Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “narrow linewidth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Narrow polarized components in the OH 1612-MHz maser emission from supergiant OH-IR sources

High-resolution (300 Hz) OH 1612-MHz spectra of the supergiant OH-IR sources VY CMa, VX Sgr, IRC 10420, and NML Cyg are presented. Linewidths as small as 550 Hz (0.1 km/s) are found for narrow components in the spectra. The present results are consistent with current models for maser line-narrowing and for the physical properties in the OH maser regions. A significant degree of circular polarization is noted in many of the narrow components. The circular polarization suggests the presence of magnetic fields of about 1 mG in the circumstellar envelopes which would be strong enough to influence the outflow from the stars, and which may explain asymmetries found in the circumstellar envelopes.

Cohen, R. J.↗

Dye laser tuning with pellicles.

Thin nitrocellulose membranes (pellicles) are shown to exhibit properties which make them suitable for intracavity tuning elements in high-energy pulsed dye lasers. Uncoated pellicles of 2-micron and 8-micron thickness with surface figures of lambda/1 are shown to closely approximate the properties of low-finesse etalons with wide free spectral ranges. Pellicles of 8-micron thickness, coated on both surfaces with 50% reflectivity multilayer dielectrics, are shown to be effective as spectral narrowing elements with peak transmission greater than 80% and resultant laser linewidths of 0.57 nm full width at half-maximum.

Mumola, P. B.↗

Parametric infrared tunable laser system

A parametric tunable infrared laser system was built to serve as transmitter for the remote detection and density measurement of pollutant, poisonous, or trace gases in the atmosphere. The system operates with a YAG:Nd laser oscillator amplifier chain which pumps a parametric tunable frequency converter. The completed system produced pulse energies of up to 30 mJ. The output is tunable from 1.5 to 3.6 micrometers at linewidths of 0.2-0.5 /cm (FWHM), although the limits of the tuning range and the narrower line crystals presently in the parametric converter by samples of the higher quality already demonstrated is expected to improve the system performance further.

Garbuny, M.↗

Optical feedback effects on the performance of Pb/1-x/Sn/x/Se semiconductor lasers

The effects of optical feedback on the performance of Pb(1-x)Sn(x)Se semiconductor lasers are reported. Experimental results are presented to demonstrate that uncontrolled optical feedback can occur from optics external to the laser cavity and that these external optical elements can result in the formation of a composite cavity. This composite cavity can sustain a number of narrow closely spaced emission modes with the spectral characteristics of these modes dependent upon the parameters of the cavity. With weak feedback, the spectral width of the amplitude envelope of the new lasing modes resembles that of the original laser mode with no optical feedback. With strongly coupled feedback the envelope of the external cavity modes substantially broadens the apparent linewidth of the laser. It is shown that these effects can be eliminated, and, moreover, they offer the potential for obtaining spectrally narrow single-mode emission from Pb-salt lasers through the use of carefully designed external cavities.

Harward, C. N.↗

Linear ion trap based atomic frequency standard

In order to develop a trapped ion-based fieldable frequency standard with stability 1 x 10 to the -13th/sq rt tau for averaging times tau greater than 10,000 s, a hybrid RF/DC linear ion trap was developed which permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the RF confining fields. The authors have confined Hg-199(+) ions in this trap and have measured very high Q transitions with good SNRs. In preliminary measurements they obtained stabilities of 1.6 x 10 to the -13th/sq rt tau (tau between 50 and 800 s) with a 160-mHz wide atomic resonance linewidth and a signal-to-noise ratio of 40 for each measurement cycle. Atomic resonance lines as narrow as 30 mHz on the 40.5-GHz clock transition have been measured with no appreciable reduction in the ion signal. A stability of 7 x 10 to the -14th/sq rt tau is made possible by the signal-to-noise and line Q of this measured transition. Analysis of fundamental sources of frequency instability indicates that a long-term stability of 2 x 10 to the -16th is feasible for this device with existing technology for tau = 10 to the 6th s or more.

Prestage, John D.↗

Coherent anti-Stokes Raman spectroscopic modeling for combustion diagnostics

The status of modelling the coherent anti-Stokes Raman spectroscopy (CARS) spectra of molecules important in combustion, such as N2, H2O, and CO2, is reviewed. It is shown that accurate modelling generally requires highly precise knowledge of line positions and reasonable estimates of Raman linewidths, and the sources of these data are discussed. CARS technique and theory is reviewed, and the status of modelling the phenomenon of collisional narrowing at pressures well above atmospheric for N2, H2O, and CO2 is described. It is shown that good agreement with experiment can be achieved using either the Gordon rotational diffusion model or phenomenological models for inelastic energy transfer rates.

Hall, R. J.↗

Characteristics of intermediate-degree solar p-mode line widths

Measurements of the p-mode linewidths over the frequency range v = 1.87-4.93 mHz and degree range 1 = 1-150 are presented. The linewidth is observed to vary with mode frequency and degree. The variation with frequency is consistent with the observations of Libbrecht although the measurements are systematically narrower. The frequency variation has been explained in terms of radiative and convective damping of the modes. The observed variation with degree resolves previous contradictory results and is shown to exceed the 1/S variation that is expected in theoretical grounds. Here S is the travel time of a mode from its lower turning point in the solar interior, to its reflection at the solar surface. The deviations from a 1/S variation suggest that there are two possible damping mechanisms, in addition to radiative and convective damping, that affect the modes.

Jefferies, S. M.↗

Broadening of fast-beam spectral lines due to diffraction at the entrance slit of a spectrometer.

Experimental and theoretical demonstration of the necessity to take into account the effects of diffraction at a spectrometer's entrance slit in adjusting the spectrometer for observation of fast-beam spectral lines under conditions of minimum linewidth. An approximate expression is obtained for the optimum entrance slit width to be used in order to avoid the pronounced broadening of the spectral lines that occurs for very narrow entrance slits.

Leavitt, J. A.↗

Development of a Sodium LIDAR for Spaceborne Missions

We are currently developing laser and electro-optic technologies to remotely measure Sodium (Na) by adapting existing lidar technology with space flight heritage. The developed instrumentation will serve as the core for the planning of a Heliophysics mission targeted to study the composition and dynamics of Earths mesosphere based on a spaceborne lidar that will measure the mesospheric Na layer. There is a pressing need in the Ionosphere Thermosphere - Mesosphere (ITM) community for high-resolution measurements that can characterize small-scale dynamics (i.e. Gravity Waves with wavelengths smaller than a few hundred km) and their effects in the Mesosphere-Lower-Termosphere (MLT) on a global basis. This is compelling because they are believed to be the dominant contributors to momentum transport and deposition in the MLT, which largely drive the global circulation and thermal structure and interactions with the tides and planetary waves in this region. We are developing a spaceborne remote sensing technique that will enable acquisition of global Na density, temperature and wind measurements in the MLT with the spatial and temporal resolution required to resolve issues associated with the structure, chemistry, dynamics, and energetics of this regionA nadir-pointing spaceborne Na Doppler resonance fluorescence LIDAR on board of the ISS will essentially make high-resolution, in time and space, Na density, temperature and vertical wind measurements, from 75-115 km (MLT region). Our instrument concept consisted of a high-energy laser transmitter at 589 nm and highly sensitive photon counting detector that allows for range-resolved atmospheric-sodium-temperature profiles. The atmospheric temperature is deduced from the linewidth of the resonant fluorescence from the atomic sodium vapor D2 line as measured by our tunable laser. We are currently developing a high power energy laser that allows for some day time sodium lidar observations with the help of a narrow bandpass filter based on etalon or atomic sodium Faraday filter with 5 to 10 pm optical bandwidth. The current baseline detector for the lidar instrument is a 16-channel Photomultiplier Tube with receiver electronics that has been space-qualified for the ICESat-2ATLAS mission. Our technique uses the 16-channels as a photon-number-resolving single detector to provide the required full-spectroscopic sodium lineshape waveform for recovering Mesospheric temperature profiles. In this paper, we will describe our instrument concept for a future Heliophysics space mission based on board of the International Space Station (ISS).

lidar↗

Observational determination of the masses of active galactic nuclei

The masses of 24 active galactic nuclei are determined on the basis of published observations, using data on both the X-ray variability and the width of the narrow forbidden lines of O III. The results are presented in tables and graphs, and it is found that the mass estimates based on the X-ray variability are in good agreement with the dynamic masses determined from the O III linewidth when reasonable values are selected for the radius of the region of X-ray origin and when a standard photoionization model is adopted for the line-emitting gas. The O III dynamic masses of Seyfert-2 nuclei are shown to be systematically lower than those predicted by the (delta t)/M(O III) correlation for Seyfert-1 nuclei.

Wandel, A.↗

Many-Body Effects and Lineshape of Intersubband Transitions in Semiconductor Quantum Wells

Intersubband Transition (ISBT) infrared (IR) absorption and PL in InAs/AlSb were studied for narrow Quantum Wells (QWs). A large redshift was observed (7-10 meV) as temperature increased. A comprehensive many-body theory was developed for ISBTs including contributions of c-c and c-phonon scatterings. Many-body effects were studied systematically for ISBTs. Redshift and linewidth dependence on temperature, as well as spectral features were well explained by theory.

Ning, Cun-Zheng↗

In situ detection of tropospheric OH and HO2 by laser-induced fluorescence in a detection chamber at low pressure

Just as in the method of Hard and O'Brien, ambient air is pulled through an approximately 1 mm diameter inlet into a detection chamber that is maintained at a pressure of 2.4 torr. The ambient air stream travels through the detection chamber with a velocity of greater than 100 m sec(exp -1) in a narrow stream, constrained by the addition of an inert gas flow (0.4 torr). The OH molecule is both excited and detected in the A(exp 2)Sigma (v' = 0) yields X(exp 2)II (v'' = 0) transition at 308 nm. Light from a copper vapor-pumped dye laser (rep. rate = 10kHz; pulse length = 20 ns; linewidth = .1 cm(exp -1), and average power = 15 mW), resonant with the Q(sub 1)(3) transition, is multipassed through a White cell and intercepts the air stream as 24 non-overlapping 2mm by 5mm beams. A fast microchannel plate detector is turned off during the laser pulse to prevent saturation of the detector due to Rayleigh and chamber scattering. It is turned on 30-100 nsec after the end of the laser pulse for 300 ns to collect resonance fluorescence from OH. HO2 is detected by chemical conversion to OH by reaction with reagent NO, followed by OH detection. Both the detection sensitivity and the inlet characteristics must be understood for any in situ instrument. For the calibration of the detection sensitivity, OH is produced quantitatively by the fast H + NO2 yields OH + NO reaction in a low pressure, flowing discharge tube connected to the detection chamber. The inlet transmission of OH inlet is calibrated separately.

Brune, William H.↗

Actively Pumped Optical Filters at 532 nm

The operation of two narrow-band optical filters at 532.33 nm is presented. Both of these filters operate on the 4P(sub 1/2) to 8S(sub 1/2) excited-state transition in potassium vapor. One of the filters is based on excited-state Faraday effect, and requires the application of an external axial magnetic field. The peak transmission of this filter is approximately 3.5% with a linewidth of less than 10 GHz. The second filter does not require a magnetic field for its operation, but readily attains peak transmissions of 25-30%. The 4P(sub 1/2) state is excited by a 769.9 nm light pulse which is linearly polarized for the first scheme and circularly polarized for the second.

Billmers, Richard I.↗

Method and Apparatus for Linewidth Reduction in Distributed Feedback or Distributed Bragg Reflector Semiconductor Lasers using Vertical Emission

The linewidth of a distributed feedback semiconductor laser or a distributed Bragg reflector laser having one or more second order gratings is reduced by using an external cavity to couple the vertical emission back into the laser. This method and device prevent disturbance of the main laser beam. provide unobstructed access to laser emission for the formation of the external cavity. and do not require a very narrow heat sink. Any distributed Bragg reflector semiconductor laser or distributed feedback semiconductor laser that can produce a vertical emission through the epitaxial material and through a window in the top metallization can be used. The external cavity can be formed with an optical fiber or with a lens and a mirror of grating.

Cook, Anthony L.↗

Apparatus For Linewidth Reduction in Distributed Feedback or Distributed Bragg Reflector Semiconductor Lasers Using Vertical Emission

The linewidth of a distributed feedback semiconductor laser or a distributed Bragg reflector laser having one or more second order gratings is reduced by using an external cavity to couple the vertical emission back into the laser. This method and device prevent disturbance of the main laser beam, provide unobstructed access to laser emission for the formation of the external cavity, and do not require a very narrow heat sink. Any distributed Bragg reflector semiconductor laser or distributed feedback semiconductor laser that can produce a vertical emission through the epitaxial material and through a window in the top metallization can be used. The external cavity can be formed with an optical fiber or with a lens and a mirror or grating.

Cook, Anthony L.↗

Magnetic phases in lunar fines - Metallic Fe or ferric oxides.

The ferromagnetic resonance observed for the Apollo 11 and 12 lunar fines is characterized by an asymmetric lineshape with a narrower appearance on the high field side. This asymmetry together with an anisotropy energy which varies from +640 to +500 G over the temperature range of 80 to 298 K indicate that the ferromagnetic resonance arises from metallic Fe having the body-centered cubic structure and not from hematite, magnetite or other Fe(3+) ions in magnetite-like phases. The g-value, the lineshape asymmetry, and the temperature dependence of the linewidth for the Apollo 14 and 15 fines as reported by other workers are found to be essentially similar to those observed for the Apollo 11 and 12 fines.

Tsay, F.-D.↗

Narrowband alexandrite laser injection seeded with frequency dithered diode laser

Narrowband radiation is produced from a pulsed alexandrite laser when injection seeded with the output of a low power, tunable, continuous wave single mode diode laser. Injection seeded power oscillators are easier to frequency stabilize than etalon narrowed lasers, are more efficient and less prone to optical damage. AlGaAs diode lasers are available with wavelengths from 760 to 770 nm in the oxygen A band that can be used for differential absorption lidar remote sensing of atmospheric pressure and temperature. Diodes with room temperature output at 740 nm may be cooled sufficiently to emit in the water vapor absorption band at 720-730 nm for humidity remote sensing. The diode laser linewidth of 200 MHz is sufficient to seed 2 or 3 longitudinal modes of the multi-transverse mode alexandrite laser, giving the pulsed laser a bandwidth of 0.007 to 0.014/cm.

Schwemmer, Geary↗

Efficient 1.6 Micron Laser Source for Methane DIAL

Methane is a potent greenhouse gas and on a per molecule basis has a warming influence 72 times that of carbon dioxide over a 20 year horizon. Therefore, it is important to look at near term radiative effects due to methane to develop mitigation strategies to counteract global warming trends via ground and airborne based measurements systems. These systems require the development of a time-resolved DIAL capability using a narrow-line laser source allowing observation of atmospheric methane on local, regional and global scales. In this work, a demonstrated and efficient nonlinear conversion scheme meeting the performance requirements of a deployable methane DIAL system is presented. By combining a single frequency 1064 nm pump source and a seeded KTP OPO more than 5 mJ of 1.6 μm pulse energy is generated with conversion efficiencies in excess of 20%. Even without active cavity control instrument limited linewidths (50 pm) were achieved with an estimated spectral purity of ~95%. Tunable operation over 400 pm (limited by the tuning range of the seed laser) was also demonstrated. This source demonstrated the critical needs for a methane DIAL system motivating additional development of the technology.

Shuman, Timothy↗