern, and to assess, in a professionally acceptable manner, the potential of materials arising from the new space-age technology for this purpose. It was anticipated that some new materials arising from the space-age technology and not yet available through conventional commercial channels might provide significant improvements in fire safety if the best of the commercially available materials showed important shortcomings in this area. It was the intent of this program to assess the benefits that could accrue from the use of these new materials. Fire safety is a matter requiring the evaluation of a number of factors. For example, fire resistance and fire spread, visibility during the fire, toxicity of evolved gases, and the fire-fighting problem that is created must be evaluated before the relative hazard can be assessed. The plan of the program provided for sampling and instrumentation to evaluate these factors, consistent with the goal of technological utilization that has been specified. Arrangements were made with the Columbus Fire Department to use an existing six-story concrete building', designed and used as a fire training tower, as the site for the experimental fires. The visual evidence provided by TV and photographic coverage of the four experimental room fires showed clearly that the rooms responded very differently to a common ignition condition. In particular: (1) The Typical room, furnished from conventional retail sources, ignited easily and burned rapidly so that after 8 minutes the contents of the room were nearly destroyed. (2) The Improved room, furnished with materials selected as being among the best commercially available, showed substantial improvement over the Typical room in that there was slower fire spread. However, the relatively complete destruction of the room contents that resulted, and the large amounts of smoke, made it clear that substantial further improvements were needed. This fire was stopped after 29 minutes. (3) The Space-age room, furnished completely with new materials that were not yet commercially available, did not ignite under the common ignition condition and soon demonstrated the substantial improvement in fire resistance available for those components close to the ignition source. A second and larger ignition arrangement showed that this room can burn, but the difficulty with which this was brought about confirmed the improved fire resistance available with use of these materials. (4) The Mixed room ensemble, furnished with 'materials identical to the Typical room except for the substitution of the bed from the Space-age room, illustrated the improvement in control of fire spread available by careful placement of fire materials in the important paths of fire development of an otherwise ordinary room. The most significant hazards at early times in each fire were due to the rapid rise in heat flux and the abrupt obscuration of vision by smoke. The most consistent toxicity hazard was due to CO and its importance would depend on the ability of the occupant to survive the initial heat and smoke menace which characterized each fire room. Other gases and vapors were shown to reach hazardous levels in certain fire rooms and, again, their significance to an occupant, would relate to the times in which such hazards occurred, and probably to the synergistic nature of the hazard arising from mixtures of such gases. Fire retardant items in the room are caused to pyrolyze by the heat of burning from other items in the room and so contribute to combustible and toxic vapor accumulations, even though they may not have entered into the burning process. This effect of a mixture of combustible materials to produce burning and pyrolysis not characteristic of any one item individually we have chosen to call the "ensemble effect". Further full-scale fire trials may be expected to show the significant changes that control the burning and pyrolytic processes and in that event a programmed fire chamber should be developed to yield realistic laboratory results.

Hillenbrand, L. J.↗

An international study on THM modelling of the full-scale heater experiment at Mont Terri laboratory

We present results from an international model comparison study of the Full-Scale Emplacement (FE) experiment in Opalinus Clay at the Mont Terri Laboratory, Switzerland. Based on a provided parameter set the teams decided which parameters they adopted for their models, whether they considered the excavation and the ventilation phase in addition to the heating phase and if they included technical features like the shotcrete or the EDZ. The teams were able to reproduce the measured parameters temperature, relative humidity and pore pressure. The modelled results for temperature agree very closely between the teams especially in the sensors in Opalinus Clay. All teams were able to reproduce the redistribution of water in the bentonite backfill due to heating. The evolution of the relative humidity showed similar trends with differences in the intensity of the dry out effect. To model the pore pressure evolution is more complex because it comprises the full interaction of the coupled THM processes. The spread between the pore pressure modelled by the teams was larger, with some teams overestimating the pressure increase due to heating and some teams overestimating the extent of drainage. The agreement of modelled results with measurements improves with larger distance to the heater. We conclude that the EDZ and the shotcrete potentially influence the behaviour of the rock causing higher differences closer to the heater. Further research is needed to better implement those influences into the models. Based on the calibrated models, the future evolution of temperature, relative humidity and pore pressure was predicted over the next 10 years following a change of the heat power applied in 2023 and 2024. Again, the predicted temperatures agree very closely between the teams. Most teams do not expect an increase in relative humidity during the next 10 years after the initial dry-out.

58 GEOSCIENCES↗